• Title/Summary/Keyword: 7mm or less

Search Result 364, Processing Time 0.027 seconds

A Study on Effects of Air-delivery Rate upon Drying Rough Rice with Unheated Air. (벼의 자연통풍건조에 있어서 통풍량이 건조에 미치는 영향에 관한 연구)

  • 이상우;정창주
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.16 no.1
    • /
    • pp.3293-3301
    • /
    • 1974
  • An experimental work was conducted by using a laboratory-made model dryer to investigate the effect of the rate of natural forced-air on the drying rate of rough rice which was deposited in the deep-bed. The dryer consisted of 8 cylinderical containers with grain holding screen at their bottoms, each of which having 30cm in diameter and 15cm in height. The containers were sacked vertically with keeping them air-tight by using paper tape during dryer operation. Two separate layers of containers were operated in the same time to have two replications. The moisture contents of grains within each bins after predetermined period of dryer operation were determined indirectly by measuring the weight of the individual containers. The air-rates were maintained at 6 levels, or 5, 8, 10, 15, 18 and 20 millimenters of static head of water. The roomair conditions during dryer operation were maintained in the range of 10-l5$^{\circ}C$ in temperature and 40-60% in relative humidity. The results of the study are summarized as follows: 1. Drying characteristics of the grains in the bottom layers were approximately the same regardless of airdelivery rates, giving the average drying rate as about 0.35 percent per hour after 40-hour drying period, during which moisture content (w. b.) reduced from 24 percent to about 10 percent. 2. After about 40-hour drying period, the mean drying rates increased from 0.163 percent per hour to 0.263 percent per hour as air-flow rates increased from 5mm to 87.16mm of static head of water. In the same time, the moisture differences of grains between lower and upper layers varied from 12.7 percent at the air rate of 5mm of water head to 7.5 percent at the air-flow rate of 20mn of water head. Thus, the greater the air-flow rate was, the more overall improvement in drying performance was. Additionally, from the result of ineffectiveness of drying grain positioned at 70cm depth or above by the air rate of 5mm of static head of water it may be suggested in practical application that the height of grain deposit would be maintained adequately within the limits of air-rates that may be actually delivered. 3. Drying after layer-turning operation was continued for about 30 hours to test the effectiveness of reducing moisture differences in the thick layers. As a result of this layer-turning operation, moisture distribution through layers approached to narrow ranges, giving the moisture range as about 7 percent at air-flow rate of 5mm head of water, about 3 percent at 10mm head about 2 percent at 15mm head, and less than 1 percent at 20mm head. In addition, from the desirable results that drying rate was rapid in the lower layers and dully in the upper layers, layer-turning operation may be very effective in natural air drying with deep-layer grain deposit, especially when the forced air was kept in low rate. 4. Even though the high rate of air delivery is very desirable for deep-layer natural-air drying of rough rice, it can be happened that the required air delivery rate could not be attained because of limitation of power source available on farms. To give a guide line for the practical application, the power required to perform the drying with the specified air rate was analyzed for different sizes of drying bin and is given in Table (5). If a farmer selects a motor of which size is 1 or {{{{1 { 1} over {2 } }}}} H.P. and air-delivery rate which ranges from 8~10mm of head, the diameter of grain bin may be suggested to choose about 2.4m, also power tiller or other moderate size of prime motor may be recommended when the diameter of grain bin is about 5.0m or more for about 120cm grain deposit.

  • PDF

Postoperative Radiation Therapy in the Management of Early Cervical Cancer (초기 자궁경부암의 수술 후 방사선치료의 효과)

  • Kim, Jae-Chul
    • Radiation Oncology Journal
    • /
    • v.24 no.3
    • /
    • pp.164-170
    • /
    • 2006
  • [ $\underline{Purpose}$ ]: This study identified the result of postoperative radiation therapy and the prognostic factors to affect survival rates in cancer patients. $\underline{Materials\;and\;Methods}$: One hundred and thirty three patients with cervical cancer who were treated with postoperative radiation therapy following surgery at our institution between June 1985 and November 2002 were retrospectively analyzed. One hundred and thirteen patients had stage IB disease, and 20 patients had stage IIA disease. Histological examination revealed 118 squamous cell carcinoma patients and 15 adenocarcinoma patients. Sixty seven patients were noted to have stromal invasion greater than 10 mm, and 45 patients were noted to have stromal Invasion 10 mm or less. Positive lymphovascular invasion was found in 24 patients, and positive pelvic lymph nodes were noted in 39 patients. Positive vaginal resection margin was documented in 8 patients. All of the patients were treated with external beam radiation therapy to encompass whole pelvis and primary surgical tumor bed. Intracavitary radiation therapy was added to 19 patients who had positive or close surgical margins. $\underline{Results}$: Actuarial overall and disease-free survival rates for entire group of the patients were 88% and 84% at 5 years, respectively. Five-year disease-free survival rates for patients with stromal invasion greater than 10 mm and 10 mm or less were 76% and 97%, respectively (p<0.05). Also there was a significantly lower survival in patients with positive pelvic lymph nodes compared with patients with negative pelvic lymph nodes (p<0.05). However, lymphovascular invasion, positive vaginal resection margins were not statistically significant prognostic factors. Addition of neoadjuvant chemotherapy or type of surgery did not affect disease-free survival. $\underline{Conclusion}$: Postoperative radiation therapy appears to achieve satisfactory local control with limited morbidity in cervical cancer patients with high pathologic risk factors. Distant metastasis was a dominant failure pattern to affect survival in cervical cancer patients after radical surgery and radiation and more effective systemic treatment should be investigated in these high-risk patients.

Practical Implementation of Patient-Specific Quality Assurance for Small and Multiple Brain Tumors in CyberKnife with Fixed Collimators

  • Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • Progress in Medical Physics
    • /
    • v.29 no.2
    • /
    • pp.53-58
    • /
    • 2018
  • This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.

MOLECULAR CORES OF THE HIGH-LATITUDE CLOUD MBM7

  • MINH Y. C.;KIM H. G.;KIM S. J.;BERGMAN P.;JOHANSSON L. E. B.
    • Journal of The Korean Astronomical Society
    • /
    • v.33 no.1
    • /
    • pp.37-45
    • /
    • 2000
  • We have investigated the properties of the high-latitude cloud MBM 7 using the 3 mm transitions of CO, CS, HCN, $HCO^+,\;C_3H_2,\;N_2H^+$, and SiO. The molecular component of MBM 7 shows a very clumpy structure with a size of $\le$0.5 pc, elongated along the northwest-southeast direction, perpendicularly to an extended HI component, which could be resulted from shock formation. We have derived physical properties for two molecular cores in the central region. Their sizes are 0.1-0.3 pc and masses 1-2 M$\bigodot$ having an average volume density $\~2{\times}10^3 cm^{-3}$ at the peak of molecular emission. We have tested the stability of the cores using the full version of the virial theorem and found that the cores are stabilized with ambient medium, and they are expected not to be dissipated easily without external perturbations. Therefore MBM 7 does not seem to be a site for new star formation. The molecular abundances in the densest core appear to be much less (by about one order of magnitude) than the 'general' dark cloud values. If the depletions of heavy elements are not significant in the HLCs compared with those in typical dark clouds, our results may suggest different chemical evolutionary stages or different chemical environments of the HLCs compared with dense dark clouds in the Galactic plane.

  • PDF

Guidelines for the Management of Hydronephrosis Detected in the Perinatal Period (주산기에 발견된 수신증의 자연 경과와 치료 방침)

  • Chae Soo-Ho;Lee Ji-Hyuk;Jin Dong-Kyu;Park Kwan-Hyun;Paik Kyung-Hoon
    • Childhood Kidney Diseases
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2006
  • Purpose : Neonatal hydronephrosis is diagnosed with an incidence of 4.5-7% of pregnancies. Recently, early detection of neonatal hydroneprosis with antenatal ultrasonography has be-come possible. But consensus about its management has not been reached, especially concerning surgical intervention. The purpose of this study is to analyze the natural course of neonatal hydronephrosis and to determine the guideline of surgical intervention and follow up study. Methods : Sixty nine hydronephrotic kidneys were confirmed from April 2001 to April 2005. All cases were rechecked by ultrasonography once at least and had a minimum follow-up of 6 months. We classified the patients into 4 groups according to the anterior posterior pelvic diameter(APPD) on perinatal ultrasonography. Ultrasonography to measure the APPD diameter and Society for Fetal Urology(SFU) grade, $^{99m}Tc-MAG3$ scan were done to a set protocol. Pyeloplasty was peformed according to the protocol. Results : Pyeloplasty was not needed in most cases where the APPD was below 10 mm and where the SFU grade were less than grade 3. Many cases with APPD 10 mm above or SFU grade III above had undergone pyeloplasty. We found a correlation between obstruction grade on MAG3 scan and whether surgery was performed or not. Conclusion : If APPD is above 10 mm, SFU grade is above grade 3 or urinary tract obstruction is suspected by MAG3 scan, pyeloplasty must be considered. In cases where APPD is below 10mm and SFU grade is less than grade 3, we can observe the natural course of neonatal hydronephrosis with consecutive follow-up. (J Korean Soc Pediatr Nephrol 2006;10:33-39)

  • PDF

Result of Surgical Treatment of Intra-Articular Fractures of the Calcaneus - Based on CT Classification and Open Reduction and Internal Fixation - (종골 관절내 골절의 수술적 치료 후 임상 결과 -전산화 단층 촬영에 따른 분류 및 관혈적 정복 및 내고정 치료-)

  • Kim, Eui-Soon;Seo, Hyun-Mo;Lee, Kyu-Min;Choi, Hun-Hwi;Moon, Myung-Sang;Lee, Man-Hee;Choi, Won-Tae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.2
    • /
    • pp.238-249
    • /
    • 2003
  • Purpose: To report the clinical result of the intraarticular calcaneus fracture after open reduction and internal fixation with plate by lateral approach. Materials and Methods: Thirty-six calcaneal fractures of 33 patients(29 men and 4 women) were treated by open reduction and internal fixation using an lateral approach from March, 1997 to May, 2002 and were followed more than one year. The autogenous iliac bone graft was done in 2 cases but the others didn't. Radiographically B?hler angle and Gissane angle on simple lateral radiograph were measured and in the 15 cases, the step-off(gap) of posterior facet joint on post-operative CT images were followed. The Salama method was used for evaluation of clinical results. Results: According to Sanders classification, 19 cases of the 36 cases were classified as type II. Type III fracture were found in 12 cases and type IV in 5 cases. The following results were obtained: twenty-two cases(61.1%) out of 36 cases were estimated as good or excellent. The good results or more were obtained in 15 cases(78.9%) in type II and 7 cases(58.3%) in type ill, but no case in type IV. B?hler angles were improved from preoperative average 1.6?to postoperative average 23.4?, Gissane angle was improved from preoperative 107.2?to postoperative 122.8?, respectively. Among 36 cases, Computed tomography was carried out in 15 cases. The postoperative step-off (gap) of posterior facet joint on computed tomography was filled with cancellous bone. Satifactory results was obtained in 7 cases with 2mm gap or less and in 6 cases of 2-5mm. There were no satifactory results in 2 cases with 5mm gap or more. Conclusion: Open reduction and internal fixation for intra-articular fracture of calcaneus was thought to be a good treatment modality. It is thought that the lateral approach is one of the good one for surgical treatment, and that accurate reduction of the posterior facet, acceptable recovery of B?hler angle are more important to obtain best results.

  • PDF

Accuracy Evaluation and Analysis of SLAM for the Advancement of Forest Investigation (산림조사 고도화를 위한 SLAM의 정확도 평가 및 분석)

  • Yun, Hee-Cheon;Lee, Jong-Sin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.734-739
    • /
    • 2018
  • The National Forestry Inventory of Korea has started the 7th (2016 ~ 2020) survey from the first (1972 ~ 1974) National Forest Situation Survey. The diameter at breast height was measured using a diameter tape, and the tree height was measured using a hypsometer in the National Forestry Inventory of Korea from the 1st to recently the 7th surveying. In the case of the diameter tape, however, irregularly shaped trees may cause a large error. In the case of a hypsometer, the height may be measured indirectly in 10 cm increments to the front edge of the tree, so that the accuracy may be lowered. This paper suggests the use of SLAM to improve the accuracy and advance forest investigations. For this purpose, a test bed for the measurement of DBH and tree height was set up, and the scan data was acquired directly using SLAM equipment. The accuracy of DBH and tree height measurements were analyzed. As a result, it was possible to calculate directly the DBH and tree height to 1mm unit, and it showed that the DBH accuracy of 2cm or less and the accuracy of the tree height accuracy of 1.3cm or less are sufficient for practical use. Based on the results, the scan data will be acquired for sample points and analyzed.

Experimental Studies on the Vascular Smooth Muscle of $Cd^{2+}$-poisoned Rabbits (카드뮴중독(中毒) 가토(家兎)의 동정맥(動靜脈)에 관하여)

  • Hong, Ki-Whan
    • The Korean Journal of Pharmacology
    • /
    • v.15 no.1_2 s.25
    • /
    • pp.29-37
    • /
    • 1979
  • The tension-length relationships and reactivity of vascular smooth muscle in longitudinal strips from portal vein ana in helical strips from thoracic aorta and pulmonary artery of normotensive control and cadmium-hypertensive rabbits were studied in vitro. 1. The mean arterial pressures of non-poisoned control rabbits was $87.0{\pm}4.7 mmHg$. However, Cd-poisoned group revealed the significant increase in pressure by $109.04{\pm}2.8 mmHg$ (p<0.005). 2. By tension-length studies, strips from portal vein of Cd-poisoned group stretched a greater percent increase in length in response to an applied resting force from 0.25 to 5 g than did those from non-poisoned group. On the contrary, strips from thoracic aorta of Cd-poisoned group showed less compliant than those from control, i.e. the former underwent a less percent increase in length than the latter. Passive tension-length relations of pulmonary artery was unaffected by Cd-hypertension. 3. The force of contraction(active tension) was significantly lowered in strips from aorta of Cd-hypertensive group throughout the range of $0.5{\sim}2g$ passive tension. However, there was no significant difference in the development of active tension of portal vein or pulmonary artery of both groups. 4. The $K^+$-contraction in the portal vein, aorta and pulmonary artery of Cd-poisoned group made no difference in the active force from those of control group. 5. The force of contraction in the strips from aorta of Cd-poisoned group was significanty decreased compared to that of control. The results suggested that the alterations in vascular reactivity to contracting substances and in distensibility to passive tension were induced in the Cd-hypertensive rabbits.

  • PDF

A study on the Factors Affected on the P- and S-wave Velocity Measurement of the Acrylic and Stainless Steel Core (아크릴 및 스테인리스강 시험편의 P-, S-파 속도 산출에 미친 영향 요인 고찰)

  • Lee, Sang-Kyu;Lee, Tae-Jong
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.305-315
    • /
    • 2011
  • A total of 864 measurements for P- and S- wave velocity of acrylic and stainless steel core samples have been performed with respect to their lengths and axial load applied. S-wave velocity measurement was much harder than P-wave velocity, so that it showed higher deviation in measured S-wave velocity with respect to repeated measurement, length of the cores, and the axial load applied. Velocity measurements for acrylic cores showed more stable and less than half of the variation between the measurements than the stainless steel cores. This seems to be come from better coupling between the transducers and acrylic cores than stainless cores, and from larger value of the first arrival time in a similar system noise environments. From the analysis of the 864 measurements, it is recommended that the length of the core be 60 ~ 90 mm, axial load between 20 kg (27.7 $N/cm^2$) and 30 kg (41.6 $N/cm^2$) for measurement of wave velocity of the acrylic and stainless steel cores. Especially for measuring S-wave velocity of stainless steel core, core length should be less than 50 mm, otherwise it will be affected by mode conversion or others. These results can be used in measurement and correction for system delay in wave velocity measurement for rock cores.

A Survey Low Temperature Damage of Tea Tree at South Korea in 2011 (2011년 남부지방 차나무 저온 피해 조사)

  • Hwang, Jung-Gyu;Kim, Yong-Duck
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.14 no.4
    • /
    • pp.246-253
    • /
    • 2012
  • Despite frequent freezing injury to tea trees due low temperature, drought, and strong wind during wintertime, no comprehensive measurements have been taken. We selected and examined 9 locations in Hwagae-myeon and 4 places in Agyang-myeon, Hadong-gun, Gyeonsanggnam-do where low temperature damage had occurred between December 2010 and February 2011. Our objective is to examine the effect of frost damage on the morphological symptom and harvest of a tea tree exposed to a constant low temperature environment during wintertime. The results of our analyses on meteorological environment, tea leaf chromaticity, water content and trypan blue are as follows: (1) the number of days with temperature of $-10^{\circ}C$ or less, which were subject to frost damage to a tea tree were 8 and 13.6% during the winterization period in 2011; (2) the accumulated time was 1,308 minutes, and the longest duration at $-10^{\circ}C$ was 588 minutes from 21:08 p.m. 15 January to 7:30 a.m. $16^{th}$ January. The rainfall was only 104 mm which was 306 mm less than the previous year; (3) the lightness L values in 2011 were higher than in 2012 due to dehydration and necrosis by blue discoloration and red discoloration at all areas in chromaticity measurement; (4) the water content in a tea leaf in 2011 was higher than in 2012 due to low rainfall and strong wind, and almost no cell death phenomenon was observed from normal tea leaves subject to no low temperature stress in a trypan blue analysis; and (5) partial coloration due to cell death, however, took place in the leaves damaged by blue discoloration subject to low temperature stress, and most coloration due to cell death took place in the leaves damaged by red discoloration.