• Title/Summary/Keyword: 7T-MRI

Search Result 361, Processing Time 0.023 seconds

A Novel PHKA1 Mutation in a Patient with Glycogen Storage Disease Type IXD (당원 축적병 9D (GSD9D) 환자의 신규 PHKA1 돌연변이)

  • Kim, Hye Jin;Nam, Soo Hyun;Kim, Sang Beom;Chung, Ki Wha;Choi, Byung-Ok
    • Journal of Life Science
    • /
    • v.30 no.8
    • /
    • pp.672-679
    • /
    • 2020
  • Distal myopathy is a clinically and genetically heterogeneous group of degenerative diseases of the distal muscle. Glycogen storage disease type IXD (GSD9D) is a metabolic distal myopathy characterized by muscle deficiency of phosphorylase kinase, a key regulatory enzyme in glycogen metabolism. Affected individuals may develop muscle weakness, degeneration, and cramps, as well as abnormal muscle pain and stiffness after exercise. It has been reported that mutations in the PHKA1 gene which encodes the alpha subunit of muscle phosphorylase kinase cause GSD9D. In this study, we examined a Korean GSD9D family with a c.3314T>C (p.I1105T) mutation in the PHKA1 gene. This mutation has not been previously reported in any mutation database nor was it found in 500 healthy controls. The mutation region is well conserved in various other species, and in silico analysis predicts that it is likely to be pathogenic. To date, only seven mutations in the PHKA1 gene have been documented, and this is the first report of Korean GSD9D patients. This study also describes and compares the clinical symptoms and pathological conditions of previously reported cases and these Korean patients. We believe that our findings will be useful for the molecular diagnosis of GSD9D.

Sequential Involvement of Distinct Portions of the Medial Prefrontal Cortex in Different Stages of Decision Making Using the Iowa Gambling Task (갬블링 과제를사용한 의사결정 과정에서 중앙 전전두엽의 영역별 활성화에 대한 연구)

  • Lee, Jae-Jun;Bae, Sung-Jin;Kim, Yang-Tae;Chang, Yong-Min
    • Investigative Magnetic Resonance Imaging
    • /
    • v.13 no.2
    • /
    • pp.127-136
    • /
    • 2009
  • Purpose : Functional magnetic resonance imaging (fMRI) was used to assess the temporal response of neural activation in healthy subjects while they performed the Iowa Gambling Test (IGT), which utilizes decisions involving ambiguity and risk. The IGT was divided into five blocks of 20 trials; analysis showed that activity in the medial prefrontal cortex (mPFC) moves gradually from the dorsal to the ventral mPFC over the course of the IGT. These findings suggest that cognitive division of the mPFC, including the dorsal portion of the anterior cingulated cortex (ACC), plays a major role in ambiguous decision making and that the aspect of the IGT corresponding to risky decision making is associated with significant activity within the corticolimbic network strongly implicated in emotion and reinforcement. Our results also suggest that decisions made under ambiguity and decisions made under risk situations can be further divided into sub-phases based on the neural network involved.

  • PDF

Comparative Analysis of Spontaneous Infectious Spondylitis : Pyogenic versus Tuberculous

  • Lee, Yangwon;Kim, Bum-Joon;Kim, Se-Hoon;Lee, Seung-Hwan;Kim, Won-Hyung;Jin, Sung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.1
    • /
    • pp.81-88
    • /
    • 2018
  • Objective : Spondylitis is often chemotherapy resistant and requires long-term treatment. Without adequate chemotherapy, the outcome can be fatal or result in severe neurologic damage. Therefore, differentiating the etiology of spondylitis is very important, particularly in spontaneous cases. As the prevalence of tuberculosis in Korea has decreased in recent years, updated clinical research about spondylitis is warranted. Methods : From April 2010 to March 2016, data from spondylitis patients were collected retrospectively. In total, 69 patients (51 with pyogenic spondylitis and 18 with tuberculous spondylitis) were included. Clinical data, laboratory findings including erythrocyte sedimentation rate (ESR) and C-reactive protein (CRP) level, measurements of Cobb angles at the initial and final follow-up, and radiologic features on magnetic resonance imaging (MRI) scans were evaluated. To test differences between the pyogenic and tuberculous groups, numerical data were compared using the student's t-test and Mann-Whitney U test, and categorical data were compared using the chi-square test and Fisher's exact test. Results : The patients' mean age was 60.0 years. Male sex was slightly predominant (56.5%). There was no difference in mean age and sex between the two groups. The pyogenic group had a relatively higher proportion of immunocompromised patients. The peak CRP value was higher in the pyogenic group than in the tuberculous group (14.08 mg/dL and 8.50 mg/dL, respectively, p=0.009), whereas the ESR was not significantly different between the groups (81.5 mm/h and 75.6 mm/h, respectively, p=0.442). Radiologically, the presence of disc space sparing and vertebral body collapse differed between the groups. In the tuberculous group, the disc was more commonly preserved on contrast-enhanced MRI (50% and 23.5%, respectively, p=0.044), and vertebral body collapse was more common (66.6% and 15.7%, respectively, p<0.001). The mean length of hospitalization was longer in the pyogenic group (56.5 days and 41.2 days, respectively, p=0.001). Four mortality cases were observed only in the pyogenic group. The most commonly isolated microorganism in the pyogenic group was Staphylococcus aureus(S. aureus) (methicillin susceptible S. aureus and methicillin resistant S. aureus [MRSA] in 8 and 4 cases, respectively). Conclusion : The clinical and radiological manifestations of spontaneous spondylitis differ based on the causative organism. Pyogenic spondylitis patients tend to have a higher CRP level and a more severe clinical course, whereas tuberculous spondylitis patients present with destruction of the vertebral body with disc sparing more frequently. The presence of MRSA is increasing in community-acquired spondylitis cases.

Development of 1.0 Tesla Compact MRI System (1.0 Tesla 자기 공명 진단 장치의 개발)

  • Lee, H.K.;Oh, C.H.;Ahn, C.B.;Chang, Y.H.;Shin, D.W.;Lee, K.N.;Jang, K.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.11
    • /
    • pp.129-134
    • /
    • 1996
  • 1차 년도 G-7 개발 과제로 수행된 자기 공명 진단 장치 (Magnetic Resonance Imaging System)의 개발 내용을 간략히 소개하였다. 성공적인 IT Compact 자기 공명 진단 장치의 완성을 위해 일차적으로 (1)RF (고주파), Gradient(경사 자계), Spectrometer 등의 Hard-ware 관련 MRI 핵심부분, (2) RF, Gradient, Spectrometer, Magnet 등의 각 Sub-system을 연결, 조합, 조정하여 하나의 체계적인 시스템으로 통합하고 운영하는 과정(System Integration), (3)사용자와 시스템을 연결하는 User Interface, Data Base Management, Real time 운영 SW 등과 (4)임상에 적용하여 구체적인 성능과 효용성을 확인하는 기술 등에 대하여 집중 연구하였다. 개발 방법은 (1)지난 16년간 국내에 축적 된 연구 개발 인력들을 최대한 활용하고 (2)연구 개발을 국제화 시켜 필요한 경우 부분별로 개발 인력을 해외에서 보완하고 (3)소수 정예 전문 인력 주의와 요소 기술 또는 중요 부품을 경쟁성 검토 후 필요 시 Out-sourcing 활용으로 최저의 비용으로 개발 기간을 최소화 하는 데 두었다. 개발된 1.0Tesla자기 공명 영상 장치는 미국 물리 학회에서 규격화한 Phantom및 임상 적용을 통하여 서울대 의대 연구 팀과 지속적으로 성능을 평가해 왔다. 개발된 시스템의 해상도는 $256{\times}256$ head 영상에서 1mm 이 하의 해상도를 가짐을 resolution phantom 을 통하여 확인할 수 있었고, $512{\times}512$ 영상에서 는 약 0.5 mm 의 물체를 분리 해냄으로써 외제 시스템들 보다 우수하게 평가 되었다. 차폐 경사코일의 Eddy current영향은2%이내로 촬영 시 영향은 거의 무시할 수 있었다. 또한, 개발된 영상 기법들, 즉 Multislice/Multi Echo, Oblique angle imaging, 64 Echo train을 갖는 고속 촬영 기술들이 자기 공명 장치에 장착되어 임상 적용에 문제가 없도록 하였다. 또한 20mT/m/Amp의 강력한 능동 차폐 경사 자계 코일(Active Shield Gradient Coil)을 기본 사양으로 하고, 수신단을 최대 6개로 확장토록 하여 2차년도의 초고속 촬영 기법(EPI) 및 Phased Array 코일 촬영이 가능토록 하였다. 1차 년도 개발 과제 수행 결과와 향후 개발 과제를 바탕으로 최종 목표인 국제 경쟁력이 있는 자기 공명 진단 장치 즉 기능과 영상의 질은 선진국 제품과 동일하거나 우수하되, 저가격을 구현한 상용화 제품이 완성되어, 첨단 의료기기로서 산업 구조 고도화에 기여하고 수입대체 뿐만 아니 라 수출을 통한 국익 창출과 국가의 기술을 통한 위상 제고에 기여되길 기대한다.

  • PDF

The Evaluation for the Usefulness and Clinical Results of Arthroscopic Double Row Repair with UU Stitch for Massive Sized Full Thickness Rotator Cuff Tear (광범위 회전근 개 파열에서 관절경 감시하의 봉합술 - UU stitch를 이용한 이열봉합의 임상 결과 및 유효성 -)

  • Ko, Sang-Hun;Jeon, Hyung-Min;Shin, Seoung-Myung
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.2
    • /
    • pp.250-259
    • /
    • 2010
  • Purpose: The purpose of this study was to evaluate the usefulness and clinical results of arthroscopic double row repair with UU stitches for massive, full-thickness, rotator cuff tears. Materials and Methods: Between January 2007 and July 2009, we consulted on 36 massive tears in which it was possible to repair the middle area of the greater tuberosity by arthroscopy. One group consisted of 11 cases that had a double row repair with UU stitches. A second group consisted of 20 cases that had a single row repair with simple stitches. We compared the 2 groups for pain, Activities of Daily Living, UCLA score, and KSS score. We did this pre operatively, and at 6 months, 1 year and final follow-ups. Statistical analysis included Student's t test and a paired t est. Mean age was 59 (48~70); mean follow-up was 28 (12~43) months Results: VAS scores decreased from 7.5 pre operatively to 1.5 post operatively at the last f/u in the $1^{st}$ group (p<0.05). In the $2^{nd}$ group, the score decreased from 7.6 in pre op to 1.8 post operatively at the last f/u (p<0.05). There was no significant difference between the two groups (p>0.05). Mean ADL increased from 11.5 to 25.1 at the last f/u in the $1^{st}$ group (p<0.05); in the $2^{nd}$ group the ADL score increased from 11.3 to 27.5 (p<0.05). There was no significant difference between the two groups (p>0.05). The UCLA score increased from 13.9 to 31.6 in the $1^{st}$ group (p<0.05), while in the $2^{nd}$ group the score increased from 13.8 to 30.1 (p<0.05); there was no significant difference between the two groups (p>0.05). Comparing MRIs at 3 and 6 months post op, there were retears in 3 of 9 cases in the first group, and in 8 of 15 cases in the second group; there was no significant difference between the two groups (p>0.05). Conclusion: Arthroscopic double row repair with UU stitches for massive, full-thickness rotator cuff tears showed no differences in clinical results. However, it was associated with a significant difference in the incidence of retears.

A study on image distortion improvement using silicon device in thyroid diffusion MRI images (갑상선의 확산강조영상 검사 시 실리콘 이용한 뒤틀림 감소에 관한 연구)

  • Choi, Kwan-Woo;Seo, Dae-Keon;Lee, Ho-Beom;Goh, Hee-Jin;Na, Sa-Ra;Han, Dong-Kyoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.7
    • /
    • pp.4380-4386
    • /
    • 2014
  • This study was conducted to minimize the imaging distortion by reducing the differences in susceptibility between the tissue and air surrounding it while performing a thyroid diffusion imaging procedure. The study group was composed of 23 healthy adults. Thyroids with many distortions near the air, larynx, and trachea were chosen to test and evaluate the diffusion imaging difference between before and after an application of silicon. As a result, there was reduced distortion with silicon application, and the differences decreased from 30% to 10%. According to One-way ANOVA and Duncan's post-hoc test, there were no significant differences between imaging with a silicon application and T2 imaging of the surface area, which was the standard image. In conclusion, this study presented a radical improvement in reducing the distortions in imaging by compensating for an uneven tissue surface near air without affecting the magnetic resonance contrast and complicating the imaging processes.

A Functional MR Imaging Study of Reading (읽기의 기능적 자기공명영상에 관한 연구)

  • 유재욱;나동규;변홍식;최대섭;문찬홍;이은정;정우인
    • Investigative Magnetic Resonance Imaging
    • /
    • v.3 no.1
    • /
    • pp.78-83
    • /
    • 1999
  • Purpose : To evaluate the language areas activated by fMRI during different reading tasks and to assess the difference of activated areas according to each reading task. Materials and Methods : Functional maps of the language area were obtained during three reading tasks(Korean consonant letter, pseudoword, and word) in nine right-handed volunteers(7 males 2 females). MR examinations were performed at 1.5T scanner with EPI BOLD technique(gradient echo shot EPI, TR/TE 3000/60, flip angle $90^{\circ}$, matrix $64{\times}64$, 5mm thickness, no slice gap). Each task consisted of three resting periods and two activation periods and each period lasted 30 seconds. We used SPM program for the postprocessing of images and signification level was set at p<0.01. Activated areas were topographically analyzed in each stimulus. Results : Significant activated signals were demonstrated in all volunteers. Activated signals were seen in the frontal, temporal, parietal and occipital lobes during reading tasks and they were lateralized to the left hemisphere except occipital lobe. Letter and pseudoword produced stronger activated signals than word, and the activated signals were more lateralized to the left hemisphere in pseudoword reading than in letter reading. Conclusion : Activated signals were induced in the language areas by reading task of letter or wordform. Greater activation of language areas was induced when letter or pseudowords were presented than familiar words.

  • PDF

Depiction of Acute Stroke Using 3-Tesla Clinical Amide Proton Transfer Imaging: Saturation Time Optimization Using an in vivo Rat Stroke Model, and a Preliminary Study in Human

  • Park, Ji Eun;Kim, Ho Sung;Jung, Seung Chai;Keupp, Jochen;Jeong, Ha-Kyu;Kim, Sang Joon
    • Investigative Magnetic Resonance Imaging
    • /
    • v.21 no.2
    • /
    • pp.65-70
    • /
    • 2017
  • Purpose: To optimize the saturation time and maximizing the pH-weighted difference between the normal and ischemic brain regions, on 3-tesla amide proton transfer (APT) imaging using an in vivo rat model. Materials and Methods: Three male Wistar rats underwent middle cerebral artery occlusion, and were examined in a 3-tesla magnetic resonance imaging (MRI) scanner. APT imaging acquisition was performed with 3-dimensional turbo spin-echo imaging, using a 32-channel head coil and 2-channel parallel radiofrequency transmission. An off-resonance radiofrequency pulse was applied with a Sinc-Gauss pulse at a $B_{1,rms}$ amplitude of $1.2{\mu}T$ using a 2-channel parallel transmission. Saturation times of 3, 4, or 5 s were tested. The APT effect was quantified using the magnetization-transfer-ratio asymmetry at 3.5 ppm with respect to the water resonance (APT-weighted signal), and compared with the normal and ischemic regions. The result was then applied to an acute stroke patient to evaluate feasibility. Results: Visual detection of ischemic regions was achieved with the 3-, 4-, and 5-s protocols. Among the different saturation times at $1.2{\mu}T$ power, 4 s showed the maximum difference between the ischemic and normal regions (-0.95%, P = 0.029). The APTw signal difference for 3 and 5 s was -0.9% and -0.7%, respectively. The 4-s saturation time protocol also successfully depicted the pH-weighted differences in an acute stroke patient. Conclusion: For 3-tesla turbo spin-echo APT imaging, the maximal pH-weighted difference achieved when using the $1.2{\mu}T$ power, was with the 4 s saturation time. This protocol will be helpful to depict pH-weighted difference in stroke patients in clinical settings.

Development of Birdcage RF coil for 3T Animal MR Imaging

  • 추명자;최보영;강세권;최치봉;이형구;서태석
    • Progress in Medical Physics
    • /
    • v.13 no.2
    • /
    • pp.85-89
    • /
    • 2002
  • We authors developed a new small-size birdcage RF coil for animal MR images. And we compared signal-to-noise ratio (SNR) of the new small coil with a conventional knee coil. The dimension of the low-pass type birdcage coil with 12 elements at 37 MRI system are 13 cm outer diameter, 12 cm inner diameter and 20 cm length. For each element, the width of copper tape is 0.05 mm, thickness is 8 mm and length is 20 cm. The small birdcage coil with 12 elements exhibited 7 resonance modes. The isolation of the quadrature channel could be achieved more than 20 ㏈. The coil quality factor (Q value) was 98.6. The SNR of the animal coil was 243.2 on the average and was about twice as high as the conventional knee coil. The present study successfully demonstrated that the small birdcage coil could provide high quality animal MR images with the improved SNR. Therefore, it is expected that the small birdcage coil could be used in the clinical diagnosis and research studies for veterinary medicine in the near future.

  • PDF

Carotid Intraplaque Hemorrhage Imaging: Diagnostic Value of High Signal Intensity Time-of-Flight MR Angiography Compared with Magnetization-Prepared Rapid Acquisition with Gradient-Echo Sequencing

  • Ahn, Ji-eun;Kwak, Hyo Sung;Chung, Gyung Ho;Hwang, Seung Bae
    • Investigative Magnetic Resonance Imaging
    • /
    • v.22 no.2
    • /
    • pp.94-101
    • /
    • 2018
  • Purpose: To determine the value of the appearance of the high signal intensity halo sign for detecting carotid intraplaque hemorrhage (IPH) on maximum intensity projection (MIP) of time-of-flight (TOF) MR angiography (MRA), based on high signal intensity on magnetization-prepared rapid acquisition with gradient-echo (MPRAGE) sequencing. Materials and Methods: A total of 78 carotid arteries in 65 patients with magnetization-prepared rapid acquisition gradient-echo (MPRAGE) positive on carotid plaque MR imaging were included in this study. High-resolution MR imaging was performed on a 3.0-T scanner prior to carotid endarterectomy or carotid artery stenting. Fast spin-echo T1- and T2-weighted axial imaging, TOF, and MPRAGE sequences were obtained. Carotid plaques with high signal intensity on MPRAGE > 200% that of adjacent muscle on at least two consecutive slices were defined as showing IPH. Halo sign of high signal intensity around the carotid artery was found on MIP from TOF MRA. Continuous and categorical variables were compared among groups using the Mann-Whitney test and Fisher's exact tests. Results: Of these 78 carotid arteries, 53 appeared as a halo sign on the TOF MRA. The total IPH volume of patients with a positive halo sign was significantly higher than that of patients without a halo sign ($75.0{\pm}86.8$ vs. $16.3{\pm}18.2$, P = 0.001). The maximum IPH axial wall area in patients with a positive halo sign was significantly higher than that of patients without a halo sign ($11.3{\pm}9.9$ vs. $3.7{\pm}3.6$, P = 0.000). Conclusion: High signal intensity halo of IPH on MIP of TOF MRA is associated with total volume and maximal axial wall area of IPH.