• Title/Summary/Keyword: 765kV 송전선

검색결과 77건 처리시간 0.022초

765kV 2회선 송전선의 코로나 방전에 의한 환경영향 연구 (Environmental effects by corona discharge from a 765kV double circuit transmission line)

  • 김정부;이동일;신구용;양광호;안희성;구자윤
    • 대한전기학회논문지
    • /
    • 제45권3호
    • /
    • pp.451-455
    • /
    • 1996
  • This paper specified the measurement results conducted by the Korea Electric Power Research Institute (KEPRI) 765kV double circuit transmission test line that measured the audible noise, hum noise, radio interference, electric field and aeolian measurement. This test line consists of 6-480mm$^{2}$ conductors per phase. The analysis of the test results shows that this 6-Rail conductor bundle satisfies the audible noise criterion under the stable rainy weather condition and the radio interference level under the fair weather. And the other items are also agreed with the design level criterion. (author). 9 refs., 7 figs., 2 tabs.

  • PDF

가공송전선로에 의한 자계환경영향 검토 (An Investigation on the Environmental Effect of the Magnetic Field due to Overhead Transmission Line)

  • 정승용;임윤석;구자윤;이동일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.144-146
    • /
    • 2004
  • 송전선로 주변의 전자계 노출은 소아들의 암 발생/사망과 성인의 암 등 여러 가지 질병 발생 가능성이 항상 있으므로 전자계 노출을 장기간 계속적으로 받고 있는 환경을 관찰하는 것이 가장 중요하다. 따라서 본 연구에서는 이에 대한 연구기반을 형성하기 위해 송전 선로의 모델과 현장 실측을 통해 송전선로 자계치를 계산하여 시뮬레이션 하고자한다. 시뮬레이션을 통해 산출된 자계치를 이용하여 최근 효과적인 자계 저감책으로 보고되고 있는 수동루프에 의한 자계저감효과를 검토하고자 한다. 입력된 데이터는 765kV 실 송전선로를 모델로 사용하였으며, 자계의 계산 및 수동 루프에 의한 자계 저감 효과를 알아보기 위해서 미국 EPRI에서 개발한 자계 계산 전용 프로그램인 EMF Modeler를 이용하였다. 먼저 송전선로에 의해 발생되는 자계의 원리를 서술하였으며, 수동 루프를 통한 자계 감소 정도를 수식으로 유도하였고, EMF Modeler를 통하여 송전선 주변의 자계 분포 및 수통루프에 의한 자계 저감 효과를 각각 확인하였다.

  • PDF

한전 765 kV 송전선로 건설을 위한 강원도 태백.사북지역 착빙설 하중조건 검토 (A study on the ice and snow loading condition in Taebaek and Sabuk area in Gangwon province for the construction of KEPCO 765kV transmission lines)

  • 박광희;김용완;원봉주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1923-1924
    • /
    • 1996
  • Some part of the route in KEPCO 765kV transmission line being constructed passes through a high mountain area which is 800m above the sea level (Taebaek, Sabuk area in Gangwon province). This area is the top part of Taebaek mountains corresponding to the backbone of korean peninsula and has lots of snow during the winter season because the winter seasonal wind gone up along the mountainside of Taebaek Mts. meets open air of the East sea. KEPCO has experienced 63 faults of T/L between 1968 and 1993 in this area, which is a very serious problem. Especially 154kV Hwang-Ji T/L fault in 1990, 2 was a unprecedented case which needs to be analyzed carefully to take proper measures. After reviewing ice and snow loading conditions and analyzing the fault of Hwang-Ji T/L, we're going to determine the revisement of ice and snow loading condition in this area to increase reliability of 765kV transmission line.

  • PDF

통계적방법을 이용한 초고압 송전선의 전자계 특성 및 인체 안전에 관한 연구 (A Study on Characteristics and Safety for Human Body in ELF Electric and Magnetic Fields using Statistical Method)

  • 김두현;김상철
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.75-80
    • /
    • 1996
  • This paper presents a study on characteristics and safety for human body in ELF electric and magnetic fields using statistical method. The magnetic fields from a power line can be computed given a knowledge of the currents, voltage and geometry of the line. In this paper, a statistical method for predicting the magnetic fields given the inherent indetermination of the currents is presented. But the electric field is calculated given a knowledge of the voltage and geometry of the line. The effect of unexpected fluctuations in current is modeled by the Monte Carlo simulation. The suggested method is applied to the 345kV and 765kV transmission line system, the result shows that the maximum electric and magnetic field intensity is 6.8627kV/m and 284mG in 345kV system, 2. 5590kV/m and 35mG in 765kV system, respectively.

  • PDF

한전 765kV 송전선로 확충계획의 확률론적 신뢰도 평가 (Probabilistic Reliability Evaluation for 765kV Transmission Lines of KEPCO Grid Expansion Planning)

  • 트란트룽틴;권중지;최재석;전동훈;한경남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.237-239
    • /
    • 2005
  • The importance and necessity conducting studies on grid reliability evaluation have been increasingly important in recent years due to the number of black-out events occurring through in the world. Quantity evaluation of transmission system reliability is very important in a competitive electricity environment. The reason is that the successful operation of electric power under a deregulated electricity market depends on transmission system reliability management. Also in Korea it takes places. This paper presents the probabilistic reliability evaluation for 765KV transmission lines of KEPCO grid expansion planning. The Transmission Reliability Evaluation for large-Scale Systems (TRElSS) Version 6.2, a software package developed by Electric Power Research Institute (EPRI) is utilized in determining the improved probabilistic reliability indices of (KEPCO) system.

  • PDF

해외사업용 송전선로 설계시스템 개발 (Development of the Transmission Line Design System for Overseas Projects)

  • 민병욱;김종화;최석준;방항권;최한열
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.129-131
    • /
    • 2006
  • KEPCO constructed the first 765kV 2 circuit transmission line in the world with its home grown technologies. Through this 765kV transmission system project, KEPCO accumulated experience and technologies related to the 765 kV power system. Based on the successful completion of the 765kV transmission project, KEPCO is conducting overseas business by using its abundant experience and know-how. In particular, KEPCO developed the training course for power system, called the ATT (Advanced Transmission Technology) training courses for overseas business, especially for developing countries. Therefore, KEPCO developed the "Transmission line design system for overseas projects". This system supports the calculation of wind pressure load, tower design, wire selection, insulation design, etc. by applying the meteorological data of foreign countries and design standards. And this system is applied to the training program so that the trainees can design the optimal transmission line for their own countries.

  • PDF

765kV급 송전선로 공기절연거리 설정을 위한 시험전극의 섬락전압 특성 (The Flashover Characteristics of Test Electrodes against Clearance of Air Insulation for 765kV Transmission Line)

  • 김윤택;김영배;이형호;김정문;김정부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1337-1340
    • /
    • 1995
  • For the purpose of rational design of air insulation, it is need to experiment with similar to real shape test object and conform the characterisics. But basic distances of air insulation of transmission line, tower, etc. can be acquired from flashover characteristic of rod-rod, rod-plane electrodes. In this paper, before field test of 765kV transmission line for determination of distances of phase to ground insulation, we execute lightning, switching impulse test with test electrod(rod-rod, rod-plane) against clearances of air insulation. Each tests use up-down method and consist of 30 times flashover test. Flashover data treatment program and air correction program following IEC 60-1(1987) standard were completely builted.

  • PDF

전력수송의 고속도로 765kV 송전기술④(마지막회)

  • 이동일
    • 전기기술인
    • /
    • 제252권8호
    • /
    • pp.27-29
    • /
    • 2003
  • 최근 송전선로 및 변전소 인근 주민들이 전자계 때문에 각종 질병에 시달리고 있다고 주장하고 있고 환경단체에서도 전력설비에서 발생하는 전자계가 임신장해나 백혈병, 뇌종양 등 癌유발에 영향을 미친다는 주장에 따라 사회적으로 이에 대한 염려가 미친다는 주장에 따라 사회적으로 이에 대한 염려가 커지고 있는 상황에서 송전, 환경팀에서는 전기의 생산, 공급, 사용할 때 발생되는 주파수 60Hz에서의 전자계 영향을 객관적으로 파악하기 위하여 한국전기연구원 및 화학연구소와 공동으로 송전선로의 전자계 영향연구를 수행하였다.

  • PDF

고압 송전선로에서 극저주파 자기장 영향평가 적용에 관한 연구 (Evaluation of Extremely Low Frequency Magnetic Fields emission Level from High Voltage Transmission Lines)

  • 정준식;최성호;전형진;김윤신;홍승철
    • 환경영향평가
    • /
    • 제23권5호
    • /
    • pp.353-363
    • /
    • 2014
  • 본 연구의 목적은 가공송전선 인접 258개 시설과 120개의 고압 가공송전선, 17개의 지중화 송전선에서 자기장 방출량을 조사하였다. 또한 시뮬레이션을 이용하여 이격거리에 따른 ELF-MF 저감률을 파악하였다. 120개 고압 가공송전선의 전압 형태에 따라 자기장 방출량 조사한 결과, 154kV 고압송전선은 최소 60m, 345kV는 최소 80m, 765kV는 최소 100m 이격거리를 설정해야 고압송전선에서 발생하는 자기장 노출의 위해요인을 사전에 예방할 수 있을 것으로 나타났다. 극저주파 자기장의 방출량 시뮬레이션을 실시한 결과, 154kV의 경우 최대 부하가 걸린 시점에서 40m 이상, 345kV의 경우 60m 이격된 거리에서 4mG 이하로 나타났다. 환경영향평가학적 측면을 감안한 최악의 조건과 앞으로 증가될 전력 부하량을 감안하여 본 연구에서는 고압송전선로 최소 적정 이격거리는 70m 이상이 타당할 것이라 판단된다. 70m 내에 녹지대나 완충구역을 설정하여 수용체가 노출되지 않는 환경을 조성해야 차후 발생할 수 있는 극저주파 자기장 인체 위해성 관련 불안 요인을 제거할 수 있을 것으로 사료된다.

AC/DC 병가선로의 개폐서지 과전압 해석 (Analysis of Switching Surge Over-voltage in AC/DC Hybrid Transmission Lines)

  • 유성수;신구용;문채주
    • 한국전자통신학회논문지
    • /
    • 제17권3호
    • /
    • pp.459-466
    • /
    • 2022
  • 개폐서지는 전력시스템에서 발생하는 과전압 현상 중의 하나이며 변전소의 차단기 등 개폐장치의 동작이나 송전선로의 고장으로 인해 발생한다. 특히 송전선로의 절연설계를 위하여 개폐서지의 피크를 산정하는 것은 매우 중요하고 AC/DC 병가선로의 안정적인 운영을 위한 절연협조의 기본적인 검토항목이다. 본 논문에서는 새로운 AC/DC 병가구조의 전력시스템에 대한 상정해석을 위하여 AC 765kV와 DC ±500kV Bi-Pole 시스템이 조합된 송전선로를 대상으로 하였다. 일반적으로 교류 송전시스템의 절연설계를 위한 비정상적인 과전압은 외부과전압으로 낙뢰에 의한 과전압과 내부과전압으로 개폐에 의한 과전압을 고려한다. 직류 송전시스템의 경우에는 개폐에 의한 과전압 보다 송전선로의 중간에서 지락고장이 발생하면 인접한 정상선로에 유기되는 내부과전압을 개폐서지라하며 직류송전선로에 유기되는 가장 큰 일시적인 과전압을 의미한다. 본 논문의 연구목적으로 구성된 선로에 대하여 EMTDC 소프트웨어를 사용하여 모의하였으며, 다양한 AC/DC 혼합 형태에 대한 개폐과전압의 영향을 검토하였다.