• Title/Summary/Keyword: 72 Seconds

Search Result 77, Processing Time 0.027 seconds

Evaluation of the Odor with Aging (연령증가에 따른 향의 평가)

  • 강인형;민병찬;전광진;김철중
    • Science of Emotion and Sensibility
    • /
    • v.5 no.2
    • /
    • pp.1-9
    • /
    • 2002
  • It is already known that olfactory susceptibility differ with races and sex. Moreover, with aging both detection and identification about olfactory information were impaired. For researches about evaluation of the odor with aging, although the subject used, from infants to elderly, was various, the kinds of odor used were restricted to simple alcohol and acetic acid. Also, the evaluation methods were mainly used olfactory test. From over respects , this research was done as follows. Subjects were 19 to 72 years (n=50) whose sense-of-smell functions are normal. They were taken as stability and closed eye state. The odor stimuli were used 100% natural odor of six kinds of Basil, Lavender, Lemon, Jasmine, Ylangylang oil and Skatole , during 60 seconds using olfactometer. ECG, GSR and subjective evaluation were measured, and examined their relevance. Twenty and 40 ages group evaluated Lemon and 60 ages group did Lavender affirmatively. Correlation was seen among RRI, HR, GSR and subjective evaluation for 40 ages group, and it turns out that it is the group which a mature olfactory function most. These results are fully applied not only to development of the classified cosmetics for the age group but to development of the artificial smell and taste.

  • PDF

Studies on HOSS test and CTC test for Viability and Capacitation of Frozen-thawed Canine Sperm (개 정맥의 동결 및 융해후 정자의 생존성 및 수정능획득 판정을 위한 HOS test 및 CTC test)

  • 김용준;지동범;오홍근
    • Journal of Veterinary Clinics
    • /
    • v.17 no.2
    • /
    • pp.431-437
    • /
    • 2000
  • Evaluation of viability and capacitation of canine sperm is of great importance to deter- mine good condition for freezing canine semen and consequently to improve conception rate by arti-ficial insemination. Semen were collected from nine male dots which had been proved to be fertile in the post and the semen were treaded for freezing procedure. Semen were thawed at 37$^{\circ}C$ for 30 seconds. In this study, hypoosmotic swelling(HOS) test and chlortetracycline(CTC) test were per- formed to evaluate post-thaw viability and capacitated status of sperm, respectively. In HOS test far canine sperm, the highest percentage of curled sperm was shown at 60 mOsm. In HOS test for canine semen, there were considerably significant correlation between HOS values and sperm motil- ity(r=0.9064, p<0.01) and converse correlation between HOS values and sperm abnormality(r=- 0.6905, p<0.05). The sperm viability and HOS-values for chilled extended semen were significantly decreased from 0 to 72 hours during storage at 5$^{\circ}C$ (p<0.05). Of the media added to canine semen after thawing, the most capacitated sperm were shown in CCM(p<0.01), and then This Fructose Cit- rate(TFC) medium with calcium from 3 hours after incubation with media. It was concluded that HOS test is of great value to determine the viability and motility of canine sperm, whereas CTC test is usable to determine the capacitated status. Consequently, both tests were thought to be useful as the additional tests to standard semen analysis.

  • PDF

The Effect of Soleus Muscle Stretching on Thickness and Muscle Tone of The Tibialis Anterior and Peroneus Longus Muscles in Healthy Young Adults (건강한 젊은 성인의 가자미근 신장이 앞정강근과 긴종아리근의 근두께와 근 긴장도에 미치는 영향)

  • Jeon, Hyo-Bin;Oh, Seong-Won;Kim, Sun-Yeul;Hwang, Su-Jin
    • PNF and Movement
    • /
    • v.19 no.3
    • /
    • pp.341-349
    • /
    • 2021
  • Purpose: The purpose of this study was to investigate the effect of soleus muscle stretching on the muscle thickness and muscle tone of the tibialis anterior and peroneus longus muscles in healthy young adults. Methods: This study was an observational, cross-sectional study design in healthy young adults. Thirty healthy young adults participated in the study. To investigate the effect of agonist elongation on the muscles' antagonist and synergist characteristics, this study conducted the dynamic stretching of the soleus and plantarflexor muscles for 20 seconds. This study measured the muscle thickness and muscle tone of the soleus, tibialis anterior and peroneus longus muscles before stretching, immediately after stretching, and five minutes after stretching. Results: After analysis, the muscle tone of the soleus muscle was significantly decreased immediately after stretching (20.91±2.61Hz) compared to before stretching (21.83±2.78Hz). The muscle tone of the tibialis anterior was significantly decreased both immediately after stretching (21.76±2.73Hz) and five minutes after stretching (21.72±3.25Hz) compared to before stretching (22.61±3.29Hz). The muscle thickness of the soleus muscle was significantly decreased immediately after stretching (2.04±0.52mm) compared to before stretching (2.21±0.51mm) and was significantly increased five minutes after stretching (2.14±0.49mm) compared to immediately after stretching. Conclusion: The results of this study showed the static stretching of the soleus muscle changed the muscle tone of the tibialis anterior, but not of the peroneus longus muscle. This study suggests that the dynamic stretching of the agonist muscle would show meaningful muscle tone change in the antagonist.

Comparison of Power and Agility Evaluation by the Visual Response Speed Test after the Body Stabilization Exercise Intervention of Handball, ootball and Volleyball Athletes in Elementary School (초등학교 핸드볼, 축구, 배구 운동선수들의 신체안정화운동 중재 후 시각반응속도검사에 의한 힘과 민첩성 평가 비교)

  • Kim, Chul-Seung;Lee, Yong-Seon;Yun, Jong-Hyuk
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.9 no.4
    • /
    • pp.71-83
    • /
    • 2021
  • Purpose : This study compared the differences in power and agility of athletes in each sports using visual response speed test (VRST) scores after conducting 10 weeks of body stability exercise (BSE) on elementary school athletes in handball, football, volleyball and conducted a post-hoc test on the measured values. The subjects of this study were baseball (n=27), taekwondo (n=22), and football (n=23) athletes with at least two years of athletic experience. A total of 72 elementary school athletes were measured by VRST after 10 weeks of BSE under the same conditions. Methods : For VRST measurement of the upper extremity, the right and left hands were alternately touched in the order the blazepod equipment lights were turned on. The number of touches for 15 seconds and response touch were measured. In the case of the measurement of lower extremity the left lower extremity was measured first when the Blaze pod equipment light came on. The average value was obtained by measuring 3 times using a measurement sensor with the position indicated in order to measure the upper arms and legs the same. Results : This study confirmed homogeneity among sports and that VRST improved after implementing BSE for sports. However, no statistically significant difference was identified when comparing VRST improvements between sports, and post-hoc test results showed no significant differences either. Conclusion : After applying the BSE program under the same conditions for 10 weeks to elementary school students who can improve their power and agility the most, the results of the examination using the Blaze pod showed that the power and agility of baseball, taekwondo, and soccer players were similarly improved. From the fact that there was no significant difference among sports, it could be inferred that the BES training program could improve VRST without being limited to some sports.

MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING (접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도)

  • Cho, Young-Gon;Ko, Kee-Jong;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

Fixed-Point Modeling and Performance Analysis of a SIFT Keypoints Localization Algorithm for SoC Hardware Design (SoC 하드웨어 설계를 위한 SIFT 특징점 위치 결정 알고리즘의 고정 소수점 모델링 및 성능 분석)

  • Park, Chan-Ill;Lee, Su-Hyun;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.6
    • /
    • pp.49-59
    • /
    • 2008
  • SIFT(Scale Invariant Feature Transform) is an algorithm to extract vectors at pixels around keypoints, in which the pixel colors are very different from neighbors, such as vortices and edges of an object. The SIFT algorithm is being actively researched for various image processing applications including 3-D image constructions, and its most computation-intensive stage is a keypoint localization. In this paper, we develope a fixed-point model of the keypoint localization and propose its efficient hardware architecture for embedded applications. The bit-length of key variables are determined based on two performance measures: localization accuracy and error rate. Comparing with the original algorithm (implemented in Matlab), the accuracy and error rate of the proposed fixed point model are 93.57% and 2.72% respectively. In addition, we found that most of missing keypoints appeared at the edges of an object which are not very important in the case of keypoints matching. We estimate that the hardware implementation will give processing speed of $10{\sim}15\;frame/sec$, while its fixed point implementation on Pentium Core2Duo (2.13 GHz) and ARM9 (400 MHz) takes 10 seconds and one hour each to process a frame.

Medical Professionals' Review of YouTube Videos Pertaining to Exercises for the Constipation Relief (국내 유튜브 영상으로 배포된 변비 완화 운동 콘텐츠의 의료진에 의한 평가)

  • Lee, Tae Hee;Kim, Seong-Eun;Park, Kyung Sik;Shin, Jeong Eun;Park, Seon-Young;Ryu, Han Seung;Kim, Jung-Wook;Lee, Yoo Jin;Cho, Young Sin;Park, Suyeon;Constipation Research Group of The Korean Society of Neurogastroenterology and Motility
    • The Korean Journal of Gastroenterology
    • /
    • v.72 no.6
    • /
    • pp.295-303
    • /
    • 2018
  • Background/Aims: The primary aims of this study were to evaluate the content quality of YouTube videos on exercises to help relieve constipation and to assess whether the video source, exercise types, and popularity affected their quality. Methods: Eight gastroenterologists independently evaluated the exercises presented in the constipation YouTube videos for seven items: image quality, usefulness in relieving constipation (quality 1), usefulness for general physical health (quality 2), difficulty in following, activity intensity, fun, and overall quality. Raters were asked open-ended questions to evaluate the strengths and weaknesses of the videos. Five-point ordinal scales were used to score each item aforementioned, with the exception of image quality and overall quality that used a six-point Likert scale. Results: The 20 videos had a mean length of 268 seconds and a mean viewership of 32,694. The most common video source was commercial (n=10), and the most common type of physical activity was yoga (n=11). The median values of image quality, quality 1, quality 2, difficulty in following, activity intensity, fun, and overall quality were 3, 2, 2, 2, 2, 2, and 2, respectively. Yoga videos had significantly higher median quality 1 values (3) compared with massage videos (2, adjusted p=0.006) and 'others' videos (2, adjusted p<0.001). A lack of medical evidence was the most common answer to open-ended questions about the weaknesses of each video. Conclusions: Overall, YouTube exercise videos presented a low-quality content. This study highlights the need for evidence-based comprehensive educational videos addressing exercises for treating constipation.

The Effects of Different Surface Level on Muscle activity of the Upper Body and Exercise Intensity during Mountain Climbing Exercise (지면에서의 마운틴 클라이밍 운동 시 상체의 위치 변화가 운동 강도와 근활성도에 미치는 영향)

  • Park, Jun-Ho;Jung, Jae-Hu;Kim, Jong-Geun;Chae, Woen-Sik
    • Korean Journal of Applied Biomechanics
    • /
    • v.31 no.1
    • /
    • pp.72-78
    • /
    • 2021
  • Objective: The purpose of this study was to investigate relations and effectiveness about mountain climbling exercise with different level of support surfaces by analyzing heart rate and EMG data. A total of 10 male college students with no musculoskeltal disorder were recruited for this study. Method: The biomechanical analysis was performed using heart rate monitor (Polar V800, Polar Electro Oy, Finland), step-box, exercise mat, and EMG device (QEMG8, Laxtha Inc. Korea, sampling frequency = 1,024 Hz, gain = 1,000, input impedance > 1012 Ω, CMRR > 100 dB). In this research, step-box were used to create different surface levels on the upper body (flat surface, 10% of subject's height, 20% of subject's height, and 30% of subject's hight). Based on these different conditions, data was collected by performing mountain climbing exercise during 30 seconds. Subjects were given 5 minutes of break to prevent muscular fatigue after each exercise. For each dependent variable, a one-way analysis of variance with repeated measures was conducted to find significant differences and Bonferroni post-hoc test was performed. Results: The results of this study showed that exercise intensity was reduced statistically as increased surface level on the upper body. Muscle activity of the upper rectus abdominis and biceps femoris for 30% of surface level was significantly higher than the corresponding values for flat surface. However, the opposite was found in the rectus femoris. In general, muscle activity of the lower rectus abdominis, erector spinae, external oblique abdominis, and gluteus maximus increased when surface level increased, but the differences were not significant. Conclusion: As a result, the increase in surface level of the body would change muscle activity of the upper body, indicating that different surface level of the upper body may cause significant effect on particular muscles to be more active during mountain climbing exercise. Based on results of this study, it is suggested to set up an appropriate surface level to target particular muscle to expect an effective training. It is also important to set adequate surface levels to create an effective training condition for preventing exercise injuries.

In Vitro Effect of 808-nm Diode Laser on Proliferation and Glycosaminoglycan Synthesis of Rabbit Articular Chondrocytes (토끼 관절 연골세포의 증식과 글리코스아미노글리칸 합성에 대한 808-nm 다이오드 레이저의 효능 평가)

  • Minar, Maruf;Hwang, Ya-won;Choi, Seok-hwa;Kim, Gonhyung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.295-300
    • /
    • 2015
  • The aim of the study was to assess the in vitro effect of 808-nm InGaAs diode laser on rabbit articular chondrocyte proliferation and sulphated glycosaminoglycan (sGAG) synthesis in alginate bead. Previous studies revealed either positive or negative stimulatory effects of laser on different types of cells. A 808-nm InGaAs diode laser at 1.0W power output was used to irradiate the rabbit chondrocytes in alginate beads with energy densities of $31J/cm^2$ (G 1) and $62J/cm^2$ (G 2) corresponding to the experimental groups for 10 seconds and 20 seconds, respectively at 24, 48, 72 and 96 hours after seeding. Control group was left untreated. MTT assay was performed at 1 week and 2 weeks after the $1^{st}$ laser irradiation in alginate beads. sGAG synthesis in alginate beads at 1 week and 2 weeks were determined by DMMB assay. Histological evaluation for cellular distribution and sGAG deposition around the cells were performed by alcian blue stain. MTT assay revealed no positive stimulatory effect in cell proliferation in alginate bead. DMMB assay results showed significantly increased sGAG production in G 2 chondrocytes at 2 weeks. Image analysis of alcian blue stained slides also showed significantly higher percentage of positive alcian blue stain in G 2 chondrocytes. This result suggests that 808-nm InGaAs diode laser with 1.0 W power output although cannot stimulate cell proliferation it can increase the cell secretion activity and sGAG deposition in alginate beads.

Adenosine $^{99m}Tc-MIBI$ Scintigraphy in the Diagnosis of Coronary Artery Disease: Comparison with Exercise $^{99m}Tc-MIBI$ Scintigraphy (관상동맥 질환에서의 Adenosine 부하 $^{99m}Tc-MIBI$ 심근 스캔의 진단적 가치 : 운동 부하 $^{99m}Tc-MIBI$ 심근 스캔과의 비교)

  • Kang, Seung-Wan;Woo, Eon-Jo;Chae, Sung-Chull;Jun, Jae-Eun;Park, Wee-Hyun;Chung, Byung-Cheon;Choi, Chung-Il;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.72-81
    • /
    • 1992
  • Pharmacologic coronary vasodilation in conjunction with myocardial scintigraphy has become an accepted alternative to dynamic exercise testing for the diagnosis of coronary artery disease. Although dipyridamole has traditionally been used for this purpose, it causes frequent side effect, which at times can be life-threatening. Moreover, dipyridamole dose not elicit maximal coronary vasodilation in a substantial number of patients receiving the usual i.v. dose. Adenosine is an endogenously produced compound that has significant effects as a coronary vasodilator and rapid onset action and extremely short half-life (< 10 seconds). The diagnostic accuracy and safety profile of adenosine $^{99m}Tc-MIBI$ myocardial scintigraphy were evaluated and comparison with exercise $^{99m}Tc-MIBI$ was performed. Twenty-eight subjects underwent $^{99m}Tc-MIBI$ imaging after adenosine infusion and exercise $^{99m}Tc-MIBI$ imaging. Adenosine was infused intravenously at a dose of 0.14mg/kg/body weight per minute for 6 min and MIBI was injected at 3 minute. Adenosine caused an incerease in heart rate ($64{\pm}12$ at baseline versus $74{\pm}16$ beats/min at peak effect, p<0.001), a mild decrease in systolic and diastolic blood pressure and a slightly increase in PR interval(p; NS). Side effects were reported in 92% of patients and were mostly mild in nature and promptly resolved within 1 or 2 minutes of termination of adenosine infusion. Facial flushing (53%), chest pain (36%), mild dyspnea (39%), headache (21%), throat discomfort (21%) were frequent symptoms. ST segment depression (> 1 mm) and second degree AV block in electrocardiography occured in 11% of the patients, respectively. The overall sensitivity and specificity for individual coronary stenoses in 16 patients underwent coronary angiography were 88% and 95%, respectively. The agreement ratio of segmental perfusion between adenosine and exercise images was 92% (Kappa index=0.82). In conclusion, $^{99m}Tc-MIBI$ myocardial perfusion scintigraphy with intravenous adenosine is a feasible, safe and highly accurate noninvasive technique for the detection of coronary artery disease and results are at least comparable with those of exercise $^{99m}Tc-MIBI$ scintigraphy.

  • PDF