• Title/Summary/Keyword: 7.0 T MRI

Search Result 212, Processing Time 0.032 seconds

Cerebral Infarction Model in Rat on Magnetic Resonance Imaging (흰 쥐의 뇌경색 병변에 대한 자기공명영상)

  • Jung, Ji-Sung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.2
    • /
    • pp.55-58
    • /
    • 2011
  • It is important to study using experimental animals for research about stroke. Magnetic Resonance Imaging(MRI) is avaluable diagnosticmethods for stroke diagnosis. The purpose of this research is to know the Magnetic Resonance Imaging(MRI) and histopathological characteristics findings after induction of photothrombotic cerebral infarction in rat brain. Male Sprague-Dawley rats were anesthetized, Rose Bengal dye(20 mg/kg) was intravenously injected. The right sensonrimotor cortex of rat brain was exposed to cold light of 7 mm diameter at a position of 1 mm anterior and 3.5 mm lateral to bregma for 20 min. The post-infarction effects were monitored by T1 weighted and T2 weighted images of brain MRI. Histopathological changes were observed after Hematoxylin & Eosin staining. The lesion appeared clearly high signal intensity area on T2 weighted images(the major axis $7.04{\pm}0.11$ mm, the minor axis $3.08{\pm}0.04$ mm) and also H&E staining was same result. In conclusion, MRI was avaluable diagnostic methods for diagnosis and serial changes of stroke.

  • PDF

Quantitative Analysis of GBCA Reaction by Mol Concentration Change on MRI Sequence (MRI sequence에 따른 GBCA 몰농도별 반응에 대한 정량적 분석)

  • Jeong, Hyun Keun;Jeong, Hyun Do;Kim, Ho Chul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.2
    • /
    • pp.182-192
    • /
    • 2015
  • In this paper, we introduce how to change the reaction rate as mol concentration when we scan enhanced MRI with GBCA(Gadolinium Based Contrast Agent), Also show the changing patterns depending on diverse MRI sequences which are made by different physical principle. For this study, we made MRI phantom ourselves. We mixed 500 mmol Gadoteridol with Saline in each 28 different containers from 500 to 0 mmol. After that, MR phantom was scanned by physically different MRI sequences which are T1 SE, T2 FLAIR, T1 FLAIR, 3D FLASH, T1 3D SPACE and 3D SPCIR in 1.5T bore. The results were as follows : *T1 Spin echo's Total SI(Signal Intensity) was 15608.7, Max peak was 1352.6 in 1 mmol. *T2 FLAIR's Total SI was 9106.4, Max peak was 0.4 1721.6 in 1 mmol. *T1 FLAIR's Total SI was 20972.5, Max peak was 1604.9 in 1 mmol. *3D FLASH's Total SI was 20924.0, Max peak was 1425.7 in 40 mmol. *3D SPACE 1mm's Total SI was 6399.0, Max peak was 528.3 in 3 mmol. *3D SPACE 5mm's Total SI was 6276.5, Max peak was 514.6 in 2 mmol. *3D SPCIR's Total SI was 1778.8, Max peak was 383.8 in 0.4 mmol. In most sequences, High signal intensity was shown in diluted lower concentration rather than high concentration, And also graph's max peak and pattern had difference value according to the each different sequence. Through this paper which have quantitative result of GBCA's reaction rate depending on sequence, We expect that practical enhanced MR protocol can be performed in clinical field.

Using a 7.0T animal MRI comparison of ADC values and Pathologic Findings (7.0T 동물용 MRI을 이용한 종양의 현성확산계수와 병리학적 소견의 평가)

  • Seong, jae gu;Lim, cheong hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.201-202
    • /
    • 2011
  • 본 연구에는 7.0T 동물용 자기공명영상장치를 이용하여 인간의 췌장암 세포인 CFPAC-1를 이종 이식한 쥐에서 자기공명영상을 획득하여 최적화된 검사 Protocol을 정립하며, 동물 실험에서 밝혀진 종양특성과 확산강조영상과의 비교 분석을 해보고 현성확산계수 영상이 췌장암 이종이식 모형의 종양 세포 내부 구조에 관하여 어떠한 정보를 제공 할 수 있는지 알아보고자 한다. 13마리의 쥐의 26개의 종양을 전형적으로 주입 후에 2~4주 뒤에 직경이 5~10mm가 되었을 때 imaged 하였으며, pathologic specimenm을 위해 sacrificed 하였다. isofluoran gas anesthesia를 이용하여 동물 마취 하였다. 사용된 장비로는 small-animal MR images (7.0-T)를 (Bruker BioSpin GmbH, Rheinstetten, Germany)이용하여 Fast T2-weighted 와 single-shot EPI DW image를 얻었다. 종양은 H&E 염색과 CD31와 VEGF에 대한 면역조직학 염색을 하여 종양의 cellularity와 microvessel density(MVD), 종양 내 괴사 정도를 평가하였다. CFPAC-1의 현성확산계수값은 $0.7327{\pm}0.1075{\pm}10^{-3}mm2/s$이였으며, 현성확산계수는 종양내 괴사 정도와 연관성을 보였다(R = 0.7417, p = 0.0001) 이처럼 현성확산계수는 종양 내 괴사 정도 등의 현미경적구조변화를 반영하는 대리인자로 사용될 수 있음을 확인하였다.

  • PDF

Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging (자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가)

  • Jung-Whan Min;Hoi-Woun Jeong
    • Journal of radiological science and technology
    • /
    • v.47 no.1
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

Effects of Gadolinium Contrast agent on Bone Mineral Density Measurement using Dual Energy X-ray Absorptiometry (가돌리늄조영제가 이중에너지 X-선 흡수법을 이용한 골밀도검사에 미치는 영향)

  • Lee, Keun-Ohk;Lee, Min-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.1
    • /
    • pp.63-70
    • /
    • 2021
  • Radiographic contrast agents are used for diagnostic purposes and are one of the factors affecting measured values in bone density tests. They are absorbed into tissues and have an effect of increasing the measured values of bone density, so they are avoided as much as possible before performing a bone density test. MRI contrast agents, which have different physical properties and mechanisms of action than radiographic contrast agents, are based on gadolinium, a metal element. They have radiopacity characteristics, so MRI are generally performed prior to examination using radiation. The purpose of this study was to investigate the effects of MRI contrast agents on bone mineral density examination using dual energy X-ray absorption. Two types of gadolinium based MRI contrast agents were injected into an acrylic water tank for each volume, and the humanoid spine phantom was inserted and the BMD and T-score from (L1-L4) were analyzed by scanning a total of 30 times, 5 times for each injection type. The average value of the measured total (L1-L4) bone density for each of the two contrast agents was 0.952±0.052, 0.957±0.050, and 0.956±0.05g/㎠, respectively, for the Gadoterate Meglumine component 0mL, 7.5mL and 15mL, when the gadobutrol components were 0mL, 5mL, and 10mL, there was no statistically significant difference at all sites at 0.953±0.001, 0.954±0.001, and 0.945±0.001g/㎠, respectively(p>0.05). The average value of total T-score was -0.46±0.05, -0.4±0, -0.42±0.04 when the Gadoterate Meglumine component was 0mL, 7.5mL and 15mL, respectively. When the Gadobutrol ingredients were 0mL, 5mL and 10mL, there was no statistically significant difference in all areas, with -0.46±0.05, -0.46±0.05, and 0.5±0.00, respectively. In this experiment, the MRI contrast agent was found to have no effect on bone density tests, using the dual-energy X-ray absorption method. There is a limitation in that physical conditions such as kidney and health conditions etc. were not taken into consideration, so further clinical research is expected to be conducted in the future.

Optimal Echo phase of FLASH sequence for Brain Enhancement scan of mouse at 9.4T MRI system (9.4T MRI FLASH Sequence에서 마우스의 뇌 조영증강 검사를 위한 적정 Echo phase)

  • Jeong, Hyunkeun;Kim, Mingi;Nam, Kichang;Jung, Hyundo;Ahn, Chigwon;Kim, Hochul
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.7
    • /
    • pp.115-124
    • /
    • 2017
  • The objective of study was to investigate the optimal echo phase for mouse brain enhancement scan using fast low angle shot (FLASH) sequence of 9.4T magnetic resonance imaging (MRI). For quantification based on this method, an MR phantom experiment and clinical research were done. The phantom experiment was conducted by fabricating three phantoms with different molar concentration of gadolinium to create changes in echo phase of 9.4T FLASH sequence used in mouse brain scans. In the phantom experiment, SSI was 25~27 [arbitrary units, a.u.] in each of 33 phases from $6{\pi}$ to $28{\pi}$, while RSP was 30~100 mmol. MPSI was 47~52 [a.u], while MPP, where MPSI is seen, was 0.8~9 mmol. EPMS was 80.8~108.0%, while ASIMP was formed between 21.1 and 31.8 [a.u]. In the clinical research, Finally, the occurrence rate of artifact that expressed -1 nd +1. The present study was able to quantify the degree of enhancement at FLASH sequence of 9.4T MRI, as well as identify the optimal echo phase during mouse brain enhancement scan.

Relationship between anterior disc displacement with/without reduction and effusion in temporomandibular disorder patients using magnetic resonance imaging

  • Koh, Kwang-Joon;Park, Ha-Na;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • v.43 no.4
    • /
    • pp.245-251
    • /
    • 2013
  • Purpose: This study was performed to evaluate the relationship between anterior disc displacement and effusion in temporomandibular disorder (TMD) patients using magnetic resonance imaging (MRI). Materials and Methods: The study subjects included 253 TMD patients. MRI examinations were performed using a 1.5 T MRI scanner. T1- and T2-weighted images with para-sagittal and para-coronal images were obtained. According to the MRI findings, temporomandibular joint (TMJ) disc positions were divided into 3 subgroups: normal, anterior disc displacement with reduction (DWR), and anterior disc displacement without reduction (DWOR). The cases of effusion were divided into 4 groups: normal, mild (E1), moderate (E2), and marked effusion (E3). Statistical analysis was made by the Fisher's exact test using SPSS (version 12.0, SPSS Inc., Chicago, IL, USA). Results: The subjects consisted of 62 males and 191 females with a mean age of 28.5 years. Of the 253 patients, T1- and T2-weighted images revealed 34 (13.4%) normal, DWR in 103 (40.7%), and DWOR in 116 (45.9%) on the right side and 37 (14.6%) normal, DWR in 94 (37.2%), and DWOR in 122 (48.2%) joints on the left side. Also, T2-images revealed 82 (32.4%) normal, 78 (30.8%) E1, 51 (20.2%) E2, and 42 (16.6%) E3 joints on the right side and 79 (31.2%) normal, 85 (33.6%) E1, 57 (22.5%) E2, and 32 (12.7%) E3 on the left side. There was no difference between the right and left side. Conclusion: Anterior disc displacement was not related to the MRI findings of effusion in TMD patients (P>0.05).

Diagnosis of Hepatocellular Carcinoma Using C-11 Choline PET/CT: Comparison with F-18 FDG, Contrast-Enhanced MRI and MDCT

  • Chotipanich, Chanisa;Kunawudhi, Anchisa;Promteangtrong, Chetsadaporn;Tungsuppawattanakit, Puntira;Sricharunrat, Thaniya;Wongsa, Paramest
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.7
    • /
    • pp.3569-3573
    • /
    • 2016
  • Purpose: The aim of this study was to compare C-11 choline and F-18 FDG PET/CT, gadoxetic-enhanced 3-T MRI and contrast-enhanced CT for diagnosis of hepatocellular carcinoma (HCC). Materials and Methods: Twelve chronic hepatitis B patients suspected of having HCC by abdominal ultrasonography received all diagnostic modalities performed within a one-week timeslot. PET/CT results were analyzed visually by two independent nuclear medicine physicians and quantitatively by tumor to background ratio (T/B). Nine patients then had histopathological confirmation. Results: Six patients had well differentiated HCC, while two and one patient(s) were noted with moderately and poorly differentiated HCC, respectively. All were detected by both CT and MRI with an average tumor size of $5.7{\pm}3.8cm$. Five patients had positive C-11 choline and F-18 FDG uptake. Of the remaining four patients, three with well differentiated HCC showed negative F-FDG uptake (one of which showed negative results by both tracers) and one patient with moderately differentiated HCC demonstrated no C-11 choline uptake despite intense F-18 FDG avidity. The overall HCC detection rates with C-11 choline and F-18 FDG were 78% and 67%, respectively, while the sensitivity of F-18 FDG for non-well differentiated HCC was 100%, compared with 83% of C-11 choline. The average T/B of C-11 choline in well-differentiated HCC patients was higher than in moderately and poorly differentiated cases (p=0.5) and vice versa with statistical significance for T/B of F-18 FDG (p = 0.02). Conclusions: Our results suggested better detection rate in C-11 choline for well differentiated HCC than F-18 FDG PET. However, the overall detection rate of PET/CT with both tracers could not compare with contrast-enhanced CT and MRI.

Evaluation of Renal Oxygenation in Normal Korean Volunteers Using 3.0 T Blood Oxygen Level-Dependent MRI (3.0 T 혈중산소치의존 자기공명영상을 이용한 정상한국인에서의 신장 산소공급의 평가)

  • Hwang, Sung Il;Lee, Hak Jong;Chin, Ho Jun;Chae, Dong-Wan;Na, Ki Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.1
    • /
    • pp.19-25
    • /
    • 2013
  • Purpose : Renal blood oxygen level-dependent (BOLD) MRI has been used in the evaluation of renal oxygenation. We tried to provide the normal $R2^*$ value of the human kidney with 3.0 T, and evaluated the differences in $R2^*$ values according to gender and location. Materials and Methods: Twenty-four healthy volunteers underwent BOLD MRI at 3.0 T. Multi gradient echo-echo planar imaging sequence with seventeen echoes was used. After generation of the $T2^*$ map, the $R2^*$ was calculated. The statistical differences in $R2^*$ values between the cortex and medulla, males and females, and the right and left kidney were analyzed. The regional differences of $R2^*$ within the both kidneys were evaluated respectively. Results: BOLD MRI was successful in all participants. No gross artifact interfered with $R2^*$ measurement. The mean $R2^*$ at 3.0 T was $17.1{\pm}2.60s^{-1}$ in the cortex and $27.7{\pm}4.83s^{-1}$ in the medulla (p < 0.001). The $R2^*$ value in the medulla was significantly higher in the male than female volunteers (p = 0.025). There were no statistical differences of $R2^*$ according to the side and location in the kidney (p = 0.197). Conclusion: Renal BOLD MRI can be efficiently performed with 3.0 T MRI. Renal medullary hypoxia is present in normal volunteers. Our results may be used as reference values in the evaluation of pathologic conditions using BOLD MRI.

Clinical Experience with 3.0 T MR for Cardiac Imaging in Patients: Comparison to 1.5 T using Individually Optimized Imaging Protocols (장비 별 최적화된 영상 프로토콜을 이용한 환자에서의 3.0T 심장 자기공명영상의 임상경험: 1.5 T 자기공명영상과의 비교)

  • Ko, Jeong Min;Jung, Jung Im;Lee, Bae Young
    • Investigative Magnetic Resonance Imaging
    • /
    • v.17 no.2
    • /
    • pp.83-90
    • /
    • 2013
  • Purpose : To report our clinical experience with cardiac 3.0 T MRI in patients compared with 1.5 T using individually optimized imaging protocols. Materials and Methods: We retrospectively reviewed 30 consecutive patients and 20 consecutive patients who underwent 1.5 T and 3 T cardiac MRI within 10 months. A comparison study was performed by measuring the signal-to-noise ratio (SNR), the contrast-to-noise ratio (CNR) and the image quality (by grading each sequence on a 5-point scale, regarding the presence of artifacts). Results: In morphologic and viability studies, the use of 3.0 T provided increase of the baseline SNRs and CNRs, respectively (T1: SNR 29%, p < 0.001, CNR 37%, p < 0.001; T2-SPAIR: SNR 13%, p = 0.068, CNR 18%, p = 0.059; viability imaging: SNR 45%, p = 0.017, CNR 37%, p = 0.135) without significant impairment of the image quality (T1: $3.8{\pm}0.9$ vs. $3.9{\pm}0.7$, p = 0.438; T2-SPAIR: $3.8{\pm}0.9$ vs. $3.9{\pm}0.5$, p = 0.744; viability imaging: $4.5{\pm}0.8$ vs. $4.7{\pm}0.6$, p = 0.254). Although the image qualities of 3.0 T functional cine images were slightly lower than those of 1.5 T images ($3.6{\pm}0.7$ vs. $4.2{\pm}0.6$, p < 0.001), the mean SNR and CNR at 3.0 T were significantly improved (SNR 143% increase, CNR 108% increase, p < 0.001). With our imaging protocol for 3.0 T perfusion imaging, there was an insignificant decrease in the SNR (11% decrease, p = 0.172) and CNR (7% decrease, p = 0.638). However, the overall image quality was significantly improved ($4.6{\pm}0.5$ vs. $4.0{\pm}0.8$, p = 0.006). Conclusion: With our experience, 3.0 T MRI was shown to be feasible for the routine assessment of cardiac imaging.