• Title/Summary/Keyword: 6mm Digital Camera

Search Result 28, Processing Time 0.028 seconds

Analysis of Stone′s Surface Roughness Measurement Accuracy of a High Resolution Digital Camera by Digital Close-Range Photogrammetry (수치근접사진측량에 의한 고해상도 디지털 카메라의 석재표면 거칠기 측정정확도 파악)

  • 안기원;이효성;유주현
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2000
  • This study aims to analyze stone's surface roughness measurement accuracy of a high resolution DCS 420 digital camera by digital close-range photogrammetric technique. For this purpose, the surface roughness measurement system was constructed by means of microsoft visual basic 6.0 in windows. As the analysis results of measurement accuracy of digital camera using this system, the roughness error of the normal distance between the best fitting reference surface obtained by least square method and sample points in the ideal plane or surface did not exceed $\pm$0.1 mm

  • PDF

Development of Gamma Camera System for Small Animal Imaging and Environmental Radiation Detection (소동물 영상화 및 환경 방사선 검출을 위한 감마카메라 개발)

  • Baek, Cheol-Ha
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.2
    • /
    • pp.475-481
    • /
    • 2014
  • The aim of this work was to develop the gamma camera system for small animal gamma imaging and environmental radiation monitoring imaging using a parallel hole collimator and pinhole collimator. The small gamma camera system consists of a CsI(Tl) scintillation crystal with 6 mm in thickness and $50{\times}50mm$ in area coupled with a Hamamatsu H8500C PSPMT, are resistive charge divider, pre-amplifiers, charge amplifiers, nuclear instrument modules (NIMs), an analog to digital converter and a computer for control and display. We have developed a radiation monitoring system composed of a combined pinhole gamma camera and a charge-coupled devices (CCD) camera. The results demonstrated that the parallel hole collimator and pinhole collimator gamma camera designed in this study could be utilized to perform small animal imaging and environmental radiation monitoring system. Consequently in this paper, we proved that our gamma detector system is reliable for a gamma camera which can be used as small animal imaging and environmental radiation monitoring system.

On Production System by One-Person Production System in Broadcasting Program Production (방송프로그램제작에 있어 1인 제작시스템 변화)

  • Lee, Jong-Tak;Kwak, Hoon-Sung
    • The Journal of the Korea Contents Association
    • /
    • v.7 no.8
    • /
    • pp.117-124
    • /
    • 2007
  • The one-person producing system is that planning program, arrangements, composition, taking pictures and edition are all done by only one person. In the reality of the producing systems of the broadcasting programs, as the number of the broadcasting stations, which apply one-person producing systems, is gradually increasing, the study on the change is going on. In this study I grasped the merits and demerits of both systems ; multi men producing system and one-person producing system. And then I analyzed the sudden change of the method of the producing programs into one using the 6m digital camera. The merits of producing programs by means of the 6m digital cameras are following ; the mobility of producing programs, a close contact with the source, the enlargement of the diversity of the contents and cutting down expenses. The demerits of it are following ; a lowering of the degree of completion and the unstableness of an image. Nowadays because of the enlargement of the rate of the outsourcing production, the number of the independent production studios rapidly increased. From the viewpoint of cutting down expenses and the diversity of contents, the number of broadcasting programs produced by means of one-person producing broadcasting program system is increasing.

Applying DSLR Camera for Measuring the Deflection of Concrete Beam (DSLR 카메라를 활용한 콘크리트 보의 변형 측정)

  • Lee, Byoung-Kil
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.28 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • Measurements of deflection in load testing of structures are typically obtained with contact instrumentations such as LVDT (Linear-Variable Differential Transformer). LVDT only measure 1-dimensional deformation and in destructive testing is damage to instrumentation, thus prohibiting deflection when the beam is close to failure. Measurements of deflection using non-metric digital cameras are useful for load testing because there are very little cost or beam failure except for cheap targets and measurements in 3-dimensional deflection can obtained rapidly. In this research, deflection of concrete beam was measured using Nikon D80 DSLR camera, and the accuracy was evaluated with comparing the outputs to the LVDT measurements. The results show that the accuracy of terrestrial photogrammetric measurements are ${\pm}$0.5mm, ${\pm}$0.5mm, ${\pm}$0.6mm for each X, Y, Z directions, and the RMSE of comparison to LVDT is ${\pm}$0.57mm.

A Study on Combustion Patterns of Flammable Liquids by Contained Oil Test (담유 실험에 의한 인화성 액체의 연소 패턴 해석에 관한 연구)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.28 no.4
    • /
    • pp.14-20
    • /
    • 2014
  • The purpose of this study is to analyze combustion patterns by filling a specific container with a flammable liquid and performing combustion tests in a divided space. The container used for the test is made of plastic, 20 mm in depth and 150 mm in width. After the liquid was ignited, its combustion process was photographed using a digital camera and video camera. It was found that in the case of benzene, the flame reached its peak at the fastest speed about 60 s while in the case of alcohol, the flame reached its peak at the lowest speed about 360 s, which is approximately six times slower than the benzene. In most cases, when the flame reached its peak, smoke generated was dark as the plastic container and flammable liquid were combusted simultaneously. After completion of the combustion, it was possible to sample oil vapor from all flammable liquids excluding soybean oil as a result of the examination of oil vapor using a crime investigation tube. That is, it can be seen that there is significant difference in flame propagation speed, pattern, etc., depending on the combustible substances.

Zoom lens design for compact digital camera using lens modules (렌즈모듈을 이용한 컴팩트 디지털 카메라용 줌 렌즈 설계)

  • Park, Sung-Chan;Lee, Sang-Hun
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.1
    • /
    • pp.34-42
    • /
    • 2005
  • This paper presents the optimum initial design containing the first and third order properties of the three-group zoom system using lens modules, and the real lens design of the system. The optimum initial design with focal length range of 4.3 mm to 8.6 mm is derived by assigning appropriate first and third order quantities to each module along with the specific constraints required for the system. An initial real lens selected for each group has been designed to match its focal length and the first orders into those of the each lens modules, and then combined to establish an actual zoom system by adjusting the air space between the groups at all zoom positions. The combination of the separately designed groups results in a system which satisfies the first order properties of the zoom system composed of the original lens modules. As a result, by residual aberration correction, we could obtain a zoom system useful in compact digital zoom cameras and mobile phone cameras employing the rear focus method.

The Historical Transition of Handheld Camera (핸드헬드 카메라의 변화에 관한 소고)

  • Chin, Vitnam
    • Trans-
    • /
    • v.6
    • /
    • pp.79-95
    • /
    • 2019
  • The advent of the handheld camera has dramatically transformed film production and consumption in countless ways. French director and theorist, Alexandre Astruc focuses on the development of 16mm camera and foretell film will be used as a tool to realize the personal vision of the author like other art. As proof of his claim French New Wave and Cinéma vérité create the film with handheld camera on the real location to capture new reality. Their films are distinguished itself from other films made by conventional Hollywood studios. Similarly, John Cassavetes in the United States began to focus on the handheld camera. Since then the handheld camera has become one of the popular shooting methods. Especially, handheld camera are noted for their agile movement and mobility as a way to capture various realities. However, with the advances in technology, lighter cameras and higher resolution have changed in different ways. The technology is neutral, one shooting method does not serve for one philosophy or ism. At one time, handheld shooting is now used as not only a means to capture the real world but also a tool to mimic a realistic feeling.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Measurement of Breakup Length of Viscous Liquid Jet in Stagnant Air (정지공기중 점성유체 분류의 분열길이 측정)

  • Rhim, Jung-Hyun;Ryu, Keun-Young;Lim, Sung-Bin;No, Soo-Young
    • Journal of ILASS-Korea
    • /
    • v.3 no.4
    • /
    • pp.1-7
    • /
    • 1998
  • The measurement of breakup length of viscous liquid jet in stagnant air was conducted by a 3CCD digital video camera. The nozzle diameters of 4, 6, 8mm with L/d=50 were selected and the dynamic viscosity of viscous liquid made of glycerine and water was in the range of $1.061\times10^{-6}m^2/s$ to $4.935\times10^{-5}m^2/s$. The critical velocity is decreased and the breakup length is increased with the increase of nozzle diameter at the same dynamic viscosity of liquid. At the same nozzle diameter, the breakup length and the critical velocity are both increased with the increase of dynamic viscosity of liquid. It is found in the theoretical analysis that the initial disturbance level is the main cause of occurrance of critical Reynolds number in the stability curve. The comparison of experimental critical Reynolds number and the empirical correlation by Tanasawa and Toyota reveals the relatively good agreement.

  • PDF

Comparison of SPECT Images with $^{99m}Tc$ Collimators ($^{99m}Tc$용 콜리메타의 성능과 SPECT 화상의 영향)

  • Lee, Man-Koo;Lee, Jeong-Ok;Park, Soung-Ock
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.35-40
    • /
    • 2001
  • Performance of SPECT imaging systems which use a rotating gamma camera, are affected by characteristics of the detector-collimator assembly, the data acquisition method, and the filter used in imaging reconstruction. The purpose of this study Is to examine image qualifies of SPECT with different types of low energy collimators. The SPECT imaging system in this study is a digital gamma camera system GCA-901A(Toshiba) and a data processing unit Scintipac-700(Shimadzu). The four types of collimators compared are UHR(ultra high resolution), LEHR(low energy high resolution), LEGP(low energy general purpose), and I-123 PAR(Parallel), with 0.27, 0.66, 1.00, and 2.06 relative sensitivity, respectively. In this case of the same collimators, the spatial resolutions measured in the slice plane showed a slight difference in the FWHM values(mean values of UHR, LEHR, LEGP, and I-123 PAR were 11.3 mm, 13.6 mm, 15.8 mm, and 20.4 mm, respectively) between the center and the circumference of the field of view, in the radial direction, but a large difference in the tangential direction, with lower FWHM values(values of UHR, LEHR, LEGP, and I-123 PAR were 8.4 mm, 8.7 mm, 9.3 mm, and 10.8 mm at 12 cm from the center, respectively). In comparison of SPECT images with the four types of collimators, except for the I-123 PAR collimator, image qualities of UHR, LEHR, and LEGP collimators showed only a slight difference. From the point of for, it is expected that the LEGP collimator would be suitable for SPECT imaging with $^{99m}Tc$.

  • PDF