• Title/Summary/Keyword: 60Hz

Search Result 1,300, Processing Time 0.026 seconds

Design of a 60 Hz Band Rejection FilterInsensitive to Component Tolerances (부품 허용 오차에 둔감한 60Hz 대역 억제 필터 설계)

  • Cheon, Jimin
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.15 no.2
    • /
    • pp.109-116
    • /
    • 2022
  • In this paper, we propose a band rejection filter (BRF) with a state variable filter (SVF) structure to effectively remove the influence of 60 Hz line frequency noise introduced into the sensor system. The conventional BRF of the SVF structure uses an additional operational amplifier (OPAMP) to add a low pass filter (LPF) output and a high pass filter (HPF) output or an input signal and a band pass filter. Therefore, the notch frequency and the notch depth that determine the signal attenuation of the BRF greatly depend on the tolerance of the resistors used to obtain the sum or difference of the signals. On the other hand, in the proposed BRF, since the BRF output is formed naturally within the SVF structure, there is no need for a combination between each port. The notch frequency of the proposed BRF is 59.99 Hz, and it can be confirmed that it is not affected at all by the tolerance of the resistor through the Monte Carlo simulation results. The notch depth also has an average of -42.54dB and a standard deviation of 0.63dB, confirming that normal operation as a BRF is possible. Also, with the proposed BRF, noise filtering was applied to the electrocardiogram (ECG) signal that interfered with 60 Hz noise, and it was confirmed that the 60 Hz noise was appropriately suppressed.

A Study on the Characteristics of Echolocation Signals of the Common Dolphin, Delphinus Delphis (참돌고래의 반향정위 신호특성에 관한 연구)

  • 신형일;윤갑동;신현옥;최한규;박태건
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.3
    • /
    • pp.189-195
    • /
    • 2001
  • The characteristics of echolocation signals of the Common Dolphin, Delphinus Delphis was observed by the hydrophone in order to detect exactly distribution and migration on whales and dolphins in Korean Coastal waters. It's observation was carried out at the position of 13 mm off Gam-Po of Korean east-southern sea at 3rd-5th. April and 13th-15th. October, 1999. The results obtained are summarized as follows: (1) The frequency range of ship's noise and ambient noise in the observed station was 0.5-0.3 kHz, that ones could be influenced to the behavior of common dolphins which carry out echolocation using low-frequency. (2) The common dolphin was radiated single click of 8.6 ms and double click of 4.8 ms pulse width during these observation (3) The high click frequencies of common dolphin were 5.10 kHz, 7.22 kHz, 10.60 kHz with the click pulse width of 4.0 ms, 2.6 ms, 1.0 ms, respectively. In case of low-frequency 1-2 kHz, that is, 1.12 kHz, 1.38 kHz, 1.82 kHz, pulse width were 22.4 ms, 2.05 ms, 11.9 ms, respectively and they showed a tendency using triple click signal. (4) The pulse width, pulse recurrence interval and frequency range of the observed echolocation signals were 2.4-8.4 ms, 9.0-40.0 ms, 0.60-10.63 kHz respectively, and frequency spectrum level was 100-125 dB for single, double, triple click signals.

  • PDF

Development of High Frequency Active Filter for Multimedia (멀티미디어용 고주파 Active Filter개발에 관한 연구)

  • 윤종남
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.9 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • The purpose of this work is to develop High-Frequency Active Filter and super-miniaturation technology(SMD Type) of Filter which are essential for the key R/F Microwave components in the Mobile telecommunication system. The cut-off frequency of high frequency active filter for multimedia is 2.5 MHz, the gain is 0.5dB at 100 kHz, the passband ripple is 1.2 dB max at 100 kHz~2.0 kHz, GDT is 60 nsec at 100 kHz-2.0 MHz, the attenuation is 40 dB min at 3.75 MHz.

  • PDF

A Design of Driving Circuit for Microwave oven using Phase-shifted FB-ZVS PWM Switching (Phase-shifted FB-ZVS PWM 스위칭을 이용한 Micorwave oven 구동회로 설계)

  • 이완윤;정교범;신판석
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.3
    • /
    • pp.265-272
    • /
    • 2001
  • The traditional 60[Hz] power supply for during magnetron in microwave oven has disadvantages of heavy weight and low efficiency due to 60[Hz] High Voltage Transformer(HVT), capacitor and th phase control of thyristors. To alleviate these disadvantages, this paper proposes a 20[kHz] phase-shifted Full-Bridge(FB) Zero-Voltage-Switched(ZVS) PWM converter for driving a 600[W] magnetron in an 1[kW] microwave oven. The proposed converter has advantages of light weight and high power density.

  • PDF

A Study on Emission Property of Powder Electroluminescent Device at Common use Frequency(60Hz) (상용주파수(60Hz)에서의 후막 전계광소자의 발광 특성에 관한 연구)

  • Oh, Joo-Youl;Park, Young-Soon;Jeong, Byoung-Sun;Lee, Jong-Chan;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.11c
    • /
    • pp.779-782
    • /
    • 1998
  • Electroluminescence is occurred by electric filed located in the phosphor. Until now most of EL researched have been studied the characteristics of devices that drive over 400Hz and commercialized, but in Problems of life time, natural aging increased with behavior of high frequency in the phosphor. In this paper, we investigated the luminescence characteristics were driven by low frequency($0{\sim}100Hz$). Moreover, we Presented the improvement way in the method device production and drive power as measurement at commercial frequency(60Hz).

  • PDF

A study on the Development of Transducer Detecting Infrasonic (초저주파를 검출하는 변환기의 개발에 대한 연구)

  • 이성백;김재환;강영창;이준웅
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.6 no.1
    • /
    • pp.45-50
    • /
    • 1981
  • Infrasonic transducer made with dielectric materials, such as polytetrafluoroethyleme(PTFE)film. The experimental result obtained that the response is within $\pm$1.5dB from 0.1Hz to 7KHz, and that sensitivities of typical transducer are fixed -60dB. The time constant of the transducer at room temperature is over 60 years, and the activation energy of the value of 1.1eV at 343K acquired. This transducer can have application to high-quality communication system, seismological observation etc.

  • PDF

A Study on the Elimination of 60Hz Powerline Inteirference for the Automated Diagnosis of Electrocsrdiogram (심전도 자동진단을 위한 60Hz 전원잡음 제거 필터에 관한 연구)

  • Kweon, Hyukje;Jeong, Keesam;Lee, Myoungho
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.99-108
    • /
    • 1996
  • Diverse digital filters have been designed previously to eliminate powerline(AC) interference in the electrocardiouam. This paper describes filtering methods which have been developed recursive notch, adaptive, IEF(Incremental Estimation Filter) and proposes a new AIEF(Advanced Incremental Estimation Filter) method. The performances of these filters are compared on artificial signals as well as actual ECG signals with the aid of validated CSE(Common Standards for Quantitative Electrocardiowaphy). AC interference in this database is shown to exhibit two qualities especially relevant to filter design : considerable deviations from a nominal 60Hz frequency and substantial noise at higher harmonics.

  • PDF

Immuno-regulatory Activities of Various Fractions from Ehpedrae Sinica STAPF, Rubus Coreanus Miq. and Angelica gigas Nakai Extracts with Ultrasonification (초음파 병행 추출을 이용한 마황과 복분자, 당귀 분획물의 면역활성 조절 효과)

  • Kim, Jung-Hwa;Kim, Dae-Ho;You, Jin-Hyun;Kim, Cheol-Hee;Kwon, Min-Chul;Seong, Nak-Sul;Lee, Seung-Eun;Lee, Hyeon-Yong
    • Korean Journal of Medicinal Crop Science
    • /
    • v.13 no.4
    • /
    • pp.161-170
    • /
    • 2005
  • This study was performed to examine immuno-regulatory activities of Ehpedrae Sinica STAPF, Rubus Coreanus Miq. and Angelica gigas Nakai extracts in conbination with ultrasonification. The extract yields of plants were the highest in the extraction system of $60^{\circ}C$ and 40 kHz of ultrasonification. The immune cell growth ratio of human immune B and T cells was increased compared to other fractions by the water fraction of the plants at $60^{\circ}C$ and 40 kHz. The water fractions of the plants at $60^{\circ}C$ and 40 kHz increased the specific secretion of IL-6 and $TNF-{\alpha}$ of human immune B and T cells compared to other fractions of the plants. The water fraction of Ehpedrae Sinica STAPF among the plants was observed to show the highest specific secretion of IL-6 and $TNF-{\alpha}$. Also, NK-92 MI cells growth was increased in adding the water fractions of the plants at $60^{\circ}C$ and 40 kHz. The water fraction of Ehpedrae Sinica STAPF among the plants showed the highest in NK-92 MI cell growth ratio. The differentiation activity of the HL-60 cells significantly increased in adding the water fraction of Ehpedrae Sinica STAPF compared to other fractions of the plants. These results suggest that the water fractions of the plants in extraction system of temperature $60^{\circ}C$ and ultrasonification 40 kHz have marked useful immuno-stimulatory activities.

Developments of Low Frequency Electric Field Sensor using $Ti:LiMbO_3$ Optical Modulator ($Ti:LiMbO_3$ 광변조기를 이용한 저주파 전계센서의 개발)

  • Choi, Young-Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.4
    • /
    • pp.214-221
    • /
    • 2001
  • The use of an asymmetric Mach-Zehnder interferometric amplitude modulator to measure a relatively low frequency electric field strength is described. The sensitivity of an electric field sensor using a $Ti:LiMbO_3$ optical modulator is strongly affected by the shape of a electrode(probe antenna). To measure the low frequency electric field, a probe antenna of wide effective area is more useful than the usual dipole antenna. As a proof of this, the optical modulator was fabricated with a plate-type probe antenna and the usefulness of this antenna tested for measuring low frequency electric field strength. Measurements were performed in the range 0.1 V/cm to 60 V/cm at 60Hz through 100 kHz. Using a probe antenna of $10\;mm{\times}10\;mm$, the output voltage of $10^{-2}\;mV$ was measured with respect to the electric field strength of 0.1 V/cm at 60 Hz. By increasing the effective area of the probe antenna, better sensitivity is obtainable over the measured range.

  • PDF

A Study on the Operational Characteristics of $CO_2$ Laser Excited by 60Hz AC Discharges (상용주파수 교류방전 $CO_2$ 레이저의 동작 특성)

  • Lee, Dong-Hoon;Im, Kyu-Ho;Jeong, Hyun-Ju;Kim, Hee-Je;Jo, Jung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.8
    • /
    • pp.587-590
    • /
    • 1999
  • In this study, it is the purpose to develope a cheap and compact $CO_2$ laser and to apply 60 Hz AC discharges as a new exciting source. An axial and water cooledtype was adopted as the laser mode. The laser performance characteristics as various parameters, such as gas pressure and discharge current, have been investigated. And the laser output and the efficiency of DC and 60 Hz AC discharge-exciting type have been measured and compared for the different input powers at the static operational pressure. As a result, the case of 60 Hz AC discharge-exciting type, the laser oscillation began at the condition of operational pressure 6 Torr and discharge current 5 mA. A maximum laser output of about 32 W was obtained at an operational pressure of 18 Toorr and a discharge current of 30 mA. In addition, the laser output was saturated from an operational pressure of about 14 Torr and a discharge current of about 20 mA. In this $CO_2$ laser, the laser output of 60 Hz AC discharge-exciting type was slightly higher than that of DC discharge-exciting type. And the laser efficiency was about 10 to 13% for the various operational pressures and the discharge currents.

  • PDF