• Title/Summary/Keyword: 6-Components Measurement

Search Result 330, Processing Time 0.028 seconds

A study on multi degrees of freedom fine motion measurement for milli-structure (밀리구조물의 다자유도 미세 변위 측정법에 대한 연구)

  • 배의원;김종안;김수현;곽윤근
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2000.11a
    • /
    • pp.39-42
    • /
    • 2000
  • Cutrent technological development toward miniaturization requires smaller components. These components usually generate complex multi-DOF motions other than simple 1-DOF motlon. Therefore it is essential to develop measurement methodology for 6-DOF motions. In this paper, a new 6-DOF measurement system for milli-struchlre is presented. This methodology basically employs the Optical Beam Deflection Method (OBDM) with a diffraction grating. A laser beam is emitted toward the difliaction grating which could be attached on the surface of a milli-structue and the incident ray is dif'||'&'||'acted in several directions. Among these difliacted beams, $0^{th}$ and $\pm$ $1^{th}4" order difkicted rays are detected by 4 Quadrant Photodiodes. From coordinate values fram each detector, we can get information for 6-DOF motions with lineariration method, Required resolutions for milli-struchue measurement are suh-micrometer in translation and arcsec in rotation. Experimental results indicate that proposed system has possibility to satisfy this requirement.

  • PDF

A Study on the PD Measurement System for Estimating Reliabilities of Low-voltage Electrical and Electronic Components (저압용 전기전자부품의 신뢰성 평가를 위한 부분방전 측정시스템에 관한 연구)

  • Seo, Hwang-Dong;Snog, Jae-Yong;Moon, Seung-Bo;Kil, Gyung-Suk;Kang, Dong-Sik;Hwang, Don-Ha
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.321-322
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement system that has been accepted as an effective and non-destructive technique for estimating reliabilities of low-voltage electrical and electronic components. Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 37.6 mv/pC. In an application test on photo coupler, we could detect 0.1 pC level of partial discharge at the applied voltage of AC 520 $V_{peak}$.

  • PDF

A Study on Relationship between Halitosis Causing Factors and Components (구취 유발요인과 성분 간의 관계 연구)

  • Ji, Min-Gyeong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.8 no.12
    • /
    • pp.1971-1978
    • /
    • 2013
  • The aim was to be utilized as basic data in arranging efficient plan for removing halitosis by surveying correlation with halitosis components by each factor after measuring halitosis and analyzing components by subject of adults on halitosis. It targeted totally 160 people by 80 outpatients of 1 dental hospital, respectively, where is located in Daejeon and Chungnam, for 12 months from February 1, 2011 to January 30, 2012. As a result of analysis, in the halitosis measurement value of Oral chroma, it was shown to be 9.4% in case of being more than 112ppb in the measurement value of hydrogen sulfide, 20.6% in case of being more than 26ppb in the measurement value of methyl mercaptan, and 44.0% in case of being more than 8ppb in the measurement value of dimethyl sulfide, which was indicated to be the highest value among three components. Only the methyl mercaptan component and the dimethyl sulfide component, which were measured with oral chroma, stood at 0.578, thereby having been shown to have high positive correlation. Accordingly, a multilateral research is considered to be likely necessity as for diverse components of causing halitosis.

A Reusability Measurement of the Reused Component by Employing Rough and Fuzzy Sets (러프와 퍼지 집합을 이용한 재사용 컴포넌트의 재사용도 측정)

  • Kim, Hye-Gyeong;Choe, Wan-Gyu;Lee, Seong-Ju
    • The Transactions of the Korea Information Processing Society
    • /
    • v.6 no.9
    • /
    • pp.2365-2372
    • /
    • 1999
  • The reusability measurement model should satisfy the following conditions : 1) can insert and delete metrics and components easily, 2) can compare and evaluate components quantitatively on the basis of validation, 3) don't require certain preassumed knowledge, and 4) can compute significance of each measurement attribute objectively. Therefore, in this paper, we propose a new reusability measurement model that can satisfy the above requirements. Our model selects the appropriate measurement attributes and calculates the relative significance of them by using rough set. Then, in order to measure the reusability of component, it integrates the significance of attributes and the measured value of them by using fuzzy integral. Finally, we apply our model to the reusability measurement of the function-oriented components and validate our model through statistical technique.

  • PDF

Surface Color Measurement Uncertainties

  • Hwang, Jisoo;Jeong, Ki-Lyong
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.6
    • /
    • pp.649-657
    • /
    • 2015
  • We present a surface color measurement including quantities of surface color, methods, and uncertainty evaluation. Based on a relation between spectral reflectance and surface color, we study how an uncertainty of spectral reflectance propagates to surface color. In analyzing the uncertainty propagation, we divide the uncertainty into uncorrelated components, fully correlated components, and correlated components with spectrally varying correlations. As an experimental example, we perform spectro-reflectometric measurements for ceramic color plates. With measured spectral reflectance and its uncertainty evaluation, we determine surface color and analyze uncertainties of the ceramic color plates.

Estimation of the Ratio of Nonlinear Optical Tensor Components by Measuring Second Harmonic Generation and Parametric Down Conversion Outputs in a Single Periodically Poled LiNbO3 Crystal

  • Kumar, CH. S.S. Pavan;Kim, Jiung;Kim, Byoung Joo;Cha, Myoungsik
    • Current Optics and Photonics
    • /
    • v.2 no.6
    • /
    • pp.606-611
    • /
    • 2018
  • Measurement of the nonlinear optical coefficients is not an easy task since it requires complicated experimental setup and analysis. We suggest an easy way to estimate the relative nonlinear optical tensor components by direct measurement of the output powers of the second harmonic generation and spontaneous parametric down conversion experiments. The experiments were done in quasi-phase-matched type-0 as well as type-1 interactions at similar pump wavelengths in a 5% MgO-doped periodically poled $LiNbO_3$ crystal to obtain the ratio of the nonlinear optical tensor components $d_{33}/d_{31}$ in each experiment. The obtained ratios were then compared with the previously ascertained values [J. Opt. Soc. Am. B, 14, 2268-2294 (1997)].

Measurement-based Estimation of the Composite Load Model Parameters

  • Kim, Byoung-Ho;Kim, Hong-Rae
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.845-851
    • /
    • 2012
  • Power system loads have a significant impact on a system. Although it is difficult to precisely describe loads in a mathematical model, accurately modeling them is important for a system analysis. The traditional load modeling method is based on the load components of a bus. Recently, the load modeling method based on measurements from a system has been introduced and developed by researchers. The two major components of a load modeling problem are determining the mathematical model for the target system and estimating the parameters of the determined model. We use the composite load model, which has both static and dynamic load characteristics. The ZIP model and the induction motor model are used for the static and dynamic load models, respectively. In this work, we propose the measurement-based parameter estimation method for the composite load model. The test system and related measurements are obtained using transient security assessment tool(TSAT) simulation program and PSS/E. The parameter estimation is then verified using these measurements. Cases are tested and verified using the sample system and its related measurements.

Design and Implementation of the Reuse-Easiness Measurement System Using Fuzzy Logic

  • 이성주;최완규
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.6 no.4
    • /
    • pp.17-26
    • /
    • 1996
  • Software reuse is a method which increases the productivity of software, nevertheless software reuse is not employed well in real world. One of the important factors occured this proplem is insufficinet inforamtion in understanding and adapting the existing components. Understanding and adapting of components can be measured emplying user's experience and the attributes which the existing programs provide. Especially user's experience is very important attribute in understanding and adapting components, and it can't be measured by simple metrics. We propose in this paper, the reuse-easingess measurement system using fuzzy logic. This system can provide information regarding reusing components by reflecting user's experience from user's point of view, and can reduce the reuse effort signinificantly.

  • PDF

Experimental Measurement System for 3-6 GHz Microwave Breast Tomography

  • Son, Seong-Ho;Kim, Hyuk-Je;Lee, Kwang-Jae;Kim, Jang-Yeol;Lee, Joon-Moon;Jeon, Soon-Ik;Choi, Hyung-Do
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.4
    • /
    • pp.250-257
    • /
    • 2015
  • This paper presents an experimental measurement system for 3-6 GHz microwave tomography (MT) of the breast. The measurement system is constructed as a minimal test bed to verify key components such as the sensing antennas, radio frequency (RF) transceiver, sensing mechanism, and image reconstruction method for our advanced MT system detecting breast cancer at an early stage. The test bed has eight RF channels operating at 3 to 6 GHz for high spatial resolution and a two-axis scanning mechanism for three-dimensional measurement. The measurement results from the test bed are shown and discussed.

Measurement of Thermal Characteristics of Electric Unit for Sancheon High-Speed Railcar (고속열차 산천 전장품 발열특성 측정)

  • Park, Won-Hee;Yun, Su-hwan;Park, Choonsoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.6
    • /
    • pp.3672-3679
    • /
    • 2015
  • The heat generated by electrical components during train operation was estimated by measuring the wall temperature in a locomotive, as well as the temperature and speed of the air entering from the outside and then returning to the outside. The temperatures of the electrical components and wall surface in a high-speed train were measured using an infrared camera. The heat generated by the electrical components was exhausted to the outside through a duct installed on the ceiling of the high-speed train. Thus, the temperature and speed of this exhaust air were measured, as well as those of the air entering the locomotive from the outside. The temperatures at the surfaces of the electrical components and walls in the locomotive were also measured using an attachment-type temperature sensor. In addition, the measurement results were applied to analyze how the heat characteristics of the electrical components were affected by the train operation.