• Title/Summary/Keyword: 6 pulse

Search Result 2,148, Processing Time 0.028 seconds

AIx Change According to Pressing Angle and Pressing Force of the Radial Artery Pulse by Tonometry (토노메트리 방식 맥파 측정의 가압 각도와 가압력에 따른 AIx 변화)

  • Cho, JungHee;Jeon, Young Ju;Jun, Min-Ho;Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.4
    • /
    • pp.259-263
    • /
    • 2018
  • A radial artery pulse wave is measured while pressing an artery with constant force. However, pulse waveform measurements vary depending on pressing force and direction. Accurate pulse waveform measurements are important for analysis. Thus, it is necessary to define the measurement range of the permissible force and direction from which a correct pulse waveform is derived. In this study, pulse waves were generated by a pulse wave generator for accurate control. The pulse waves generated for different angles and pressing forces were analyzed. The augmentation index (AIx), which is the most commonly used index for evaluating vascular stiffness, was analyzed. The AIx was measured within ${\pm}6^{\circ}$ of the vessel direction and within ${\pm}8^{\circ}$ perpendicular to the vessel direction with a force that was 25% or more of the pressing force at which the maximum pressure wave was generated. We identified the applicable pressing force and angle range by analyzing the effect of pressing angle on the pulse wave. The AIx analysis performed using the pulse wave measurement device is reliable and reproducible.

Development of a Sleep-driving Accident Prevention System based on pulse

  • Bae, Seung-Woo;Seo, Jung-Hwa
    • Korean Journal of Artificial Intelligence
    • /
    • v.6 no.1
    • /
    • pp.11-15
    • /
    • 2018
  • The purpose of this study is to develop a pulsatile drowsiness detection system that can compensate the limitations of existing camera - based or breathing pressure sensor based Drowsiness driving prevention systems. A heart rate sensor mounted on the driver's finger and an alarm system that sounds when drowsiness is detected. The heart rate sensor was used to measure pulse changes in the wrist, and an alarm system based on the Arduino, which works in conjunction with the laptop, generates an audible alarm in the event of drowsiness. In this paper, we assume that the pulse rate of the drowsy state is 60 ~ 65 times / minute, which is the middle between the awake state and the sleep state. As a result of the experiment, the alarm sounded when the driver's pulse rate was in the drowsy pulse rate range. Based on these experiments, the drowsiness detection system was able to detect the drowsiness of the driver successfully in real time. A more effective drowsiness prevention system can be developed in the future by incorporating the results of the present study on a pulse-based drowsiness prevention system in an existing drowsiness prevention system.

Finite Element Analysis on the Improvement of Residual Deformation of the Part After Pulse Laser Welding of Circular Cover (원형 커버의 펄스 레이저 용접 후 부품 잔류변형 개선에 관한 유한요소해석)

  • Kim, Kwan-Woo;Cho, Hae-Yong
    • Journal of Welding and Joining
    • /
    • v.33 no.6
    • /
    • pp.60-66
    • /
    • 2015
  • Molten zone shape of pulse laser welding is affected by welding conditions such as beam power, beam speed, irradiation time, pulse frequency, etc. and is divided into conduction type and keyhole type. It is necessary to design heat source model for irradiation of laser beam in the pulse laser welding. Shape variables and the maximum energy density value of the heat source model are different depending on the molten zone shape. In this paper, pulse laser welding simulation for joining of cylindrical part and circular cover was carried out. The heat source model for pulse laser beam with circular path was applied to the heat input boundary condition, radiative and conductive heat transfer were considered for the thermal boundary condition. For each phase, thermal and mechanical properties according to temperature were also applied to analysis. Analytical results were in good agreement with the molten zone size of specimen under the same welding conditions. So, the reliability of the welding simulation was verified. Finally, the improvements for reducing residual deformation after cover welding could be reviewed analytically.

Effects of Low Incident Energy Levels of Infrared Laser Irradiation on the Proliferation of Candida Albicans Part I : A Long Term Study according to Pulse Type

  • Sam-Kun Kim;Phil-Yeon Lee;Ki-Suk Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.9-15
    • /
    • 1994
  • This experiment was performed to confirm the hypothesis that LLLT had biostimulation effect for all kinds of cells and there would be differences in the growth of cells among different types of pulsed laser. 360 samples were used in this study. The samples were randomly divided in 6 groups according to the pulse type : quasi continuous type (CW), pulse 1(P1), pulse 7(P7), pulse 9(P9), pulse 15(P15) and shame-irradiated control(Co) groups. Energy fluences of all experimental groups, P1, P7, P9, P15 and CW were 2.12, 2.12, 6.37, 57.32 and 31.85 mj/cm2 respectively. All samples were irradiated for every 1 minute at 0, 12, 24, 36, 48 and 60 hours. Ten samples of each group were sacrificed at 0 and every 12 hours and then the optical density of all samples was measured with the spectrophotometer. As a result, some types of pulses showed significant differences among groups. The increase of cells were markedly stimulated with laser irradiation in P7 and P9 groups, while inhibited in CW, P1, and P15 groups compared with control group. It is therefore, suggested that specific laser pulse should be recommanded to have the biostimulation effects on the specific tissue or cells, although the biostimulation effect is does dependant.

  • PDF

Study on the frequency of self-excited pulse jet

  • Wang, Jian;Li, Jiangyun;Guan, Kai;Ma, Tianyou
    • International Journal of Fluid Machinery and Systems
    • /
    • v.6 no.4
    • /
    • pp.206-212
    • /
    • 2013
  • Self-excited pulse jet is a specific nozzle with a closed chamber which can change a continuous jet into a pulse one. Energy of the pulse jet can be output not only unevenly but also with multifrequency. With the peak pressure of pulse jet, the hitting power would be 2~2.5 times higher than that of continuous jet. In order to reveal the correlation between the self-excited pulse frequency and nozzle diameter ratio, nozzle spacing and operating pressure, the model of 3D unsteady cavitation model has been used. We found that with the same nozzle structure parameters and the different operating pressure, the self-excited frequency and the width of peak crest are different, but the wave profiles are similar. With FFT, we also found that the less bandwidth of amplitude in low frequency range will lead to the wider wave crest of outlet velocity in its time domain, and the larger force of the strike will be gained. By studying the St of self-excite nozzle, not only the frequency of a certain nozzle can be predicted, but also a nozzle structure with a certain frequency can be designed.

A Buck-Boost Converter-Based Bipolar Pulse Generator

  • Elserougi, Ahmed A.;Massoud, Ahmed M.;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1422-1432
    • /
    • 2017
  • This paper presents a buck-boost converter-based bipolar pulse generator, which is able to generate bipolar exponential pulses across a resistive load. The concept of the proposed approach depends on operating the involved buck-boost converters in discontinuous current conduction mode with high-voltage gain and enhanced efficiency. A full design of the pulse generator and its passive components is presented to ensure generating the pulses with the desired specifications (rise time, pulse width, and pulse magnitude) for a given load resistance and input dc voltage. In case of moderate pulsed output voltages (i.e. few of kV), one module of the presented bipolar generator can be employed. While in case of high-voltage pulsed output, multi-module version can be employed, where each module is fed from an isolated dc source and their outputs are connected in series. Simulation models for the proposed approach are built to elucidate their performance in case of one-module as well as multi-module based generator. Finally, a scaled-down prototype for one-module of buck-boost converter-based bipolar pulse generator is implemented to validate the proposed concept.

Influence of Sustain Pulse-width on Electrical Characteristics and Luminous Efficiency in Surface Discharge of AC-PDP

  • Jeong, Yong-Whan;Jeoung, Jin-Man;Choi, Eun-Ha
    • Transactions on Electrical and Electronic Materials
    • /
    • v.6 no.6
    • /
    • pp.276-279
    • /
    • 2005
  • Influences of sustain pulse-width on electrical characteristics and luminous efficiency are experimentally investigated for surface discharge of AC-PDP. A square pulse with variable duty ratio and fixed rising time of 300 ns has been used in the experiment. It is found that the memory coefficient is significantly increased at the critical pulse-width. And the wall charges and wall voltages as well as capacitances are experimentally measured by Q- V analysis method along with the voltage margin relation, in terms of the sustain pulse-width in the range of $1{\mu}s$ to $5{\mu}s$ under driving frequency of 10 kHz to 180 kHz. And the luminous efficiency is also experimentally investigated in above range of sustain pulse-width with driving frequency of 10 kHz to 180 kHz. It is noted that the luminous efficiency for 10 kHz and 180 kHz are 1.29 1m/W and 0.68 1m/W respectively, since the power consumption for 10 kHz is much less than that for 180 kHz. It has been concluded that the optimal sustain pulse-width is in the range of $2.5 {\~}4.5{\mu}s$ under driving frequency range of 10 kHz and 60 kHz, and in the range of $1.5 {\~} 2.5{\mu}s$ under driving frequency range of 120 kHz and 180 kHz based on observation of memory coefficient, and wall voltage as well as luminous efficiency.

A Study on software Development for Control Application of Microprocessors (마이크로프로세써의 제어 응용을 위한 소프트웨어 개발에 관한 연구)

  • 이태원
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.15 no.6
    • /
    • pp.66-78
    • /
    • 1978
  • An assembly package program is developed for a computerize4 operation of a drilling machine system utilizing a microprocessor. Different drilling instruction requires merely the input of different sets of input data. To make pulse motors to follow their input pulse trains with fidelity, an optimum start-stop rate matrix is proposed, whose elements are determined according to the pulse motor torque and the load inertia of the mechanical system composed of a workpiece and a worktable.

  • PDF

Mating Call Structure and Variation of the Frog Rana nigromaculata (참개구리(Rana nigromaculata)의 짝짓기 소리의 구조와 변이)

  • 박시룡;양서영
    • The Korean Journal of Ecology
    • /
    • v.20 no.6
    • /
    • pp.423-438
    • /
    • 1997
  • The structure and variation of the mating call in Rana nigromaculata was studied in a population at Da-rak, Chong-won, Chung-buk (36$\circ$ 37' latitude, 127$\circ$ 21' longitude) in Korea. The mating call consists of 3 to 8 pulse groups divided by clear silent intervals. Each pulse group is also composed of fine pulses. Temperature and body size affect the temporal and spectral characteristics of the mating call. Pulse, pulse group repetition rate and dominant frequency rise with increasing temperature, whereas pulse grouprepetition rate and dominant frequency decrease with increasing body size. A playback experiment was designed to establish the effect of a potential intruder on male calling. During the stimulus periods, resident males markedly decreased the pulse repetition rate, and icreased the rate of pulse groups, dominant frequency, and the number of call groups. This results indicate that this species responds in a graded fashion when interacting with other individuals.

  • PDF

Precise Measurement Method of Radial Artery Pulse Waveform using Robotic Applanation Tonometry Sensor (로보틱 토노메트리 센서를 이용한 요골 동맥 파형 정밀 측정 방법)

  • Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • In this paper, a novel measurement method of radial artery pulse waveform using robotic applanation tonometry (RAT) was present to reduce the errors by the pressing direction of the vessel. The RAT consisted of an array of pressure sensors and 2-axis tilt sensor, which was attached to the universal joint with a linear spring and five-DOF robotic manipulator with a one-axis force sensor. Using the RAT mechanism, the pulse sensor could be manipulated to perpendicularly pressurize the radial artery. A pilot experimental result showed that the proposed mechanism could find the optimal pressurization angles of the pulse sensor within ${\pm}3^{\circ}$standard deviations. Coefficient values of variation of maximum pulse peaks extracted from the pulse waveforms were 4.692, 6.994, and 11.039 % for three channels with the highest magnitudes. It is expected that the proposed method can be helpful to develop more precise tonometry system measuring the pulse waveform on the radial artery.