• Title/Summary/Keyword: 6 MV 광자선

Search Result 143, Processing Time 0.021 seconds

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Is Radiotherapy Necessary for Stage 1 Testicular Seminoma? (제1병기 성인 고환 정상피종에 대한 임상적 고찰 및 치료결과 분석)

  • Lee, Jung-Ae;Park, Won;Lim, Do-Hoon;Ahn, Yong-Chan;Huh, Seung-Jae;Yu, Jeong-Il;Choi, Han-Yong;Lee, Hyun-Moo;Cho, Eun-Yoon
    • Radiation Oncology Journal
    • /
    • v.27 no.2
    • /
    • pp.49-54
    • /
    • 2009
  • Purpose: To report on the clinical outcome of patients with stage I testicular seminoma by postoperative radiotherapy (PORT) or surveillance after radical inguinal orchiectomy. Materials and Methods: This study is a retrospective review of 32 stage I pure seminoma patients treated between 1996 and 2005 at the Samsung Medical Center. Twenty two of the patients were treated by PORT, which was directed at the paraaortic lymphatics with a median dose of 25.2 Gy in 14 fractions for 3 weeks. The 10 remaining patients were managed by surveillance. The median follow-up period was 96 months with a range of 24 to 155 months. Results: Clinically, most patients presented with a testicular mass or discomfort. Two of the patients had a history of undescended testes. Pathologically, 23 of the patients had intratubular germ cell neoplasia with seminoma. Both recurrence-free survival (RFS) and overall survival (OS) rates of patients treated by PORT were 100%. In the control group, 1 of the 10 patients suffered a para-aortic lymph node relapse. The RFS and OS rates of the surveillance group were 88.9% and 100%, respectively. Conclusion: No difference in survival was observed between the two groups. Moreover, symptom recurrence was only observed in 1 patient in the control group. The use of PORT may reduce the risk of relapse. With the availability of effective diagnostic and salvage modalities, surveillance monitoring may be considered for patients in good compliance.

Bladder Preserving Treatment in Patients with Muscle Invasive Bladder Cancer (근침윤성 방광암 환자의 방광 보존적 치료 결과)

  • Yu, Jeong-Il;Oh, Dong-Ryol;Huh, Seung-Jae;Choi, Han-Yong;Lee, Hyon-Moo;Jeon, Seong-Soo;Yim, Ho-Young;Kim, Won-Suk;Lim, Do-Hoon;Ahn, Yong-Chan;Park, Won
    • Radiation Oncology Journal
    • /
    • v.25 no.2
    • /
    • pp.70-78
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: This study analyzed the tumor response, overall survival, progression free survival and related prognostic factors in patients with muscle invasive bladder cancer subjected to bladder preserving treatment. $\underline{Materials\;and\;Methods}$: Between August 1995 and June 2004, 37 patients with muscle invasive (transitional cell carcinoma, clinically stage T2-4) bladder cancer were enrolled for the treatment protocol of bladder preservation. There were 33 males and 4 females, and the median age was 67 years (range $38{\sim}86\;years$). Transurethral resection of the bladder (TURB) was performed in 17 patients who underwent complete resection. The median radiation dose administered was 64.8 Gy (range $55.8{\sim}67\;Gy$). The survival rate was calculated by the Kaplan-Meier method. $\underline{Results}$: An evaluation of the response rate was determined by abdomen-pelvic CT and cystoscopy at three months after radiotherapy. A complete response was seen in 17 patients (46%). The survival rate at three years was 54.7%, with 54 months of median survival (range $3{\sim}91$ months). During the study, 17 patients died and 13 patients had died from bladder cancer. The progression free survival rate at three years was 37.2%. There were 24 patients (64.9%) who had disease recurrence: 16 patients (43.2%) had local recurrence, 6 patients (16.2%) had a distant recurrence, and 2 patients (5.4%) had both a local and distant recurrence. The survival rate (p=0.0009) and progression free survival rates (p=0.001) were statistically significant when compared to the response rate after radiotherapy. $\underline{Conclusion}$: The availability of complete TURB and appropriate chemoradiotherapy were important predictors for bladder preservation and survival.