• Title/Summary/Keyword: 6가크롬 환원

Search Result 10, Processing Time 0.025 seconds

Studies on Atomic Absorption Spectrophotometric Analysis of Hexavalent Chromium in Waste Water by Solvent Extraction (용매 추출법에 의한 폐수중 6가크롬의 원자흡수 분광분석에 관한 연구)

  • Eung-Pyo Kim;Young-Sang Kim
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.5
    • /
    • pp.423-432
    • /
    • 1986
  • Atomic absorption spectrophotometric (AAS) determination of hexavalent chromium [Cr(VI)] in a waste water was studied. Cr(VI) was extracted with p-xylene from the wastewater, in the way of ion pair formation with anion exchanger aliquat-336(tri-caprylmethyl ammonium chloride). 100ml waste water, after organic materials were extracted out with toluene, was acidified with conc. HCl adjusting the medium to pH 0.5 and 20ml of p-xylene containing 0.01M aliguat-336 was used to extract Cr(VI) from the acidified solution. The absorbance of chromium was measured with air-acetylene flame at 357.9nm. Standard addition method was used in the determining concentration of Cr(VI) extracted. No interference has been found in the extraction of Cr(VI) by the Al(III), Fe(III) and Cr(III) ion presented. However, Fe(II) decreased the absorbance of Cr(VI), due to the fact Fe(II) reduces Cr(VI) to Cr(III). The contained organic material was removed prior to extracting process, since it may reduced the absorbance of Cr(VI). The recovery of added Cr(VI) was over 96%, which seems to be promising and the relative standard deviation was 3.95%

  • PDF

Adsorption Characteristics of Cr(VI) on the Oak Sawdust (참나무톱밥에 대한 6가크롬의 흡착특성)

  • Chung, Yongsoon;Lee, Kangwoo;Hwang, Jongyeon
    • Analytical Science and Technology
    • /
    • v.11 no.4
    • /
    • pp.254-259
    • /
    • 1998
  • The adsorption and reduction characteristics of chromium(VI) by oak sawdust were studied. The optimum adsorption condition is obtained from the measurement of the distribution coefficient($K_d$) and adsorption capacity of Cr(VI) on the sawdust by changing pH of the solution. As a result, it was found that pH 2.0 was optimum because $K_d$ of Cr(VI) was maximum and reducing quantity was minimum. By the use of these characteristics of the oak sawdust, the removing of Cr(VI) in industrial waste water was examined.

  • PDF

Reduction Characteristics of Hexavalent Chromium in Cement/Fe(II) Systems

  • 강희석;서진권;황인성;박주양
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.233-236
    • /
    • 2002
  • 다양한 산업활동에 의하여 발생하는 6가 크롬 (Cr(Ⅵ))은 대표적인 토양 및 지하수 오염물질이다. Cr(Ⅵ)은 3가크롬(Cr(III))로의 환원에 의한 침전반응으로 이동성이 저하된다고 알려져 있다. 본 연구에서는 기존의 고형화/안정화 공정에 환원.분해 반응을 추가한 2가철 기반 분해성 고형화/안정화(Degradative Solidification/Stabilization)공정에 의한 Cr(Ⅵ) 처리 특성을 고찰하였다. 회분식 실험결과 cemen/Fe(II) system내에 Cr(Ⅵ)은 환원반응 뿐만 아니라 cement에 의한 침전에 의해서도 제거됨이 밝혀졌다. Cr(Ⅵ)의 제거속도는 Fe(II)의 반응당량에 비례하는 것으로 보여진 반면, cement/solution ratio에 따른 Cr(Ⅵ) 제거동역학의 차이는 그다지 크지 않았다

  • PDF

Fixation characteristics of CCA and CCFZ in Japanese Red Pine, Japanese Larch, and Ezo Spruce Sapwood (소나무, 낙엽송, 북양가문비나무 변재부에서 CCA와 CCFZ의 정착특성)

  • Kim, Gyu-Hyeok;Kim, Hyung-Jun;Kim, Jae-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.52-59
    • /
    • 2001
  • The fixation characteristics of CCA and CCFZ in Japanese red pine, Japanese larch, and ezo spruce sapwood were compared at various temperatures and fixation conditions (drying and nondrying fixation). Fixation was monitored by the rates of reduction of hexavalent chromium to trivalent one, and optimal fixation time was estimated based on the results. The rate of fixation was highly temperature dependent, and the fixation rate of treated wood conditioned under nondrying conditions was much more faster than that under drying conditions, especially when the moisture content of treated wood was below fiber saturation point. Preservative types affected fixation; CCA-Type B had the highest fixation rate, followed by CCA-Type C and then CCFZ. The differences in fixation rates of preservative components were also observed among wood species; Japanese red pine fixed the fastest, followed by Japanese larch and then ezo spruce. Time required to complete fixation according to the fixation temperature could be predicted successfully using the regression equations between the temperatures and fixation time, regardless of conditioning methods, preservative types, and wood species.

  • PDF

Effect of TiO2 Nanotube Length on Photocatalytic Activity with Different Light Intensities: Cr(VI) Reduction and Hydrogen Production (광량 및 TiO2 나노튜브 길이별 광활성 연구: Cr(VI)환원 및 수소제조)

  • Joo, Hyun-Ku;Shim, Eun-Jung;Lee, Jae-Min;Yoon, Jae-Kyung
    • Journal of Hydrogen and New Energy
    • /
    • v.22 no.4
    • /
    • pp.432-442
    • /
    • 2011
  • Anodized tubular $TiO_2$ electrodes (ATTEs) with three noticeably different lengths are prepared to determine their optimum length for the photo-driven activity in the reaction of Cr(VI) reduction and hydrogen evolution. The ATTEs with ethylene glycol have longer $TiO_2$ tubes (7-15.6 ${\mu}m$) than those with hydrfluoric acid (0.6-0.8 ${\mu}m$). These samples, which differ only in the length of the tubes, with a wall thickness of ca. 20 nm, consist mainly of an anatase crystalline phase after heat treatment at $650^{\circ}C$, since the anatase crystallites at the tube walls do not undergo transformation into rutile phase, due to the constraints imposed by the wall thickness. Among them, the medium size (ca. 8 ${\mu}m$) tubes provide the optimum conditions, irrespective of the light intensity, which is explained in terms of the correlation between the amount of photons and the adsorbed electron acceptors and their location. Photocatalytic Cr(VI) reduction leads to ca. 60% reduction of Cr(VI) even under 1 sun irradiation with the medium-sized anodized $TiO_2$ tubes, but only ca. 20% with the short- and long-sized tubes. For hydrogen evolution, tubes longer than 8 ${\mu}m$ do not exhibit better performance with any light intensity.

Anodization of $TiO_2$ with Seawater Electrolyte; Evaluation of Hydrogen Production in PEG and Photocatalytic Cr(VI) Reduction (해수전해질을 이용한 양극산화 $TiO_2$ 제조; 광전기화학적 수소제조 및 Cr(VI) 환원처리 연구)

  • Shim, Eun-Jung;Park, Min-Sung;Her, A-Young;Joo, Hyun-Ku;Yoon, Jae-Kyung
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.5
    • /
    • pp.404-409
    • /
    • 2009
  • The present works were performed that titanium foil was anodized in various dilution ratios of seawater and distilled water with 10V external voltage applied, then annealed at $450^{\circ}C$ to obtain $TiO_2$ on the Ti substrate. The prepared samples were characterized by instruments (XRD, SEM, and photocurrent) and used to investigate rate of hydrogen production in photoelectrochemical cell as well as Cr(VI) reduction. As the results of experiments, the anodized $TiO_2$ in seawater electrolytes, which are ranged from 15 to 50 times dilution of seawater, was showed a relatively higher hydrogen production (ca. 97~110 umol/hr-$cm^2$) and Cr(VI) reduction (ca. 95% reduction).

Cr(VI) Removal from Artificial Groundwater by Granular Activated Carbon and Regeneration of the Spent Carbon (입상활성탄을 이용한 인공 조제 지하수내의 Cr(VI) 제거와 그 활성탄의 재생)

  • Ihnsup Han
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.11-31
    • /
    • 1999
  • Removal of hexavalent chromium from artificial groundwater (AGW) by granular activated carbon (GAC) was investigated in batch and continuous-flow column studies. Experimental parameters that were examined included solution pH, presence of dissolved oxygen (DO), and GAC pretreatment with Fe(II). As the solution pH increased from 4 to 7.5, the amount of Cr(VI) removed by both GACs decreased significantly. Exclusion of DO from the experimental systems resulted in greater removal of Cr(VI) from solution, possibly as a result of reduction to Cr(III). However, pretreatment of the GAC with a reductant (Fe(II)) did not improve Cr(VI) removal. Equilibration With 0.01 M $K_2$$HPO_4$[to extract adsorbed Cr(VI)] followed by a wash with 0.02 N $K_2$$HPO_4$[to remove precipitated/sorbed Cr(III)] proved to be a viable approach for the regeneration of carbons whose Cr(VI) removal capacities had been exhausted. The performance of the regenerated carbons exceeded that of the virgin carbons, primarily because of the favorable adsorption of Cr(VI) at lower pH values and the reduction of Cr(VI) to Cr(III), The presence of Cr(III) in acid wash solutions provides direct evidence that Cr(VI) is reduced to Cr(III) in GAC systems under relatively acidic conditions. GAC performance over five complete cycles was consistently high, which suggests that such a system will be able to function over many operation cycles without deleterious effects.

  • PDF