• Title/Summary/Keyword: 5VOC

Search Result 346, Processing Time 0.027 seconds

Paint booth volatile organic compounds emissions in an urban auto-repair center

  • Cho, Minkyu;Kim, Ki-Hyun;Szulejko, Jan E.;Dutta, Tanushree;Jo, Sang-Hee;Lee, Min-Hee;Lee, Sang-hun
    • Analytical Science and Technology
    • /
    • v.30 no.6
    • /
    • pp.329-337
    • /
    • 2017
  • A major concern regarding most auto-repair shops in residential areas is the emission of odorous volatile organic compounds (VOCs) into the local atmosphere, especially during painting operations. VOCs contribute to poor local air quality and are responsible for the perceived odor and discomfort experienced by local residents. Sixteen major VOCs (6 aromatic hydrocarbons and 10 aliphatic carbonyl compounds) were selected as potential target compounds. The site was an auto-repair shop located in a central region of Seoul, South Korea, where the air quality of the site has been a subject of residents' complaints. The sampling points were as follows: 1) in the painting booth with new (NB) or old (OB) removal system, (2) in the exhaust duct after new (ND) or old (OD) odor removal filter, and (3) 2 m below the discharge vent (4 m above the ground) (outdoor air, OA). Each sample was coded: (1) before painting (BP), (2) during painting (DP), and (3) after painting (AP). The toluene level in the duct with the new removal filter during painting (ND-DP) was 1.5 ppm (v/v), while it was 3.8 ppm (v/v) in the right duct with an old removal filter during painting (OD-DP). Accordingly, the effect of filter replacement was reflected by differences in VOC levels. Therefore, accurate monitoring of odorous VOCs is an important step to reduce odor nuisance from local sources.

Analysis of Annual Emission Trends of Air Pollutants by Region (권역별 대기오염물질의 연도별 배출 특성 분석)

  • Lim, Jun Hyun;Kwak, Kyeong Kyu;Kim, Jeong;Jang, Young Kee
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.34 no.1
    • /
    • pp.76-86
    • /
    • 2018
  • Using the CAPSS emissions data, we analysed changes and reasons in the annual air pollutant emission trends from 1999 to 2014. The CO emissions in the metropolitan area decreased steadily since 2001, when the latest model year of automobiles and high efficiency fuel were applied. However, other regions have not changed significantly in annual emissions. $NO_x$ emissions continued to increase since 2003, and unchanged after the decline in 2007. $SO_x$ emissions are steadily declining due to the supply of low sulfur oil. The $PM_{10}$ and $PM_{2.5}$ emissions were repeatedly affected by the influence of motor vehicles activities in the metropolitan area. In Gangwon and Chungcheong Provinces, emissions are increasing according to the use of coal in the manufacturing sector. And VOC and $NH_3$ emissions are increasing steadily every year. The major CO emission sources was automobiles in the metropolitan area. However, agricultural residue burning was the biggest CO sources in the Chungchong, Honam and Yeongnam Provinces. The major sources of $NO_x$ emissions differ from region to region. In the Metropolitan area, Honam and Yeongnam region, the truck was the largest emitter of $NO_x$. However, the cement kiln was the largest producer of $NO_x$ in Gangwon region, and the power plant is the largest emitter in Chungcheong Provinces.

Power-Dependent Characteristics of $n^+$-p and $p^+$-n GaAs Solar Cells

  • Kim, Seong-Jun;Kim, Yeong-Ho;No, Sam-Gyu;Kim, Jun-O;Lee, Sang-Jun;Kim, Jong-Su;Lee, Gyu-Seok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.236-236
    • /
    • 2010
  • 단일접합 $n^+-p/p^+$ (p-emitter) 및 $p^+-n/n^+$ (n-emitter) GaAs 태양전지 (Solar Cell)를 각각 제작하여, 그 소자특성을 비교 분석하였다. AM 1.5 (1 sun, $100\;mW/cm^2$) 표준광을 조사할 경우, p-emitter/n-emitter 소자의 개방회로전압 (Voc), 단락회로전류 (Jsc), 충전율 (FF), 효율 (Eff)은 각각 0.910/0.917 V, $15.9/16.1\;mA/cm^2$, 78.7/78.9, 11.4/12.1%로서, n-emitter 소자가 다소 크지만 거의 비슷한 값을 가지고 있었다. 태양전지의 집광 특성을 분석하기 위하여 조사광의 출력에 따른 태양전지의 소자 특성을 측정하였다. 조사광 강도가 높아짐에 따라 p-emitter 소자의 특성은 점진적으로 증가하는 반면, n-emitter는 1.3 sun에서 약 1.4 배의 최대 효율 (17%)을 나타내고 조사광이 더 증가함에 따라 급격히 감소하는 특성을 보여 주었다. (그림 참고) 본 연구에서 사용한 2종류 소자의 층구조는 서로 반대되는 대칭구조로서, 모두 가까이에 위치하고 있는 표면전극 (surface finger) 방향으로 소수전하 (minority carrier)가 이동하고 다수전하 (majority carrier)는 기판 (두께 $350\;{\mu}m$)을 통한 먼 거리의 후면전극 (back electrode)으로 표류 (drift)되도록 설계되어 있다. 이때, n-emitter에서는 이동도 (mobility)와 확산길이 (diffusion length)가 높은 전자가 후면전극으로 이동하기 때문에 적정밀도의 전자-정공 쌍 (EHP)이 여기될 경우에는 Jsc와 Eff가 극대화되지만, 조사광 강도 또는 EHP가 더 높아질 경우에는 직렬저항의 증가와 함께 전류-전압 (I-V)의 이상인자 (ideality factor)가 커짐으로서 FF와 효율이 급격히 감소한 결과로 분석된다. 현재 전산모사를 통한 자세한 분석을 진행하고 있으며, 본 결과는 효율 극대화를 위한 최적 층구조 및 도핑 밀도 설계에 활용할 수 있을 것으로 판단된다.

  • PDF

Performance characteristics of simultaneous removal equipment for paint particulate matter and VOCs generated from a spraying paint booth (입자상물질과 VOCs 동시제거 실증장치에서 자동차 페인트 부스 발생 paint aerosol과 VOCs의 동시제거 성능 특성)

  • Lee, Jae-Rang;Hasolli, Naim;Jeon, Seong-Min;Lee, Kang-San;Kim, Kwang-Deuk;Park, Young-Ok
    • Particle and aerosol research
    • /
    • v.12 no.4
    • /
    • pp.161-168
    • /
    • 2016
  • The purpose of this study is to determine the performance characteristics of the paint particulate and volatile organic compounds(VOCs) simultaneous removal from the spraying paint booth in the laboratory and real site by sticky paint particulate and VOCs simultaneous removal demonstration unit. The sticky paint particulate and VOCs simultaneous removal unit is composed of the horizontal type pleated filter modules and the zig-zag type granular activated carbon packing modules. The test conditions at the laboratory are $50.15g/m^3$ of average paint aerosol concentration and 300 ppm of VOCs concentration which were same as the working conditions of spraying paint booth in the real site. But, the demonstration conditions at the real site are varied according to the working condition of spraying paint booth for the kind of passenger car bodies. The test results at the laboratory obtained that 99% of total particulate collection efficiency at 0.62 m/min of filtration velocity and 84% at 1.77 m/min of filtration velocity. The VOCs removal efficiencies are 97% at $3500hr^{-1}$ of gas hour space velocity and 59% at $10,000hr^{-1}$ of gas hour space velocity. In the real site test, the average removal efficiency of PM10 was measured to be 99.65%, the average removal efficiency of PM2.5 was 99.38%, the average removal efficiency of PM1 was 98.52%, and the average removal efficiency of VOCs was 89%.

An Endophytic Nodulisporium sp. from Central America Producing Volatile Organic Compounds with Both Biological and Fuel Potential

  • Syed, Riyaz-Ul-Hassan;Strobel, Gary;Geary, Brad;Sears, Joe
    • Journal of Microbiology and Biotechnology
    • /
    • v.23 no.1
    • /
    • pp.29-35
    • /
    • 2013
  • A Nodulisporium sp. (Hypoxylon sp.) has been isolated as an endophyte of Thelypteris angustifolia (Broadleaf Leaf Maiden Fern) in a rainforest region of Central America. It has been identified both on the basis of its morphological characteristics and by scanning electron microscopy as well as ITS sequence analysis. The endophyte produces volatile organic compounds (VOCs) that have both fuel (mycodiesel) and use for biological control of plant disease. When grown on potato dextrose agar, the organism uniquely produces a series of ketones, including acetone; 2-pentanone; 3-hexanone, 4-methyl; 3-hexanone, 2,4-dimethyl; 2-hexanone, 4-methyl, and 5-hepten, 2-one and these account for about 25% of the total VOCs. The most abundant identified VOC was 1,8 cineole, which is commonly detected in this group of organisms. Other prominent VOCs produced by this endophyte include 1-butanol, 2-methyl, and phenylethanol alcohol. Moreover, of interest was the presence of cyclohexane, propyl, which is a common ingredient of diesel fuel. Furthermore, the VOCs of this isolate of Nodulisporium sp. were selectively active against a number of plant pathogens, and upon a 24 h exposure caused death to Phytophthora palmivora, Rhizoctonia solani, and Sclerotinia sclerotiorum and 100% inhibition to Phytophthora cinnamomi with only slight to no inhibition of the other pathogens that were tested. From this work, it is becoming increasingly apparent that each isolate of this endophytic Nodulisporium spp., including the Daldina sp. and Hypoxylon spp. teleomorphs, seems to produce its own unique set of VOCs.

Photoelectric Conversion Efficiency of DSSC According to Plasma Surface Treatment of Conductive Substrate (전도성 기판의 플라즈마 처리에 따른 염료감응형 태양전지 광전변환 효율 특성 변화)

  • Ki, Hyun-Chul;Kim, Seon-Hoon;Kim, Doo-Gun;Kim, Tae-Un;Hong, Kyung-Jin;So, Soon-Yeol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.11
    • /
    • pp.902-905
    • /
    • 2012
  • This study is explore the photoelectric conversion change of dye-sensitized solar cells with surface treatment of the conductive substrate. gases of FTO surface treatment were $N_2$, and $O_2$. Treatment conditions of surface were gas flux from 25 sccm to 50 sccm and RF power were from 25 W to 50 W. Treatment time and pressure were fixed 5 min and 100 mtoor. The best sheet resistance and surface roughness were obtained by $O_2$ 50 sccm and 50 W and that result were 7.643 ${\Omega}/cm^2$ and 17.113 nm, respectively. The best efficiency result was obtained by $O_2$ 50 sccm and 50 W and that result of Voc, Jsc, FF and efficiency were 7.03 V, 14.88 $mA/cm^2$, 63.75% and 6.67%, respectively.

Development of Volatile Organic Compound Pretreatment Device for Removing Exhaust Gas from Display Manufacturing Process (Display 제조공정 배출가스 처리를 위한 휘발성 유기화합물 전처리 장치 개발)

  • Moon, Gi-Hak;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • v.30 no.5
    • /
    • pp.523-529
    • /
    • 2019
  • In this study, we investigated the pretreatment technologies of volatile organic compounds (VOCs) which is a problem as the semiconductor and display industry develops recently. The conventional concentrator used in the direct combustion system, is easily contaminated by the exhaust gas in the manufacturing process of the display, resulting in the low treatment efficiency of generated VOCs. Physical/Chemical analyses of the exhaust gas showed high boiling point and viscosity in addition to a large amount of molecular weight alcohols and oil components. In this study, we tried to treat degrading materials by using the heat exchanger in a pretreatment facility and some materials degrading the concentrator were condensed more than 90%. In addition, it was also confirmed that an auxiliary device of the grease filter could remove the redispersion polymer oil from the heat exchanger.

The Relationship between Indoor Air Pollutants and Pulmonary Function in Asthmatic Children with Mold Sensitization (곰팡이에 감작된 소아 천식 환자 가정내 환경유해물질 농도와 폐기능의 상관관계)

  • Yoon, Wonsuck;Lim, Jaehoon;Park, Sang Hyun;Lee, Mingyu;Yoo, Young
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.685-693
    • /
    • 2020
  • Objectives: Recent data indicate that sensitization to mold contributes to the severity and persistence of asthma. The aim of this study was to investigate relationships between indoor mold concentrations and pulmonary function parameters in asthmatic children with mold sensitization. Methods: Asthmatic subjects who had a positive result in skin-prick testing to more than one mold allergen, such as Alternaria, Aspergillus, or Penicillium, were enrolled. Their pulmonary function and methacholine challenge test results were collected. Measurements of blood eosinophil, serum IgE, and fractional exhaled nitric oxide (FeNO) were taken. Indoor levels of VOC, CO2, PM10 and PM2.5 in each subject's house were measured. We counted mold and bacteria colonies from the subjects' house air samples. Results: The mean levels of FEV1, FVC, FEV1/FVC, and FEF25-75 were 82.8±19.7, 87.3±17.9, 85.8±8.3, and 82.3±28.9%, respectively. The mean FeNO level was 19.8±11.2 ppb and the geometric mean (range of one SD) of methacholine PC20 was 3.99 mg/mL (0.67-23.74 mg/mL). The average indoor air pollutant levels were below the recommended levels set by the Ministry of Environment for multiplex buildings. Indoor mold levels showed a significant inverse correlation with methacholine PC20, but not with the baseline pulmonary function parameters. Conclusion: Indoor mold concentrations are a risk factor for increased bronchial hyperresponsiveness among asthmatic children with mold sensitization. Targeted environmental intervention should be considered for selected asthmatic children with mold sensitization for avoiding severe airway hyperresponsiveness.

Mainstream smoke level of harmful substances in korean domestic cigarette brands

  • Choi, Hyun Doc;Song, Seok Ho;Cho, Hoonsik;Kim, Hyung Kyung;Lee, Jin-Hee;Yoon, Soon-Byung;Heo, Seok;Park, Hyoung-Joon
    • Analytical Science and Technology
    • /
    • v.31 no.1
    • /
    • pp.14-22
    • /
    • 2018
  • After signing the WHO FCTC in 2003, South Korea ratified the FCTC in 2005. This study was conducted to provide data on toxic constituents that can be used as useful information for the level of exposure to Korean smokers. Emissions data from five brands of cigarettes were tested under the ISO and "Canadian Intense (HCI)" smoking regimes, respectively. We conducted an analysis of 25 compounds containing nicotine, tar, carbonyls, phenolics, volatile organic compounds (VOCs), and semi-VOC cigarette smoke. Tar and nicotine showed levels of 4.3 to 5.8 mg/cig and 0.4 to 0.5 mg/cig, respectively, which are within the range of tolerance presented in ISO 8243. In the case of carbonyls, formaldehyde was detected within a range of 8.2 to $14.3{\mu}g/cig$, and acetaldehyde was present within a range of 224.7 to $327.2{\mu}g/cig$ under the ISO smoke regime. Crotonaldehyde was not detected under the ISO regime, and all of the carbonyls showed values 2.3 to 4.5 times higher under the HCI regime than those under the ISO regime. Catechol, which showed a level of 47.0 to $80.5{\mu}g/cig$ under the ISO regime and 117.5 to $184.7{\mu}g/cig$ under the HCI regime, was the highest constituent among the phenols. The amount of isoprene was 91.7 to $158.3{\mu}g/cig$ under the ISO regime and 221.0 to 377.0 under the HCI regime. To summarize, most of the constituents showed a tendency to be detected at levels 2 to 4 times higher under the HCI regime than under the ISO regime. Above all, these results represent the first analysis in Korea from an independent institute of tobacco companies under accreditation of ISO 17025.

Analysis on the contamination and source of VOCs in groundwaters of Gwangju area (광주광역시의 지하수 중 휘발성유기화합물(VOCs)의 오염과 오염원 분석)

  • Yun, Uk;Cho, Byong-Wook;Eum, Chul-Hun;Sung, Ik-Hwan
    • The Journal of Engineering Geology
    • /
    • v.13 no.4
    • /
    • pp.389-404
    • /
    • 2003
  • VOCs were detected in the 21 groundwaters out of 37 groundwaters sampled from around the Hanam Industrial Complex and the Gwangju stream. Ten components of chlorinated aliphatic hydrocarbons of VOCs were detected in the 18 groundwater samples. Among them, total trihalomethanes (TTHM) concentration is in the range of $0.1~36.2{\;}\mu\textrm{g}/L$, CECs concentration is $2.3~190{\;}\mu\textrm{g}/L$, and chlorinated solvents concentration containing PCE, TCE, etc. is $0.1~124.2{\;}\mu\textrm{g}/L$ respectively. Ten components of the aromatic hydrocarbons of VOCs were detected in the 5 groundwater samples, but their concentration are less than $1{\;}\mu\textrm{g}/L$. Detection frequency and concentration of the chlorinated aliphatic hydrocarbons components from the groundwaters in the Hanam Industrial Complex are higher than those of nearby downtown Gwangju stream. VOCs components except for TCE are lower than the MCL of USGS drinking water standard. TCE concentration of the 2 groundwater samples is over MCL, whose concentrations are 5 and 25 times higher than MCL, respectively. TCE is detected from the H8 and H10 groundwater samples and CFCs is detected H8 and H11 groundwater samples in the Hanam Industrial Complex. TTHM in study area is estimated from leakage of the main waters or sewage waters. Because most of the studied groundwater is under an aerobic condition, aromatic hydrocarbons are well degraded. But chlorinated aliphatic hydrocarbons are degraded very slowly.