• Title/Summary/Keyword: 5G-V2X

Search Result 332, Processing Time 0.035 seconds

A Study on AI-based MAC Scheduler in Beyond 5G Communication (5G 통신 MAC 스케줄러에 관한 연구)

  • Muhammad Muneeb;Kwang-Man Ko
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2024.05a
    • /
    • pp.891-894
    • /
    • 2024
  • The quest for reliability in Artificial Intelligence (AI) is progressively urgent, especially in the field of next generation wireless networks. Future Beyond 5G (B5G)/6G networks will connect a huge number of devices and will offer innovative services invested with AI and Machine Learning tools. Wireless communications, in general, and medium access control (MAC) techniques were among the fields that were heavily affected by this improvement. This study presents the applications and services of future communication networks. This study details the Medium Access Control (MAC) scheduler of Beyond-5G/6G from 3rd Generation Partnership (3GPP) and highlights the current open research issues which are yet to be optimized. This study provides an overview of how AI plays an important role in improving next generation communication by solving MAC-layer issues such as resource scheduling and queueing. We will select C-V2X as our use case to implement our proposed MAC scheduling model.

The Photoluminescence(PL) Spectroscopy and the Photo-Darkening(PD) Effect of the Amorphous SeGe Thin Films (비정질 SeGe 박막의 PL 특성과 광흑화 효과에 관한 연구)

  • 김진우;이현용;정홍배
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.5
    • /
    • pp.435-440
    • /
    • 2002
  • In this study, we have investigated photo-induced changes of optical energy gap( $E_{OP)}$ and photoluminescence (PL) in amorphous ($\alpha$-) S $e_{100-x}$G $e_{x}$ (x=5, 25 and 33) thin films prepared by conventional thermal evaporation method. In the $\alpha$-S $e_{100-x}$G $e_{x}$ thin film, the $E_{OP}$ is obtained by a linear extrapolation of the ($\alpha$hν)$^{\frac{1}{2}}$ versus hν plot to the energy axis using the optical absorption coefficient ($\alpha$) calculated from the extinction coefficient k measured in the wavelength range of 290~900nm. Although the values of $\Delta$ $E_{OP}$ are very different, all films exhibit photo-induced photo-darkening (PD) effect that is a red shift of $E_{OP}$ . In particular, $\Delta$ $E_{OP}$ in $\alpha$-S $e_{75}$ G $e_{25}$ thin film exhibits the largest value (i, e., $\Delta$ $E^{OP}$ ~40meV for $\alpha$-S $e_{95}$ G $e_{5}$ , $\Delta$ $E_{OP}$ ~200meV for $\alpha$-S $e_{75}$ G $e_{25}$ , $\Delta$ $E_{OP}$ ~130meV for $\alpha$-S $e_{67}$ G $e_{33}$ ). PL spectra in $\alpha$-SeGe by hν$_{HeCd}$ have no-Stokes shift (SS) and show a tendency dependent on both composition and illumination time. We explain the energy-induced phenomena such as the PD and thermal bleaching, the native charged-defect generation and the no-SS PL, etc..the PD and thermal bleaching, the native charged-defect generation and the no-SS PL, etc..tc..

Synthesis, Characterization and Ammonia Decomposition Reaction Activity of Vanadium Oxynitride Obtained from the Reduction/Nitridation of Vanadium Oxide (바나디움 산화물의 환원 및 질화반응으로부터 얻어진 바나디움 산화질화물의 제조, 특성분석 및 암모니아 분해반응에서의 촉매 활성)

  • Yun, Kyung Hee;Shin, Chae-Ho
    • Korean Chemical Engineering Research
    • /
    • v.60 no.4
    • /
    • pp.620-629
    • /
    • 2022
  • By varying various experimental conditions such as heating rate, molar hourly space velocity (MHSV), and nitridation reaction temperature, vanadium oxynitride was prepared through temperature programmed reduction/nitridation reaction (TPRN) of vanadium pentoxide and ammonia, and characterization were performed. In order to investigate the physico-chemical properties of the prepared catalyst, N2 adsorption-desorption analysis, X-ray diffraction analysis (XRD), hydrogen temperature programmed reduction (H2-TPR), temperature programmed oxidation (TPO), ammonia temperature programmed desorption (NH3-TPD), transmission electron microscopy (TEM) was performed. Transformation of V2O5 with 5 m2 g-1 low specific surface area by reduction at 340 ℃ to V2O3 showed a high specific surface area value of 115 m2 g-1 by micropore formation. As the nitridation temperature increased beyond that, the specific surface area continued to decrease due to sintering. The nitridation reaction variable that had the greatest influence on the specific surface area was the reaction temperature, and the x + y value of VNxOy of a single phase approached from 1.5 to 1.0 as the nitridation reaction temperature increased. At a high reaction temperature of 680 ℃, the cubic lattice constant a was VN. close to the value. At 680 ℃, the highest nitridation temperature among the experimental conditions, the ammonia conversion rate was 93%, and no deactivation was observed.

Isolation and Identification of Xylose fermenting Yeast (Xylose 발효효모의 분리 및 성질)

  • 김남순;서정훈
    • Microbiology and Biotechnology Letters
    • /
    • v.16 no.6
    • /
    • pp.505-509
    • /
    • 1988
  • Ethanol productivity of a xylose fermenting yeast (Candida sp. X-6-4l) isolated from soil was investigated in laboratory scale using Erlenmeyer flask and mini-jar tormentor. The optimal conditions of xylose fermentation in flask experiment were pH 4, asparagine as nitrogen source, xylose 20g/$\ell$, and in these condition, ethanol yield was about 80% to theoretical yield. Using mini-jar fermentor containing 5% total sugar with 2.5% xylose and 2.5% glucose, we obtained 2.3%(v/ v) ethanol and the corresponding efficiency was 72.3% of total sugar. In this case, the consumming speed of sugar under aerobic condition was faster than that of anaerobic condition, and glucose was used previously to xylose. The optimum concentration of xylose for ethanol fermentation in mini-jar fer-mentor scale was 5%, and the efficiency was 69% of total sugar(Alc.2.2% v/v).

  • PDF

A Study on V2V Communication Environment in K-city (자율주행 실험도시(K-city) 내 V2V 통신 환경에 관한 연구)

  • Jo, Byeongchan;Kim, Donghwan;Shin, Jaekon;Kim, Sungsub;Cho, Seongwoo
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.1
    • /
    • pp.26-30
    • /
    • 2021
  • K-city is an experimental area for developing self-driving cars. V2X communications such as WAVE, C-V2X and 5G are an essential technology for autonomous driving above level 4. In this paper, the research on the V2V communication environment was carried out through BSM receiving level analysis on the driving route in K-city. A stationary vehicle communicated with a test vehicle moving along urban area and suburban road in two different scenarios. The communication range and receiving levels obtained from this study will be used to develop and verify various safety scenarios using V2V communication within K-city in the future.

TECHNICAL STUDY ON THE CONTROLLING MECHANIQUES OF THE ENVIRONMENTAL FACTORS IN THE MUSHROOM GROWING HOUSE IN CHONNAM PROVINCE (전남지방(全南地方)에 있어서의 양송이 재배(栽培)에 최적(最適)한 환경조건(環境條件) 조절법분석(調節法分析)에 관(關)한 연구(硏究))

  • Lee, Eun Chol
    • Journal of Korean Society of Forest Science
    • /
    • v.9 no.1
    • /
    • pp.1-44
    • /
    • 1969
  • The important results which have been obtained in the investigation can be recapitulated as follows. 1. As demostrated by the experimental results and analyses concerning their effects in the on-ground type mushroom house, the constructions in relation to the side wall and ceiling of the experimental houses showed a sufficient heat insulation on effect to protect insides of the houses from outside climatic conditions. 2. As the effect on the solar type experimental mushroom house which was constructed in a half basement has been shown by the experimental results and analyses, it has been proved to be effective for making use of solar heat. However there were found two problems to be improved for putting solar houses to practical use in the farm mushroom growing: (1) the construction of the roof and ceiling should be the same as for the on-ground type house, and (2) the solar heat generating system should be reconstructed properly. A trial solar heat generating system is shown in Fig. 40. 3. Among several ventilation systems which have been studied in the experiments, the underground earthen pipe and ceiling ventilation, and vertical side wall and ceiling ventilation systems have been proved to be most effective for natural ventilation. 4. The experimental results have shown that ventilation systems such as the vertical side wall and underground ventilation systems are suitable to put to practical use as natural ventilation systems for farm mushroom houses. These ventilation systems can remarkably improve the temperature of fresh air which is introduced into the house by heat transfers within the ventilation passages, so as to approach to the desired temperature of the house without any cooling or heating operation. For example, if it is assuming that x is the outside temperature and y is the amount of temperature adjustment made by the influence of the ventilation system, the relationships that exist between x and y can be expressed by the following regression lines. Underground iron pipe ventilation system ${\cdots}{\cdots}$ y=0.9x-12.8 Underground earthen pipe ventilation system ${\cdots}{\cdots}$y=0.96x-15.11 Vertical side wall ventilation system${\cdots}{\cdots}$ y=0.94x-17.57 5. The experimental results have shown that the relationships existing between the admitted and expelled air and the $Co_2$ concentration can be described with experimental regression lines or an exponent equation as follows: 1) If it is assumed that x is an air speed cm/sec. and y is an expelled air speed in cm/sec. in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below: 2) If it is assumed that x is an admitted volume of air in $m^3/hr$ and y is an expelled volume of air in $m^3/hr$ in a natural ventilation system, since the y is a function of the x, the relationships that exist between x and y can be expressed by the regression lines shown below. 3) If it is assumed that the expelled air speed in cm/sec and replacement air speed in cm/sec. at the bed surface in a natural ventilation system are shown as x and y, respectively, since the y is a function of the x, the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}$ y=0.54X+0.84 4) If it is assumed that the replacement air speed in cm/sec. at the bed surface is shown as x, and $CO_2$ concentration which is expressed by multiplying 1000 times the actual value of $CO_2$ % is shown as y, in a natural ventilation system, since the y is a function of the x the relationships that exist between x and y can be expressed by the following regression line: G.E. (100%)- C.V. (50%) ventilation system${\cdots}{\cdots}$ y=114.53-6.42x 5) If it is assumed that the expelled volume of air is shown as x and the $CO_2$ concentration which is expressed by multiplying 1000 times the actual of $CO_2$ % is shown as y in a natural ventilation system, since the y is a function of of the x, the relationships that exist between x and y can be expressed by the following exponent equation: G.E. (100%)-C.V. (50%) ventilation system${\cdots}{\cdots}$ $$y=127.18{\times}1.0093^{-X}$$ 6. The experimental results have shown that the ratios of the crass sectional area of the G.E. and C.V. vent to the total cubic capacity of the house, required for providing an adequate amount of air in a natural ventilation system, can be estimated as follows: G.E. (admitting vent of the underground ventilation)${\cdots}{\cdots}$ 0.30-0.5% (controllable) C.V. (expelling vent of the ceiling ventilation)${\cdots}{\cdots}$ 0.8-1.0% (controllable) 7. Among several heating devices which were studied in the experiments, the hot-water boilor which was modified to be fitted both as hot-water toiler and as a pressureless steam-water was found most suitable for farm mushroom growing.

  • PDF

Amorphous-to-Crystalline Phase Transition of (InTe)x(GeTe) Thin Films ((InTe)x(GeTe) 박막의 비정질-결정질 상변화)

  • Song, Ki-Ho;Beak, Seung-Cheol;Lee, Hyun-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.23 no.3
    • /
    • pp.199-205
    • /
    • 2010
  • The crystallization speed (v) of amorphous (InTe)$_x$(GeTe) (x = 0.1, 0.3 and 0.5) films and their thermal, optical and electrical behaviors have been investigated using nano-pulse scanner (wavelength = 658 nm, laser beam diameter < 2 ${\mu}m$), X-ray diffraction (XRD), 4-point probe and UV-vis-IR spectrophotometer. These results were compared with those of $Ge_2Sb_2Te_5$ (GST) film, comprehensively utilized for phase-change random access memory (PRAM). Both v-value and thermal stability of (InTe)$_{0.1}$(GeTe) and (InTe)$_{0.3}$(GeTe) films could be enhanced in comparison with those of the GST. Contrarily, the v-value in the (InTe)$_{0.5}$(GeTe) film was so drastically deteriorated that we could not quantitatively evaluate it. This deterioration is thought because amorphous (InTe)$_{0.5}$(GeTe) film has relatively high reflectance, resulting in too low absorption to cause the crystallization. Conclusively, it could be thought that a proper compositional (InTe)$_x$(GeTe) films (e.g., x < 0.3) may be good candidates with both high crystallization speed and thermal stability for PRAM application.

A study on the characteristics and growth $Al_xGa_{1-x}Sb$ ($Al_xGa_{1-x}Sb$의 결정성장과 특성에 관한 연구)

  • 이재구;박민서;정성훈;송복식;문동찬;김선태
    • Electrical & Electronic Materials
    • /
    • v.10 no.3
    • /
    • pp.226-232
    • /
    • 1997
  • Ternary semiconductor $Al_{x}$G $a_{1-x}$ Sb crystals which have energy gap of 0.7eV-1.6 eV at room temperature according to the composition ratios were grown by the vertical Bridgman method. The characteristics of the crystals were investigated by XRD, HRTEM and Hall effect. The lattice constants of $Al_{x}$G $a_{1-x}$ Sb crystals were varied from 6.096A over .deg. to 6.135A over .deg. with the composition ratio x. The Hall effect of the $Al_{x}$G $a_{1-x}$ Sb crystals were measured by van der Pauw method with the magnetic field of 3 kilogauss at room temperature. The resistivities of Te-doped $Al_{x}$G $a_{1-x}$ Sb crystals were increased from 0.071 to 5 .OMEGA.-cm at room temperature according to the increment of the composition ratio x. The mobilies of $Al_{x}$G $a_{1-x}$ Sb crystals varied with the composition ratio x resulted in the following three different regions of GaSb-like (0.leq.x.leq.0.3), intermediate (0.3.leq.x.leq.0.4) and AlSb-like (0.4.leq.x.leq.l).q.l).q.l).q.l).

  • PDF

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2010.11a
    • /
    • pp.103-112
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system ($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.

  • PDF

A Study on the Safety of Electromagnetic Wave of Medical Imaging System (의료영상장치의 전자파 안전에 대한 연구)

  • Seon, Jong-Ryul;Lee, Won-Jeong;Rhim, Jae-Dong
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.67-72
    • /
    • 2010
  • This study was done to provide basic data on the safety of professionals in medical imaging system by measuring the electromagnetic waves generated in the medical imaging system being used in medical organization. The studied medical imaging systems were general X-ray system, computed tomography(CT), ultrasonographic(USG) system, magnetic resonance imaging(MRI), PET-CT and fluoroscopic(R/F) system, and through these devices, electric field and magnetic field were measured and analyzed. As a result of the analysis, the measured values classified by the medical organizations were not much significant, but in the measurement by the medical imaging systems, there were high hazard elements in the sequential order of electric field PET-CT($17.7{\pm}22.9$)v/m, CT($10.3{\pm}8.7$)v/m, general X-ray system($8.8{\pm}8.8$)v/m, magnetic field general X-ray system($5.06{\pm}8.26$)mG, CT($2.71{\pm}4.53$)mG and PET-CT($0.74{\pm}0.34$)mG, the systems that adopted X-ray as main ray source, and the more aged the medical imaging systems, the greater the effects of electro-magnetic waves($10.6{\pm}15.93v/m$ for 5 years or more, $6.14{\pm}5.60v/m$ for 5 years or less). The effects of electromagnetic waves on medical imaging systems or facilities were not much when the notification of ministry of knowledge economy is considered, but in the overall perspective considering all the equipments and facility of the medical organization, such effects were significant. It is determined that sustainable safety managements of electric field and magnetic field must be done during process from medical imaging system installation to maintenance to rule out such factors.