• Title/Summary/Keyword: 545 nm

Search Result 69, Processing Time 0.027 seconds

Simultaneous NO2 and RSP Measurements Using Filtration Method (필터방식을 이용한 이산화질소 및 호흡성 분진의 동시 측정)

  • Yang, Won-Ho;Im, Sung-Kuk;Kim, Moon-Hyeon
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.2
    • /
    • pp.148-152
    • /
    • 2008
  • Coated filters were developed to replace the glass impinger methods that use reagent solutions. The purpose of this study was to simultaneously measure nitrogen dioxide ($NO_2$) and respirable suspended particles (RSP) by a filtration method with a cyclone connected to a pump. A first pre-filter for RSP and second filter for $NO_2$, which was soaked in a TEA (Triethanolamine) solution, were loaded into a filter cassette with a pump flow rate of 1.7 l/m. After sampling, the TEA soaked filter was removed from the cassette, placed in a large test tube (10 ml), mixed, and allowed time to develop. The absorbance (abs) of the diazo compound of the $NO_2$ and N-(1-Napthylethylenediamine dihydrochloride) in the color reagent was measured at 545 nm on a spectrophotometer. The collection efficiency(%) of $NO_2$ by each 3 filter soaked in TEA solution and used in the cyclone with a pump flow rate 1.7 l/m was $89{\pm}3%$ and the correlation coefficient between the true $NO_2$ concentration and that determined by the TEA soaked filters was 0.993(p<0.001).

Phase Equilibria of Hydrates in Porous Media: Effect of Pore size and Salinity (다공성 매질에서의 하이드레이트 상평형 측정: 기공크기 및 염의 영향)

  • Lee, Seung-Min;Cha, In-Uk;Lee, Ju-Dong;Seo, Yong-Won
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.545-548
    • /
    • 2009
  • 최근 천연가스 개발의 중요성이 대두되면서 심해저 퇴적층에 존재하고 있는 천연가스 하이드레이트 개발에 많은 연구가 진행되고 있다. 본 연구에서는 심해저 퇴적층에 부존하는 가스 하이드레이트 조건과 유사하게 하기위해 3 wt% 농도의 염수를 다공성 실리카 젤 기공에 넣어 사용하였다. 기공의 직경에 따른 영향을 알아보기 위해 기공 직경이 각각 6.0, 15.0, 30.0 nm인 실리카 젤을 사용하여, 천연가스 주성분인 에탄, 프로판, 메탄+프로판 하이드레이트의 3상 (H-Lw-V) 평형을 측정하였다. 그 결과 기공의 크기가 작아질수록 각각의 벌크 상태의 에탄, 프로판, 메탄+프로판 하이드레이트에 비해 하이드레이트의 평형조건이 온도는 낮아지고 압력이 높아지는 저해효과가 커짐을 알 수 있었다. 실험값으로 부터 기공 내의 물과 하이드레이트상 사이의 계면장력 값을 Gibbs-Thomson식에 의해 구할 수 있으며, 열역학 계산을 통하여 실험값과 비교하였다. 본 연구에서 얻어진 결과는 심해저 천연가스 개발, 이산화탄소 심해저장 등의 가스 하이드레이트 응용 연구에 유용한 기초 자료가 될 것이다.

  • PDF

The Dispersion Stability of Multi-Walled Carbon Nanotubes in the Presence of Poly(styrene/$\alpha-methyl$ styrene/acrylic acid) Random Terpolymer

  • Chang, Woo-Hyuck;Cheong, In-Woo;Shim, Sang-Eun;Choe, Soon-Ja
    • Macromolecular Research
    • /
    • v.14 no.5
    • /
    • pp.545-551
    • /
    • 2006
  • Aqueous dispersions of pristine and functionalized (COOH- and $NH_2$-) multi-walled, carbon nanotubes (MWNTs) were prepared by using three types of surf act ants: sodium dodecyl sulfate (SDS, anionic), PEO-PPO-PEO (Pluronic P84, non-ionic), and poly(styrene/$\alpha-methyl$ styrene/acrylic acid) random terpolymer, i.e., alkali-soluble resin (ASR). The aggregate size, $\zeta-potential$, and storage stability of the MWNT aqueous dispersions were investigated by using dynamic light scattering and the turbidity method at room temperature. The exfoliation of the MWNT aggregates was determined by a UV-visible spectrophotometer and the morphology of the surfactant-coated MWNTs was observed by transmission electron microscopy (TEM). In all cases, ASR showed better dispersion stability with the smallest aggregate size, compared with the other surfactants, because of its unique molecular structure, i.e., randomly incorporated carboxylic acid groups and planar phenyl groups that can be irreversibly and effectively adsorbed on the MWNT surface. A predominantly-exfoliated morphology of MWNTs was observed in the presence of ASR from the strong intensity of the UV-vis spectrum at 263 nm.

Emission Properties of Electro luminescent Devices using Poly(3-hexylthiophene) Deposited by LB Method (LB법으로 첨가한 Poly(3-hexylthiophene)을 발광층으로 사용한 전계발광소자의 발광특성)

  • 김주승;이경섭;구할본
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.9
    • /
    • pp.757-761
    • /
    • 2001
  • We studied emitting properties of organic electroluminescent devices fabricated using the spin-coating and Langmuir-Blodgett(LB) technique. The LB technique has the advantage of precise control of the thickness better than spin-coating method. LB monolayer of poly(3-hexylthiophene)(P3HT) was deposited 27 layers onto the indium-tin-oxide(ITO) substrate as Y-type films by the vertical dipping method. In the absorption spectra, the λ$\_$max/ of P3HT-AA LB films and of spin-coating films showed about at 510, 545 and 590 nm corresponding to 2.43, 2.28, 2.10eV. And we observed that the turn-on voltage of devices deposited by LB method(10V) was higher than that of spin-coating method(8.5V) in voltage-current-luminance characteristic. In the logV-logJ characteristics of ITO/P3HT-AA LB/Al device, we confirmed that El device fabricated by LB method follows three conduction mechanisms: ohmic, space-charge-limited current(SCLC) conduction and trapped-carrier-limited space-charge current(TCLC) conduction.

  • PDF

Measurement of Urine Enzymes for the Early Diagnosis of Nephrosis in Ruminants 1. Optimal Conditions for Measurement of Enzyme Activities and Normal Ranges (반추동물 신증의 조기진단을 위한 뇨효소 측정법 1. 효소활성도 측정을 위한 적합한 조건과 정상범위에 관하여)

  • Lee Chang-Woo;Lee Kyoung-Kap
    • Journal of Veterinary Clinics
    • /
    • v.6 no.2
    • /
    • pp.291-305
    • /
    • 1989
  • Present experiment was performed to establish the optimal reaction conditions for measurement of urinary gamma-glutamyltranspeptidase(${\gamma}$-GTP), N-acetyl-${\beta}$-D-glucosaminidase (AGS) and alanine aminopeptidase(AAP) activities in bovine and to investigate in vitro stability of the enzymes, within-run imprecision of the methods, and normal ranges. 1. The optimal wavelength for measurement of ${\gamma}$-GTP activity was 545nm. 2. The optimal pH of Tris-HCI buffer containing glycylglycine for measurement of urinary ${\gamma}$-GTP activity was 7.6~7.8(37$^{\circ}C$). 3. Coefficient of variance for within-run imprecision of urinary ${\gamma}$-GTP activity ranged from 4.8 to 7.2% and there was no significant difference among replications, 4. The optimal wavelength for measurement of urinary AGS activity was 405nm. 5. The optimal pH of citrate buffer for measurement urinary of AGS activity was 4.0(37$^{\circ}C$). 6. Coefficient of variance for within-run imprecision of urinary AGS activity ranged from 3.9 to 6.1% and there was no significant difference among replications. 7. The optimal wavelength for measurement of urinary AAP activity was 400nm. 8. The optimal pH of phosphate buffer for measurement of urinary AAP was 7.8. 9. Coefficient of variance for within-run imprecision of urinary AAP activity ranged from 2.5 to 4.8% and there was no significant difference among replications. 10. ${\gamma}$-GTP and AGS activities were increased significantly by gel-filtration. 11. Turbidity interfered with measurement of urinary AAP activity in bovine unless the specimen was gel-filterated. 12. Preservation of the specimen at 5$^{\circ}C$ or -20$^{\circ}C$ did not affect the AGS activity at least for 7 days after collection. 13. Preservation of the specimen at 5$^{\circ}C$ or 20$^{\circ}C$ did not affect the ${\gamma}$-GTP and AAP activities statistically, but some individual specimens revealed fluctuation during preservation. 14. ${\gamma}$-GTP, AGS and AAP activities revealed fluctuation by the tine of the day when the specimen was collected. 15. The normal ranges of urinary ${\gamma}$ -GTP, AGS and AAP activities were 6.60${\pm}$3.26(2.36-14.50), 1.31 ${\pm}$ 0.81(0.33-3.78), and 1.73 ${\pm}$ 0.55(0.77-3.03)U/l. respectively.

  • PDF

The Electro-optical Propeties of Multilayer EL devices by blending TPD with P3TH as Emitting layer (TPD와 P3HT의 블렌드한 다층막 EL 소자의 전기-광학적 특성)

  • Kim, Dae-Jung;Gu, Hal-Bon;Kim, Hyung-Kon;Park, Gye-Choon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.542-545
    • /
    • 2002
  • High performance organic electroluminescnet(EL) devices which are composed of organic thin multilayer films are fabricated. The basic structure is ITO/Emitting layer/LiF/Al in which have a blended emitting layer. The emitting layer is consisted of a host material(N,N' diphenyl-N,N' (3-methyl phenyl)-l,l'-biphenyl-4,4'diamine)(TPD)) and a guest emitting material(poly(3-hexylthiophehe)(P3HT)). We think that the energy transfer in blending layer occurred from TPD to P3HT. Red emitting multilayer EL devices were fabricated using tris(8-hydroxyqunolinate) aluminum$(Alq_3)$ as electron transport material. The device structure of ITO/blending layer(TPD+P3HT)$/Alq_3$/LiF/Al was employed. In the Voltage-current-luminance characteristics of multilayer device, the device tum on at the 2V and the luminance of $10{\mu}W/cm^2$ obtain at l0V. Red emission peak at 640nm was observed with this device structure. We have presented evidence that the excitation energy migration between a polymeric host and guest has to be explained. And by using multilayer, the red light emitting EL device enhances not only Voltage-current-luminance characteristic but also stability of device.

  • PDF

Dynamic Deformation Behavior of Ultra-Fine-Grained Pure Coppers Fabricated by Equal Channel Angular Pressing (ECAP으로 제조된 초미세립 순동의 동적 변형거동)

  • Kim, Yang Gon;Hwang, Byoungchul;Lee, Sunghak;Lee, Chul Won;Shin, Dong Hyuk
    • Korean Journal of Metals and Materials
    • /
    • v.46 no.9
    • /
    • pp.545-553
    • /
    • 2008
  • Dynamic deformation behavior of ultra-fine-grained pure coppers fabricated by equal channel angular pressing (ECAP) was investigated in this study. Dynamic torsional tests were conducted on four copper specimens using a torsional Kolsky bar, and then the test data were analyzed by their microstructures and tensile properties. The 1-pass ECAP'ed specimen consisted of fine dislocation cell structures elongated along the ECAP direction, which were changed to very fine, equiaxed subgrains of 300~400 nm in size as the pass number increased. The dynamic torsional test results indicated that maximum shear stress increased with increasing ECAP pass number. Adiabatic shear bands were not found at the gage center of the dynamically deformed torsional specimen of the 1- or 4-pass ECAP'ed specimen, while some weak bands were observed in the 8-pass ECAP'ed specimen. These findings suggested that the grain refinement according to the ECAP was very effective in strengthening of pure coppers, and that ECAP'ed coppers could be used without serious reduction in fracture resistance under dynamic torsional loading as adiabatic shear bands were hardly formed.

Mossbauer Study Of $Co{1+x}Fe{2-2x}Ti_xO_4$ ferrite Powders (Mossbauer 분광법에 의한 $Co{1+x}Fe{2-2x}Ti_xO_4$ 페라이트 분말의 연구)

  • 채광표;정성근;김원기;이성호;이영배
    • Journal of the Korean Magnetics Society
    • /
    • v.10 no.5
    • /
    • pp.220-224
    • /
    • 2000
  • Ultra-fine $Co_{1+x}$F $e_{2-}$2x/ $Ti_{x}$ $O_4$ferrite powders have been prepared by the sol-gel method. The crystallographic and magnetic properties of the sample have been investigated by means of x-ray diffraction, Mossbauer spetroscopy and vibrating sample magnetometry. The formation of nano crystallized particles is confirmed. The x-ray diffractions of all samples with various compositions clearly indicate the presence of spinel structure. The Mossbauer spectra could be fitted as the superposition of two sextets due to F $e^{3+}$ A-site and B-site. The IS and QS values nearly constant with substituted Co-Ti contents, whereas $H_{hf}$ of B-site decreases with increasing Co-Ti substitution in $Co_{1+x}$F $e_{2-}$2x/ $Ti_{x}$ $O_4$. The magnetic behaviour of powders shows that the saturation magnetization and the coercivity decrease with increasing x in $Co_{1+x}$F $e_{2-}$2x/ $Ti_{x}$ $O_4$.$.X>.

  • PDF

Estimation of Number of Synapses on a Neuron in the Brain Using Physical Bisector Method (Physical disector를 이용한 신경세포 및 신경연접 수의 측정)

  • Lee, Kea-Joo;Rhyu, Im-Joo
    • Applied Microscopy
    • /
    • v.36 no.2
    • /
    • pp.83-91
    • /
    • 2006
  • The number and structure of synapses are dynamically changed in response to diverse physiological and pathological conditions. Since strength of synaptic transmission is closely related to the synaptic density on a neuron, both synaptogenesis and synapse loss may play important roles in controlling neuronal activity. Thus it is essential to estimate the number of synapses using an accurate quantitative method for better understanding of the numerical alteration of synapses under terrain experimental conditions. We applied physical disector principle to estimating the number of synapses per neuron in the dentate gyrus of adult mice. First, we measured the numerical density of granule cells using the physical disector principle. Second, the density of medial perforant path to granule cell synapses was estimated using the bidirectional physical disector. Then, the volume ratio of molecular layer to granule cell layer was measured. With these numerial values, we successfully calculated the number of synapses per neuron. Individual granule cells have approximately 6500 synapses in the dentate gyrus of adult mice $(6,545{\pm}330)$, which are comparable to those of other researchers. Our results showed that the estimation of synapse numbers per neuron using the physical disector principle would provide accurate and precise information on the numerical alteration of synapses in diverse physiological and pathological conditions. Following analyses of synapse numbers using this method will contribute to the better understanding of structural synaptic plasticity in a variety of experimental animal models.