• Title/Summary/Keyword: 5-MW

Search Result 998, Processing Time 0.026 seconds

Model Test of a TLP Type of Floating Offshore Wind Turbine, Part II

  • Dam, Pham Thanh;Seo, Byoung-Cheon;Kim, Jae-Hun;Shin, Jae-Wan;Shin, Hyunkyoung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.38.2-38.2
    • /
    • 2011
  • A large number of offshore wind turbines with fixed foundations have been installed in water depths up to 30 meters supporting 3-5MW wind turbines. Some floating platform concepts of offshore wind turbines were designed to be suitable for deployment in water depths greater than 60 meters. However the optimal design of this system in water depth 50 meters remains unknown. In this paper, a 5-MW wind turbine located on a TLP type platform was suggested for installation in this water depth. It is moored by a taut mooring line. For controlling the wind turbine always be operated at the upwind direction, one yaw controlling was attached at the tower. To study motion characteristics of this platform, a model was built with a 1/128 scale ratio. The model test was carried out in various conditions, including waves, winds and rotating rotor effect in the Ocean Engineering Wide Tank of the University Of Ulsan (UOU). The characteristic motions of the TLP platform were captured and the effective RAOs were obtained.

  • PDF

Sythesis of Highly Branched Isomaltodextrin by Acceptor Reaction using Dextransucrases from L. mesenteroides B-742CB and B-512FMCM (Leuconostoc mesenteroides B-742CB와 B-512FMCM Dextransucrase의 수용체 반응을 이용한 고분지 Isomaltodextrin의 생산)

  • 김문수;이선옥;류화자;강희경;유선균;장석상;김도원;김도만;김성혁
    • KSBB Journal
    • /
    • v.16 no.2
    • /
    • pp.200-206
    • /
    • 2001
  • In this study we tried to optimize the enzyme reaction conditions for the synthesis of highly branched isomaltodextrin (Mw > 2.5 kDa) using two dextransucrases from L. mesenteroides B-742CB and B-512FMCM that are dextransucrase constitutive mutants. As the concentration of sucrose or the ratio of maltose to sucrose increased, the amount of dextran decreased and the number and the amount of acceptor-products (of sucrose or maltose) increased. With high sucrose concentration (over 34%), there was more branched isomaltodextrin (as acceptor products) than dextran. When the ratio of sucrose to maltose was 2.5, there produced 86.7% of isomaltodextrin were produced. The Mw of dextrans, however, was over 2${\times}$10(sup)6 and there was no significant amounts of branched clinical dextran or high molecular weight oligosaccharides. With the combined activities of B-742CB dextransucrase and B-512FMCM dextransucrase we could synthesize high molecular weight branched isomaltodextrin (Mw>2.5 kDa). The high molecular weight dextran was composed of high branches as B-742CB dextran.

  • PDF

A Study on the Effect of Low Pass Filter and Drive Train Damper for the NREL 5MW Wind Turbine Control (NREL 5MW 풍력터빈 제어용 저주파 통과 필터와 드라이브 트레인 댐퍼의 효과 고찰)

  • Lim, Chae-Wook
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.24 no.4_2
    • /
    • pp.443-451
    • /
    • 2021
  • It is essential to examine and analyze the power output and load responses together using real-world turbulent wind speeds. In this paper, the power controller and the drive train damper are simultaneously considered using the NREL 5MW wind turbine model, and the damage equivalent load(DEL) of the low speed shaft torque and power output responses according to the natural frequency of the second order low pass filter are simultaneously investigated. Numerical testing is carried out above rated wind speed using commercially available Bladed software. From the viewpoints of DEL reduction of the drive train shaft torque and power output responses, it is shown that the natural frequency of the low pass filter is appropriately about 6 to 10rad/s. And the reduction ratio of the DEL of the low-speed shaft torque decreases as the wind speed becomes higher, and it is confirmed that the reduction ratio is limited to about 20% at high wind speeds.

Structural integrity of a 2.5-MW spar-type floating offshore wind turbine under extreme environmental conditions

  • Hanjong Kim;Jaehoon Lee;Changwan Han;Seonghun Park
    • Wind and Structures
    • /
    • v.37 no.6
    • /
    • pp.461-471
    • /
    • 2023
  • The main objective of this study was to establish design guidelines for three key design variables (spar thickness, spar diameter, and total draft) by examining their impact on the stress distribution and resonant frequency of a 2.5-MW spar-type floating offshore wind turbine substructure under extreme marine conditions, such as during Typhoon Bolaven. The current findings revealed that the substructure experienced maximum stress at wave frequencies of either 0.199 Hz or 0.294 Hz, consistent with previously reported experimental findings. These results indicated that the novel simulation method proposed in this study, which simultaneously combines hydrodynamic diffraction analysis, computational dynamics analysis, and structural analysis, was successfully validated. It also demonstrated that our proposed simulation method precisely quantified the stress distribution of the substructure. The novel findings, which reveal that the maximum stress of the substructure increases with an increase in total draft and a decrease in spar thickness and spar diameter, offer valuable insights for optimizing the design of spar-type floating offshore wind turbine substructures operating in various harsh marine environments.

Quantitative Wear Training for the Improvement of Heat Tolerance in Summer (Part II) -Wear Training by Optimal Temperature Inside Clothing for Women in Their 20s- (여름철 내열성 증진을 위한 정량적 착의훈련의 효과 (제2보) -20대 여성의 의복내 온도를 지침으로-)

  • Lee, Hyo-Hyun;Choi, Jeong-Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.4
    • /
    • pp.371-381
    • /
    • 2012
  • This study investigates quantitative wear training effects and involved 15 participants from a previous study (part 1) in May to September 2009. Before wear training, the subjects' rectal temperature, skin temperature, heart rate, blood pressure and local sweating were measured for 1 hour in a climate chamber ($39{\pm}1^{\circ}C$, $65{\pm}5%RH$, 0.3m/s) to evaluate heat tolerance. Subsequently, the subjects were divided into 3 groups that consisted of 5 participants. Group N (control-group) dressed the participants so that they felt comfortable (or cool). Group W and MW where participants underwent regular wear training for 10 weeks (5 days a week a total of 50 times). The intensity of the wear training for the participants of group MW was stronger than that for group W. A heat-tolerance experiment was performed after wear training. The results were as follows: 1. The participants of groups W and MW felt more comfortable after wear training than before wear training in the case of warmer $T_{cl}$. However, no significant differences were observed before and after wear training for group N. 2. The heat tolerance of the participants of groups W and MW was higher after wear training than before wear training. However, no significant difference was noted in this regard for group N. 3. The results showed the wear training effect (based on quantitative guidelines). The results show that the predicted optimal temperature inside clothing can enhance heat tolerance.

Contractile Effects of Hemoglobin-Free Human Cerebrospinal Fluid on Isolated Porcine Cerebral Arteries

  • Baik, Yung-Hong;Kang, Seon-Young;Kook, Hyun;Chyung, Sang-Keun;Kook, Young-Johng;Kang, Sam-Suk
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.2 no.2
    • /
    • pp.193-199
    • /
    • 1998
  • To elucidate the mechanism involved in the cerebral vascular spasm following subarachnoid hemorrhage (SAH), the effects of the cerebrospinal fluid (CSF) obtained from the SAH patients on the resting tension and its influence on the contractile responses to various vasoactive agents and to hypoxia were investigated in isolated porcine cerebral arteries. All the CSFs containing hemoglobin (Hb) produced contraction and some Hb-free CSFs also elicited contraction. When the Hb-free CSF was separated by microfilter, the filtrate of <30,000 MW did not produce contraction, while the fraction above 30,000 MW elicited more marked contractile responses than the unfractionated CSF. The CSF contraction was significantly attenuated in the presence of indomethacin or nimodipine, whereas the contractions induced by KCl, prostaglandin $F_{2{\alpha}}$ ($PGF_{2{\alpha}}$), or endothelin-1 (ET-1) were not affected by the CSF pretreatment. However, the contractile responses induced by 5-hydroxytryptamine (5-HT) and phenylephrine (PE) were markedly potentiated by the pretreatment. Hypoxia-induced vasoconstriction was significantly potentiated by the pretreatment with either unfractionated CSF or the CSF fraction of above 30,000 MW. These results suggest that unknown vasocontractile substance(s) exists in the Hb-free CSF and that the substance, with its MW above 30,000, is activated by hypoxia and acts synergistically with 5-HT and PE, and that extracellular calcium influx and cyclooxygenase are also involved in the cerebral vasoconstrictory effect of Hb-free CSF.

  • PDF

Characterization of NOM Behavior and DBPs Formation in Water Treatment Processes (정수처리공정에서 NOM 거동과 소독부산물 발생특성)

  • Kim, Sang Eun;Gu, Yeun Hee;Yu, Myong Jin;Chang, Hyun Seong;Lee, Su Won;Han, Sun Hee
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.4
    • /
    • pp.395-407
    • /
    • 2007
  • Disinfection by-products(DBPs) are formed through the reaction between chlorine and natural organic matter(NOM) in water treatment. For reducing the formation of chlorinated DBPs in the drinking water treatment, there is a need to evaluate the behavior of NOM fractions and the occurrence of DBPs for each fraction. Among the six fractions of NOM, the removal of HPOA and HPIN got accomplished through coagulation and sedimentation processes. Advanced water treatment processes were found to be most significant to remove the HPOA and HPON. It was found that HPOA made the most THMFP level than any other fractions and HPIA and HPOA formed higher HAAFP. The fraction of NOM with MW less than 1k Da was 32.5~54.3% in intake raw water. Mostly the organic matter with MW more than 1k Da was removed through coagulation and sedimentation in the drinking water treatment processes. In case of advanced water treatment processes, the organic matter with MW 1k~100k Da decreased by means of ozone oxidation for high molecular weight substances. As the result low molecular organic matter increased. In the BAC and GAC processes, the organic matter with MW less than 100k Da decreased.

Development of a Electrical Converter for Tidal-Current Power Plant with 1.2MW Doubly-fed Induction Generator (조류발전용 1.2MW 권선형유도발전기 제어를 위한 전력변환장치 개발)

  • Park Jungwoo;Lee Kiwook;Kim Dongwook;Yum Kidai;Lee Kwangsoo;Park Jinsoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.520-523
    • /
    • 2005
  • 국내에서 대체에너지 공급 비율을 보면 청정에너지로 분류할 수 있는 태양열에너지, 태양 광 에너지, 풍력에너지를 모두 합하여 대체에너지의 $10\%$이하이며, 대체에너지 비율의 $90\%$ 이상을 폐기물로부터 얻은 에너지가 차지하고 있는 실정이다. 신재생에너지원에는 여러 종류가 있지만 해양에너지원에 대해 대상을 설정하고 이에 대한 부존량을 살펴보면 진도 주변의 해역에서 조류발전 부존량이 약 362만 kW가 되며, 시화호와 새만금 등지에서의 조력발전 부존량이 650만 kW, 동해안 후포 연안을 비롯한 파력발전 부존량이 20만kW가 되는 것으로 알려져 있다. 이에 따라 해양에너지를 실용화하기 위한 연구가 국내외에서 연구되고 있다. 본 논문은 권선형유도발전기를 갖는 조류발전 시스템을 대상으로 연구한 결과로 권선형유도발전기를 제어하기 위한 전력변환장치 개발과 관련한 내용이다. 신재생에너지원이 발전 단가 측면에서 경제성을 갖기 위해서 발전기 용량은 5MW 급까지 대용량화되어 있는 단계이지만 국내에서는 아직 MW급 이상이 되는 권선형 유도발전기와 권선형 유도발전기를 제어하는 전력변환장치에 대한 연구 실적이 없는 상황이다 이에 본 논문에서는 1MW급의 권선형유도발전기에 대한 개발 사례를 소개하면서 유효전력제어, 역률제어, 계통연계방법, 그리고 운전 속도에 따라 변동되는 회전자측에서의 피상전력 특성 등을 제시하고자 한다.

  • PDF

An Assessment of Energy and Environmental Impacts of Fuel Cell Generation (연료전지를 이용한 발전기술의 에너지-환경 파급효과)

  • Kim, Ho-Seok;Kim, Jeong-In;Choo, Min-Jeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.268-272
    • /
    • 2005
  • 현재 국내 수소 관련 연구는 생산, 운반, 저장 등 공급과정의 기술과 발전, 수송 등 이용기술을 중심으로 이루어지고 있다. 본 연구에서는 현재 개발 중인 MCFC 발전설비에 대한 기술 및 비용 특성을 이용하여 LEAP모형시스템 기반의 ROK2003-H2 모형을 구축하고 정부의 '제2차 신재생에너지 기술개발 및 이용보급 기본계획$(2003\~2012)$'의 계획에 따른 수소에너지(연료전지) 보급의 에너지/환경부문 파급효과를 분석한다. 분석 대상이 되는 기술은 Molten Carbonate 연료전지를 이용한 2MW급 발전기술로, 2008년 70MW가 설치되기 시작하여 2011년까지 매년 100MW증설되어 2011년 전체 설비가 370MW에 이르는 것으로 시나리오를 구축한다. 설비의 에너지효율성은 연료전지 발전설비가 처음 도입된 2008년에는 $45\%$로 가정하고 2009년-2011년 간에 $5\%$씩 상승되어 2011년에는 $60\%$에 이를 것으로 전망한다. 분석결과에 의하면 2011년에 연료전지의 발전설비를 370MW로 확대하는 경우에 CO를 비롯한 대부분의 대기오염배출량이 감소하며, 온실가스 배출량 역시 35,433백만tC로 약 295백만tC가 감소한다.

  • PDF

Operation Characteristic and Harmonic Analysis of 200-MW Modulator (200-MW 모듈레이터의 동작 특성 및 고조파 해석)

  • Park, S.S.;Oh, J.S.;Cho, M.H.;NamKumg, W.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1577-1579
    • /
    • 1994
  • 200-MW pulse modulators(total 11units) for the PLS linac employ the SCR phase control circuit. It controls 3-phase AC line voltage for the high-voltage DC power supply (DCPS, maximum of 25kVDC, 4.2A) which charges the pulse forming network(PFN). The PFN delivers 400kV, 500A, ESW $7.5{\mu}s$ pulse power to the 80-MW klystron amplifier tube. The SCR regulates 3-phase AC power and feeds to the high voltage transformer. Two different types of the transformer configurations namely ${\Delta}-{\Delta}$ and ${\Delta}-Y$, are alternatively installed to 11 modulator units for the suppression of harmonic noises. RC filters and reactors are also installed. Currently, approximately 110-kW of average AC power per unit is consumed at the normal operation level of the modulator with 30pps. This paper presents the operational characteristics of the high power pulse modulator, especially the experimental results of the AC line harmonic components generated by the operation of the high power pulse modulator to suppress the switching noises from the SCR and rectifying diode arrays.

  • PDF