• 제목/요약/키워드: 5공 프로우브

검색결과 5건 처리시간 0.017초

저 Reynolds 수 영역에서 Reynolds 수가 5공 프로우브의 보정에 미치는 영향 (The Effect of Reynolds Number on the Calibration of a Five-Hole Probe at Low Reynolds Numbers)

  • 이상우;전상배
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2000년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.193-199
    • /
    • 2000
  • The effects of Reynolds number on the non-nulling calibration of a cone-type five-hole probe in low-speed flows have been investigated at the Reynolds numbers of $2.04{\times}10^3,\;4.09{\times}10^3$, and $6.13{\times}10^3$. The calibration is conducted at the pitch and yaw angles in ranges between -35 degrees and 35 degrees with an angle interval of 5 degrees. The result shows that each calibration coefficient, in general, is a function of the pitch and yaw angles, so that the pre-existing calibration data in a nulling mode are not enough in accounting for the full non-nulling calibration characteristics. Due to the interference of the probe stem, the calibration coefficients have more Reynolds number sensitivity at positive pitch angles than at negative ones.

  • PDF

넓은 입력 다이너믹 영역을 가지는 상호이득변조 방식의 전광 파장전환기 (All Optical Wavelength Converters Based on XGM for Wide Input Power Dynamic Range)

  • 방준학;이상록;이성은;이종현
    • 전자공학회논문지D
    • /
    • 제36D권8호
    • /
    • pp.62-67
    • /
    • 1999
  • 본 논문에서는 반도체 광 증폭기내에서 상호 이득변조 방식을 이용한 파장변환기의 입력 다이너믹 영역을 넓히기 위한 구조를 제안하였다. 파장변환기에서의 성능의 척도가 되는 파워 패널티에 대한 입력 펌프 및 프로우브 광 세기의 영향을 조사하였으며, 그 결과 프로우브광의 세기가 펌프광의 세기보다 약 3 dB, 낮은 경우에 최적의 BER 성능을 보였다. 이러한 특성을 이용하여 입력 펌프광의 세기를 감지하고 그에 따라 프로우브 광원에 가해지는 바이어스 전류로 프로우브 광의 세기를 제어하는 파장변환기 구조를 제안하였다. 따라서 넓은 입력 다이너믹 영역을 가지는 파장변환기를 구현할 수 있으며, 2.5 Gb/s 광신호에 대해 20 dB 이상의 입력 다이너믹 영역을 얻었다.

  • PDF

5공프로우브의 보정에 영향을 주는 유동변수들에 대한 실험적 연구 (Experimental investigation of flow parameters influencing the calibration of five-hole probes)

  • 이상우;윤태진
    • 대한기계학회논문집B
    • /
    • 제21권5호
    • /
    • pp.637-649
    • /
    • 1997
  • Effects of cone angle, pressure-hole orientation and Reynolds number on the five-hole probe calibration have been investigated for eight large-scale conical five-hole probes, which have either perpendicular pressure holes or forward-facing pressure holes for the cone angles of 45 deg, 60 deg, 75 deg and 90.deg. Pitch and yaw angles are changed from -40 deg to +40 deg with an interval of 5 deg, respectively, when the probe Reynolds numbers are 1.77*10$^{4}$, 3.53*10$^{4}$ and 7.06*10$^{4}$. The result shows that larger cone angle results in more sensitive changes in the calibration coefficients. In the case that the cone angle is 45 deg, the pitch-angle and yaw-angle coefficients of the five-hole probe with the perpendicular pressure holes show a very different trend compared with those of the five-hole probe with the forward-facing pressure holes. On the other hand, when the cone angle is more than 60 deg, each calibration coefficient is nearly independent of the pressure-hole orientation. Additionally, the effects of the Reynolds number on the calibration coefficients are also reported in detail.

엇회전식 축류홴의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Counter-Rotating Axial Fan)

  • 최진용;조이상;조진수;원유필
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.441-446
    • /
    • 2000
  • The experiments of the Aerodynamic characteristics of a counter-rotating axial fan were carried out. The performance tests of a single and a counter-rotating axial fan were carried out based on the Korean Standard Testing Methods for Turbo-fans and Blowers(KS B 6311). The performances of single and counter-rotating axial fans were obtained and compared with each other. The flow fields of a counter-rotating axial fan at the peak efficiency point were measured using a five-hole probe. As a result, compared with the performance of a single-rotating axial fan, that of a counter-rotating axial fan was superior. And it is confirmed that most of the swirl flow generated by the front rotor was eliminated by the rear rotor.

  • PDF

2단 축류팬과 엇회전식 축류팬의 공력 특성에 관한 실험적 연구 (Experimental Study on the Aerodynamic Characteristics of a Two Stage and a Counter-Rotating Axial Flow Fan)

  • 조이상;조진수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.541-547
    • /
    • 2000
  • Experiments were done for the comparison of performance and flow characteristics between a two stage axial flow fan and a counter-rotating axial flow fm. The fan performance curves were obtained by the Korean Standard Testing Methods for Turbo Fans and Blowers (KS B 6311). The fan flow characteristics were measured using a five-hole probe by the non-nulling method. Each stage of the two stage axial flow fan used for the present study has an eight bladed rotor and thirteen stator blades. The front and the rear rotor of the counter-rotating axial flow fan have eight blades each and are driven by coaxial counter rotating shafts through a gear box located between the rear rotor and the electric motor. Both of the two axial fan configurations use identical rotor blades and the same operating conditions for the one-to-one comparison of the two. Performance characteristics of the two configurations were obtained and compared by varying the blade setting angles and axial gaps between the blade rows. The passage flow fields between the hub and tip of the fans were measured and analyzed for the particular operating conditions of peak efficiency, minimum and maximum pressure coefficients.

  • PDF