Consideration on Measured Patients Dose of Three-Dimensional and Four-Dimensional Computer Tomography when CT-Simulation to Radiation Therapy (방사선치료를 위한 CT 검사 시 3DCT와 4DCT에 대한 피폭선량 고찰)

  • Park, Ryeong-Hwang;Kim, Min-Jung;Lee, Sang-Kyu;Park, Kwang-Woo;Jeon, Byeong-Cheol;Cho, Jeong-Hee;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.34 no.4
    • /
    • pp.341-349
    • /
    • 2011
  • This study was to measure the patient dose difference between 3D treatment planning CT and 4D respiratory gating CT. Study was performed with each 10 patients who have lung and liver cancer for measured patient exposure dose by using SOMATON SENSATION OPEN(SIMENS, GERMANY). CTDIvol and DLP value was used to analyze patient dose, and actual dose was measured in the location of liver and kidney for abdominal examination and lung, heart and spinal cord for chest examination. Rando phantom were used for the experiment. OSLD was used for in-vitro and in-vivo dosimetry. Increasing overall actual dose in 4D respiratory gated CT-simulation using OSLD increase the dose by 5.5 times for liver cancer patients and 6 times for lung cancer patients. In CT simulation of 10 lung cancer patients, CTDIvol value was increased by 5.7 times and DLP 2.4 times. For liver cancer patients, CTDIvol was risen by 3.8 times and DLP 1.6 times. The accuracy of treatment volume could be increased in 4D CT planning for position change due to the breaths of patient in the radiation therapy. However, patients dose was increased in 4D CT than 3D CT. In conclusion, constant efforts is required to reduce patients dose by reducing scan time and scan range.

Digital Watermark Based Error Detection for MPEG-4 Bitstream Error

  • Hiroyuki Okada;Shiitev, Altan-Erdene;Song, Hak-Sop;Gen Fujita;Takao Onoye;Isao Shirakawa
    • Proceedings of the IEEK Conference
    • /
    • 2002.07a
    • /
    • pp.152-155
    • /
    • 2002
  • In this paper, a new approach is proposed for the error detection dedicated to MPEG-4 video coding by using the digital watermarking. In the process of encoding, the proposed scheme abstracts the macroblock features of headers, motion vectors, and Discrete Cosine Transform (DCT) coefficients, which are embedded in the quantized DCT coefficients as the digital watermarks. The decoder performs the accurate error detection through the watermark extraction. Simulation results demonstrate that the error detection ability of the proposed approach can be significantly enhanced, and that digital watermark embedding incurs little degradation to the picture quality.

  • PDF

An Efficient Array Algorithm for VLSI Implementation of Vector-radix 2-D Fast Discrete Cosine Transform (Vector-radix 2차원 고속 DCT의 VLSI 구현을 위한 효율적인 어레이 알고리듬)

  • 신경욱;전흥우;강용섬
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.12
    • /
    • pp.1970-1982
    • /
    • 1993
  • This paper describes an efficient array algorithm for parallel computation of vector-radix two-dimensional (2-D) fast discrete cosine transform (VR-FCT), and its VLSI implementation. By mapping the 2-D VR-FCT onto a 2-D array of processing elements (PEs), the butterfly structure of the VR-FCT can be efficiently importanted with high concurrency and local communication geometry. The proposed array algorithm features architectural modularity, regularity and locality, so that it is very suitable for VLSI realization. Also, no transposition memory is required, which is invitable in the conventional row-column decomposition approach. It has the time complexity of O(N+Nnzp-log2N) for (N*N) 2-D DCT, where Nnzd is the number of non-zero digits in canonic-signed digit(CSD) code, By adopting the CSD arithmetic in circuit desine, the number of addition is reduced by about 30%, as compared to the 2`s complement arithmetic. The computational accuracy analysis for finite wordlength processing is presented. From simulation result, it is estimated that (8*8) 2-D DCT (with Nnzp=4) can be computed in about 0.88 sec at 50 MHz clock frequency, resulting in the throughput rate of about 72 Mega pixels per second.

  • PDF

Quantized DCT Coefficient Category Address Encryption for JPEG Image

  • Li, Shanshan;Zhang, Yuanyuan
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.4
    • /
    • pp.1790-1806
    • /
    • 2016
  • Digital image encryption is widely used for image data security. JPEG standard compresses image with great performance on reducing file size. Thus, to encrypt an image in JPEG format we should keep the quality of original image and reduced size. This paper proposes a JPEG image encryption scheme based on quantized DC and non-zero AC coefficients inner category scrambling. Instead of coefficient value encryption, the address of coefficient is encrypted to get the address of cipher text. Then 8*8 blocks are shuffled. Chaotic iteration is employed to generate chaotic sequences for address scrambling and block shuffling. Analysis of simulation shows the proposed scheme is resistant to common attacks. Moreover, the proposed method keeps the file size of the encrypted image in an acceptable range compared with the plain text. To enlarge the cipher text possible space and improve the resistance to sophisticated attacks, several additional procedures are further developed. Contrast experiments verify these procedures can refine the proposed scheme and achieve significant improvements.

A Theoretical Model for the Analysis of Residual Motion Artifacts in 4D CT Scans (이론적 모델을 이용한 4DCT에서의 Motion Artifact 분석)

  • Kim, Tae-Ho;Yoon, Jai-Woong;Kang, Seong-Hee;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.3
    • /
    • pp.145-153
    • /
    • 2012
  • In this study, we quantify the residual motion artifact in 4D-CT scan using the dynamic lung phantom which could simulate respiratory target motion and suggest a simple one-dimension theoretical model to explain and characterize the source of motion artifacts in 4DCT scanning. We set-up regular 1D sine motion and adjusted three level of amplitude (10, 20, 30 mm) with fixed period (4s). The 4DCT scans are acquired in helical mode and phase information provided by the belt type respiratory monitoring system. The images were sorted into ten phase bins ranging from 0% to 90%. The reconstructed images were subsequently imported into the Treatment Planning System (CorePLAN, SC&J) for target delineation using a fixed contour window and dimensions of the three targets are measured along the direction of motion. Target dimension of each phase image have same changing trend. The error is minimum at 50% phase in all case (10, 20, 30 mm) and we found that ${\Delta}S$ (target dimension change) of 10, 20 and 30 mm amplitude were 0 (0%), 0.1 (5%), 0.1 (5%) cm respectively compare to the static image of target diameter (2 cm). while the error is maximum at 30% and 80% phase ${\Delta}S$ of 10, 20 and 30 mm amplitude were 0.2 (10%), 0.7 (35%), 0.9 (45%) cm respectively. Based on these result, we try to analysis the residual motion artifact in 4D-CT scan using a simple one-dimension theoretical model and also we developed a simulation program. Our results explain the effect of residual motion on each phase target displacement and also shown that residual motion artifact was affected that the target velocity at each phase. In this study, we focus on provides a more intuitive understanding about the residual motion artifact and try to explain the relationship motion parameters of the scanner, treatment couch and tumor. In conclusion, our results could help to decide the appropriate reconstruction phase and CT parameters which reduce the residual motion artifact in 4DCT.

Efficient Image Upsampling using Frequency Resolution Expansion Schemes in DCT Domain (DCT 도메인에서의 주파수 해상도 화장 기법을 이용한 효과적인 이미지 업샘플링)

  • Park Seung-Wook;Park Ji-Ho;Jeon Byeong-Moon;Park Hyun Wook
    • Journal of Broadcast Engineering
    • /
    • v.10 no.4 s.29
    • /
    • pp.505-514
    • /
    • 2005
  • Image upsampling can be performed in both spatial and frequency (transform) domain. In the spatial domain, various upsampling techniques are developed and 6-tap FIR interpolation filter is most well known method, which is embedded in many video coding standards. It can provide high subjective quality but shows low objective quality. In the transform domain, simple zero padding method can produce upsampled image easily. It shows better objective quality than 6-tap filtering, but it yields ringing effects which annoy eyes. In this paper, we present efficient upsampling method using frequency addition method in transform domain to provide better subjective and objective quality than conventional method Extensive simulation results show that the proposed algorithm produces visually fine images with high PSNR.

Reconstruction of In-beam PET for Carbon therapy with prior-knowledge of carbon beam-track

  • Kim, Kwangdon;Bae, Seungbin;Lee, Kisung;Chung, Yonghyun;An, Sujung;Joung, Jinhun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.6
    • /
    • pp.384-390
    • /
    • 2015
  • There are two main artifacts in reconstructed images from in-beam positron emission tomography (PET). Unlike generic PET, in-beam PET uses the annihilation photons that occur during heavy ion therapy. Therefore, the geometry of in-beam PET is not a full ring, but a partial ring that has one or two openings around the rings in order for the hadrons to arrive at the tumor without prevention of detector blocks. This causes truncation in the projection data due to an absence of detector modules in the openings. The other is a ring artifact caused by the gaps between detector modules also found in generic PET. To sum up, in-beam PET has two kinds of gap: openings for hadrons, and gaps between the modules. We acquired three types of simulation results from a PET system: full-ring, C-ring and dual head. In this study, we aim to compensate for the artifacts that come from the two types of gap. In the case of truncation, we propose a method that uses prior knowledge of the location where annihilations occur, and we applied the discrete-cosine transform (DCT) gap-filling method proposed by Tuna et al. for inter-detector gap.

Novel schemes of CQI Feedback Compression based on Compressive Sensing for Adaptive OFDM Transmission

  • Li, Yongjie;Song, Rongfang
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.5 no.4
    • /
    • pp.703-719
    • /
    • 2011
  • In multi-user wireless communication systems, adaptive modulation and scheduling are promising techniques for increasing the system throughput. However, a mass of wireless recourse will be occupied and spectrum efficiency will be decreased to feedback channel quality indication (CQI) of all users in every subcarrier or chunk for adaptive orthogonal frequency division multiplexing (OFDM) systems. Thus numerous limited feedback schemes are proposed to reduce the system overhead. The recently proposed compressive sensing (CS) theory provides a new framework to jointly measure and compress signals that allows less sampling and storage resources than traditional approaches based on Nyquist sampling. In this paper, we proposed two novel CQI feedback schemes based on general CS and subspace CS, respectively, both of which could be used in a wireless OFDM system. The feedback rate with subspace CS is greatly decreased by exploiting the subspace information of the underlying signal. Simulation results show the effectiveness of the proposed methods, with the same feedback rate, the throughputs with subspace CS outperform the discrete cosine transform (DCT) based method which is usually employed, and the throughputs with general CS outperform DCT when the feedback rate is larger than 0.13 bits/subcarrier.

Watermarking-based Error Concealment in Video Communications

  • Oh Tae-Suk;Kim Yong-Cheol;Adsumilli Chowdary;Mitra Sanjit
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.7C
    • /
    • pp.700-705
    • /
    • 2006
  • In this paper, an informed watermarking algorithm is proposed that aids in concealing packet loss errors in video communications. This watermark-based error concealment (WEC) method embeds a low resolution version of the video frame inside itself as watermark data. At the receiver, the extracted watermark is used as a reference for error concealment. The proposed DCT-based algorithm employs informed watermarking techniques in order to minimize the distortion of host frames. At the encoder, a predictive feedback loop is employed which helps to adjust the strength of the data embedding. Furthermore, the distortion of the DCT coefficients introduced in the embedding can be removed to a considerable extent, by employing bit-sign adaptivity. Simulation results on standard video sequences show that the proposed informed WEC scheme has an advantage of 3$\sim$4 dB in PSNR over non-informed WEC and that even a non-informed WEC is still superior to conventional error concealment techniques.

Pipeline Defects Detection Using MFL Signals and Self Quotient Image (자기 누설 신호와 SQI를 이용한 배관 결함 검출)

  • Kim, Min-Ho;Rho, Yong-Woo;Choi, Doo-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.311-316
    • /
    • 2010
  • Defects positioning of underground gas pipelines using MFL(magnetic flux leakage) inspection which is one of non-destructive evaluation techniques is proposed in this paper. MFL signals acquired from MFL PIG(pipeline inspection gauge) have nonlinearity and distortion caused by various external disturbances. SQI(self quotient image), a compensation technique for nonlinearity and distortion of MFL signal, is used to correct positioning of pipeline defects. Through the experiments using artificial defects carved in the KOGAS pipeline simulation facility, it is found that the performance of proposed defect detection is greatly improved compared to that of the conventional DCT(discrete cosine transform) coefficients based detection.