• Title/Summary/Keyword: 4D visualization

Search Result 299, Processing Time 0.024 seconds

Theoretical Analysis and Experimental Characterization of DoD Metal-Jet System (DoD 메탈젯 시스템의 이론적 해석 및 실험적 분석)

  • Lee, Taik-Min;Kang, Tae-Goo;Yang, Jeong-Soon;Jo, Jeong-Dai;Kim, Kwang-Young;Choi, Byung-Oh;Kim, Dong-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.1 s.256
    • /
    • pp.11-17
    • /
    • 2007
  • In this paper, we present a design, analysis, fabrication and performance test of the novel DoD metal-jet system for application to the high-density and high-temperature-melting materials. The theoretical analysis of the metal-jet nozzle system is derived by using electro-mechanical analogy. Based on the theoretical analysis results, we design the metal-jet print head system and fabricate the metal-jet system, which can eject the droplet of lead-free metal solder in high-temperature. In the experimental test, we set up the test apparatus for visualization of the droplet ejection and measure the ejected droplet volume and velocity. As a result, the diameter, volume and the velocity of the ejected droplet are about 65 $\mu$m $\sim$ 70 $\mu$m, 145p1 $\sim$ 180 pl and 4m/s, which shows quite good agreement with the theoretical analysis results of the 75 $\mu$m-diameter and 220 pl-volume of droplet. In comparison with the experimental result, the errors of diameter and volume are 7% $\sim$ 13% and 18 $\sim$ 34%, respectively.

3-D CT Imaging of Pathological Bone Changes in a Rat Model of Adjuvant-Induced Arthritis

  • Shim, Kyung-Mi;Kim, Se-Eun;Kang, Seong-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.41-46
    • /
    • 2008
  • Computed tomography (CT) is a medical imaging method employing tomography. CT is a 3-Dimensional (3-D) radiographic imaging technique, which is not suited for assessment of inflammation, but can be considered a reference method for assessment of bone damage, due to its direct 3-D visualization of calcified tissue. In this study of pathological joint changes in a rat model of adjuvant-induced arthritis (AIA) and quality analysis of bone destructions were performed by 3-Dimensional computed tomography images. These data demonstrate that the destructive progression of disease in a rat AIA model can be quantified using 3-D CT image analysis, which allows assessment of arthritic disease status and efficacy of experimental therapeutic agents.

  • PDF

Isolation and Identification of Bioactive Compounds from the Tuber of Brassica oleracea var. gongylodes

  • Prajapati, Ritu;Seong, Su Hui;Kim, Hyeung Rak;Jung, Hyun Ah;Choi, Jae Sue
    • Natural Product Sciences
    • /
    • v.26 no.3
    • /
    • pp.214-220
    • /
    • 2020
  • Brassica oleracea var. gongylodes (red kohlrabi) is a biennial herbaceous vegetable whose edible bulbotuber-like stem and leaves are consumed globally. Sliced red kohlrabi tubers were extracted using methanol and the concentrated extract was partitioned successively with dichloromethane (CH2Cl2), ethyl acetate (EtOAc), n-butanol (n-BuOH) and water (H2O). Repeated column chromatography of EtOAc fraction through silica, sephadex LH-20 and RP-18 gel led to isolation of eleven compounds of which compound 1 was a new glycosylated indole alkaloid derivative, 1-methoxyindole 3-carboxylic acid 6-O-β-D-glucopyranoside. Others were known compounds namely, β-sitosterol glucoside (4), 5-hydroxymethyl-2-furaldehyde (5), methyl-1-thio-β-D-glucopyranosyl disulfide (6), 5-hydroxy-2-pyridinemethanol (7), (3S,4R)-2-deoxyribonolactone (8), n-butyl-β-D-fructopyranoside (9), uridine (10) and three fructose derivatives, D-tagatose (11), β-D-fructofuranose (12) and β-D-fructopyranose (13). Similarly, isolation from CH2Cl2 fraction gave two known indole alkaloids, indole 3-acetonitrile (2) and N-methoxyindole 3-acetonitrile (3). The structure elucidation and identification of these compounds were conducted with the help of 13C and 1H NMR, HMBC, HMQC, EIMS, HR-ESIMS and IR spectroscopic data, and TLC plate spots visualization. Compounds 2, 3, 4, 5, 6, 7, 8 and 9 are noted to occur in kohlrabi for the first time. Different bioactivities of these isolated compounds have been reported in literature.

Flow and Heat Transfer Characteristics of a Multi-Tube Inserted Impinging Jet (노즐출구에 삽입된 다중관에 의한 충돌제트의 유동 및 열전달 특성)

  • Hwang, Sang-Dong;Cho, Hyung-Hee
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.2
    • /
    • pp.135-145
    • /
    • 2004
  • An experimental study is conducted to investigate the flow and heat transfer characteristics of a multi-tube inserted impinging jet. Four different multi-tube devices are tested for various nozzle-to-plate distance. Flow visualization by smoke-wire method and velocity measurements using a hot-wire anemometer are applied to analyze the flow characteristics of the multi-tube insert impinging jet. The local heat transfer coefficients of the multi-tube inserted impinging jet on the impingement surface are measured and the results are compared to those of the conventional jet. In multi-tube inserted system the multi-tube length plays an important role in the flow and heat transfer characteristics of the jet flow. With multi-tube insert of I3d4 and I6d4 which has relatively longer tube length than the multi-tube-exit of I3d1 and I6d1, the flow maintains its increased velocity far downstream due to interaction between adjacent flows. For the small H/D of 4, the local heat transfer coefficients of multi-tube inserted impinging jet are much higher than those of the conventional jet because the flow has higher velocity and turbulent intensity by the use of the multi-tube device. At large gap distance of H/D=12, also higher heat transfer rates are obtained by installing multi-tube insert except multi-tube insert of I3d1.

Design and Implementation of 3D Visualization Information System with RFID Tag Data (RFID 태그 데이터를 이용한 3차원 시각화 정보 시스템 설계 및 구현)

  • Ryu, Nam-Hoon;Ban, Kyeong-Jin;Song, Seung-Heon;Kim, Eung-Kon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.2 no.4
    • /
    • pp.203-208
    • /
    • 2007
  • Ministry of Information and Communication is pushing for IT 839 strategy that has main points : 8 major service which can develop IT industry of Korea on the whole, 3 major infra, and 9 major new growth power. Of these, RFID/USN utilizing service is expected to exert a great influence the whole industry from field that is closely related with our life to national defense, supply, construction, transportation, physical distribution, manufacture, circulation, and service. In domestic case, departure of RFID/USN field is a little bit later than advanced nation's, and a technique difference between domestic field and that of advanced nation is about 2 years. In this situation, in order to develop middleware of various field gearing RFID Tag efficiently, we have to study about user interface and data analysis technique that is used in middleware commonly. This paper searches about WPF that appears in user interface field with up-to-date technique, and embodies 3 dimension visualization information system with WPF.

  • PDF

High-resolution magnetic resonance imaging of teeth and periodontal tissues using a microscopy coil

  • Shinya Kotaki;Hiroshi Watanabe;Junichiro Sakamoto;Ami Kuribayashi;Marino Araragi;Hironori Akiyama;Yoshiko Ariji
    • Imaging Science in Dentistry
    • /
    • v.54 no.3
    • /
    • pp.276-282
    • /
    • 2024
  • Purpose: This study aimed to assess the performance of 2-dimensional (2D) imaging with microscopy coils in delineating teeth and periodontal tissues compared with conventional 3-dimensional(3D) imaging on a 3 T magnetic resonance imaging (MRI) unit. Materials and Methods: Twelve healthy participants (4 men and 8 women; mean age: 25.6 years; range: 20-52 years) with no dental symptoms were included. The left mandibular first molars and surrounding periodontal tissues were examined using the following 2 sequences: 2D proton density-weighted (PDw) images and 3D enhanced T1 high-resolution isotropic volume excitation (eTHRIVE) images. Two-dimensional MRI images were taken using a 3 T MRI unit and a 47 mm microscopy coil, while 3D MRI imaging used a 3 T MRI unit and head-neck coil. Oral radiologists assessed dental and periodontal structures using a 4-point Likert scale. Inter- and intra-observer agreement was determined using the weighted kappa coefficient. The Wilcoxon signed-rank test was used to compare 2D-PDw and 3D-eTHRIVE images. Results: Qualitative analysis showed significantly better visualization scores for 2D-PDw imaging than for 3D-eTHRIVE imaging (Wilcoxon signed-rank test). 2D-PDw images provided improved visibility of the tooth, root dental pulp, periodontal ligament, lamina dura, coronal dental pulp, gingiva, and nutrient tract. Inter-observer reliability ranged from moderate agreement to almost perfect agreement, and intra-observer agreement was in a similar range. Conclusion: Two-dimensional-PDw images acquired using a 3 T MRI unit and microscopy coil effectively visualized nearly all aspects of teeth and periodontal tissues.

A Case Study of Developing a Subsurface Information and Visualization System Using ArcView (ArcView를 이용한 지하 정보 및 시각화 시스템 구축 사례 연구)

  • Kim, Hyeon-Gyu;Lee, Doo-Sung
    • Geophysics and Geophysical Exploration
    • /
    • v.4 no.4
    • /
    • pp.101-109
    • /
    • 2001
  • In order to develop a spatial information system that can efficiently manage various subsurface data and produce information in a proper form for a user, we established a database of the well cores and built 3-D shapes that visualize the subsurface objects such as wells, ore bodies, tunnels, and mine cavities. We also made analysis tools available for three-dimensional ore bodies constructed here, such as vertical cross-section generator and mass computing tool. This system was developed by coding Avenue, a scripting language incorporated in ArcView, which is a commercial GIS software. Using the system, it is expected that users can make fast and accurate analysis and interpretation through real-time queries and by contemplating various objects in 3-D perspective.

  • PDF

Optimization of disposable paper-based test strips for hypochlorous acid detection

  • Rita E. Ampiaw;Muhammad Yaqub;Changyeon Woo;Wontae Lee
    • Membrane and Water Treatment
    • /
    • v.14 no.4
    • /
    • pp.181-189
    • /
    • 2023
  • The Covid-19 pandemic has increased demand for chlorine-based sanitizing solutions, most of which contain hypochlorous acid (HOCl) as an active agent. Free chlorine (HOCl) in these sanitizers is crucial for their efficacy. Disposable test strips are affordable and convenient tools for determining various qualitative and quantitative parameters. In this study, disposable opto-chemical test strips were developed by physically immobilizing 3,3',5,5'-tetramethylbenzidine (TMB) and o-dianisidine (o-D) reagents on chromatography and filter paper-based test strips for the visualization and detection of free chlorine in the form of HOCl. The reagents undergo a rapid color change upon reaction with chlorine through a redox reaction. The paper-based test strips showed rapid color change within a minute and a low sample volume requirement (1 ml). This portable, disposable paper-based test strip is a simple and cost-effective way to rapidly detect the presence of HOCl sanitizers for home and field applications. Both TMB and o-D successfully detected chlorine. Chromatography paper proved to be the more efficient option among the two papers used as substrates for the reagents (TMB and o-D). It exhibited high retention capacity and high performance in terms of color transformation when reacting with HOCl, even after two months of storage.

Quantitative Visualization of Mixed Convection in 3-D Rectangular Channels Using TLC Tracers (액정을 이용한 3차원 사각채널 내 혼합대류의 정량적 가시화)

  • Piao, Ri-Long;Kim, Jeong-Soo;Bae, Dae-Seok
    • Journal of Power System Engineering
    • /
    • v.20 no.6
    • /
    • pp.51-57
    • /
    • 2016
  • Experiment is carried out to investigate the mixed convective flow in three-dimensional horizontal rectangular channels filled with high viscous fluid. The particle image velocimetry(PIV) with thermo-sensitive liquid crystal tracers is used for visualizing and analysis. Quantitative data of temperature and velocity are obtained by applying the color-image processing to a visualized image, and neural network is applied to the color-to-temperature calibration. In this study, the fluid used is silicon oil(Pr=909), the aspect ratio(channel width to heigh) is 4 and Reynolds number is $2{\times}10^{-2}$. From the present study, we can visualize the quantitative temperature and velocity of mixed convective flow in three-dimensional horizontal rectangular channels simultaneously.

Heat transfer enhancement in electronic modules using a turbulence promoter (난류촉진체에 의한 전자칩의 열전달촉진에 관한 연구)

  • 박시우;정인기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.6
    • /
    • pp.861-870
    • /
    • 1999
  • An experimental study was carried out to investigate the effects of using various shapes of turbulence promoter on the heat-transfer enhancement of 2-D and 3-D arrays of rectangular modules in a rectangular channel for design of noiseless and low-powered cooling fan in the electronic systems. Measurements of heat/mass transfer coefficients were made using a naphthalene sublimation technique, and the friction factors were measured for Reynolds numbers in the range$3.3{\time}10^3$~$1.6{\time}10^4$. Flow visualization was peformed by oil-film method. It was found that heat transfer and pressure drop increased remarkably due to the existence of the promoter. The results of the performance evaluation based on equal pumping power were showed that substantial heat-transfer enhancement was obtained at low Reynolds number range by use of a turbulence promoter.

  • PDF