• Title/Summary/Keyword: 40 Stairs

Search Result 31, Processing Time 0.025 seconds

The Effects of Multi Joint-Joint Position Sense Training Using Functional Task on Joint Position Sense, Balance, Walking Ability in Patients With Post-Stroke Hemiplegia (기능적 과제를 통한 다관절 관절위치감각 훈련이 뇌졸중 환자의 관절위치감각, 균형, 보행능력에 미치는 효과)

  • Ko, Kyoung-hee;Choi, Jong-duk;Kim, Mi-sun
    • Physical Therapy Korea
    • /
    • v.22 no.3
    • /
    • pp.33-40
    • /
    • 2015
  • The purpose of this study was to investigate the effect of multi joint-joint position sense (MJ-JPS) training on joint position sense, balance, and gait ability in stroke patients. A total of 18 stroke patients participated in the study. The subjects were allocated randomly into two groups: an experimental group and a control group. Participants in the experimental group received MJ-JPS training (10 min) and conventional treatment (20 min), but participants in the control group only received conventional treatment (30 min). Both groups received training for five times per week for six weeks. MJ-JPS is a training method used to increase proprioception in the lower extremities; as such, it is used, to position the lower extremities in a given space. MJ-JPS measurement was captured via video using a Image J program to calculate the error distance. Balance ability was measured using Timed Up and Go (TUG) and the Berg Balance Scale (BBS). Gait ability was measured with a 10 m walking test (10MWT) and by climbing four flights of stairs. The Shapiro-Wilk test was used to assess normalization. Within-group differences were analyzed using the paired t-test. Between-group differences were analyzed using the independent t-test. The experimental group showed a significant decrease in error distance (MJ-JPS) compared to the control group (p<.05). Both groups showed a significant difference in their BBS and 10MWT results (p<.05). The experimental group showed a significant decrease in their TUG and climbing results (p<.05), but the control group results for those two tasks were not found to be significant (p>.05). There was significant difference in MJ-JPS and by climbing four flights of stairs on variation of pre and post test in between groups (p<.05), but TUG and BBS and 10MWT was no significantly (p>.05). We suggest that the MJ-JPS training proposed in this study be used as an intervention to help improve the functional activity of the lower extremities in stroke patients.

Integration Model for Urban Flood Inundation Linked with Underground Space Flood Analysis Model (지하공간 침수해석모형과 연계한 도시침수해석 통합모형)

  • Lee, Chang-Hee;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.4
    • /
    • pp.313-324
    • /
    • 2007
  • An irregular cell-based numerical model was developed to analyze underground space flooding. In this model, the flow characteristics in underground space were computed by link-node system. Also, the model can simulate the underground flood flow related to the influence of stairs and wall-structures. Empirical discharge formula were introduced to analyze weir-type flow for shopping mall, and channel-type flow for subway railroad respectively. The simulated results matched in reasonable range compared with the observed depth. The dual-drainage inundation analysis model and the underground space flood analysis model were integrated using visual basic application of ArcGIS system. The developed model can help the decision support system of flood control authority for redesigning and constructing flood prevention structures and making the potential inundation zone, and establishing flood-mitigation measures.

A Study on the Indoor Evacuation Using Matsim (활동기반 교통모형 MATSim을 이용한 실내 피난 분석)

  • Kim, Joo young;Lee, Seung jae;Ahn, Chi won
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.17 no.2
    • /
    • pp.18-31
    • /
    • 2018
  • It is important to conduct various analyzes to evacuate occupants in advance, because the disaster can cause serious injury. Therefore, it is necessary to analyze all the predictable scenarios that may occur. In this study, we propose a method to analyze the evacuation of indoor disaster using activity - based transport model MATSim. We have developed the university building as target area and simulated about 5,000 occupants. The analysis scenarios are set as basic evacuation conditions, exit closures and emergency stair closures. As a result of analysis of each scenario, the evacuation time was analyzed to be about 5:40(340s) in the base scenario, increased by 15% in the scenario 2 and increased by 23% in scenario 3. As a result of this study, we suggest that it is important to manage illegal obstacles of emergency stairs for rapid evacuation. Therefore, this study can contribute to the effective disaster prevention strategy of the building.

Analysis of Causes of Casualties in Jecheon Sports Center Fire - Focus on Structural Factors of Building and Equipment - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 - 건물과 설비의 구조적인 요인을 중심으로 -)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.86-94
    • /
    • 2018
  • A sports center fire in Jecheon caused 29 deaths and 40 injuries. This study focused only on the structural factors of the building and equipment to investigate the causes of casualties based on the fire investigation results at the sports center. The structural factors of the building and equipment were a piloti-type parking lot, lack of a fire compartment between the piloti-type parking lot and lobby, lack of an installed sprinkler system, lack of an installed fire door in the main stairs on the $1^{st}$ floor, lack of an installed fire water tank on the rooftop, an installed pocket fire door in the main entrance on the $2^{nd}$ floor, poor fire compartments in an EPS space and a pipe pit and on each floor, a leak in the joint of a drain pipe, plywood installed in the hoistway of the freight elevator and interior wall, illegal remodeling of a closed rooftop structure, which cannot discharge smoke and heat, installed styrofoam insulation in the inside of the parking lot ceiling, an installed tempered glass window, which cannot be opened in the ladies bathroom on the $2^{nd}$ floor, and a finished dryvit exterior wall.

Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management - (제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로-)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.57-66
    • /
    • 2018
  • A sports center fire in Jecheon that caused 29 deaths and 40 injuries was analyzed based on initial response and management in order to investigate the causes of the casualties. The aspects of initial response included delay of reporting 119, not being guided to the exit for the body scrubber on the $2^{nd}$ floor for escape, opening the fire doors of the exits on the $1^{st}$ floor and $3^{rd}$ floor, not closing the fire door of the main stairs on the $3^{rd}$ floor, and not doing an emergency broadcast. The management aspects included closing the alarm valve of the sprinkler system on the $1^{st}$ floor, starting-stop of the fire pump controller, neglecting leakage of water and electricity between the false ceiling and ceiling in the parking lot, hiding the exit light in the ladies bathroom lounge on the $2^{nd}$ floor and piling up things in the exit, neglecting the button of an automatic door on the $2^{nd}$ floor, conventional fire safety management, insufficient inspection of fire equipment, and not working fire shutters and smoke exhaust windows.

Current Situation and Characteristics of Owner Shop Houses in the Historic Area - Focused on Seongan-dong and Jungang-dong, Cheongju, Korea - (역사적 도심 내 자가(自家) 병용주택의 현황 및 유형별 특성 - 청주시 성안동과 중앙동을 대상으로 -)

  • Yoo, Seul Gi;Jung, Jin Ju;Kim, Tai Young
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.26 no.2
    • /
    • pp.35-40
    • /
    • 2024
  • This study examines the classification and typical characteristics of 148 owner shop houses existing in the historical city center of Cheongju. First, they can be classified into single-story, middle-story, and divided types according to the distribution of residential and commercial functions. The single-story(36) has 'ㅡ', 'ㄱ', and 'narrow and deep'-shaped arrangement, with stores on the front and houses on the rear. The middle-story second floor(89) is divided into a first-story store and a second-story house, and the third floor(23) has different functions for each floor, but more than half of them have houses on the second and third floors. Among the total, there are also 16 cases in which the division type is taken with different construction times and structures. Second, in the position of the stairs connected to the upper floor among the middle-floor types(112), the outer stair type(52) to separate from the living space while making the most of the stores on the first floor accounts for 47%, but the biggest feature is that the inner staircase type(34) with privacy reaches 30%. The rear stair room type(26) entering through alleyways or private yards is also 23%. Third, the front pillar spacing varies from 1bay to 4bay in appearance, but the 2bay type on the 2nd floor and the 1bay type on the 3rd floor occupy the largest proportion. This exterior type is a characteristic of a owner shop house that can measure the range of personal ownership. Despite the conflicting functions of stores and houses, 35~40% of the cases are in which the opening positions of the upper and lower floors are unified.

A Study on Fall Accident (1개 종합병원 환자의 낙상에 관한 조사)

  • Lee, Hyeon-Suk;Kim, Mae-Ja
    • The Korean Nurse
    • /
    • v.36 no.5
    • /
    • pp.45-62
    • /
    • 1998
  • The study was conducted from November 1995 to May 1996 at the one general hospital in Seoul. The total subjects of this study were 412 patients who have the experience of fall accident, among them 31 was who have fallen during hospitalization and 381 was who visited emergency room and out patient clinic. The purposes of this study were to determine the characteristics, risk factors and results of fall accident and to suggest the nursing strategies for prevention of fall. Data were collected by reviewing the medical records and interviewing with the fallers and their family members. For data analysis, spss/pc+ program was utilized for descriptive statistics, adjusted standardized $X^2$-test. The results of this study were as follows: 1) Total subjects were 412 fallers, of which 245(59.5%) were men and 167(40.5%) were women. Age were 0-14 years 79(19.2%), 15-44 years 125(30.4%), 45-64 years 104(25.2%), over 65 years 104(25.2%). 2) There was significant association between age and the sexes ($X^2$=39.17, P=0.00). 3) There was significant association between age and history of falls ($X^2$=44.41. P= .00). And history of falls in the elderly was significantly associated with falls. 4) There was significant association with age and medical diagnosis ($X^2$=140.66, P= .00), chief medical diagnosis were hypertension(34), diabetis mellitus(22), arthritis(11), stroke(8), fracture(7), pulmonary tuberculosis(6), dementia(5) and cataract(5), 5) There was significant association between age and intrinsic factors: cognitive impairment, mobility impairment, insomnia, emotional problems, urinary difficulty, visual impairments, hearing impairments, use of drugs (sedatives , antihypertensive drugs, diuretics, antidepressants) (P < 0.05). But there was no significant association between age and dizziness ($X^2$=2.87, P=.41). 6) 15.3% of total fallers were drunken state when they were fallen. 7) Environmental factors of fall accident were unusual posture (50.9%), slips(35.2%), trips (9.5%) and collision(4.4%). 8) Most of falls occurred during the day time, peak frequencies of falls occurred from 1pm to 6pm and 7am to 12am. 9) The places of fall accident were roads(22.6%), house-stairs 06.7%), rooms, floors, kitchen (11.2%), the roof-top, veranda, windows(10.9%), hospital(7.5%), ice or snowy ways(5.8%), bathroom(4.9%), playground, park(4.9%), subway-stairs(4.4%) and public-bathrooms (2.2%). 10) Activities at the time of fall accident were walking(37.6%), turning around or reaching for something(20.9%), going up or down stairs09.2%), exereise, working07.4%), up or down from a bed(2.7%), using wheelchair or walking aids, standing up or down from a chair(2.2%) and standing still(2.2%). 11) Anatomical locations of injuries by falls were head, face, neck(31.3%), lower extremities (29.9%). upper extremities(20.6%), spine, thorax, abdomen or pelvic contents(l1.4%) and unspecified(2.9%). 12) Types of injures were fracture(47.6%), bruises03.8%), laceration (13.3%), sprains(9.0%), headache(6.6%), abrasions(2.9%), intracranial hemorrage(2.4%) and burns(0.5%). 13) 41.5% of the fallers were hospitalized and average of hospitalization was 22.3 days. 14) The six fallers(1.46%) died from fall injuries. The two fallers died from intracranial hemorrage and the four fallers died of secondary infection; pneumonia(2), sepsis(1) and cell lulitis(1). It is suggested that 1) Further study is needed with larger sample size to identify the fall risk factors. 2) After the fall accident, comprehensive nursing care and regular physical exercise should be emphasized for the elderly person. 3) Safety education and safety facilities of the public place and home is necessary for fall prevention.

  • PDF

The Study on Fire Phenomena in The Deeply Underground Subway Station (대심도 지하역사에서의 화재현상 연구)

  • Jang, Yong-Jun;Kim, Hag-Beom;Lee, Chang-Hyun;Jung, Woo-Sung
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1773-1780
    • /
    • 2008
  • When the fire occur in the deeply underground subway station, the difficulties of passenger evacuation are expected because of many stairs to the exit. In this study, SOONGSIL-University station (7 line, 47m depth) is the one of the deepest subway stations of the each line in the Seoul metro. The numerical computational-simulation was performed for the fire driven flow in the subway station. Hot and smoke flow was analyzed from the simulation results. The proper plan of evacuation against fire was considered through the results. The fire driven flow was simulated using FDS code in which LES method was applied. The Heat Release Rate was 10MW and the ultrafast model was applied for the growing model of the fire source. The proper mesh size was determined from the characteristic length of fire size. The parallel computational method was employed to compute the flow and heat eqn's in the meshes, which are about 10,000,000, with 6cpu of the linux clustering machine.

  • PDF

Present Condition of Indoor Noise Level in One-Room Type Multi-Family Housings around Campus (대학주변 원룸형 다가구주택의 실내소음수준 실태)

  • Choi Yoon-Jung
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.3 s.50
    • /
    • pp.191-198
    • /
    • 2005
  • The present study is a preliminary research improving the dwelling quality of one-room type multi-family housings around the university campus. The purpose of the study is to investigate the present condition of Indoor noise level using · residents' responses and field measurements. The respondents are 104 residents living in one-room type multi-family housings. The field measurements on equivalent noise level of indoor and outdoor were carried out in 6 subject house units during the $26th\~28th$ of November 2002. The results are as follows. 1) The residents show relatively non-positive responses at evening and night on the present condition of indoor noise. 2) They answer 'living equipment foise' and 'water hammer' as major types of indoor noise of house unit. 3) Outdoor noise levels, basic factor of noise environment in 6 subject buildings were distributed $52.8\~65.3dB(A)Leq_{5min}$ and were inappropriate to the standard for environmental noise, $55 dB(A)Leq_{5min}$. 4) Indoor noise levels of subject house units were measured as $27.5\~63.5dB(A)Leq_{5min}$, the average of each house unit except one house unit was higher than the level feeling as noise, 40dB(A). 5) It was found that the differences of indoor noise levels between subject house units were caused by 'residents' living noise', 'living equipment noise', 'water hammer', and 'walking and talking noise in stairs and corridors'. 6) Therefore, it is required to plan for improving the quality of noise environment in one-room type multi-family housing around the campus. For example, soundproof construction (including double window with pair glass and balcony), outdoor garden with trees and water for increasing natural sound, interior materials with sound absorbing power to absorb living noise, soundproof pipe or double surface pipe for decreasing 'water hammer', and noiseproof floors, etc. are required.

A Study on the Attention Concentration Properties in Convergent Exploration Situations in Cafe Space - Focusing on Gaze and Brain wave Data Analysis - (카페공간에 대한 수렴적 탐색상황에서의 주의집중 특성의 분석 방법에 관한 연구 - 선택적 주시데이터에 의한 뇌파 데이터 분석을 중심으로 -)

  • Kim, Jong-Ha;Kim, Ju-Yeon;Kim, Sang-Hee
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.2
    • /
    • pp.30-40
    • /
    • 2016
  • This study analyzed the attention concentration tendencies of one(1) subject who showed convergent exploratory acts actively through the gaze-brainwave measurement experiment of cafe space images and our research findings are as follows. First, the areas of interest (AOIs) that the subject gazed visually by paying attention to it and concentrating on it at a cafe space include counter&menu area, sign area, partition area, image wall area, stairs area, and movable furniture area, and built-in furniture area: seven areas in total. Second, conscious gaze frequency appeared the highest in counter&menu area, and conscious gaze appeared more later than in initial times. Third, conscious gaze pattern was divided into the zone that explored various areas dispersely (distributed exploratory zone) and the zone that explored between particular areas concentratedly (intensive exploratory zone). Fourth, as a result of analyzing the brainwave attention concentration, it was found that the attention concentration in prefrontal lobe (Fp1, Fp2) and frontal lobe (F3, F4) rose to a higher level in the zone of 15 to 16 seconds and this time zone was considered to be a zone where gazing at counter&menu area was very active. In addition, the attention concentration appeared higher in the initial zone than in the later zone, among the entire experimental time zones. Finally, as a result of analyzing the changes in activation by brain portion of the SMR wave expressed when maintaining the arousal and attention concentration, it was found that the right prefrontal lobe and the frontal lobe became activated in the time zone when the intensive exploration of "counter&menu area" and "movable furniture${\leftrightarrow}$built-in furniture area" had occurred and the time zone when the intensive exploration of "image wall${\leftrightarrow}$partition area" and "counter&menu${\leftrightarrow}$sign area" had occurred.