• Title/Summary/Keyword: 4.3 Incident

Search Result 389, Processing Time 0.025 seconds

Energy Loss of Hydrogen Atom due to Charge Exchange in Neutral Particle Energy Analyzer (중성입자 에너지 분석장치에서 전하교환용 탄소박막에 의한 수소원자의 에너지 손실특성)

  • Kim, Kye-Ryung;Kim, Wan;Lee, Yong-Hyun;Kang, Hee-Dong
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.3
    • /
    • pp.179-187
    • /
    • 1998
  • A neutral particle energy analyzer, which has the carbon stripping foil and the $90^{\circ}$ cylindrical electrostatic deflection plate, was designed and constructed for measuring of ion temperature in plasma. The energy calibration and energy resolution were studied in detail for a hydrogen ion at the $0.5{\sim}3.0\;keV$ energy using a duoplasmatron ion source. An energy of hydrogen ion to the deflection plate voltage at the peak ion count rate could be fitted by the expression $E_{o}(keV)$=3.83V(kV). The measured energy resolution, which was about 2 % at the energy of 3.0 keV and 9 % at the energy of 0.5keV, was better for the increased hydrogen ion energy. For the charge exchanged hydrogen atom due to the carbon stripping foil, the energy calibration, energy loss and resolution were measured to the $0.5{\sim}2.0{\mu}g/cm^{2}$ thickness of the carbon stripping foil. An energy of the charge exchanged hydrogen atom as a function of the deflection plate voltage and carbon foil thickness could be fitted by the expression $E_{o}(keV)=(0.53d+4.4){\cdot}V(kV)$. The energy loss was $0.23{\sim}0.89\;keV $ to the $0.5{\sim}2.0{\mu}g/cm^{2}$ carbon foil thickness and the $0.5{\sim}3.0\;keV$ energy of the incident neutral hydrogen atom, it could be fitted by the expression ${\Delta}E=(0.12d+0.27){\cdot}{E_{o}}^{1/2}(keV)$. The measured energy resolution for the neutral hydrogen atom, which was between 7 % and 35 % in this experiment region, was increased for the increasing neutral hydrogen atom energy and the decreasing carbon stripping foil thickness.

  • PDF

Characteristics of Beach Change and Sediment Transport by Field Survey in Sinji-Myeongsasimni Beach (신지명사십리 해수욕장에서 현장조사에 의한 해빈변화와 퇴적물이동 특성)

  • Jeong, Seung Myong;Park, Il Heum
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.5
    • /
    • pp.594-604
    • /
    • 2021
  • To evaluate the causes of beach erosion in Sinji-Myeongsasimni Beach, external forces, such as tides, tidal currents, and waves, were observed seasonally from March 2019 to March 2020, and the surface sediments were analyzed for this period. In addition, the shoreline positions and beach elevations were regularly surveyed with a VRS GPS and fixed-wing drone. From these field data, the speed of the tidal currents was noted to be insufficient, but the waves were observed to af ect the deformation of the beach. As the beach is open to the southern direction, waves of heights over 1 m were received in the S-SE direction during the spring, summer, and fall seasons. Large waves with heights over 2 m were observed during typhoons in summer and fall. Because of the absence of typhoons for the previous two years from July 2018, the beach area over datum level (DL) as of July 2018 was greater by 30,138m2 compared with that of March 2019, and the beach area as of March 2020 decreased by 61,210m2 compared with that of March 2019 because of four typhoon attacks after July 2018. The beach volume as of March 2019 decreased by 5.4% compared with that of July 2018 owing to two typhoons, and the beach volume as of September 2019 decreased by 7.3% because of two typhoons during the observation year. However, the volume recovered slightly by about 3% during fall and winter, when there were no high waves. According to the sediment transport vectors by GSTA, the sediments were weakly influxed from small streams located at the center of the beach; the movement vectors were not noticeable at the west beach site, but the westward sediment transport under the water and seaward vectors from the foreshore beach were prominently observed at the east beach site. These patterns of westward sediment vectors could be explained by the angle between the annual mean incident wave direction and beach opening direction. This angle was inclined 24° counterclockwise with the west-east direction. Therefore, the westward wave-induced currents developed strongly during the large-wave seasons. Hence, the sand content is high in the west-side beach but the east-side beach has been eroded seriously, where the pebbles are exposed and sand dune has decreased because of the lack of sand sources except for the soiled dunes. Therefore, it is proposed that efforts for creating new sediment sources, such as beach nourishment and reducing wave heights via submerged breakwaters, be undertaken for the eastside of the beach.

Development of a Thermoplastic Oral Compensator for Improving Dose Uniformity in Radiation Therapy for Head and Neck Cancer (두경부암 방사선치료 시 선량 균일도 향상을 위한 Thermoplastic 구강 보상체의 개발)

  • Choi, Joon-Yong;Won, Young-Jin;Park, Ji-Yeon;Kim, Jong-Won;Moon, Bong-Ki;Yoon, Hyong-Geun;Moon, Soo-Ho;Jeon, Jong-Byeong;Suh, Tae-Suk
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.269-278
    • /
    • 2012
  • Aquaplast Thermoplastic (AT) is a tissue-equivalent oral compensator that has been developed to improve dose uniformity at the common boundary and around the treated area during radiotherapy in patients with head and neck cancer. In order to assess the usefulness of AT, the degree of improvement in dose distribution and physical properties were compared to those of oral compensators made using paraffin, alginate, and putty, which are materials conventionally used in dental imprinting. To assess the physical properties, strength evaluations (compression and drop evaluations) and natural deformation evaluations (volume change over time) were performed; a Gafchromic EBT2 film and a glass dosimeter inserted into a developed phantom for dose verification were used to measure the common boundary dose and the beam profile to assess the dose delivery. When the natural deformation of the oral compensators was assessed over a two-month period, alginate exhibited a maximum of 80% change in volume from moisture evaporation, while the remaining tissue-equivalent properties, including those of AT, showed a change in volume that was less than 3%. In a free-fall test at a height of 1.5 m (repeated 5 times as a strength evaluation), paraffin was easily damaged by the impact, but AT exhibited no damage from the fall. In compressive strength testing, AT was not destroyed even at 8 times the force needed for paraffin. In dose verification using a glass dosimeter, the results showed that in a single test, the tissue-equivalent (about 80 Hounsfield Units [HU]) AT delivered about 4.9% lower surface dose in terms of delivery of an output coefficient (monitor unit), which was 4% lower than putty and exhibited a value of about 1,000 HU or higher during a dose delivery of the same formulation. In addition, when the incident direction of the beam was used as a reference, the uniformity of the dose, as assessed from the beam profile at the boundary after passing through the oral compensators, was 11.41, 3.98, and 4.30 for air, AT, and putty, respectively. The AT oral compensator had a higher strength and lower probability of material transformation than the oral compensators conventionally used as a tissue-equivalent material, and a uniform dose distribution was successfully formed at the boundary and surrounding area including the mouth. It was also possible to deliver a uniformly formulated dose and reduce the skin dose delivery.

Analysis of the Factors influencing the performance of Cardiopulmonary Resuscitation (심폐소생술 수행에 영향을 미치는 요인 분석)

  • Choi, Keun-Myung
    • The Korean Journal of Emergency Medical Services
    • /
    • v.9 no.2
    • /
    • pp.55-78
    • /
    • 2005
  • The purpose of this study was to provide basic data for the improvement of the guidelines and training programs regarding the cardiopulmonary resuscitation performance of bystanders who can respond to the incidents in earlier times as the first responder of the cardiac arrest incident, by reviewing the performance of basic CPR and the influencing factors after providing 70 students of Department of Emergency Medical Technology with the CPR training. For the purpose of the study, the collected data were computerized and analyzed by SPSS-WIN program(ver. 10.1). The results for this study were as follows The duration of session between the groups in the BLS CPR were 3 minutes and 36 seconds, 2 minutes and 32 seconds respectively. The average compression number per minute were 24.3 times and 33,2 times respectively(p=.000), and the average compression rate per minute were 112 times and 122 times respectively(p=.000). The average ventilation number per minute were 3.54 times and 5.1 times respectively(p=.000). The errors in compression "Too shallow" were 20.73 times(34.6%) and 23,23 times(38,7%) out of 60 times in 4 cycles with the standard of 38 nun. In CPR performance results according to gender in the first episode, males showed better results in compression depth as 41.5 mm comparing to females average 38.2 mm(p=.015). When ventilation results were compared according to the use of FS, the average ventilation number per minute, total ventilation per minute and the average volume per episode were significantly higher when FS was not used(<.040), There was no significant difference in ventilation accuracy between two groups. According to the results, we need to improve and distribute portable barrier devices, and to be familiar with those devices. We need to enforce ventilations as well as to include compressions so that faster and more accurate CPR can be performed. Additionally, we need to exclude ventilation only cases, minimize the interference time of chest compression due to inaccurate ventilation, simplify or minimize the complicatedness of CPR performance and responding time related to breathing, provide first responders with various training programs such as initial assessment and ventilations only, or initial assessment and chest compression-only CPR and than provide advanced training with AHA BLS education including CPR for more than two people according to CPR skills and target characteristics.

  • PDF

A Study on the Attenuation of Surface Acoustic Waves by Optical Measurement Method (광학적 측정방법에 의한 표면 탄성파의 감쇠에 관한 연구)

  • You, I.H.;Kim, D.I.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.4
    • /
    • pp.237-243
    • /
    • 1995
  • We have studied methods of detecting attenuation of solid materials such as silicon wafer and piezoelectric $LiTaO_3$ by means of optical probing techniques. We have performed measurements of surface acoustic waves(SAW) generated from 90 degree wedge type transducer and also from inter-digital transducers(IDT). SAW of 20.0 MHz was generated on a silicon wafer from the 90 degree wedge type transducer and those of 20.8 and 14.5 MHz are generated on a $LiTaO_3$ from the IDT. Then any surface-corrugation resulted from the above SAW was investigated by He-Ne laser beams. We projected laser beams, which were modulated by an optical chopper, on the SAW of the same frequency and then measured the scattered beam by the lock-in amplifier. We modulated and synchronized both SAW and the incident laser beam as well as the phase sensitive detector(PSD) to the same frequency in order to simplify our measurement system. We obtained the attenuation coefficients of SAW to be $0.62{\sim}0.75dB/mm$(from IDT1, 20.8 MHz), and $0.60{\sim}0.72dB/mm$(from IDT2, 14.5 MHz), $0.83{\sim}1.28dB/mm$(from the wedge type), respectively.

  • PDF

The Study of Appropriate X-ray Tube Angle for the Anterior-posterior Chest Radiography Using S-align Function (S-align 기능을 이용한 흉부 전·후 방향 검사 시 적절한 X선관 각도에 관한 연구)

  • Park, Myeong-Ju;Joo, Young-Cheol;Kim, Min-Suk;Yuk, Jeong-Won;Kim, Han-Yong;Kim, Dong-Hwan
    • Journal of radiological science and technology
    • /
    • v.45 no.4
    • /
    • pp.299-304
    • /
    • 2022
  • This study uses the 'S-align' function to present a reference value of the X-ray tube angle for the realization of an image similar to that of the chest PA image during chest AP radiography. This study targeted dummy phantom and used a 17"×17" DR image receptor. The irradiation conditions were 110 kVp, 160 mA, 50 ms, and the distance between the central X-ray and the image receptor was set to 180 cm and 110 cm, respectively. The end of the catheter was placed at the 11th thoracic height to indicate the nasogastric tube. In the case of lung apex length measurement, the mean value of measurement was 30.53±0.47 in PA. T 0°, TCA 5~25°, TCE 5~15° were 21.07±0.29, 27.60±0.21, 34.13±0.44, 39.86±0.31, 45.96±0.61 mm, 54.13±0.37 mm, 16.16±0.46 mm, 9.81±0.35 mm, 2.75±0.30 mm, respectively. For the depth of the catheter end, the average value measured at PA was 6.70±0.31 mm. T 0°, TCA 5~25°, TCE 5~15° were 15.72±0.38 mm, 24.10±0.50 mm, 29.24±0.86 mm, 34.35±0.35 mm, 41.06±1.08 mm, 48.07±0.38 mm, 12.85±0.25 mm, 7.92±0.36 mm, 3.01±0.39 mm, respectively. The length of the lung apex was similar to that of chest PA when the angle of incidence was adjusted from 5° to 10° in the leg direction, and the depth of the catheter tip was most similar when the X-ray tube angle was incident at 10° in the head direction. Therefore, To change the X-ray tube angle according to the purpose of the examination during the chest AP radiography using 'S-align' function is considered necessary.

Study on Rainfall Interception Loss from Canopy in Forest(I) (삼림(森林)에서 임관(林冠)에 의한 강우차단(降雨遮斷) 손실(損失)에 관(關)한 연구(硏究)(I))

  • Kim, Kyong Ha;Woo, Bo Myeong
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.3
    • /
    • pp.331-337
    • /
    • 1988
  • To investigate the effects of forest stand and stony characteristics on interception loss from canopy trees, throughfall and stemflow under the canopy of a pine stand and a hardwood stand were measured during 4-month periods July to October, 1986 at the Kwanak Arboretum near Anyang, and the data were analysed by correlation and regression methods. The man results obtained from this study are summerized as follows : 1. The overall throughfall collected during measurement period were 593.5mm(76.7%) in the pine stand and 663.1mm(81.8%) in the hardwood stand oui of total percipitation of 773.8mm. Combined regression analysis describes the relation between total precipitation(P) and throughfall(T) in the pine stand as T=-1.8675+0.8320 P. in the hardwood stand as T=-8179+0.8805P. 2. And the sum of stemflow from measurement of total precipitation in the pine stand and the hardwood stand were 37.4mm(4.8%) and 15.5mm(2%), respectively. In total precipitation less than 2.5mm, stemflow were not measured in both the pine stand and the hardwood stand. Regression equations for the pine stand and the hardwood stand are S=-0.6155+0.0698P, S=-0.0497+0.0183P. The mean slope and intercept of the individual regression of stemflow on rainfall for each fewest stand indicate the proportion of the rain diverted to the trunks and trunk water capacity, respectively. 3. Interception loss accounted for 142.9mm(18.5%) in the pine stand and 125.2mm(16.2%), in the hardwood stand. 4. By quadratic predictive model of relation between interception loss and total incident rainfall, the extent of variance in interception loss explained was about 72% and 61% in the pine stand and the hardwood stand respectively.

  • PDF

A Study on the Agenda Rank-Order Correlation between Twitter and Portal News about Sewol Ferry Catastrophe (세월호 참사에 대한 트위터와 포털뉴스의 의제 순위 상관관계 연구)

  • Kim, Shin-Ku;Choi, Eun-Kyoung
    • Journal of Internet Computing and Services
    • /
    • v.16 no.3
    • /
    • pp.105-116
    • /
    • 2015
  • The Sewol ferry catastrophe that took place on April 16 2014 was unprecedented in terms of its sociopolitical implications, which had reverberated throughout the Korean nation. Mindful of such distinct characteristics of the Sewol ferry catastrophe, this thesis looks into the salience of the agendas portrayed in Twitter and Portal News coverage on the disaster and the correlation between the attribute-specific agendas of the foregoing mediums by making use of the agenda rank order correlation method. Extraction and analysis of big data revealed that first, while the hypothesis that there were little difference in terms of salience among the main agendas between Twitter and Portal News was dismissed, the rank order correlation proved to be high as regards the main agendas on Twitter and Portal News. This signifies that Twitter agendas exert influence over those on Portal News. Next, and regarding the five main agendas on the incident, there existed differences in salience between the attribute-specific agendas of the two mediums, with low figures for corresponding rank order correlations. Such results signify that Twitter and Portal News have little influence over each other as regards their agenda rank order correlation.

The Effects of Education on Knowledge and Confidence in Postpartal Self-care and New baby care (산모교육의 효과 측정 - 산욕기 자가간호와 신생아양육에 대한 지시와 자신감을 중심으로-)

  • Kwang, Youn-Hee;Lee, Mi-La
    • Women's Health Nursing
    • /
    • v.2 no.2
    • /
    • pp.284-297
    • /
    • 1996
  • A maternity ward in a hospital in Seoul has an educational program for postpartal mothers since its opening, but evaluation on the program has not been done. This study was to find whether the educational program contributed to increase of knowledge and confidence of the post-partal mothers in the area of postpartal self-care and the newborn baby care or not. This study aimed at improvement of the educational program for posrpartal mothers and the newborn babies. Subjects were 40 primiparae who were admitted to the obstetric ward in a general hospitals in Seoul from August 20th to September 10th, 1995. Subjects were those who had no labor pain at the admission time, had no complications during labor and delivery, gave a birth to a healthy baby, and agreed to participate in this study. All subjects were well educated and were in well-to-do group. Most of them received antenatal care adequately. They were tested on knowledge and self-confidence in the area of postpartal self-care and infant care two times, one at the admission time and the other prior to discharge. After the first test, nurses in a maternity ward and nursery taught them on postpartal self-care and infant care. Education consisted of a 1 hour planned program and incident teachings done at bed side. Four tools were developed by authors based literature review. The test tool for knowledge of postpartal self-care consisted of 15 items which included the definition of postpartum, dangerous symptoms in postpartum, lochia, time to begin coitus, postpartum exercise, sitz-bath, and perineal care. The test tool for self-confidence in postpartal self-care included such items as emergency care on dangerous symptoms in postpartum, sexual life and contraception after postpartum, self-confidence in postpartum exercise and perineal care. The test tool for knowledge of newborn baby care consisted of 18 items which included bathing, umbilical cord care, vaccination, breast feeding, abnormal symptoms of neonate. The test tool for self confidence in the newborn baby care included umbilical cord care, vaccination, breast feeding, emergency care for baby. Analysis of demographic data were analyzed with calculation of percentage. Score differences between the first test and the second test were analyzed with paired t-test. SAS / PC (Release 6.04 for DOS) program are as follows. 1. Mothers' knowledge of postpartal self-care increased significantly after education (t=10.04, df=38, p=0.0001). 2. Mothers' self-confidence in postpartal self-care increased significantly after education (t=6.53, df=38, p=0.0001). 3. Mother's knowledge of the newborn abay care increased significantly after education (t=9.74, df=38, p=0.0001). 4. Mothers' self-confidence in the newborn baby care increased significantly after education(t=8.22, df=38, p=0.0001) Suggestions for further studies and nursing practice were as follows. 1. We suggest studies by randomized control-group pretest-posttest design or nonequivalent control group pretest-posttest design will be done. 2. We suggest follow-up studies to find if mothers's confidence will last or not after discharge. 3. We suggest general hospitals to establish a phone-counseling system.

  • PDF

Breast Cancer Detection Rate, Incidence, Prevalence and Interval Cancer-related Mammography Screening Times among Thai Women

  • Sripaiboonkij, Nintita;Thinkamrop, Bandit;Promthet, Supannee;Kannawat, Chalermdej;Tangcharoensathien, Voranuj;Ansusing, Tamnit;Rattanamongkolgul, Suthee
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4137-4141
    • /
    • 2016
  • Background: A recent guideline by the American Cancer Society recommended that mammography (MMG) should be done for women starting in their mid-40s. In Thailand, information on opportunistic mammography screening is limited and data on the total incidence of breast cancer are also lacking. The purpose of this study was to estimate the breast cancer detection, incident and prevalence rates among Thai women. Materials and Methods: We retrospectively reviewed the opportunistic mammography screening of normal women between 30 and 80 years who underwent the procedure between 2001 and 2010. All cases were followed until 2012. The detection rate was calculated for the whole period of observation using 'number of women with positive findings' divided by 'total number of women screened'. The incidence rate was calculated only at the first MMG while the subsequence rate was calculated based on all new cases detected at each subsequent MMG. Results: Among the 47,430 women, there were 152,091 MMGs or approximately 3.2 occasions per person (range, 1-10). The average duration of the interval between each subsequence visit was 1.8 years. Overall, breast cancer was detected in 543 women, with a detection rate of 10.3 per 1,000 persons. The prevalence rate of breast cancer at the first visit was 5.78 per 1,000 persons. The incidence or new cases detected at any follow-up visit was 10.4 per 1,000 persons. The overall interval cancer was 0.91 per 1,000 women, mainly detected before their second and third MMG, with a rate of 0.0.47 and 0.76 per 1,000 women. Conclusions: Opportunistic mammography screening in Thailand detected 10 case of breast cancer from each 1,000 women. This paper indicated a high rate of cancer detection during a two year interval, hence, a screening mammogram should be performed more often.