• Title/Summary/Keyword: 4 probe measurement

Search Result 310, Processing Time 0.035 seconds

Retrieval of Soil Moisture Using Microwave Reflection at the End of a Coaxial Probe (동축선 끝단에서의 마이크로파 반사를 이용한 토양 수분 함유량 산출 기술)

  • 김태진;오이석
    • Korean Journal of Remote Sensing
    • /
    • v.13 no.2
    • /
    • pp.151-163
    • /
    • 1997
  • In this paper, an algorithm for retrieving soil moisture from measurement of microwave reflection at the end of a coaxial canble is presented. Because the wave reflection from the boundary between air and soil layers depends on the dielectric constant of the soil layer, the dielectric constant can be obtained from measured reflection coefficient. At first, an equivalent circuit for the coaxial probe contaced on the soil surface was chosen with two unknown circuit elements. Then, the unknown circuit elements are obtained experrmentally by measuring the reflection constants of 20 soil samples, and consequently, an empirical formula for computing the dielectric constant from the reflection coefficient is obtained. The dielectric constant is mainly influenced by the soil moisture, and the soil moisture can be computed from the dielecfic constant using an existing empirical formula. HP Network Analyzer 8510C was used to measure the magnitude and the phase of the reflection coeffcient at 4.65 GHz, and the measured data set were used to obtain an empirical formula for computing the dielectric constant. The empirical formula obtained in this study was proven by other soil samples.

A Convergence Study on the Measurement of Bacterial Pollution in Medical Ultrasonic Practice (의료용 초음파 실습 시 장치의 세균오염도 측정에 관한 융합적 연구)

  • Kim, Dong-Heun;Park, Sang-Hee;Park, Gyu-Tae;Jung, Won-Hee;Kim, So-Yeon;Hong, Hee-Jin;Son, Na-Ra;Nam, Seoul-Hee;Han, Man-Seok
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.10
    • /
    • pp.75-80
    • /
    • 2019
  • During the medical ultrasound exercise at school, we randomly select parts of the ultrasound device and areas with the most contact in the abdominal phantom to detect bacteria that are above the probe and determine the number of pathogens. I want to find out. The experimental method was rubbed 20 times with the sterilized cotton swab for sterilization and then smeared on Lysogeny broth (LB) agar, put into the incubator and incubated for 48 hours, and the colony forming unit (CFU) count was measured. The bacterial distribution of probe handle and abdominal phantom was evaluated by evaluation. As a result, the CFU value is the lens was $3.0{\pm}0.87$, print button was $5.5{\pm}1.06$, freeze button was $8.0{\pm}4.95$, phantom was $20.0{\pm}2.78$, line was $23.5{\pm}2.50$, and probe handle was measured as $35.3{\pm}10.75$. In this study, it is expected that attention to infection control of equipment during practice during medical ultrasound practice can be highlighted and further contributed to the reduction of bacterial infection rate of ultrasound devices.

A Study on the Precision Measurement of Metallic Resistivity by Four Terminal Method (4 단자 방법에 의한 금속 비저항의 정밀측정에 관한 연구)

  • Kang, Jeon-Hong;Kim, Han-Jun;Yu, Kwang-Min;Han, Sang-Ok;Park, Kang-Sic;Lee, Sei-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.498-499
    • /
    • 2007
  • 금속 비저항의 측정방법은 4단자 방법을 비롯한 van der Pauw 방법, Four-Point Probe(FPP) 방법, eddy current 방법 등이 사용되고 있으며, 시료의 혈상과 크기에 따라서 그 측정방법은 각각 다르다. 본 연구에서는 그 중 4단자 방법에 의한 정밀측정방법과 측정불확도 평가에 관하여 고찰하였다. 4단자 방법은 시료가 바(bar)나 봉(rod) 형상이면 측정이 가능하며, 시료의 정밀가공과 측정기술을 통하여 측정 불확도를 줄일 수 있다.

  • PDF

Quality Management of ITO Thin Film for OLED Based on Relationship of Fabrication and Characteristics (OLED용 ITO박막의 공정조건과 품질특성 추론에 근거한 품질관리)

  • Seo, Jeong-Min;Park, Keun-Young;Lee, Sang-Ryong;Lee, Choon-Young
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2008
  • Recently, research on a flat panel display(FPD) has focused on organic light-emitting display(OLED) which has wide angle of view, high contrast ratio and low power consumption. ITO(Indium-Tin-Oxide) films are the most widely used material as a transparent electrode of OLED and also in many other display devices like LCD or PDP. The performance and efficiency of OLED is related to the surface condition of ITO coated glass substrate. The typical surface defect of glass substrate is measured for electric characteristics and physical condition for transmittance and roughness. Since ITO coated glass substrate can be destroyed for inspection about surface roughness, sheet resistance, film thickness and transmittance, precise fabrication condition should be made based on the estimated relationship. In this paper, ITO films were prepared on the commercial glass substrate by the Ion-Plating method changing the partial pressure of gas(Ar, 02) and the chamber temperature between $200^{\circ}C$ and $300^{\circ}C$. The characteristics of films were examined by the 4-point probe, supersonic thickness measurement, transmittance measurement and AFM. We estimated the relationship between processing parameters(Ar gas, O2 gas, Temperature) and properties of ITO films (Sheet Resistance, Film Thickness, Transmittance, Surface Roughness).

Time Resolution of Fourier Cutoff Probe for Electron Density Measurement

  • Na, Byeong-Geun;Yu, Gwang-Ho;Kim, Dae-Ung;Yu, Dae-Ho;Yu, Sin-Jae;Kim, Jeong-Hyeong;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.273-273
    • /
    • 2012
  • 컷오프 진단법은 두 개의 탐침 형태로 제작된 마이크로 웨이브 진단법으로, 간단한 수식을 통해 전자밀도, 전자온도 등을 측정할 수 있다. 컷오프 탐침은 방사 안테나, 측정 안테나와 네트워크 분석기로 구성되어 있다. 네트워크 분석기는 두 안테나 사이의 플라즈마 투과 스펙트럼을 만드는데 쓰이며, 스펙트럼 분석을 통해 플라즈마 변수들을 측정할 수 있다. 이 진단법은 장치나 분석방법이 매우 간단한 장점을 지니며, 약 1 mW 정도의 적은 파워를 사용하여 플라즈마 상태를 거의 변화시키지 않는 측정이 가능하다. 또한 CF4와 같은 공정 가스를 이용한 플라즈마에서도 사용이 가능하다. 그러나 컷오프 진단법을 사용한 측정은 다른 종류의 진단법과 마찬가지로, 약 1초 정도의 긴 시간을 필요로 하는 단점이 있어, 펄스 플라즈마나 토카막과 같이 빠르게 변하는 플라즈마를 측정하기에는 무리가 있다. 최근에 개발된 푸리에 컷오프 탐침(Fourier Cutoff Probe, FCP)는 기존의 컷오프 탐침의 느린 시간분해능을 개선하기 위해 개발되었다. [1] 펄스 형태의 단일신호를 플라즈마를 투과하기 전후로 비교하면 투과 스펙트럼 및 플라즈마 변수들을 얻을 수 있으며, 기존 연구에서 구한 시간 분해능은 약 15 나노초였다. 이 값은 펄스 발생장치의 스펙에 따라 변하게 된다. 펄스폭이 짧을수록 시간분해능이 좋아지지만, 무한정 좋아질 수는 없다. 이 논문에서는 FCP 측정의 시간 분해능을 이론적으로 구하고, 시간 분해능의 이론적 한계를 구했다.

  • PDF

Optimal Fuzzy Sliding-Mode Control for Microcontroller-based Microfluidic Manipulation in Biochip System

  • Chung, Yung-Chiang;Wen, Bor-Jiunn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.196-201
    • /
    • 2004
  • In biometric and biomedical applications, a special transporting mechanism must be designed for the ${\mu}$TAS (micro total analysis system) to move samples and reagents through the microchannels that connect the unit procedure components in the system. An important issue for this miniaturization and integration is microfluid management technique, i.e., microfluid transportation, metering, and mixing. In view of this, this study presents an optimal fuzzy sliding-mode control (OFSMC) design based on the 8051 microprocessor and implementation of a complete microfluidic manipulated system implementation of biochip system with a pneumatic pumping actuator, a feedback-signal photodiodes and flowmeter. The new microfluid management technique successfully improved the efficiency of molecular biology reaction by increasing the velocity of the target nucleic acid molecules, which increases the effective collision into the probe molecules as the target molecules flow back and forth. Therefore, this hybridization chip was able to increase hybridization signal 6-fold and reduce non-specific target-probe binding and background noises within 30 minutes, as compared to conventional hybridization methods, which may take from 4 hours to overnight. In addition, the new technique was also used in DNA extraction. When serum existed in the fluid, the extraction efficiency of immobilized beads with solution flowing back and forth was 88-fold higher than that of free-beads.

  • PDF

Flow and Heat Transfer Characteristics due to the Variations of the Angle of Attack at the Vortex Generators located behind a Circular Cylinder (원주 후미에 부착된 와동발생기의 영각 변화에 따른 유동 및 열전달 특성)

  • 하홍영;홍철현;양장식;이기백
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.439-449
    • /
    • 2002
  • Experimental investigations of the flow structure and heat transfer enhancement in a channel with a built-in circular cylinder and a wing-let type vortex generator are presented. Without any vortex generators, relatively low heat transfer takes place in the downstream of the circular cylinder where is a recirculation region with low velocity fluid is formed. However with a wing-let type longitudinal vortex generator in the wake region behind the cylinder, heat transfer in the region can be enhanced. In order to control the strength of longitudinal vortices, the angle of attack of the vortex generators is varied from $20^{circ} to 45^{\circ}$, but spacings between the vortex generations are fixed to be 5 mm. The 3-dimensional mean velocity field downstream of the vortex generator is measured by a five-hole pressure probe, and the hue-capturing method using thermochromatic liquid crystals has been used to provide the local distribution of the heat transfer coefficient. The vorticity field and streamwise velocity contour are obtained from the velocity field. Streamwise distributions of averaged Stanton number on the measurement planes show very similar trends for all the experimental cases($\beta=20^{circ}, 30^{circ} and 45^{\circ}$). Circulation strength and heat transfer coefficient have the maximum values when the angle of attack($\beta$) is $30^{\circ}$.

Al, Ga, In이 도핑된 ZnO 기반의 투명 전도막 제작

  • Kim, Gyeong-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.11a
    • /
    • pp.138-138
    • /
    • 2009
  • Al, Ga and In doped ZnO thin film were prepared by faing targets sputtering as a function of oxygen gas contents at R.T. Base pressure was $2{\times}10^{-6}torr$, and working pressure was 1mTorr. The properties of thin films on the electrical and optical properties of the deposited films were investigated by using a four-point probe (Chang-min), a Hall Effect measurement (Ecopia) and an UV/VIS spectrometer (HP). The minimum resistivities of AZO, GZO and IZO thin film were $6.5{times}10^{-4}[{\Omega}-cm],5.5{\times}10^{-4}[{\Omega}-cm]$ and $4.29{\times}10^{-4}[{\Omega}-cm]$. The average transmittance of over 80% was seen in the visible range.

  • PDF

Precise Measurement of Magnetic Field Using CW-NMR Technique (CW-NMR 기법을 이용한 자기장 정밀측정)

  • 이정한;이대행;김민철;이순칠;홍계원;이호준
    • Journal of the Korean Magnetics Society
    • /
    • v.5 no.1
    • /
    • pp.79-85
    • /
    • 1995
  • A precise magnetic field probe was designed to measure the field distribution inside a superconducting magnet. The operation principle of the developed equipment is based on cw-NMR. The range of field is from 2.8 T to 5.8 T, and the resolution is better than 0.3 ppm NMR samples were water and heavy water contained in a tube of 4 mm diameter and 4mm height. This equipment can be manufactured very inexpensively compared with the currently available commertial ones.

  • PDF

A Permeability Measurement of Small Unilamellar Vesicles by 6-Carboxyfluorescein$^*$

  • Lee, Choong-Hee;Choi, Myung-Un
    • Bulletin of the Korean Chemical Society
    • /
    • v.5 no.4
    • /
    • pp.154-158
    • /
    • 1984
  • In order to characterize the permeability of small unilamellar vesicles (SUV), efflux of 6-carboxyfluorescein (6-CF) from the vesicles was monitored spectrophotofluorometrically. Since the entrapped highly quenched 6-CF (200 mM) became fluorescent upon release from the vesicles, the 6-CF could be used as an efflux probe. SUV containing entrapped 6-CF was prepared from egg phosphatidylcholine and separated by gel filtration on Sepharose 4B. Observed change of relative fluorescent intensity with time was sigmoidal. From this curve, the parameter of permeability was determined either by half-time or a released amount per unit time from the initial slope. Half-time of efflux of prepared SUV having 302 ng phospholipid/ml in 10 mM Tris-HCl buffer pH 7.4 was 21.0 min at $37{\circ}C$. Various factors which could affect the half-time were examined including temperature, pH, salt, and vesicle concentration. In particular the effect of vesicle concentration on the efflux revealed that the permeability can be a function of the concentration.