• Title/Summary/Keyword: 4 probe measurement

Search Result 310, Processing Time 0.025 seconds

Measurement of Refractive Index Profile of Optical Fiber Using the Diffraction Phase Microscope (회절위상현미경을 이용한 광섬유의 굴절률 프로파일 측정)

  • Jafar-Fard, Mohammad R.;Moon, Sucbei
    • Korean Journal of Optics and Photonics
    • /
    • v.23 no.4
    • /
    • pp.135-142
    • /
    • 2012
  • We have developed a measurement method of the refractive index profile of an optical fiber by using diffraction phase microscopy. In the microscope system, the reference light was extracted directly from the probe light that passed through the sample by means of pinhole filtering with a diffraction grating. The spatial interference pattern produced by the probe light and the reference light was processed to generate the phase image of the sample fiber. The index profile was obtained by the inverse Abel transform of the phase profile. In order to remove the background phase that originated from the index difference between the cladding and the surrounding medium, the background phase was calculated from the phase data of the cladding to make a core phase profile that can be directly transformed to the index profile of the core without the full phase image that includes the entire cladding part.

Efficient Measurement of Wind Velocity and Direction Using Dual Rotor Wind Power Generator in Vessel (Dual Rotor 풍력발전을 이용한 선박에서의 효과적인 풍향 풍속 측정)

  • Choi, Won-Yeon;Park, Gye-Do;Lee, Jang-Myung
    • The Journal of Korea Robotics Society
    • /
    • v.5 no.4
    • /
    • pp.309-317
    • /
    • 2010
  • This paper proposes an efficient measurement system for the velocity and direction of the wind using the dual rotor wind power generator in vessel. Conventional digital measurement system recognizes the direction and the velocity of the wind using the electric compass or synchronous motor and Vane probe method using hall sensors. But each system has its own short-comings: the synchronous motor has a larger measurement error than the magnetic compass and magnetic compass is weak for the external disturbances such as fluctuation of the vessel. To compensate these short-comings, this paper proposes a new compensation algorithm for the fluctuation errors according to the external interference and the unexpected movement of the vessel along the roll and pitch directions. The proposed system is implemented with the dual compasses and a synchronous motor. The proposed independent power generation system can be operated by itself and can raise the efficiency of the wind power generation systems of 30 ~ 400 W installed along the vertical and horizontal axes. The proposed system also realizes the efficient and reliable power production system by the MPPT algorithm for the real-time recognition of the wind direction and velocity. An advanced switching algorithm for the battery charging system has been also proposed. Effectiveness of the proposed algorithm has been verified through the real experiments and the results are demonstrated.

Directivity Analysis for Optimal Design of Ultrasonic Angle Beam Transducer (초음파 사각 트랜스듀서의 최적설계를 위한 지향성 해석)

  • Nam, Young-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.9
    • /
    • pp.796-803
    • /
    • 2008
  • Ultrasonic testing uses the directivity of the ultrasonic wave, which propagates in on direction. The directivity is expressed as the relationship between the propagate direction and its sound pressure. The directivity of an ultrasonic wave is related to the choice of probe arrangement, testing sensitivity and scanning pitch and correct measurement of defect size and location. This paper describes on the directivity measurement of ultrasonic wave using the visualization method. The directivity of shear wave emitted from the angle beam transducer were constant during propagation. The difference of directivity was existed between 2 MHz and 4 MHz angle beam transducers. When these experimental results were compared with the theory which was based on the continuous wave, it showed good agreement with theoretical directivity on the principal lobe.

Comparison of Torsional Vibration Measurement Techniques

  • Verrecas, B.;Janssens, K.;Britte, L.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.441-441
    • /
    • 2012
  • Noise and vibration performance plays an important role in the development of rotating components, such as engines, drivelines, transmission systems, compressors and pumps. The presence of torsional vibrations and other specific phenomena require the dynamic behaviour of systems and components to be designed accurately in order to avoid comfort and durability related problems. This paper provides an overview of the instrumentation and challenges related to torsional vibration testing. The accuracy and performance of five measurement techniques (high-speed incremental encoder, dual beam laser interferometer, zebra tape, zebra disc, direct pulse measurements with magnetic probe) is investigated by measurements on a Fiat Punto 1.4 liter engine. The potential sources of error are discussed to explain the inaccuracies of each technique.

  • PDF

Flux Loss and Neutron Diffraction Measurement Ag-sheathed Bi-2223 Tapes in terms of Flux Creep

  • Jang Mi-Hye
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.5
    • /
    • pp.204-210
    • /
    • 2005
  • Alternating current (AC) losses of two Bi-2223 ([Bi, Pb]: Sr: Ca: Cu: O = 2:2:2:3) tapes [(Tape I, un-twist-pitch) and the other with a twist-pitch of 10 mm (Tape II)] were measured and compared. These samples, produced by the powder-in-(Ag) tube (PIT) method, are multi-filamentary. Also, it's produced by non-twist and different twist pitch (8, 10, 13, 30, 50 and 70 mm). The critical current measurement was carried out under the environment in liquid Nitrogen and in zero-field by 4-probe method. Susceptibility measurements were conducted while cooling in a magnetic field. Flux loss measurements were conducted as a function of ramping rate, frequency and field direction. The AC flux loss increases as the twist-pitch of the tapes decreased, in agreement with the Norris Equation. Neutron-diffraction measurements have been carried out investigate the crystal structure, magnetic structures, and magnetic phase transitions in Bi-2223([Bi, Pb]:Sr:Ca:Cu:O)

Analysis of Growth Mechanism of Al Thin Film by in-situ Surface Reflectance Measurement During MOCVD Process (MOCVD에 의한 Al 박막 증착 중의 표면 반사도 측정을 통한 박막 성장 메커니즘 분석)

  • Kim, Kisoo;Seo, Moon Kyu
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.2
    • /
    • pp.104-108
    • /
    • 2015
  • Al thin films were deposited on TiN/Si(100) via metal-organic chemical vapor deposition using N-methylpyrrolidine alane as a precursor. Characterization of the deposited films were investigated with SEM, XRD, ${\alpha}$-step, AFM, 4-point probe. The early stage of Al thin film deposition was analyzed by in-situ surface reflectance measurement with laser and photometer apparatus. The surface reflectance were changed greatly during the initial 30~40 seconds. There were two increases and two decreases in the surface reflectance, thus the sequence of Al films were deposited at 8 significant points of the surface reflectance change. Surface topograph and cross-sectional view of each film were analyzed with SEM. Al films were grown in the complex mechanism of Volmer-Weber and Stranski-Krastanov process.

In Vivo Doppler-Based Measurement of Bending Vibration Velocity in Liver Vibrated by Lo7v Frequency Signal (초음파 Doppler법에 의한 비침투적인 생체조직의 진동속도 계측)

  • 박무훈;장윤석
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.4
    • /
    • pp.407-412
    • /
    • 1997
  • In this paper, we present a new method to diagnose the characteristics of the soft tissue, especially a liver. In order to diagnose the characteristics of a liver, it is necessary to evaluate the propagation delay time and propagation velocity of bending vibration In a liver. For this purpose, we measure the propagation velocity of bending vibration in a liver for low frequency forced vibration using a standard ultrasonic Doppler diagnosis equipment. We have carried out preliminary experiments by using an ultrasonic probe of 3.5MHz and obtained some results. This new measurement method developed here can be applied to new research and medical fields for acoustic non-invasive diagnosis of soft tissue.

  • PDF

A Study on properties of ZnO thin film for Film Bulk Acoustic Resonator (FBAR) application (FBAR 응용을 위한 ZnO 박막의 특성에 대한 연구)

  • Jeong, Young-Hak;Lee, Kyu-Il;Kim, Eun-Kwon;Lee, Jong-Duk;Song, Joon-Tae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.688-692
    • /
    • 2004
  • In this paper, zinc oxide (ZnO) films with c-axis (002) orientation have been successfully deposited on the Al/Si substrate by rf magnetron sputtering method. The deposited films were characterized by substate temperature. Physical and structural properties of the deposited films were investigated by X-ray diffraction (XRD), scanning electron microscopy (SEM) and atomic force microscopy (AFM) measurement. Electrical Properties of the deposited films were investigated by 4-poing probe and LCR meter measurement. The optimal condition in this experimental result was found at foot of the substrate temperature and shown good film quality for FBAR application.

  • PDF

Visualization and Flowfield Measurements of the Vortical Flow over a Double-Delta Wing

  • Sohn, Myong-Hwan;Jang, Young-IL
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.63-74
    • /
    • 2003
  • The vortical flow of a 65-deg flat plate delta wing with a leading edge extension(LEX) was examined through off-surface visualization, 5-hole probe and hot-film measurements. The off-surface flow visualization technique used micro water droplets generated by a home-style ultrasonic humidifier and a laser beam sheet. The angles of attack ranged from 10 to 30 degrees, and the sideslip angles ranged from 0 to -15 degrees. The Reynolds number was $1.82{\times}10^5$ for the flow visualization, and $1.76{\times}10^6$ for the 5-hole probe and hot-film measurements. The comparison of the visualization photos and the flow field measurement showed that the two results were in a good agreement for the relative position and the structure of the wing and LEX vortices, even though the flow Reynolds numbers of the two results were much different. The wing vortex and the LEX vortex coil each other while maintaining a comparable strength and identity at zero sideslip. Neither a looping of the wing vortex around the strake vortex, nor the lopsided coiling of the stronger strake and the weaker wing vortices was observed. At non-zero sideslip, the downward movement of the LEX vortex when going downstream was enhanced on the windward side, and the downward and inboard movement of the LEX vortex when going downstream was suppressed on the leeward side. The counterclockwise coiling of the wing and LEX vortices was decreased significantly on the leeward side.

A study on correlation between frictional coefficients and subjective evaluation while rubbing cosmetic product on skin (화장품을 바를 때 피부 마찰계수의 변화와 주관적인 평가와의 상관관계 연구)

  • Kwon Young-Ha;Kwon Hyun-Joon;Rang Moon-Jeong;Lee Su-Min
    • Science of Emotion and Sensibility
    • /
    • v.8 no.4
    • /
    • pp.385-391
    • /
    • 2005
  • A frictional coefficients of in-vivo skin characteristic is the most important factor of the cutaneous mechanical properties ant the method of evaluating skin care in the fields of cosmetics products. In-vivo skin characteristic varies in many different ways depends on what is applied to the skin, loading condition, shape, surface roughness, and material of the probe. In this research, we designed a system which can be measured frictional coefficients of a human skin on real time. It consists of multi-components load-cell, actuator, linear motor and arm fixator. This measurement system was automatically controlled by computer. We measured frictional coefficients between probe an4 skin using this system ant inquired adjectives for subjective evaluation while rubbing cosmetic product on skin. Lastly, we analyzed correlation between two factors by calculating Pearson Correlation Coefficient. As a result, we could know that frictional coefficients varied from 0.17-1.2 according to cosmetic products, normal forte, materials and surface conditions of probe. We also confirmed sensual feelings of cosmetic products have close correlation with frictional coefficients.

  • PDF