• Title/Summary/Keyword: 4 inch)

Search Result 530, Processing Time 0.027 seconds

A RADIOGRAPHIC STUDY ON TEMPOROMANDIBULAR JOINT TROUBLE (악관절기능장애자의 방사선학적 연구)

  • Choe Byung Woon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.9 no.1
    • /
    • pp.13-18
    • /
    • 1979
  • The purpose of this study was to investigate the radiographic images of Temporomandibular joint trouble patients. This study included 186 patients with the chief complaints of TMJ pain and dysfunction. Their age ranged from 17 to 68 years. All patients were identified in the department of Dental mary of College of Dentistry, Seoul National University, Apr. 1978 to Jun. 1979. The author has observed the radiographic variations of two positions of condylar head taken by modified transcranial oblique-lateral projection, which are one in centric occlusion and the other in 1 inch(2.54㎝) mouth open. The results were obtained as follows; 1. In centric occlusion, the distances and positional relationship between the summit of condylar head and the deepest point of articular fossa revealed more or less large variations; Normal range is of 37.9%, anterior displacement of 37.3% and posterior displacement of 22.6%. 2. In the horizontal movement of condylar heads when on 1 inch mouth open, it was revealed that normalrange was of 46.5%, anterior displacement of 12.3%, posterior displacement of 41. 1 %. 3. In the positional interrelationship of both condylar heads when on 1 inch mouth open, it was revealed that symmetry(71. 5%) occurred approximately 2.5 times as many as asymmetry. 4. In both centric occlusion and 1 inch mouth open, it was showed that almost all estimated figures were greater in male than in female, and in the horizontal movement of condylar head when on 1 inch open, it was showed that hypermobility was dominant in male and hypomobility in female.

  • PDF

2.22-inch qVGA a-Si TFT-LCD Using a 2.5 um Fine-Patterning Technology by Wet Etch Process

  • Lee, Jae-Bok;Park, Sun;Heo, Seong-Kweon;You, Chun-Ki;Min, Hoon-Kee;Kim, Chi-Woo
    • Journal of Information Display
    • /
    • v.7 no.3
    • /
    • pp.1-4
    • /
    • 2006
  • 2.22-inch qVGA $(240{\times}320)$ amorphous silicon thin film transistor liquid active matrix crystal display (a-Si TFT-AMLCD) panel has been successfully demonstrated employing a 2.5 um fine-patterning technology by a wet etch process. Higher resolution 2.22-inch qVGA LCD panel with an aperture ratio of 58% can be fabricated as the 2.5 um fine pattern formation technique is integrated with high thermal photo-resist (PR) development. In addition, a novel concept of unique a-Si TFT process architecture, which is advantageous in terms of reliability, was proposed in the fabrication of 2.22-inch qVGA LCD panel. Overall results show that the 2.5 um fine-patterning is a considerably significant technology to obtain higher aperture ratio for higher resolution a-Si TFT-LCD panel realization.

COMPARISON OF ABSORBED DOSES RESULTING FROM VARIOUS INTRAORAL PERIAPICAL RADIOGRAPHY (전악 치근단 방사선사진 촬영시 촬영조건에 따른 흡수선량 변화에 대한 연구)

  • Kang Mi-Ae;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.297-308
    • /
    • 1995
  • This study was designed to measure the absorbed dose to organs of special interest from full mouth with intraoral film(l4 films) and to compare the five periapical techniques. Thermoluminescent crystals(TLD-100 chip) were located in brain, orbit, bone marrow of mandibular ramus, bone marrow of mandibular body, bone marrow of 4th cervical spine, parotid gland, submandibular gland and thyroid gland. X -ray machine was operated at 70kVp and round collimating film holding device(XCP) and rectangular collimating film holding device(Precision Instrument) were used. The distance from the X-ray focus to the open end of the collimator was 8 inch, 12 inch and 16 inch. The results were as follows : 1. The absorbed dose was the highest in bone marrow of mandibular body(5.656mGy) and the lowest in brain (0.050mGy). 2. Generally, the lowest absorbed dose was measured from 16 inch cylinder, rectangular collimating film holding device with paralleling technique. But, in bone marrow of mandibular body and the floor of mouth, the highest absorbed dose was measured from 12 inch cylinder, rectangular collimating film holding device with paralleling techniques. 3. Comparing of five intraoral radiographic techniques, it was appeared statistically significant reduction of the absorbed doses measured with rectangular collimating film holding device compared to XCP film holding device (P<0.05). 4. No statistically significant reduction in the absorbed dose was found as cylinder length was changed(P>0.05).

  • PDF

A Review on 'cunkou(寸口)' in Maijing(脈經) ("맥경(脈經)"중(中) '촌구(寸口)'에 대한 고찰(考察))

  • Song, Ji-Chung;Jeong, Hyun-Jong;Keum, Kyungsoo;Eom, Dong-Myung
    • Journal of Korean Medical classics
    • /
    • v.25 no.4
    • /
    • pp.95-103
    • /
    • 2012
  • Objective : There are several terms on palpation such as cunkou(寸口), qikou(氣口), maikou(脈口). In traditional medicine dictionary or even WHO international standard terminologies on traditional medicine in the western pacific region, there are no discriminations about them. However, there are some differences in usages of cunkou, qikou, maikou at Maijing. Method : First, we searched usages of term, cunkou, qikou, maikou in Huangdineijing(黃帝內經) and Maijing and compared the meanings. Result : Meanings of cunkou, qikou, maikou in Huangdineijing are pair with renying(人迎) and inch-bar-cubit on wrist. Meanings of cunkou in Maijing are pair with renying, inch-bar-cubit on wrist and only inch on wrist. Meanings of qikou, maikou in Maijing are inch-bar-cubit on wrist. Conclusion : Cunkou, qikou, maikou are known as same terms. However, scholars have to be cautious when they use cunkou, qikou, maikou term and comprehend those in book.

A Development of Overlay GTAW Welding System for Pipe Inside Straight Process (직선형 프로세스 파이프 내면 오버레이 GTAW 용접시스템 개발)

  • Eun, Jong-Mok;Lee, Young-Kyu
    • Journal of Welding and Joining
    • /
    • v.32 no.2
    • /
    • pp.4-8
    • /
    • 2014
  • In this research, GTA overlay welding system is developed for inside of straight pipes in various diameter. It can be applied to oil, ship building and plant industry, especially pipes connected to pressure vessels, for the purpose of cost reduction by cladding inside of pipes with corrosion and heat resistant alloys such as stainless steel or Inconel. Developed system consists of GTA power source, torch, wire feeding system, automatic arc length adjusting device, CCD camera and cooling unit. Two types of pipe inside overlay welding system are developed. One is for maximum 3m pipe length with 3 inch ~ 12 inch pipe outer diameter. Another type can be applied to maximum 12m pipe length with 7 ~ 24 inch OD. Developed system successfully produced inside cladded pipe and the results are shown through cross sectional images of the pipes.

The Study of High Brightness Prism Patterned LGP using Optical Simulation Analysis

  • Ok, Chul-Ho;Han, Jeong-Min;Hwang, Jeoung-Yeon;Seo, Dae-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.178-181
    • /
    • 2007
  • We have designed high performance prism light-guide plate (LGP) in 17 inch TFT-LCD. In test result to embody high brightness BLU in case of LGP of base and upper surface with 17 inch, thickness 8 mm adding prism construct, it is superior brightness improvement than previous that of printing form about some 20% and in this course to embody actual material it succeeded prism LGP production by 17 inch injection form process.

EFFECTS OF LOW-TEMPERATURE HEAT TREATMENT ON ELASTIC MEMORY PROCESS OF COLD WORKED STAINLESS STEEL WIRE (열처리가 냉간가공한 stainless steel wire의 복원양상에 미치는 영향)

  • Oh, Jeung-Sei;Park, Soo-Byung;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.22 no.3 s.38
    • /
    • pp.647-656
    • /
    • 1992
  • The purpose of this study was to evaluate the elastic memory process in cold worked stainless steel wire and the effect of heat treatment on it. 0.018 inch round and $0.019\times0.025$ inch rectangular wire (ORMCO stainless wire) were used in this study. Each wire type had 4 groups: non-heat treatment group, furnace heat treatment group, electric current heat treatment group, and bending after heat treatment group. Each group was consisted of 10 specimens. With the Jig, each wire was bent into v-shape uniformly, and width of two free ends of each v-shaped wire was measured by caliper (to the point of 0.1 mm correctly) at time interval of offjig, after heat treatment, 1, 2, 3, 4 hours, 1, 2, 3, 4, 5, 6 days, 1, 2, 3, 4 weeks after. The results were as follows: 1. In non-heat treatment group and bending after heat treatment group, elastic memory process was occured $60\%$ within 1 hour, and more than $90\%$ within 1 week. 2. In furnace and electric current heat treatment group, almost all elastic memory process was occured during teat treatment, and then specimen was stabilized dimensionally. 3. Magnitude of deformation by elastic memory was greater in heat treatment group than non heat treatment group and bending after heat treatment group. 4. There was no remarkable difference in deformation pattern between 0.018 inch round wire and $0.019\times0.025$ inch rectangular wire.

  • PDF

Application Defects Detection in the Small-Bore Pipe Using Infrared Thermography Technique (적외선열화상 카메라를 이용한 원전 소구경 감육배관의 결함 검출)

  • Yun, Kyung-Won;Kim, Dong-Lyul;Jung, Hyun-Chul;Hong, Dong-Pyo;Kim, Kyeong-Suk
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.1
    • /
    • pp.34-39
    • /
    • 2013
  • In the advanced research deducted infrared thermography (IRT) test using 4 inch pipe with artificial wall-thinning defect to measure on the wall-thinned nuclear pipe components. This study conducted for defect detection condition of nuclear small-bore pipe research using deducted condition in the advanced research. Defect process is processed by change for defect length, circumferential direction angle, wall-thinning depth. In the used equipment IR camera and two halogen lamps, whose full power capacitany is 1 kW, halogen lamps and Target pipe experiment performed to the distance of the changed 1 m, 1.5 m, 2 m. To analysis of the experimental results ensure for the temperature distribution data, by this data measure for defect length. artificial defect of 4 inch pipe is high reliability in the 2 m, but small-bore pipe is in the 1.5 m from the defect clearly was detected.

Synthesis of flame retardant acrylic emulsion pressure sensitive adhesives by co-polymerization with phosphoric flame retardant monomer (인계 난연 단량체와의 공중합을 통한 난연성 수성 아크릴 에멀젼 점착제 제조)

  • Jeon, Min Seok;Jung, Ji Hun;Kim, Gu Ni
    • Journal of Adhesion and Interface
    • /
    • v.20 no.4
    • /
    • pp.135-139
    • /
    • 2019
  • In this work, flame retardant acrylic emulsion pressure sensitive adhesives were newly polymerized combining phosphorous flame retardant monomer and acrylic monomer like butyl acrylate, 2-ethylhexyl acrylate, methyl methacrylate, acrylic acid, and 2-hydroxyethyl methacrylate. The process of polymerization showed 100% of conversion at solid content of 65%, and viscosity of acrylic emulsion was increased up to 5500 cps when phosphorous flame retardant monomer was added into acrylic emulsion. The structure of flame retardant acrylic emulsion was identified using FT-IR and thermal properties like glass transition temperature (Tg) were checked by differential scanning calorimeter (DSC). Acrylic emulsion without phosphorous flame retardant monomer had Tg of -44.1℃ and peel strength of 2,100gf/inch, however, flame retardant acrylic emulsion showed maximum Tg (-31.4℃) and peel strength of 200gf/inch when 15 part of phosphorous flame retardant monomer was added. Flammability test was also conducted to confirm the application of flame retardant acrylic emulsion as the flame retardant addtive.

Properties of Alkali Hydrolyzed Polyester Fabric by CDR/Liquor-Flow Type (연속/액류방식에 의한 폴리에스테르 직물의 감량특성)

  • Seo, Mal-Yong;Park, Han-Do;Park, Ki-Su;Han, Sun-Ju
    • Textile Coloration and Finishing
    • /
    • v.9 no.4
    • /
    • pp.39-46
    • /
    • 1997
  • In this study, Two types of polyester fabrics were hydrolysed with NaOH using the CDR m/c of pad-steam type and the Sofleena m/c of liquor-flow type to determine the alkali hydrolysis properties of polyester fabrics. The results were as follows: Under the same conditions, the weight loss of charmeuse was about 0.5% and 2~3% higher than that of pebble with CDR m/c and with Sofleena m/c, respectively. The weft density of pebble decreased about 14picks/inch with CDR m/c and 3picks/inch with Sofleena m/c comparing to the untreated sample at 18% of weight loss, while the weft density of charmeuse decreased about 5picks/inch with CDR m/c and 2picks/inch with Sofleena m/c at 20% of weight toss. K/S value decreased almost identically within about 11% weight loss of pebble and 8% of charmeuse processed with both CDR and Sofleena. However, in the above these weight losses, K/S value of the fabrics processed with Sofleena was higher than that of fabrics processed with CDR. The bending rigidity of warp direction of the fabrics ($2{\times}10^{-2}gf.cm^2 /cm$ higher for charmeuse and ($7{\times}10^{-3}gf.cm^2 /cm$ higher for pebble) processed with CDR m/c was higher than that of the fabrics processed with Sofleena m/c.

  • PDF