• Title/Summary/Keyword: 4 dimensional echocardiography

Search Result 31, Processing Time 0.02 seconds

Two-Dimensional Echocardiographic Prediction of Prosthetic Aortic Valve Size (심초음파도를 이용한 대동맥인공판막치수 예)

  • 박창권
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.655-658
    • /
    • 1987
  • Aortic annulus size was measured by two-dimensional echocardiography [2DE] in 29 patients undergoing aortic valve replacement or double valve replacement in order to predict prosthetic aortic valve size. Fifteen patients had aortic stenoinsufficiency, eleven had aortic insufficiency, and three had aortic stenosis. 2DE measurements of aortic annulus diameter, as determined from the parasternal long-axis view, demonstrated a high correlation with actual prosthetic valve size implanted at surgery [r=0.85, p<0.05]. 2DE exactly predicted actual prosthetic valve size in 8 of 29 patients [27.6%], was within 1mm of prosthetic valve size in 11 of 29 patients [37.9%], was within 2mm of prosthetic valve size in 8 of 29 patients, and was within 3mm of prosthetic valve size in 2 patients.

  • PDF

Surgical treatment of coarctation of aorta in infants -Four cases of subclavian flap aortoplasty- (유아에서의 대동맥 축착증 치험 4예)

  • 백광제
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.506-514
    • /
    • 1986
  • Coarctation of aorta is rather common congenital cardiovascular defect in the western countries, but it is known to be rare in Korea. And no coarctation of Aorta has been reported and operated upon during early infancy in Korea. During 4 months period from May 1984 to September 1984, four small infants of coarctation of aorta were seen and treated surgically by subclavian flap aortoplasty in Guro Hospital, Korea University. All infants were male, ranging from 7 days to 54 days old [mean 29 days], weighing between 3.2 Kg and 5.0 Kg [mean 4.1 Kg], and all were in congestive heart failure. Examination of the femoral artery pulse gave in all cases clues to the diagnosis. By Two dimensional echocardiogram, detail anatomical features as well as the diagnosis were revealed and associated anomalies, for example, ventricular septal defect could be seen. Besides one case of isolated coarctation of aorta, other three infants had associated VSD. The 3 patients with VSD were treated by pulmonary artery banding in addition to aortoplasty. The postoperative course were smooth in all patients. In conclusion, coarctation of aorta may not be so rare in Korea as we thought previously. The importance of femoral pulse examination can not be overemphasized for the diagnosis. As we experienced, two-dimensional echocardiography in most cases can substitute those invasive examinations such as angiography and catheterization which carry difficulty and risk in infants.

  • PDF

Early Valve Replacement in Patient with Native Valve Endocarditis - Report of Seven Cases - (활동기 자가판 심내막염의 판막치환술: 7례 경험)

  • 허동명
    • Journal of Chest Surgery
    • /
    • v.24 no.10
    • /
    • pp.979-986
    • /
    • 1991
  • From October 1988 to November 1989, seven patients underwent valve replacement during the active phase of native valve endocarditis. There were 4 males and 3 females whose mean age was 41 years[range, 16 to 68 years]. Preoperative two-dimensional and Doppler echocardiography showed vegetations and severe valvular regurgitation in all patients. Blood cultures were positive in 4, and negative in 3 patients Organisms were alpha-hemolytic Streptococcus in 2, Staphylococcus epidermidis in 1, Erysipelothrix rhusiopathiae in 1 patient Valve tissue cultures were negative in all patients. Intravenous antibiotic therapy had been done for 3 to 18 days in 5 patients pre-operatively and was not done in 2 patients, Indications for operation were heart failure in h, and systemic emboli in 1 patient. The aortic valve was involved in 3, mitral in 1, and both aortic and mitral in 3 patients, One operative death[14.4%] occurred in patient with cardiogenic shock before operation. Late death occurred in one on 14 months after operation. The remaining 5 patients were followed up over a two year period in good condition. In conclusion, native valve endocarditis with severe heart failure must be considered for early operation.

  • PDF

A Clinical Study of Patent Ductus Arteriosus (동맥관개존증의 임상적 고찰)

  • Bang, Jong-Gyeong;Kim, Gyu-Tae
    • Journal of Chest Surgery
    • /
    • v.20 no.2
    • /
    • pp.309-316
    • /
    • 1987
  • Since the first report of successful ligation of patent ductus arteriosus in 1939, it`s surgical intervention has become a routine and relatively safe procedure. During the past ten years from Aug. 1975 to Aug. 1985, 107 cases were operated on for a patent ductus arteriosus at the Department of thoracic and Cardiovascular Surgery, School of Medicine, Kyungpook National University. Clinical analysis of these cases was performed. Mean age at operation was 9.4 years, ranging from 20 months to 32 years. Sex ratio of female to male was 1.8;1. Most common symptoms were frequent respiratory infection, exertional dyspnea, and palpitation. Diagnosis was made by auscultation, 2 dimensional echocardiography, cardiac catheterization, and cineangiocardiography. A moderate to severe pulmonary hypertension was found in 42 cases [49.4%] in cardiac catheterization. Operative methods were multiple ligation of paten`. ductus arteriosus with or without Dacron or Teflon wrapping in 72 cases [68%], and division and suture in 34 cases [32%]. There were three operative deaths [2.8%]. The causes of death were hemorrhage from tearing of aorta, low cardiac output, and arrhythmia. All of these cases had moderate degree of pulmonary hypertension.

  • PDF

Echocardiographic Diagnosis of Mitral Valve Dysplasia Concurrent with Mitral Stenosis and Tricuspid Valve Dysplasia in a Dog (개에서 승모판 이형성증과 병발한 승모판 협착증 및 삼첨판 이형성증의 심초음파적 특징 1례)

  • Choi, Soo-Young;Lee, Jung-Woo;Lee, Young-Won;Choi, Ho-Jung
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.101-104
    • /
    • 2015
  • A 4-years-old, intact male Golden retriever dog was presented with abdominal distension and dyspnea. Physical examination revealed arrhythmia and cardiac murmur. Generalized cardiomegaly, pleural effusion and ascites were shown on thoracic and abdominal radiographs. Two-dimensional echocardiography revealed abnormal mitral and tricuspid valve motion, mitral and tricuspid regurgitation, left ventricular eccentric hypertrophy and left atrial dilation. Color-flow Doppler imaging revealed turbulent flow extending into the left ventricle during diastole from the mitral valve orifice, and into the left atrium during systole. Spectral Doppler recordings revealed highly increased early diastolic mitral valve inflow and prolonged pressure half-time of mitral inflow. Based on the echocardiographic examination, the diagnosis was made as the mitral valve dysplasia concurrent with mitral valve stenosis and tricuspid valve dysplasia.

Echocardiographic Diagnosis of Pulmonary Arterial Hypertension in Chronic Lung Disease with Hypoxemia (만성 저산소성 폐질환의 폐동맥 고혈압에 대한 심초음파 검사)

  • Chang, Jung-Hyun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.846-855
    • /
    • 1999
  • Background : Secondary pulmonary hypertension is an important final endpoint in patients with chronic hypoxic lung disease, accompanied by deterioration of pulmonary hemodynamics. The clinical diagnosis of pulmonary hypertension and/or cor pulmonale could be difficult, and simple noninvasive evaluation of pulmonary artery pressures has been an relevant clinical challenge for many years. Doppler echocardiography might to be a more reliable method for evaluating pulmonary hemodynamics in such patients in terms of the accuracy, reproducibility and easiness for obtaining an appropriate echocardiographic window than M-mode echocardiography. The aim of this study was to assess echocardiographic parameters associated with pulmonary arterial hypertension, defined by increasing right ventricular systolic pressure(RVSP), calculated from trans-tricuspid gradient in patients with chronic hypoxic lungs. Method : We examined 19 patients with chronic hypoxic lung disease, suspected pulmonary hypertension under the clinical guidelines by two dimensional echocardiography via the left parasternal and subcostal approach in a supine position. Doppler echocardiography measured RVSP from tricuspid regurgitant velocity in continuous wave with 2.5MHz transducer and acceleration time(AT) on right ventricular outflow tract in pulsed wave for the estimation of pulmonary arterial pressure. Results : On echocardiography, moderate to severe degree of pulmonary arterial hypertension was defined as RVSP more than 40mmHg, presenting tricuspid regurgitation. Increased right ventricular endsystolic diameter and shortened AT were noted in the increased RVSP group. Increased RVSP was correlated negatively with the shortening of AT. Other clinical data, including pulmonary functional parameters, arterial blood gas analysis and M mode echocardiographic parameters were not changed significantly with the increased RVSP. Conclusion : These findings suggest that shortened AT on pulsed doppler can be useful when quantifying pulmonary arterial pressure with increased RVSP in patients with chronic lung disease with hypoxemia. Doppler echocardiography in pulmonary hypertension of chronic hypoxic lungs is an useful option, based on noninvasiveness under routine clinical practice.

  • PDF

Echocardiographic Assessment of Papillary Muscle Size and Function in Normal Beagle Dogs

  • Kim, Mijin;Choi, Sooyoung;Choi, Hojung;Lee, Youngwon;Lee, Kija
    • Journal of Veterinary Clinics
    • /
    • v.36 no.3
    • /
    • pp.155-158
    • /
    • 2019
  • Morphologic changes or functional impairments of the papillary muscle (PM) can influence mitral valve competence. The purpose of this study was to investigate PM size and contractile function using two-dimensional and color tissue Doppler echocardiography in normal dogs. 35 unsedated Beagle dogs without cardiovascular disease were examined. The vertical (VD) and horizontal diameter (HD) of the posterior and anterior PM was measured at end-diastole, and compared with the thickness of the left ventricular posterior wall (LVPWd). Longitudinal systolic movement of the PM was quantified as myocardial velocity and strain using tissue Doppler. The VD, HD, and ratios (VD/LVPWd, HD/LVPWd, VD/HD) were significantly greater in the posterior than anterior PM (P < 0.001). The VD and HD of posterior PM and the HD of anterior PM were significantly correlated with LVPWd (r = 0.47, 0.44, and 0.42, respectively). Body weight was significantly correlated with VD of posterior PM (r = 0.37). The peak systolic tissue velocity of the PM was $4.93{\pm}1.25cm/sec$ and peak strain was $-30.83{\pm}11.92%$. PM size and systolic function can be quantitatively assessed using two-dimensional and tissue Doppler. The establishment of these objective PM measurements may be useful to evaluate morphological and functional abnormalities of the canine PM.

Development of Real-time Two-dimensional Doppler Echocardiography and its Clinical Significance

  • Omoto, Ryozp
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.1-4
    • /
    • 1984
  • Balancing left/right cardiac output is essential for the automatic control of total artificial hearts(TAH). A fuzzy logic-based control method is presented. We use left atrial pressure(LAP) and right atrial pressure(RAP) as indicators for left/right balancing. The fuzzy controller has four input variables which are measured LAP and RAP and their gradients. Desired variations in left cardiac output(LCO) and right cardiac output(RCO) are calculated to keep LAP and RAP within the Physiological limits. Computer simulations were performed to adjust fuzzy membership functions for variables and verify this control method. Results from simulations showed that LAP and RAP returned to the physiological limits while AoP and PAP stayed within the physiological limits.

  • PDF

A New Method for Aortic Valve Planimetry with High-Resolution 3-Dimensional MRI and Its Comparison with Conventional Cine MRI and Echocardiography for Assessing the Severity of Aortic Valvular Stenosis

  • Hae Jin Kim;Yeon Hyeon Choe;Sung Mok Kim;Eun Kyung Kim;Mirae Lee;Sung-Ji Park;Joonghyun Ahn;Keumhee C. Carriere
    • Korean Journal of Radiology
    • /
    • v.22 no.8
    • /
    • pp.1266-1278
    • /
    • 2021
  • Objective: We aimed to compare the aortic valve area (AVA) calculated using fast high-resolution three-dimensional (3D) magnetic resonance (MR) image acquisition with that of the conventional two-dimensional (2D) cine MR technique. Materials and Methods: We included 139 consecutive patients (mean age ± standard deviation [SD], 68.5 ± 9.4 years) with aortic valvular stenosis (AS) and 21 asymptomatic controls (52.3 ± 14.2 years). High-resolution T2-prepared 3D steady-state free precession (SSFP) images (2.0 mm slice thickness, 10 contiguous slices) for 3D planimetry (3DP) were acquired with a single breath hold during mid-systole. 2D SSFP cine MR images (6.0 mm slice thickness) for 2D planimetry (2DP) were also obtained at three aortic valve levels. The calculations for the effective AVA based on the MR images were compared with the transthoracic echocardiographic (TTE) measurements using the continuity equation. Results: The mean AVA ± SD derived by 3DP, 2DP, and TTE in the AS group were 0.81 ± 0.26 cm2, 0.82 ± 0.34 cm2, and 0.80 ± 0.26 cm2, respectively (p = 0.366). The intra-observer agreement was higher for 3DP than 2DP in one observer: intraclass correlation coefficient (ICC) of 0.95 (95% confidence interval [CI], 0.94-0.97) and 0.87 (95% CI, 0.82-0.91), respectively, for observer 1 and 0.97 (95% CI, 0.96-0.98) and 0.98 (95% CI, 0.97-0.99), respectively, for observer 2. Inter-observer agreement was similar between 3DP and 2DP, with the ICC of 0.92 (95% CI, 0.89-0.94) and 0.91 (95% CI, 0.88-0.93), respectively. 3DP-derived AVA showed a slightly higher agreement with AVA measured by TTE than the 2DP-derived AVA, with the ICC of 0.87 (95% CI, 0.82-0.91) vs. 0.85 (95% CI, 0.79-0.89). Conclusion: High-resolution 3D MR image acquisition, with single-breath-hold SSFP sequences, gave AVA measurement with low observer variability that correlated highly with those obtained by TTE.

A Case of Right Atrial Mass Associated with Hepatocellular Carcinoma (간세포암에 동반된 우심방 종괴 1례)

  • Park, Chan-Won;Choi, Jin-Soo;Kwon, Soon-Uk;Song, Young-Doo;Kim, Jun-Hwan;Lee, Heun-Joo
    • Journal of Yeungnam Medical Science
    • /
    • v.16 no.1
    • /
    • pp.119-124
    • /
    • 1999
  • Right atrial metastasis occurs in 1 to 4% of patients with hepatoma, and the extension to intracavitary or metastasis of a tumor as a large mass rare. However, the high risk of progressive heart failure and sudden death from the tricuspid valve obstruction necessitates prompt diagnosis of intracavitary extension, and adequate intervention is needed to prolong a patient's life. A 49 year-old female was referred to our hospital for further evaluation of a liver mass, which was identified at a local clinic. The liver mass was confirmed as hepatocellular carcinoma with CT and celiac angiographies findings. She was treated with transarterial chemoembolization. Thirty-four months after discharge, a low density right atrial mass was noted incidentally with chest computed tomography while investigating a massive right pleural effusion for possible pulmonary metastasis. Echocardiography showed a huge inhomogenous echogenic mass at the right atrium. The present report describes a case of primary hepatocellular carcinoma with a intracavitary cardiac mass detected with two dimensional echocardiography.

  • PDF