• Title/Summary/Keyword: 4차원컴퓨터단층촬영

Search Result 38, Processing Time 0.027 seconds

Developmental Study of Korean Frontal Sinus by using 3D CT Scan (3차원 컴퓨터단층촬영 영상을 이용한 전두동 발달의 연구)

  • Yun, In Sik;Rah, Dong Kyun
    • Archives of Craniofacial Surgery
    • /
    • v.10 no.2
    • /
    • pp.103-108
    • /
    • 2009
  • Purpose: Although there are many reports on the development of paranasal sinuses, few studies were performed with respect to the frontal sinus with 3D CT, especially in Korean children. In this study, we evaluated the normal development of frontal sinus in Korean children with 3D CT imaging. Methods: A total of 301 patients under the age of 20 were reviewed retrospectively. Maximal AP (anteroposterior) length, height and width were measured with the aid of computer device. The volume of frontal sinus was also evaluated. Results: At the age of more than 4, the pneumatization of frontal sinus was detected. Frontal sinus developed continuously and was observed in almost every children at the age of more than 17. The AP length, height, width and volume of frontal sinus were enlarged continuously until the age of 20. And the maximal growth of frontal sinus was observed at puberty. The width and volume of frontal sinus showed high correlation coefficient (r=0.8) relative to height or AP distance. Conclusion: The results of this study may be helpful in the comprehension of normal development of frontal sinus in Korean children.

The Usefulness of Three-Dimensional Imaging with Spiral CT for Evaluation of the Upper Airway Lesions (상부기도병변의 평가에 있어 나선식컴퓨터단층촬영술을 이용한 3차원적 영상의 유용성)

  • 김진환;김현웅;소상훈;노영수;임현준;윤대영
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.43-51
    • /
    • 1998
  • Background: Three-dementional imaging with spiral CT(3D spiral CT) is a well established imaging modality which has been investigated in various clinical settings. However the 3D spiral CT in upper airway disease is rarely reported and its results are still obscure. Objectives: To access the usefulness of 3D spiral CT imaging in patients with upper airway diseases. Materials and Methods We performed 3D spiral CT in fourteen patients In whom upper airway diseases were clinically suspected. Nine of these patients had upper airway stenosis, two had laryngeal cartilage fracture, and three had laryngo-hypopharyngeal cancer. For evaluation of location and extent of the lesions, we compared the findings of 3D imaging with those of air tracheogram, conventional 2D CT images, endoscopic and operative findings. Results: In case of stenosis, 3D spiral CT provide significant useful information, particularly the site and length of the stenotic segment. But, it was difficult to define the fracture of the laryngeal framework and to detect the cartilagenous invasion by head and neck cancer using the 3D imaging. Conclusion : The 3D spiral CT was an useful adjunctive method to assess some kind of upper airway disease but not in others. So, we should compare the findings of 3D images with those of other diagnostic tools for accurate diagnosis of the upper airway disease.

  • PDF

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.

A Study on Automatic Tooth Root Segmentation For Dental CT Images (자동 치아뿌리 영역 검출 알고리즘에 관한 연구)

  • Shin, Seunghwan;Kim, Yoonho
    • The Journal of Society for e-Business Studies
    • /
    • v.19 no.4
    • /
    • pp.45-60
    • /
    • 2014
  • Dentist can obtain 3D anatomical information without distortion and information loss by using dental Computed Tomography scan images on line, and also can make the preoperative plan of implant placement or orthodontics. It is essential to segment individual tooth for making an accurate diagnosis. However, it is very difficult to distinguish the difference in the brightness between the dental and adjacent area. Especially, the root of a tooth is very elusive to automatically identify in dental CT images because jawbone normally adjoins the tooth. In the paper, we propose a method of automatically tooth region segmentation, which can identify the root of a tooth clearly. This algorithm separate the tooth from dental CT scan images by using Seeded Region Growing method on dental crown and by using Level-set method on dental root respectively. By using the proposed method, the results can be acquired average 19.2% better accuracy, compared to the result of the previous methods.

Geometry of Resident's ridge with Multidetector-Row Computed Tomograph Image (다중검출기 컴퓨터 단층 영상 분석을 이용한 Resident's ridge의 형태학적 연구)

  • Roh, Jeong-Ho;Min, Byoung-Hyun;Park, Jeong-Wook;Ahn, Byung-Moon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.40-44
    • /
    • 2008
  • Purpose: The purpose of this study was to report the real geometry of Resident's ridge doing in anterior cruciate ligament reconstruction Materials and Methods: From Jan 2007 to Aug 2007, 48 cases which had normal distal femoral condyle analyzed with Multidetector-Row Computed Tomography. Resident's ridge was defined as change of height above 1 mm in lateral wall of intercondylar notch. Anterior-posterior length of intercondylar notch, length and height of Resident's ridge, distance of Resident's ridge from posterior cortex were estimated with 3-D reconstruction using $Lucion^{(R)}$ program. Results: Cases were $59{\pm}16$ years olds and male was 16 cases, female was 32 cases. 9 cases had no Resident's ridge, anterior-posterior length of intercondylar notch was $25.4{\pm}3.5$ mm, average of length and height of the Resident's ridge was $8.2{\pm}2.6,\;3.5{\pm}1.5$ mm. Distance of the Resident's ridge from posterior cortex was $7.6{\pm}2.6$ mm. Conclusion: Resident's ridge was used as landmark in anterior cruciate ligament reconstruction, which presented in many cases and which had distinct length and height.

  • PDF

Usefulness of Radiation Treatment Planning Applied Respiration Factor for Stereotactic Body Radiation Therapy in the Lung Cancer (폐암 환자의 정위체부방사선치료 시 호흡인자를 적용한 방사선 치료계획의 유용성)

  • Shin, Sung Pil;Kim, Tae-Hyung;So, Woon Young;Back, Geum Mun
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.587-593
    • /
    • 2016
  • We are evaluated the usefulness of radiation treatment planning applied respiration factor for stereotactic body radiation therapy in the lung cancer. Four dimensional computed tomography images were obtained in 10 patients with lung cancer. The radiation treatment plans were established total lung volume according to respiration images (new method) and conventional method. We was analyzed in the lung volume, radiation absorbed dose of lung and main organs (ribs, tracheobronchus, esophagus, spinal cord) around the tumor, respectively. We were confirmed that lung volume and radiation absorbed dose of lung and main organs around the tumor deference according to applied respiration. In conclusion, radiation treatment planning applied respiration factor seems to be useful for stereotactic body radiation therapy in the lung cancer.

Treatment of an Occipital Fracture by Esquillectomy (골편적출술을 적용한 후두골 골절 치료)

  • Park, Jin-Uk;Cho, Ki-Rae;Chang, Dong-Woo;Choi, Seok-Hwa;Kim, Gon-Hyung
    • Journal of Veterinary Clinics
    • /
    • v.27 no.4
    • /
    • pp.450-452
    • /
    • 2010
  • A 4-year-old male Yorkshire terrier was referred to us with signs of vomiting and unconsciousness due to a blunt head trauma. Gross examinations detected facial edema, subcutaneous hemorrhage and hypersalivation. A survey radiograph located an occipital fragment which was displaced caudally. A three-dimensional computed tomographic reconstruction demonstrated that the ventral portion of the fragment was attached incompletely. Because of the instability of the fragment, it was decided to perform an esquillectomy. After removing the fragment, the defect was reinforced with a muscular flap originating from the splenius muscle. The patient's condition gradually improved except for a slightly ataxic gait. At 20 months follow-up, there was no evidence of ataxia. The neurological status did not deteriorate before starting surgical intervention, although the patient sustained a skull fracture with severe intracranial hemorrhage. It is likely that the fragment being displaced outwardly played an important role in preventing an increase in intracranial pressure which could have led to neurological deterioration.

The 3-Dimensional Analysis of the Efficacy of a Belly-Board Device for the Displacement of Small Bowel During Pelvic Irradiation (골반강 방사선치료 중 소장의 이동을 위한 벨리보드의 효과에 대한 3차원적 분석)

  • Lee, Kyung-Ja
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.271-279
    • /
    • 2008
  • Purpose: To evaluate the efficacy of a belly-board device (BBD) in reducing the volume of small bowel during four-field pelvic irradiation. Materials and Methods: Twenty-two cancer patients (14 uterine cervical cancer, 6 rectal cancer, and 2 endometrial cancer) scheduled to receive pelvic irradiation were selected for this study. Two sets of CT images were taken with and without the belly-board device using the Siemens 16 channel CT scanner. All patients were set in the prone position. The CT images were transferred to a treatment planning system for dose calculation and volume measurements. The external surfaces of small bowel and the bladder were contoured on all CT scans and the 4-pelvic fields were added. The dose-volume-histogram of the bladder and small bowel, with and without the BBD, were plotted and analyzed. Results: In all patients, the total small bowel volume included in the irradiated fields was reduced when the BBD was used. The mean volume reduction was 35% (range, $1{\sim}79%$) and was statistically significant (p<0.001). The reduction in small bowel volume receiving $10{\sim}100%$ of the prescribed dose was statistically significant when the BBD was used in all cases. Almost no change in the total bladder volume involved was observed in the field (<8 cc, p=0.762). However, the bladder volume receiving 90% of the prescribed dose was 100% in 15/22 patients (68%) and $90{\sim}99%$ in 7/22 patients (32%) with the BBD. In comparison, the bladder volume receiving 90% of the prescribed dose was 100% in 10/22 patients (45%), $90{\sim}99%$ in 7/22 patients (32%), and $80{\sim}89%$ in 5/22 patients (23%) without the BBD. When the BBD was used, an increase in the bladder volume receiving a high dose range was observed Conclusion: This study shows that the use of a BBD for the treatment of cancer in the pelvic area significantly improves small bowel sparing. However, since the BBD pushed the bladder into the treatment field, the bladder volume receiving the high dose could increase. Therefore it is recommended to be considerate in using the BBD when bladder damage is of concern.

Evaluation of Micro-defects and Air Tightness of Al Die-casting by Impregnation of Organic Solvent (유기용제 함침법을 통한 알루미늄 다이캐스팅의 미세결함 및 기밀성 평가)

  • Lee, Jin-Wook;Cho, Chang-hyun;Kim, Sung-Gye;Ko, Young-Gun;Kim, Dong-Ju
    • Journal of Korea Foundry Society
    • /
    • v.42 no.4
    • /
    • pp.218-225
    • /
    • 2022
  • For hydrogen-vehicle applications (air pressure control valve housing, APCVH), an investigation was conducted to determine how micro-defects in a high- pressure die-casted Al alloy (industrial code: ALDC12) could be controlled by means of a post-treatment using an organic-based impregnation solution in order to improve the air- tightness of the die-casted Al sample. Two different impregnation solutions were proposed and its test results were compared to a imported product from Japan with respect to the processing variables used. A structural investigation of the components under study was conducted by means of computer tomography and 3D X-ray micro-CT. These observations revealed that the use of the impregnation treatment to seal micro-defects led to highly significant and beneficial changes which were attributed mainly to interconnections among inherent micro-pores. A leak test after impregnation revealed that the performance improvement rate of the die-casted Al sample was ~70% for INNO-01. Therefore, the developed impregnation solutions offer an effective strategy to control the micro-defects found in various vehicle parts via die-casting.

Finite Element Analysis of Stress Distribution in using Face Mask according to Traction Point (훼이스 마스크의 견인위치에 따른 응력분포에 관한 유한요소법적 연구)

  • Oh, Kyo-chang;Cha, Kyung-Suk;Chung, Dong-hwa
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.2
    • /
    • pp.171-181
    • /
    • 2009
  • The objective of this study was to analyse stress distribution of maxillary complex by use of face mask. The construction of the three-dimensional FEM model was based on the computed tomography(CT) scans of 13.5 years-old male subject. The CT image were digitized and converted to the finite element model by using the mimics program, with PATRAN. An anteriorly directed force of 500g was applied at the first premolar 45 degrees downwards to the FH plane and at the first molar 20 degrees downwards to the FH plane. When 45 degrees force was applied at maxillary first premolar, there were observed expansion at molar part and constriction at premolar part. The largest displacement was 0.00011mm in the x-axis. In the y-axis, anterior displacement observed generally 0.00030mm at maximum. In the z-axis, maxillary complex was displaced 0.00036 mm forward and downward. When 20 degrees force was applied at maxilla first molar, there were observed expansion at lateral nasal wall and constriction at molar part. The largest displacement was 0.001mm in the X-axis. In the Y-axis, anterior displacement observed generally 0.004mm at maximum. In the Z-axis, ANS was displaced upward and pterygoid complex was displaced downward. The largest displacement was 0.002mm.