• 제목/요약/키워드: 4/3 SRM

검색결과 123건 처리시간 0.02초

Determination of Chromium Content in Carbon Steel Pipe of NPP using ICP-AES

  • Choi, Kwang-Soon;Lee, Chang-Heon;Han, Sun-Ho;Park, Yong-Joon;Song, Kyu-Seok
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권12호
    • /
    • pp.4270-4274
    • /
    • 2011
  • A method is proposed for determining chromium content in the carbon steel pipes of a nuclear power plant (NPP) to evaluate wall thinning caused by flow-accelerated corrosion (FAC). A flat file was used to obtain filings samples. To assess sampling quality, a disk form of SRM 1227 was ground with the flat file, and the amount of Cr in the filings was determined by ICP-AES. The content of chromium in the filings of SRM 1227 was estimated as six times higher than the certified value due to the contamination of chromium in the file. To eliminate chromium contamination from the file, it was coated with WC-12Co using high-velocity oxygen-fuel (HVOF) spraying systems. After obtaining filings samples using the coated file, Cr content in four types of disk-form SRMs was determined by ICP-AES. The recoveries of Cr in the disk-form SRMs were in the range of 95.4-102.6%, with relative standard deviations from 0.43 to 3.0%. The Cr contents in the filings collected from the used outlet headers of the nuclear power plants using the flat file coated were in the range of 0.11-0.19%.

유도결합플라즈마-질량분석기(ICP-MS)를 이용한 토양의 총 우라늄 정량에 요구되는 적정 산분해 전처리 방법 개발 (Development of Appropriate Acid Digestion Method used for the Determination of Total Uranium in Soil by Inductively Coupled Plasma-Mass Spectrometer (ICP-MS))

  • 신건환;이군택;강지영;윤정기;김현구;노회정;김지인;김계훈
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제23권6호
    • /
    • pp.73-81
    • /
    • 2018
  • Inductively coupled plasma-mass spectrometry (ICP-MS), one of the most commonly used instruments for metal analysis, was used to determine total uranium in soil. The method was named as "Modified ASTM C1345-96". When comparing with ASTM C1345-96, digestion time (2~3 days) was shorten to 7 hours and the treatment in furnace was eliminated. In analyses of 26 field soil samples, there was a significant difference in the average concentration of total uranium between modified ASTM C1345-96 and ASTM C1345-96 (F : 6.22 > Fc : 4.03, significance level : 0.05, n=26). The average concentration of modified ASTM C1345-96 was 1.8 times larger than that of ASTM C1345-96. In addition, modified ASTM C1345-96 was compared with other acid digestion methods for soil including ISO 11466, Modified ISO 11466, US EPA-3051, US EPA-3051A and US EPA-3052 using a certificated reference material (SRM 2711a, NIST) and field soil samples with different level of organic matter content (1.6%, 5.8%, 10.6%). Modified ASTM C1345-96 showed the best accuracy of 93.01% for SRM 2711a. Also, modified ASTM C1345-96 showed the higher extraction rates than other digestion methods by 11~45%.

대전 도로변 먼지내 Platinum Group Elements의 분포 특성 (Distribution Characteristics of Platinum Group Elements in Roadside Dust from Daejeon, Korea)

  • 임종명;정진희;이진홍
    • 환경영향평가
    • /
    • 제27권5호
    • /
    • pp.405-416
    • /
    • 2018
  • 대기 중 입자상 물질에 대한 자동차 오염원의 지표원소로서 백금족 원소 (Platinum Group Elements, PGEs)에 대한 분석법의 유효성을 검증하고, 도로변 먼지 중 PGEs의 분포 특성을 평가하였다. 인증표준물질을 이용한 유효성 평가 결과, Pt, Pd, Rh의 상대오차는 각각 -0.7%, -10.0%, -20.4%이고 상대표준편차는 Pt, Pd, Rh 모두 10% 미만으로 반복 분석에 따른 재현성이 우수한 것으로 나타났다. 연구대상지역에서 채취한 도로변 먼지 시료 중 Pt, Pd, Rh의 농도는 각각 $17.4{\pm}9.2{\mu}g/kg$, $283.6{\pm}20.5{\mu}g/kg$, $7.3{\pm}2.8{\mu}g/kg$으로 Pd의 농도가 가장 높았다. Pt와 Rh의 농도는 배경지역이나 일반 도시지역의 토양 내 농도에 비해 지하주차장과 도로변 지역의 먼지에서 평균 농도가 상당히 높았고, 이러한 평균농도의 차이는 통계적으로 유의한 것으로 나타났다. 또한, 도로변 먼지에서의 PGEs의 농도 간 상관분석결과, Pd 보다는 Pt와 Rh가 자동차 오염원의 영향을 민감하게 반영하는 것으로 나타났다.

밥, 면, 소스류에 존재하는 수용성 비타민 B1, B2 그리고 B3 함량 검토 (Investigation of Water-Soluble Vitamin (B1, B2, and B3) Contents in Rice, Noodles, and Sauces)

  • 조진주;홍성준;부창국;신의철
    • 한국식품위생안전성학회지
    • /
    • 제35권4호
    • /
    • pp.398-410
    • /
    • 2020
  • 본 연구에서는 13종의 밥류, 11종의 면류, 그리고 15종의 소스류에 함유되어 있는 수용성 비타민 B1 (thiamin), B2 (riboflavin), 그리고 B3 (niacin)의 함량을 확인하였다. 실험 결과에 대한 신뢰도를 확인하기 위해 검출한계(LOD)와 정량한계(LOQ)를 확인하였으며, 표준인증물질(SRM 1849a)을 통한 결과의 정확도를 확인하여 우수한 지표를 나타내었다. Thiamin에서 밥류의 경우 잡채밥이 가장 높은 함유량을 확인하였고, 면류의 경우 막국수, 그리고 소스류의 경우 토마토 스파게티소스가 가장 높은 함유량을 확인하였다. Riboflavin은 밥류의 경우 짜장밥, 면류의 경우 비빔국수, 소스류의 경우 강황카레 약간 매운맛에서 가장 높은 함유량을 확인하였다. Niacin에서는 밥류, 면류, 그리고 소스류에서 각각 치킨볶음밥, 잔치국수, 짜장소스에서 가장 높은 함유량을 확인하였다. 한국인 성인 남녀의 수용성 비타민 1일 섭취권장량에 대하여 식품에 함유되어 있는 양을 확인한 결과 강황카레 약간 매운맛에서 가장 높은 riboflavin의 함량이 남자의 경우 217.40%, 여자의 경우 271.75%로 가장 높은 함량을 확인하였다. 본 연구를 통해서 밥류, 면류, 그리고 소스류에 함유된 수용성 비타민에 대한 영양성분 데이터베이스를 구축하고, 1일 섭취권장량에 대한 식품에 함유된 수용성 비타민의 함량 확인을 통해 국민 식생활에 필요한 자료를 제공하고자 한다.

A Low Cost Position Sensing Method with Optical Sensors for Switched Reluctance Motor

  • Yoon Yong-Ho;Jeong Kyun-Ha;Kim Jae-Moon;Won Chung-Yuen;Kim Ji-Won
    • Journal of Power Electronics
    • /
    • 제5권3호
    • /
    • pp.240-246
    • /
    • 2005
  • Considering the start-up and economical efficiency, the optical sensor technique using a slotted-disk and an opto-interrupter are appropriate, however, this method needs three opto-interrupters and a slotted-disk when driving the 6/4 pole SRM(switched reluctance motor). In this paper, we propose an economic method by replacing the conventional opto-interrupter and slotted-disk with only optical sensor which enables the motor to start up and forward and reverse operation. Also the control circuit includes only analog devices, which makes the process more economical.

Characteristic Analysis and Design of a Single Phase Switched Reluctance Motor for High Speed Application

  • Kim, Youn-Hyun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제4B권3호
    • /
    • pp.114-121
    • /
    • 2004
  • Switched reluctance motors have received much attention as a driving means for various industrial applications because they have simple construction, low cost and high efficiency. Nevertheless, the requirements of drive converters make it difficult to lower the overall system cost as compared with the DC motor application. Single phase switched reluctance motors (SPSRMs) provide a solution to the high cost problem since the number of switching power devices can be reduced and consequently the trials for application are increased. However, research involving SPSRMs, especially in the area of design work, is insufficient. This paper introduces a novel design methodology of single phase SRM. The design work for SPSRM comprises the determination of many variables such as stator and rotor pole arc as well as on, off and so on. Managing all variable combinations leads to lengthy computation time and a fault in the design process. For that reason, a reliable technique and brief procedure term are required in SPSRM design.

Hologram Based QSAR Analysis of Caspase-3 Inhibitors

  • Sathya., B
    • 통합자연과학논문집
    • /
    • 제11권2호
    • /
    • pp.93-100
    • /
    • 2018
  • Caspases, a family of cysteinyl aspartate-specific proteases plays a central role in the regulation and the execution of apoptotic cell death. Caspase-3 has been proven to be an effective target for reducing the amount of cellular and tissue damage because the activation of caspases-3 stimulates a signalling pathway that ultimately leads to the death of the cell. In this study, Hologram based Quantitative Structure Activity Relationship (HQSAR) models was generated on a series of Caspase-3 inhibitors named 3, 4-dihydropyrimidoindolones derivatives. The best HQSAR model was obtained using atoms, bonds, and hydrogen atoms (A/B/H) as fragment distinction parameter using hologram length 61 and 3 components with fragment size of minimum 5 and maximum 8. Significant cross-validated correlation coefficient ($q^2=0.684$) and non cross-validated correlation coefficients ($r^2=0.754$) were obtained. The model was then used to evaluate the eight external test compounds and its $r^2_{pred}$ was found to be 0.559. Contribution map show that presence of pyrrolidine sulfonamide ring and its bulkier substituent's makes big contributions for improving the biological activities of the compounds.

다검출기 유도결합 플라즈마 질량분석기에 의한 Sr 동위원소 분석을 위해 전처리된 시료의 최적 조건: Eichrom사 Sr 수지(SR-R50-S)와 Bio-Rad사 수지(AG®50W-X8) 비교 (Optimal Conditions for Pretreated Sample for Sr Isotope Analysis by MC-ICP-MS: A Comparison Between Eichrom (SR-R50-S)'s and Bio-Rad(AG®50W-X8)'s Resins)

  • 김명정;이승구
    • 광물과 암석
    • /
    • 제35권4호
    • /
    • pp.507-520
    • /
    • 2022
  • 지질과학 분야에서 암석의 생성 시기, 지각과 맨틀 진화연구의 기초자료로 활용되는 Sr 동위원소비는 열이온화 질량분석기(thermal ionization mass spectrometry, TIMS) 혹은 다검출기 유도결합 플라즈마 질량분석기(multi-collector plasma ionization mass spectrometry, MC-ICP-MS)와 같은 질량분석기를 이용하여 측정할 수 있다. 이 기술보고에서는, Sr 동위원소비 측정시, 원소의 불완전한 화학적 분리가 Sr 동위원소비의 참값 (true value)에 어떤 영향을 미치는지를 비교하였다. 실험에는 상업용 레진, NBS987(NIST SRM987) Sr 동위 원소 표준물질 그리고 일본지질조사소의 암석표준시료 JG1a, JB3, JA1를 이용하였다. 비교실험 결과, NBS987 Sr 동위원소 표준시료, 일본지질조사소의 암석표준시료 JG1a, JB3, JA1 모두 불완전한 분리에 의해 Rb이 남아있는 경우 87Sr/86Sr의 측정값이 변하는 것이 명확하게 관찰된다. 이는 질량분석기 특히 MC-ICP-MS로 동위 원소비를 측정하고자 하는 경우, 동종동위원소의 간섭에 대한 보정에도 불구하고 측정값은 참값에서 벗어나므로 완전한 분리가 중요한 인자임을 지시해준다. 그러므로 MC-ICP-MS를 이용한 Sr 동위원소비 측정결과를 보고할 때는, 동종동위원소에 의한 영향을 판단할 수 있도록 Sr의 동위원소 전체의 측정강도와 더불어 85Rb의 측정강도도 함께 보고돼야 할 것이다.

Analysis of Heterocyclic Amines in Human Urine Using Multiple Solid-Phase Extraction by Liquid Chromatography/Mass Spectrometry

  • Cha, Hyun-Jeong;Kim, Nam-Hee;Jeong, Eun-Kyung;Na, Yun-Cheol
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권8호
    • /
    • pp.2322-2328
    • /
    • 2010
  • A multiple solid-phase extraction (SPE) method was used with liquid chromatography, coupled with mass spectrometry (LC/MS), for the analysis of heterocyclic amines (HCAs) in human urine. Separation efficiencies based on the pH of the mobile phase and the types of columns were compared. An amide column showed better baseline separation and narrower HCA peak widths at pH 5.0 for the mobile phase than a $C_8$ column. Each SPE step, HLB, MCX, and HybridSPE, was optimized by controlling the pH conditions. The combined method with the three SPEs effectively removed interfering species that cause ion-suppression during HCA detection. Validation of the method, performed with SIM and SRM detection, showed correlation coefficients above 0.991 in the range 0.3 - 16.7 ng/mL. Recovery rates were 45.4 - 97.3% on the $C_8$ column and 71.8 - 101.4% on the amide column, and method detection limits were 0.11 - 0.65 ng/mL on the $C_8$ column and 0.12 - 0.48 ng/mL on the amide column. This method using multiple SPEs offers significant benefits for high-throughput determination of HCAs in urine.

반응셀 유도결합플라스마 질량분석분석기를 이용한 칼슘 동위원소비율의 측정과 동위원소희석법의 적용 (Application of Dynamic Reaction Cell - Inductively Coupled Plasma Mass Spectrometry for the Determination of Calcium by Isotope Dilution Method)

  • 서정기;임용현;황의진;이상학
    • 분석과학
    • /
    • 제15권5호
    • /
    • pp.417-426
    • /
    • 2002
  • 반응셀이 장치된 유도결합플라스마 사중극자 질량분석기를 이용하여 자연적으로 존재하는 6개의 칼슘 동위원소의 검출특성에 관한 연구를 수행하였다. 동적반응셀 (dynamic reaction cell, DRC)장치를 이용한 실험에서 최적의 신호 대 잡음비를 얻기 위한 실험조건을 조사하였다. 본 실험을 통해서 반응기체로서 0.7 mL/min의 $NH_3$를 사용하고 rejection parameter (RPq)값을 0.6으로 사용함으로써, Ca의 질량위치인 m/z 40, 42, 43, 44, 46 그리고 m/z 48의 위치에서 잠재적인 간섭이온인 $Ar^+$, ${CO_2}^+$, ${NO_2}^+$, $CNO^+$ 등이 효과적으로 제거됨을 확인하였다. 검출한계는 동위원소 $^{40}Ca$, $^{42}Ca$, $^{43}Ca$, $^{44}Ca$, 및 $^{48}Ca$에 대해서 각각 1, 29, 169, 34, and 15 pg/g으로 얻을 수 있었다. 이러한 실험조건 하에서 국제비교분석을 위해서 영국의 LGC (Laboratory of the Government Chemistry, Queens Road, Teddington, England)로부터 공급된 합성식품분해물질 중의 Ca을 동위원소희석법을 적용하여 분석하였다. 동위원소희석법에 의한 측정의 불확도는 ISO/GUM과 EURACHEM지침서에 따라 평가하였다. 측정된 시료중의 Ca의 농도와 불확도는 ($66.4{\pm}1.2$) mg/kg이었다. 또한 본 실험방법의 유효성을 확인하기 위해 농도가 인증된 표준시료 NRCC (National Research Council of Canada)의 SLRS-3 (riverine water CRM)과 NIST (National Institute of Science and Technology)의 SRM1643d (trace element in water)를 분석하였다.