• Title/Summary/Keyword: 3mm

Search Result 22,721, Processing Time 0.044 seconds

Spats Appearance and Distribution of Blood Cockle, Tegillarca granosa in Each Tidal Time and Line (노출선별 꼬막, Tegillarca granosa 치패의 출현과 분포)

  • Moon Tae-Seok;Jung Min-Min;Yang Moon-Ho;Wi Chong-Hwan;Lee Jung-Ho;Shin Yean-Sik;Shin Yun-Kyung;Chang Young-Jin
    • Journal of Aquaculture
    • /
    • v.19 no.2
    • /
    • pp.119-124
    • /
    • 2006
  • We investigated appearance tidal time and line of spats blood cockle, Tegillarca granosa. And we observed appearance individual numbers and shell growth of spats blood cockle, T. granosa on the several tidal lines and time for the highly valued aquaculture business. Most of the blood cockle spats distributed on the $2{\sim}3 $ hours tidal line. The shell growth was high on the $1{\sim}3$ hours tidal line. But we found small amount of spats on the $5{\sim}6$ hours tidal line. The shell length of spats became $4.7{\pm}1.0 mm$ in December, $5.2{\pm}1.2 mm$ in January, $5.4{\pm}0.9 mm$ in May, $8.5{\pm}0.8mm$ in June, $12.6{\pm}1.1 mm$ in July, $16.0{\pm}2.1 mm$ in August, $18.6{\pm}1.4 mm$ in September and $20.3{\pm}1.3 mm$ in October. As well, we could reconfirm of newly appearance blood cockle spats in the next October.

Characteristics of Ganoderma lucidum during short log cultivation with soil contact barrier treatment (영지버섯(Ganoderma lucidum) 단목재배시 토양접촉차단재 처리별 자실체 특성)

  • Kim, Minkyeong;Hwang, Jae Soon;Park, Jung-Hee;Shin, Yong seub;Jo, Woo-Sik
    • Journal of Mushroom
    • /
    • v.16 no.3
    • /
    • pp.231-235
    • /
    • 2018
  • Arthrographis cuboidea is a wood rot fungus found in soil. It causes disease in repeated cultivation areas of Ganoderma lucidum, which damage the mushroom logs and causes considerable loss of income to mushroom farmers. This study aimed to investigate the physicochemical properties of soil and characteristics of the growth environment such as the temperature of the Ganoderma lucidum cultivated land. The time required for primordia initiation was 12-13 days. In the chromaticity survey, the degree of redness (a) was 19.5 for vinyl, 20.2 for control, and 19.5 for nonwoven. The yellowness index (b) was 12.7 for vinyl, 13.3 for control, and 12.4 for nonwoven. In the study of growth characteristics, in case of no treatment (control), the length and thickness of the pileus were measured as 145.7 mm and 23.6 mm and those of the stipe were 73.9 mm and 11.5 mm, respectively, and the weight was 130 g. Treatment with non-woven fabric resulted in 157 mm and 93.3 mm long and 22.3 mm and 11.9 mm thick pileus and stipe, respectively, and the weight was 164 g. This result indicates that treatment with non-woven fabric is better than no treatment with respect to Ganoderma lucidum growth.

Effect of Sand Particle Sizes on Turf Vegetation of Creeping Bentgrass (모래입경이 Creeping Bentgrass 잔디 초지의 식생에 미치는 영향)

  • Park Sung-Jun;Cho Nam-Ki;Kang Young-Kil;Song Chang-Khil;Cho Young-Il
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.25 no.3
    • /
    • pp.205-210
    • /
    • 2005
  • This study was conducted from March 21 to July 9 in 2004 at JeJu Island to investigate the effect of different particle sizes (0.3-0.5, 0.5-0.8, 0.8-1.0, 1.0-1.5 and 1.5-2.0mm) on creeping bentgrass vegetation. The results obtained were summarized as follows; plant height became shorter as particle size was increased from 0.3-0.5 to 1.5-2.0 n. Root length, Minolta SPAD-502 chlorophyll reading value, leave and root weight were directly proportional plant height response. Degree of land cover and density of creeping bentgrass decreased as the particle size was increased from 0.3-0.5 to 1.5-2.0nm, and degree land cover and density of weed increased. The number of weed species were increased as the sand particle size was increased. Then ranking of the dominant weeds were Portulaca oleracea, Trifolium repens and Cyperus amuricus (at 0.3-0.5 and 0.5-0.8mm particle size), Trifolium repens, Portulaca oleracea and Polygonum hydropiper (at 0.8-1.0mm particle size), Portulaca oleracea, Polygonum hydropiper and Poa annua (at 1.5-2.0mm particle size). Based on the these findings, the optimum sand particle size for growth of creeping bentgrass seems to be about 0.3-0.5m in volcanic ash soils of Jeju island.

Quantitative Evaluation of the Accuracy of 3D Imaging with Multi-Detector Computed Tomography Using Human Skull Phantom (두개골 팬텀을 이용한 다검출기 CT 3차원 영상에서의 거리측정을 통한 정량적 영상특성 평가)

  • 김동욱;정해조;김새롬;유영일;김기덕;김희중
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.131-140
    • /
    • 2003
  • As the importance of accuracy in measurings of 3-D anatomical structures continues to be stressed, an objective and quantitative of assessing image quality and accuracy of 3-D volume-rendered images is required. The purpose of this study was to evaluate the quantitative accuracy of 3-D rendered images obtained with MDCT, scanned at various scanning parameters (scan modes, slice thicknesses and reconstruction slice thickness). Twelve clinically significant points that play an important role for the craniofacial bone in plastic surgery and dentistry were marked on the surface of a dry human skull. The direct distances between the reference points were defined as gold standards to assess the measuring errors of 3-D images. Then, we scanned the specimen with acquisition parameters of 300 mA, In kVp, and 1.0 sec scan time in axial and helical scan modes (pitch 3:1 and 6:1) at 1,25 mm, 2.50 mm, 3.75 mm and 5.00 mm slice thicknesses. We performed 3-D visualizations and distance measurements with volumetric analysis software and statistically evaluated the quantitative accuracy of distance measurements. The accuracy of distance measurements on the 3-D images acquired with 1.25, 2.50, 3,75 and 5.00 mm slice thickness were 48%, 33%, 23%, 14%, respectively, and those of the reconstructed 1.25 mm were 53%, 41%, 43%, 36% respectively. Meanwhile, there were insignificant statistical differences (P-value<0.05) in the accuracy of the distance measurements of 3-D images reconstructed with 1.25 mm thickness. In conclusion, slice thickness, rather than scan mode, influenced the quantitative accuracy of distance measurements in 3-D rendered images with MDCT. The quantitative analysis of distance measurements may be a useful tool for evaluating the accuracy of 3-D rendered images used in diagnosis, surgical planning, and radiotherapeutic treatment.

  • PDF

The Clinical Analysis of Modified B-T Shunt Using 3 mm and 3.5 mm PTFE graft (3mm와 3.5mm PTFF graft를 이용한 변형 B-T 단락술의 임상적 분석)

  • 정성호;윤태진;임한중;민경석;서동만;윤소영;김영휘;고재곤;박인숙
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.716-722
    • /
    • 2000
  • Background: Modified Blalock-Taussig shunt using 3mm or 3.5mm PTFE graft has been performed in patients with small body weight or in candidates for single ventricle palliation. However, there are few reports concerning clinical outcomes in terms of pulmonary artery growth and shunt patency rate after shunt operations using such a small graft. Material and Method: Twenty-five patients rate after shunt operations using 3 or 3.5 mm sized grafts from September 1996 to August 1999. We retrospectively assessed the pulmonary artery growth and the shunt patency rate by reviewing the pre-and post-operative pulmonary angiograms. The risk factors for late death and second shunt operations were also analyzed. To assess the presence of any correlation between body weight and selection of the graft size, regression analysis was done in 81 cases of shunt operations performed during the same period. Result: There were 1(4%) early death and 5(20%) late deaths. The survivors were followed up for an average of 7.34 months. The pulmonary artery index increased significantly from 129$\pm$66$\textrm{mm}^2$/$m^2$ to 213$\pm$114 $\textrm{mm}^2$/$m^2$(p=0.002). The shunt patency rate assessed at postoperative 2, 4, 6 and 8 months were 82.5%, 77%, 73% and 42% respectively with a marked decline between 6 and 8 months. Asplenia was a frequent finding for the patients with late death although the incidence failed to reach statistical significance(p=0.078). Pre-operative diagnosis of PA with VSD was found to be a statistically significant risk factor for a second shunt operation(p=0.01). Body weight(a) at operation and graft size(b) used in the shunt operations revealed strong correlation and could be expressed by the following formula; b=0.128a + 3.233. Conclusion: Adequate growth of pulmonary artery and satisfactory early patency rate could be obtained by modified Blalock-Taussing shunt using 3mm or 3.5mm graft. However, during 6 to 8 months after shunt operations, the patency rate fell sharply, which implicates that close observation and early intervention are mandatory in this period.

  • PDF

Descriptions of Four New Species of Predatory Nematodes (Mononchida) From Korea (韓國産 捕食線蟲(Mononchida: Nematoda)의 4 新種 기재)

  • Choi, Young-Eoun;Khan, Zakaullah;Lee, Sung-Min
    • The Korean Journal of Soil Zoology
    • /
    • v.4 no.2
    • /
    • pp.89-100
    • /
    • 1999
  • Four new and a known spacies of the order Mononchida were described and illustrated. Iotonchus obtusus sp. n. was 2.8 mm long, a=33, b=4.2, c=61, V=68%, buccal cavity=61${\times}$45 mm, and is characterized by having basally situated dorsal tooth, presence of vulval papillae and in having short, hemispherical tail with thick cuticle at terminus. Miconchus vulvapapillatum sp. . was 2.7-3.6 mm long, a=29-36, b=4.1-4.5, c=18.4-21, V=65-69%, buccal cavity=53-61${\times}$29-33 mm, spicules=132-137 mm, ventromedian supplements 28-31, and was characterized by having 5-8 pre- and post vulval papillae in contiguous series, and three pairs of vulval glands. Clarkus koreanus sp. n. was 1.1-1.3 mm long, a=27.5-28.8, b=3.5-3.9, c=12-14.5, V=60-64%, buccal cavity=24-28${\times}$13.5-15 mm, and was characterized by well offset lip region, amphids situated well below to dorsal tooth apex, and vulva elevated, with vulval flap. Coomansus ulsani sp. n. was 1.2-1.5 mm long, a=23.5-26, b=3.4-3.8, c=13.6-14.8, V=65-68%, buccal cavity=36-39${\times}$21-23 mm and was characterized by well offset lip region and a thin longitudinal ridge on vertical walls of stoma.

  • PDF

Second Harmonic Generation of Low Power Laser Diode Using a Ring Enhancement Cavity (고리형 Enhancement Cavity 를 이용한 저출력 반도체 레이저의 제2조화파 발생)

  • 오차환
    • Korean Journal of Optics and Photonics
    • /
    • v.4 no.2
    • /
    • pp.206-211
    • /
    • 1993
  • We carried out the second harmonic generation of low power CW laser diode with maximum power of 30 mW in $LilO_3$ crystals. We used a ring enhancement cavity to increase the second harmonic conversion efficiency. The ring enhancement cavity was Composed of two flat mirrors and two concave mirrors. The focal length of concave mirrors was 25 mm, and 5 mm long and 10 mm long $LilO_3$ crystals were used. We measured the second harmonic power according to the pumping power and compared with theoretical value. We obtained 397 nm second harmonic power of about $6.6{\mu}W$ in 10 mm long $LilO_3$ crystal with the fundumental 794 nm pumping power of 28 mW.

  • PDF

Effect of wire diameters on superconducting and mechanical properties of internal tin processed $Nb_{3}$ Sn wires (내부 확산법으로 제조한 $Nb_{3}$ Sn초전도선의 세선화에 의한 유연성 조사)

  • 하동우;오상수;이남진;하홍수;권영길;류강식;백홍구
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.29-32
    • /
    • 2001
  • Internal tin processed Nb$_3$Sn wires of intermediated worked state of were took from Mitsubishi and fabricated with various diameters ranging from 0.76 mm to 0.2 mm. These specimens were heat-treated at $460^{\circ}C$ for 70 h and at $570^{\circ}C$ for 100h to form bronze and at $700^{\circ}C$ for 100h to form Nb$_3$Sn compound. Bending strain Ic s of the wires were measured with various bending diameters ranging from flat to 76 mm. In order to investigate the sensitivity for strain, small diameters of wires were strain Ic at 6 T, 4.2 K. There were no breakage decrease during cold working to 0.2 mm of diameter and no decrease Jc to the diameter of 0.3 mm. The values of bending strain Ic of 0.2 mm and 0.3 mm diameters of the wires were not decreased at 76 mm of bending diameter.

  • PDF

Analyses of Mesh Selectivity in Trawl Cod - end for Priacanthus macracanthus (홍치에 대한 트롤 끝자루의 망목선택성 분석)

  • Kim, Sam-Kon;Youm, Mal-Gu;Park, Chang-Doo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.8 no.1
    • /
    • pp.41-47
    • /
    • 1996
  • The fishing experiment was carried out in order to analyses the mesh selectivity for trawl cod - end in the Southern Korean Sea and East China Sea from June,1991 through December, 1992. The mesh selectivity was examined for the five kinds with opening mesh size, of which having mesh s izes 51.2mm, 70.2mm, 77.6mm, 88.0mm and 111.2mm. In this report, mesh selectivity were taken analyses trawl cod - end for Priacanthus macracanthus. The main results obtained were as follows : 1. The relation equations between total length(TL) and body height(BH), body girth(BG) and body weight(BW) were BH=0.256 TL+2.963, BG=0.620 TL+8.650 and $BW=7.34{\times}10^{-5}TL^{2.6956}$, respectively. 2. 50% selection length and selection factor of trial cod - end with opening mesh size having 51.2mm, 70.2mm, 77.6mm, 88.0mm were 94.8mm, 1.85 ; 159mm, 2.27 ; 204mm, 2.09 ; 217.3mm, 2.18, respectively. 3. Range of opening mesh size from 51.2mm to 88.0mm, parameters of master curve were slope 2.70, intercept - 5.7 and selection factor 2.11.

  • PDF

A Study on the Lead(Pb) Shield Thickness per Electron Beam Energy in Radiotherapy (방사선 치료용 전자선의 에너지별 납(Pb) 차폐체 두께 측정)

  • Gha-Jung, Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.6
    • /
    • pp.719-725
    • /
    • 2022
  • This study aimed to measure, quantitatively evaluate, and set the criteria for the minimum lead(Pb) shield thickness per level of clinically applied electron beam energy. The lead shield thickness per electron beam energy was measured using the primary field 95% reduction based on the open field at the depth of maximum dose (dmax) and depth from the surface as the reference depth of tissue dose(10 mm). The measured values were 1.906 mmPb and 1.992 mmPb at the dmax and 10 mm, respectively, regarding the lead shield thickness for 6 MeV electron beam; 2.746 mmPb and 3.743 mmPb for 9 MeV electron beam, 3.718 mmPb and 6.093 mmPb for 12 MeV electron beam, 7.300 mmPb and 15.270 mmPb for 16 MeV electron beam, and 16.825 mmPb and 25.090 mmPb for 20 MeV electron beam. Consequently, a thicker lead shield was required if the measurement was at 10 mm. The required lead shield thickness was also higher than that of the theoretical formula for electron beams of ≥ 16 MeV.