• Title/Summary/Keyword: 3D-scan data

Search Result 394, Processing Time 0.032 seconds

Analysis of Breast Shapes through the Utilization of 3D Scan Data: A Focus on Women in the Early to Late 30s (3차원 데이터를 활용한 유방유형별 형태 분석: 30대 여성을 중심으로)

  • Kim, Ji Min;Kim, Hyo Sook
    • Human Ecology Research
    • /
    • v.52 no.5
    • /
    • pp.509-518
    • /
    • 2014
  • This study strives to analyze the characteristics of and changes in breast shapes of women in their 30s, whose bodies start to age and whose breasts experience changes due to internal and external factors such as pregnancy, childbearing, and breast-feeding. The analysis of the indirect breast measurements for each age group (early, mid, and late 30s) demonstrates that the volume of the breasts increases proportionally with age, the breasts lose their firmness, and the nipples start to point downwards rather than to the sides. The breast shapes experience more significant changes vertically than horizontally as the breasts start to sag downwards. The composition factors of the breasts have been classified into five factors: the level of volume in the breasts and the surrounding area, the degree of sagging in the breasts, the position and vertical width of the breasts, the volume of the breasts, and the degree of width between the breasts. The breasts have been categorized into three different shapes. Breast Shape I (32.56%) appeared most frequently among women in their mid 30s, and this shape falls into the category of Sagging I, which is one of the six breast types that have been classified by the Japanese Wacoal Research Center, in addition to Korean size 80A. Breast Shape II (38.76%) appeared most frequently among women in their mid 30s, and this shape has been categorized as flat with its size being 70A. Breast Shape III (28.68%) appeared most frequently among women in their early 30s with a conical shape and size 75A.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

The Measurement of Flight Data of Golfball with High-Speed Multi-Exposure Image (고속 다중 노출 영상을 이용한 골프공의 비행 요소 측정)

  • Kim, Ki-Hyun;Park, Hyun-Woo;Ju, Woo-Suk;Lee, Dong-Hoon;Yun, Tae-Soo
    • Journal of Korea Multimedia Society
    • /
    • v.12 no.5
    • /
    • pp.699-707
    • /
    • 2009
  • Recently, while 3D sports game increases, the research that it recognizes the operation of the real user actively progresses. Most of all, the research about the golf is active. In this paper, the camera acquiring in a high-speed multi-exposure image measures the flight data of the golf ball through the image processing. While photographing, the high-speed camera, using this system, exposes an image at regular intervals. And line scan camera checks whether the golf ball passed or not. After the location information of the calculated golf ball calculates a speed and a direction by using the physical formula, it applies the golf simulation. After, this system is possible the measurement of the physical element of the spherical object.

  • PDF

Application of Lower Body Girth Change Analysis Using 3D Body Scanning to Pants Patterns

  • Choi, Sun-Yoon;Ashdown, Susan P.
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.6
    • /
    • pp.955-968
    • /
    • 2010
  • Three-dimensional body data has been used in many industry fields including the apparel industry. This research used data from a study of the changes in lower body girth measurements from a 3D scan study of 25 female subjects aged 18 to 24 in four postures; a standing posture, a $120^{\circ}$ knee bend posture, a one pace stepping posture, and a sitting posture with a $90^{\circ}$ knee bend. We used the information on the difference between standing and seated measurements to adjust ease values for pants patterns an evaluation of the appearance, and the comfort of the pants. Waist girth in the sitting posture increased 8% compared to a standing posture and the hip girth measurement increased 7%. A basic pants pattern (pants A) with 2.4cm ease at the waist and 2.6cm ease at the hip was developed and a pants pattern (pants B) was developed using the rates of lower body girth change with a 5.7cm ease (8% change) at the waist and 7cm ease (7% change) at the hip. The appearance assessment items of pants A in a standing posture were higher than pants B. On the other hand, most appearance assessment items of pants B in a sitting posture were higher than pants A, especially the ease of pants back waistline and the appearance of the whole back. Comfort assessment items of pants B in both standing and sitting postures were higher than the comfort assessment items for pants A, especially the location of pants waistline, the ease of pants at the waistline, and the ease at the abdomen. In order to find the best level of ease for better appearance and comfort in both standing and sitting postures, 20 pants were constructed with ease values at the waist and hip in increments of 1.1cm in the range between the ease values of pants A and pants B. A fit test was conducted to compare the average appearance and comfort ratings that identified the pants with the best ease values at the waist and hip. The highest total mean was achieved in the pants with a waist ease of 4.6cm and hip ease of 4.8cm.

Anthropometric Analysis of Facial Foramina in Korean Population: A Three-Dimensional Computed Tomographic Study

  • Lim, Jung-Soo;Min, Kyung-Hee;Lee, Jong-Hun;Lee, Hye-Kyung;Hong, Sung-Hee
    • Archives of Craniofacial Surgery
    • /
    • v.17 no.1
    • /
    • pp.9-13
    • /
    • 2016
  • Background: Position of the facial foramina is important for regional block and for various maxillofacial surgical procedures. In this study, we report on anthropometry and morphology of these foramina using three-dimensional computed tomography (3D-CT) data. Methods: A retrospective review was performed for all patients who have undergone 3D-CT scan of the facial skeleton for reasons other than fracture or deformity of the facial skeleton. Anthropometry of the supraorbital, infraorbital, and mental foramina (SOF, IOF, MF) were described in relation to facial midline, inferior orbital margin, and inferior mandibular margin (FM, IOM, IMM). This data was analyzed according to sex and age. Additionally, infraorbital and mental foramen were classified into 5 positions based on the anatomic relationships to the nearest perpendicular dentition. Results: The review identified 137 patients meeting study criteria. Supraorbital foramina was more often in the shape of a foramen (62%) than that of a notch (38%). The supraorbital, infraorbital, and mental foramina were located 33.7 mm, 37.1 mm, and 33.7 mm away from the midline. The mean vertical distance between IOF and IOM was 13.4 mm. The mean distance between MF and IMM was 21.0 mm. The IOF and MF most commonly coincided with upper and lower second premolar dentition, respectively. Between the sex, the distance between MF and IMM was significantly higher for males than for female. In a correlation analysis, SOF-FM, IOF-FM and MF-FM values were significantly increased with age, but IOF-IOM values were significantly decreased with age. Conclusion: In the current study, we have reported anthropometric data concerning facial foramina in the Korean population, using a large-scale data analysis of three-dimensional computed tomography of facial skeletons. The correlations made respect to patient sex and age will provide help to operating surgeons when considering nerve blocks and periosteal dissections around the facial foramina.

A Study of Roughness Measurement of Rock Discontinuities Using a Confocal Laser Scanning Microscope (콘포컬 레이저 현미경을 이용한 불연속면의 거칠기 측정 연구)

  • Byung Gon Chae;Jae Yong Song;Gyo Cheol Jeong
    • The Journal of Engineering Geology
    • /
    • v.12 no.4
    • /
    • pp.405-419
    • /
    • 2002
  • Fracture roughness of rock specimens is observed by a new confocal laser scanning microscope (CLSM; Olympus OLS1100). The wave length of laser is 488 nm, and the laser scanning is managed by a light polarization method using two galvano-meter scanner mirrors. The function of laser reflection auto-focusing enables us to measure line data fast and precisely. The system improves resolution in the light axis (namely z) direction because of the confocal optics. Using the CLSM, it is Possible to measure a specimen of the size up to $10{\;}{\times}{\;}10{\;}cm$ which is fixed on a specially designed stage. A sampling is managed in a spacing $2.5{\;}\mu\textrm{m}$ along x and y directions. The highest measurement resolution of z direction is $10{\;}\mu\textrm{m}$, which is more accurate than other methods. Core specimens of coarse and fine grained granite are provided. Fractures are artificially maneuvered by a Brazilian test method. Measurements are performed along three scan lines on each fracture surface. The measured data are represented as 2-D and 3-D digital images showing detailed features of roughness. Line profiles of the coarse granites represent more frequent change of undulation than those of the fine granite. Spectral analyses by the fast Fourier transform (FFT) are performed to characterize the roughness data quantitatively and to identify influential frequency of roughness. The FFT results suggest that a specimen loaded by large and low frequency energy tends to have high values of undulation change and large wave length of fracture roughness.

The Correlation Study of the Occurrence of Blooming Artifact according to Dilution Ratio of Contrast Media in CT Angiography (CT Angiography 영상에서 조영제 희석비율에 따른 Blooming Artifact 발생의 상관성 연구)

  • Lee, Su-Seong;Baek, Se-Jun;Seok, Jeong-Yeon;Ryu, Dae-Yeon;Kim, Seong-Jin;Heo, Yeong-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.1
    • /
    • pp.61-68
    • /
    • 2020
  • The purpose of this study is to investigate the correlation of blooming artifacts according to dilution ratio of contrast agent on CT angiography images. A total of 10 sets were prepared by differently setting the ratio of contrast media and saline in a ball phantom made by a 3D printer. CT scan images were obtained and reconstructed by MIP and MPR techniques to obtain axial, sagittal and coronal images, respectively. After, the diameter of the ball phantom of the image obtained after the test was measured each 30 times, a total 1800 times. As a result, the dilution of 20:80 in the coronal plane was the smallest (p<0.05). Similarly, when dilute to 20:80 in the sagittal plane of MIP, it was the smallest as 20.39 ± 0.08 mm (p<0.05). Correlation analysis between dilution ratio and measurement size confirmed strong negative correlations in all reconstructed images (p<0.05). In conclusion, the higher the dilution ratio of the contrast agent, the more difficult it is to measure actual blood vessel measurement. Therefore, this study may provide basic data in future studies on actual measurement.

A LiDAR-based Visual Sensor System for Automatic Mooring of a Ship (선박 자동계류를 위한 LiDAR기반 시각센서 시스템 개발)

  • Kim, Jin-Man;Nam, Taek-Kun;Kim, Heon-Hui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.6
    • /
    • pp.1036-1043
    • /
    • 2022
  • This paper discusses about the development of a visual sensor that can be installed in an automatic mooring device to detect the berthing condition of a vessel. Despite controlling the ship's speed and confirming its location to prevent accidents while berthing a vessel, ship collision occurs at the pier every year, causing great economic and environmental damage. Therefore, it is important to develop a visual system that can quickly obtain the information on the speed and location of the vessel to ensure safety of the berthing vessel. In this study, a visual sensor was developed to observe a ship through an image while berthing, and to properly check the ship's status according to the surrounding environment. To obtain the adequacy of the visual sensor to be developed, the sensor characteristics were analyzed in terms of information provided from the existing sensors, that is, detection range, real-timeness, accuracy, and precision. Based on these analysis data, we developed a 3D visual module that can acquire information on objects in real time by conducting conceptual designs of LiDAR (Light Detection And Ranging) type 3D visual system, driving mechanism, and position and force controller for motion tilting system. Finally, performance evaluation of the control system and scan speed test were executed, and the effectiveness of the developed system was confirmed through experiments.

The Occurrence of Renal Scarring in Children with Unilateral Vesicoureteral Reflux (일측성 방광 요관 역류 환아에서 신반흔의 발생)

  • Lee, Tae Ho;Son, Mi Ran;Byun, Soon Ok;Moon, Jung Woong
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.998-1003
    • /
    • 2005
  • Purpose : We evaluated the occurrence of renal scarring in children with unilateral vesicoureteral reflux(VUR), and the relationships between renal scar formation and risk factors such as VUR, duration of fever, acute-phase reactant, age, and sex. Methods : We retrospectively analyzed the data of 35 children newly diagnosed with unilateral vesicoureteral reflux after urinary tract infection(UTI) in Wallace Memorial Baptist Hospital between January 1996 and December 2004. Ultrasonography, Erythrocyte sedimentation rate(ESR), and C-reactive protein(CRP) were performed initially. Voiding cystourethrography(VCUG) was performed 1 to 3 weeks after treatment with UTI. $^{99m}Tc$-dimercaptosuccinic acid(DMSA) scan was performed 4 to 6 months after treatment. Results : Scintigraphic renal damage was present in 29 percent of the refluxing and in 3 percent of the nonrefluxing kidneys(P<0.05). The severity of VUR was significantly correlated with renal scar formation(P<0.05). The duration of fever before treatmen($5.0{\pm}1.3$ vs $2.6{\pm}1.3$) and prolonged fever of over 5 days were significantly different between renal scar group and non-renal scar group(P<0.05). ESR($56.3{\pm}23.8$ vs $27.9{\pm}18.1mm/hr$, P<0.05) and CRP($12.8{\pm}7.3$ vs $3.9{\pm}3.8mg/dL$, P<0.05) at the diagnosis of UTI in the renal scar group were higher, compared to those of the non-renal scar group. There were no significant differences in age and sex between the two groups. Conclusion : The presence and grade of VUR, the duration of fever before treatment, prolonged fever over 5 days, ESR, and CRP were risk factors for renal scarring, irrespective of age and sex. Diagnosis and management of VUR, in children with UTI, is important to prevent renal scars.

A Study of Pattern Making for Coverall Work Clothing Using Dynamic Wearing Ease (활동여유량을 적용한 커버롤 작업복 패턴 제작 방법 연구)

  • Oh, Seol-Young;Chun, Jong-Suk;Shin, Se-Mi;Lee, Min-Ji
    • Journal of the Korean Home Economics Association
    • /
    • v.49 no.3
    • /
    • pp.113-121
    • /
    • 2011
  • This study developed a method of calculating dynamic wearing ease (DWE) to make patterns for coverall work clothing. The DWE was measured from 3D body scan data of women in their 20's (n = 10). The body postures adopted for measuring the DWE were sitting and deep bending postures. Three types of experimental patterns (A, B, C) were developed. The DWE was applied at the waist and hip lines of the pattern. The location and size of the DWE varied from one pattern to another. For pattern B, DWE of 8.8cm was applied at the back of the waistline. For pattern C, 5.3cm was applied at the waist for the center back line, and 3.5cm was applied at the under hip level. The comfort of the experimental clothing was evaluated in six body postures. The results showed that patterns B and C were comfortable at the crotch, shoulders, and arm pits. Pattern C was comfortable at the hip and crotch areas in the arms lifting-up posture and the stepping-up posture. The appearance and fit of the experimental clothing were evaluated by the panels. Patterns B and C fitted better than pattern A at the abdomen. The results suggest that DWE should be applied at the waist and hip levels for making coverall work clothing patterns.