• Title/Summary/Keyword: 3D-Scanning

Search Result 1,479, Processing Time 0.038 seconds

Study on 3D Reverse Engineering-based MEP Facility Management Improvement Method (3차원 역설계 기반 MEP 시설물 관리 작업 개선 방안 도출)

  • Kang, Tae-Wook;Kim, Ji-Eum;Jung, Taek-Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.8
    • /
    • pp.38-45
    • /
    • 2016
  • The objective of this research is to develop a method of improving MEP facility management based on 3D reverse engineering. Recently, 3D image scanning-based reverse engineering has been implemented in the fields of architecture, construction and (manufacturing). In the case where there are many objects and the MEP system is complicated, 3D reverse engineering is applied in semiconductor factories, because facility maintenance works cause the 2D drawing to be different from the original one. The 3D point cloud data obtained from 3D image scanning contains accurate data and can increase the efficiency of complicated MEP facility maintenance works. For this purpose, the present research studied the technology trends and analyzed the process of 3D reverse engineering. Based on the results, a method of improving MEP facility management is established and its effects described.

Development of Digital 3D Real Object Duplication System and Process Technology (디지털 3차원 실물복제기 시스템 및 공정기술 개발)

  • Lee Won-Hee;Ahn Young-Jin;Jang Min-Ho;Choi Kyung-Hyun;Kim Dong-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.4 s.181
    • /
    • pp.183-190
    • /
    • 2006
  • Digital 3D Real Object Duplication System (RODS) consists of 3D Scanner and Solid Freeform Fabrication System (SFFS). It is a device to make three-dimensional objects directly from the drawing or the scanning data. In this research, we developed an office type SFFS based on Three Dimensional Printing Process and an industrial SFFS using Dual Laser. An office type SFFS applied sliding mode control with sliding perturbation observer (SMCSPO) algorithm for control of this system. And we measured process variables about droplet diameter measurement and powder bed formation etc. through experiments. In case of industrial type SFFS, in order to develop more elaborate and speedy system for large objects than existing SLS process, this study applies a new Selective Dual-Laser Sintering (SDLS) process and 3-axis Dynamic Focusing Scanner for scanning large area instead of the existing f lens. In this process, the temperature has a great influence on sintering of the polymer. Also the laser parameters are considered like that laser beam power, scan speed, and scan spacing. Now, this study is in progress to evaluate the effect of experimental parameters on the sintering process.

Arrhenius Kinetic Constants Analysis of BKNO3 under Accelerated Aging (가속노화에 따른 BKNO3의 아레니우스 동역학 상수 분석)

  • Jang, Seung-gyo;Kim, Jun-hyung;Ryu, Byung-tae;Hwang, Jung-min
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.4
    • /
    • pp.34-39
    • /
    • 2016
  • Arrhenius kinetic constants, the activation energy and the pre-exponential factor, of energetic material $BKNO_3$ are estimated using Differential Scanning Calorimetry (DSC). Different from the conventional way, the activation energy was estimated more precisely through DSC aging trial, and the consumed fraction by heat was calculated by comparing the integration of heat flow. We suggested the condition of accelerated aging test for the energetic material $BKNO_3$ and reconsidered the meaning of the thermal accelerated aging.

3-D Imaging in a Chaotic Micromixer Using Confocal Laser Scanning Microscopy (CLSM) (공초점 현미경을 이용한 마이크로믹서 내부의 3차원 이미지화)

  • Kim, Hyun-Dong;Kim, Kyung-Chun
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2006.12a
    • /
    • pp.96-101
    • /
    • 2006
  • 3-D visualization using confocal laser scanning microscopy (CLSM) in a chaotic micromixer was performed as a reproduction experiment and the feasibility of 3-0 imaging technique in the microscale was confirmed. For diagonal micromixer (DM) and two types of staggered herringbone micromixers (SHM) designed by Whitesides et al., to verify the evolution of mixing, cross sectional images are reconstructed at the end of every cycle. In a DM, clockwise rotational flow motion generated by diagonal ridges placed on the floor of micromixer is observed and this motion makes the fluid commingle. On the contrary, there are two rotational flow structures in the SHM and the centers of rotation exchange their position each other every half cycle because of the V shape of ridges varying their orientation every half cycle. Local rotational flow and local extensional flow generated by the complicate ridge pattern make the flow be chaotic and accelerate the mixing of fluid. The dominant parameter that influences on the mixing characteristic of SHM is not the length of micromixer but the number of ridges under the same flow configurations.

  • PDF

3D Printing Characteristics of Automotive Hub using 3D Scanner and Reverse Engineering (3D 스캐너와 역설계를 활용한 자동차용 허브의 프린팅 특성)

  • Kim, Hae-Ji
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.10
    • /
    • pp.104-109
    • /
    • 2019
  • Reverse engineering techniques using 3D scanners and 3D printing technologies are being used in various industries. In this paper, the three-dimensional model is designed for automotive hub parts through 3D scanning and reverse engineering, and the design of hub parts is intended to be printed on FDM-style 3D printers to measure and analyze the dimensions of hub parts designed for reverse design and 3D printed hub parts. Experimental result have shown that the dimensions of 3D printed hub parts are small compared to those of the reverse-engineered dimensions, which are due to the shrinkage of filament materials in 3D printing.

Three Dimensional Confocal Imaging and Biomedical Image Analysis (3차원 Confocal Imaging과 생체 영상 분석)

  • Lee, Yim-Kul
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1995 no.11
    • /
    • pp.257-261
    • /
    • 1995
  • Confocal laser scanning microscopy (CLSM)는 기존의 coherent or incoherent microscopic imaging 보다 횡축 방향 (lateral direction)으로 고해상도를 가지며, 층과 층 사이를 구분하는 광축 방향 (axial direction)의 optical sectioning에 의해 샘플의 3D 구조를 고해상도로 영상화함으로써 3D 구조 및 생체 기능 분석을 가능하게 해 준다. 본 논문에서는 CLSM에 의한 3D 영상화 원리와 촛점면 부근에서 얻어지는 광세기 분포, 얻어진 2D slice 영상의 시각화 및 응용에 대해 논의된다.

  • PDF

Measurement and Scale Effects of Digitized Virtual Human Head

  • Takakazu, Ishimatsu;Chan, Tony
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.89.1-89
    • /
    • 2001
  • Measurement of complex surfaces without touching is desirable in several fields. This arises mainly for measurement of complex surfaces including those surfaces that deform during touch. Our research presented in this paper describes the use of a 3D digitizer for scanning 3D objects. The use of such a device, in addition to proper calibration, requires proper scaling in all three dimensions. We propose measurement techniques to measure various aspects of the surface circumference, area and volume. We also present experiments from using a 3D Minolta digitizer for measuring 3D human heads.

  • PDF

Evaluation of repeated measurement stability of dentition type of maxillary anterior tooth: an in vitro study (상악 전치의 치열 형태에 따른 스캔 반복 측정 안정성 평가: in vitro 연구)

  • Park, Dong-In;Son, Ho-Jung;Kim, Woong-Chul;Kim, Ji-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.41 no.3
    • /
    • pp.211-217
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate the repeated measurement stability of scans related to dentition type. Methods: A normal model and the crowding and diastema models are also duplicated using duplicating silicon. After that, a plaster model is made using a plaster-type plaster on the duplicate mold, and each model is scanned 5 times by using an extraoral scanner. The gingival part and molar part were deleted from the 3D STL file data obtained through scanning. Using the 3D stl file obtained in this way, data is nested between model groups. Thereafter, RMS values obtained were compared and evaluated. The normality test of the data was performed for the statistical application of repeated measurements with dentition type, and the normality was satisfied. Therefore, the one-way ANOVA test, which is a parametric statistical method, was applied, and post-tests were processed by the Scheffe method. Results: The average size of each RMS in the Normal, Diastema, and Crowding groups was Normal> Crowding> Diastema. However, the standard deviation was in the order of Crowding> Normal> Diastema. The average value of each data is as follows. Diastema model was the smallest ($5.51{\pm}0.55{\mu}m$), followed by the crowding model ($12.30{\pm}2.50{\mu}m$). The normal model showed the maximum error ($13.23{\pm}1.06{\mu}m$). Conclusion: There was a statistically significant difference in the repeatability of the scanning measurements according to the dentition type. Therefore, you should be more careful when scanning the normal intense or crowded dentition than scanning the interdental lining. However, this error value was within the range of applicable errors for all clinical cases.

4-way Search Window for Improving The Memory Bandwidth of High-performance 2D PE Architecture in H.264 Motion Estimation (H.264 움직임추정에서 고속 2D PE 아키텍처의 메모리대역폭 개선을 위한 4-방향 검색윈도우)

  • Ko, Byung-Soo;Kong, Jin-Hyeung
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.6
    • /
    • pp.6-15
    • /
    • 2009
  • In this paper, a new 4-way search window is designed for the high-performance 2D PE architecture in H.264 Motion Estimation(ME) to improve the memory bandwidth. While existing 2D PE architectures reuse the overlapped data of adjacent search windows scanned in 1 or 3-way, the new window utilizes the overlapped data of adjacent search windows as well as adjacent multiple scanning (window) paths to enhance the reusage of retrieved search window data. In order to scan adjacent windows and multiple paths instead of single raster and zigzag scanning of adjacent windows, bidirectional row and column window scanning results in the 4-way(up. down, left, right) search window. The proposed 4-way search window could improve the reuse of overlapped window data to reduce the redundancy access factor by 3.1, though the 1/3-way search window redundantly requires $7.7{\sim}11$ times of data retrieval. Thus, the new 4-way search window scheme enhances the memory bandwidth by $70{\sim}58%$ compared with 1/3-way search window. The 2D PE architecture in H.264 ME for 4-way search window consists of $16{\times}16$ pe array. computing the absolute difference between current and reference frames, and $5{\times}16$ reusage array, storing the overlapped data of adjacent search windows and multiple scanning paths. The reference data could be loaded upward and downward into the new 2D PE depending on scanning direction, and the reusage array is combined with the pe array rotating left as well as right to utilize the overlapped data of adjacent multiple scan paths. In experiments, the new implementation of 4-way search window on Magnachip 0.18um could deal with the HD($1280{\times}720$) video of 1 reference frame, $48{\times}48$ search area and $16{\times}16$ macroblock by 30fps at 149.25MHz.

A Study on Fractal Analysis and 3D Images of Surface on BST Thin Films. (BST 박막 표면의 프랙탈 분석 및 3D 이미지 특성)

  • Hong, Kyung-Jin;Min, Yong-Ki;Cho, Jae-Cheol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.103-106
    • /
    • 2002
  • The applicability of models based on fractal morphology to characterize $(Ba\;Sr)TiO_{3}$ thin film surfaces was investigated. The fractal morphology of coated barium strontium titan oxide thin film surfaces was described using fractal dimension from scanning electro microscopy image. The $(Ba\;Sr)TiO_{3}$ coating were deposited on silicon wafers using $(Ba\;Sr)TiO_{3}$ solution and spin coater. BST solution was composited by mol ratio, and then spin-coated from 3 times to 5 times coating on $Pt/SiO_{2}/Si$ substrate. Qualitative thin film analysis was performed with scanning electro microscopy (SEM), and surfaces parameters such as average grain diameter, roughness exponent and fractal dimension were determined.

  • PDF