• Title/Summary/Keyword: 3D-Scanning

Search Result 1,479, Processing Time 0.028 seconds

Soft tissue volume changes following gingival grafting for labial gingival recession in the mandibular anterior area: a case report

  • Song, Young Woo;Jung, Ui-Won;Cha, Jae-Kook
    • The Journal of the Korean dental association
    • /
    • v.58 no.1
    • /
    • pp.8-18
    • /
    • 2019
  • This case report presents results for gingival recession coverage following gingival grafting and for gingival biotype enhancements by visualizing soft tissue volume changes using intraoral three-dimensional scanning. A 28 year old female patient with multiple gingival recessions and a 19 year old female patient with a single gingival recession on mandibular anterior area were treated. Root coverage was performed in both cases using autogenous subepithelial connective tissue harvested from palate. Intraoral 3D scan data were obatained presurgery and at 3 months, 1 year, and 2 years postsurgery. The recession areas were recovered successfully by subepithelial connective tissue graft combined with pedicle flap repositioning, and the patients showed neither further recurrence nor post-operative complication. Soft tissue biotype changes were identified by superimposing and analyzing scan data, revealing that gingival biotype was enhanced in both cases. These cases suggest that SCTG could be advantageous in terms of the gingival biotype enhancement, as well as gingival recession coverage, and intraoral 3D scanning might be suitable for assessing post-surgical gingival biotype change.

  • PDF

Development of Indoor Structure Scanner using 2D LIDAR (2D 라이다를 이용한 실내 구조 스캐너 개발)

  • Ki-Jun Kim;Jae-Hyoung Park;Hyun-Min Moon;Ha-Eun Lee;Seung-Dae Lee
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.6
    • /
    • pp.1189-1196
    • /
    • 2023
  • Due to the acceleration of urbanization and advancements in technology, the importance of information related to indoor spaces has been increasing. Various scanning technologies are being developed to enable versatile utilization of the interior of buildings. In this paper, a system is proposed that utilizes 2D LIDAR for scanning, rotating, and moving LIDAR in the vertical direction to obtain a collection of 2D data, which is then aggregated to acquire 3D indoor spatial information. Finally, algorithms, including error correction, are applied to visualize the indoor structure in three dimensions and generate an output.

The Development of a Wrist Brace using 3D Scanner and 3D Printer (3D 스캐너와 3D 프린터를 활용한 손목보호대 개발)

  • Koo, Da Som;Lee, Jeong Ran
    • Fashion & Textile Research Journal
    • /
    • v.19 no.3
    • /
    • pp.312-319
    • /
    • 2017
  • The purpose of this study was to develop a customized wrist brace using 3D scanner and 3D printer. This study included in-depth interviews with people who had wrist pain and ever used wrist braces. The wrist brace has been designed and modeled by the CAD program after 3D scanning the wrist of subjects. Based on the results of the in-depth interviews on wrist brace users and design investigation in the market, a prototype of the wrist brace has been created. The wrist brace does not compress the hand and is easy to put on. In addition, it is adjustable to the wrist of users, allowing them to move his or her wrist without any restrictions. A computer-modeling program produced solid files for the design of the wrist brace after 3D scanning ten subjects' hands. It features a lattice-patterned surface, a velcro adjustment and trimming to smoothen the surface. PLA filaments were used to 3D print the wrist brace. As for the assessment, the wrist brace has been evaluated to be easy to put on and adjust to user's wrist. However, when it comes to appearance and comfortability, it was rated 3.0 or slightly above. This is because 3D printing materials are firm and not flexible compared to other materials such as neoprene or stretchable bands.

Measurement Data Comparison of Fast SAR Measurement System by Probe Arrays with Robot Scanning SAR Measurement System

  • Kim, Jun Hee;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.4
    • /
    • pp.336-341
    • /
    • 2014
  • Dosimetry of radiating electromagnetic wave from mobile devices to human body has been evaluated by measuring Specific Absorption Rate (SAR). Usual SAR measurement system scans the volume by robot arm to evaluate RF power absorption to human body from wireless devices. It is possible to fast estimate the volume SAR by software deleting robot moving time with the 2D surface SAR data acquired by arrayed probes. This paper shows the principle of fast SAR measurement and the measured data comparison between the fast SAR system and the robot scanning system. Data of the fast SAR is well corresponding with data of robot scanning SAR within ${\pm}3$ dB, and its dynamic range covers from 10 mW/kg to 30 W/kg with 4.8 mm probe diameter.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.4
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

3D Modeling Product Design Process Based on Photo Scanning Technology (포토 스캐닝 기술을 기반으로 한 3D 모델링 제품디자인 프로세스에 관한 연구)

  • Lee, Junsang
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.11
    • /
    • pp.1505-1510
    • /
    • 2018
  • Product modeling technology for graphics is rapidly developing. And 3D data application and usability are increasing.modeling of product design is a very important factor in constructing. 3D modeling in product design takes a lot of production time. Recently, the reverse design method is very useful because of application of 3D data and shortening of production time. In this study, first, 3D point cloud and mesh data are generated using photographs based on image data. The second is to modify the design and the third is to make the prototype with the 3D printer. This product design and production process suggests the utilization and possibility of image data, the shortening of 3D modeling production time and efficient processes. Also, the product design process proposes a model of a new product development system to adapt to the production environment.

Flip Chip Bump 3D Inspection Equipment using White Light Interferometer with Large F.O.V. (대시야 백색광 간섭계를 이용한 Flip Chip Bump 3차원 검사 장치)

  • Koo, Young Mo;Lee, Kyu Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.4
    • /
    • pp.286-291
    • /
    • 2013
  • In this paper, in-line type flip chip bump 3D inspection equipment, using white light interferometer with large F.O.V., which is aimed to be used in flip chip bump test process is developed. Results of flip chip bump height measurement in many substrates and repeatability test results for the bumps in fixed location of each substrate are shown. Test results from test bench and those from developed flip chip bump 3D inspection equipment are compared and as a result repeatability is improved by reducing the impact of system vibration. A valuation basis for the testing quality of flip chip bump 3D inspection equipment is proposed.

Measurement of Joint-Orientation and Monitoring of Displacement in Tunnel using 3D Laser Scanning System (3차원 레이저 스캐닝 시스템을 이용한 불연속면의 방향성 측정과 터널 변위 모니터링)

  • Shon, Ho-Woong;Oh, Seok-Hoon;Kim, Young-Kyung
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.1
    • /
    • pp.47-62
    • /
    • 2006
  • More than 70% of Korean Peninsula is consisted of mountains, so that lots of roads, rail-roads and tunnel,which play a pivotal role in the industry activity, are existed along the rock-slope and in the rock-mass. Thus,it is urgent that tegration of management system through the optimum survey and design of rock-slope excavation, proper stabilization method and database of rock-slope. However, conventional methods have shortcoming with the economy of survey time and human resources, and the overcome of difficulties of approach to the in-situ rock-slope. To overcome the limitation of conventional method, this paper proposed the development of remote measurement system using Terrestrial Laser Scanning System. The method using Terrestrial 3D Laser Scanning System, which can get 3D spatial information on the rock-slope and2)Dept. Geosystem Engineering, Kangwon National University, Korea tunnel, has an advantage of reduction of measurement time and the overcome of difficulties of approach to the in-situ rock-slope/dam/tunnel. In the case of rock-slope, through the analysis of 3D modeling of point-cloud by Terrestrial Laser Scanning System, orientation of discontinuity, roughness of joint surface, failure shape and volume were successively achieved. in the case of tunnel face, through reverse-engineering, monitoring of displacement was possible.

  • PDF

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

  • Rhee, Ye-Kyu;Huh, Yoon-Hyuk;Cho, Lee-Ra;Park, Chan-Jin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.6
    • /
    • pp.460-467
    • /
    • 2015
  • PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The three-dimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For two-dimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

Reconstruction of Optical Scanning Holography with Segmentation

  • Im, Dong Hwan;Kim, Taegeun;Kim, Kyung Beom;Lee, Eung Joon;Lim, Seung Ram
    • Current Optics and Photonics
    • /
    • v.5 no.6
    • /
    • pp.680-685
    • /
    • 2021
  • We propose a technique that reconstructs a hologram whose pixel number is greater than the pixel numbers of a conventional image sensor. The pixel numbers of the hologram recorded by optical scanning holography (OSH) increases as the scan area becomes larger. The reconstruction time also increases drastically as the size of the hologram increases. The holographic information of a three-dimensional (3D) scene is distributed throughout the recorded hologram; this makes the simple divide-and-stitch approach fail. We propose a technique that reconstructs the hologram without loss of holographic information. First, we record the hologram of a 3D scene using OSH. Second, we segment the hologram into sub-holograms that contain complete holographic information. Third, we reconstruct the sub-holograms simultaneously. Finally, we rearrange the reconstructions of the sub-holograms.