• Title/Summary/Keyword: 3D-LCD

Search Result 233, Processing Time 0.032 seconds

NUMERICAL ANALYSIS FOR CONDUCTION HEAT TRANSFER AND APPRAISAL OF PERFORMANCE INDICES IN LED MONITOR FOR LAPTOP COMPUTER (노트북 LED 영상장치 내부의 전도열전달 해석과 성능 지수 평가)

  • Park, I.S.;Sohn, C.H.;Son, D.H.;Baik, S.M.;Park, C.
    • Journal of computational fluids engineering
    • /
    • v.16 no.3
    • /
    • pp.47-51
    • /
    • 2011
  • Dark Mura phenomena which can happen at the region with high temperature gradient in a Notebook LCD Monitor using LED light source has numerically been studied. The calculation was conducted under the nearly realistic conditions by considering the anisotropic thermal properties of materials and the real dimensions of each component. The two performance indices of LED monitor, i.e., the maximum temperature and the spacial gradient of temperature were examined for the various shapes, lengths and thickness of heat sink plate. Calculated results give more reasonable temperature distribution comparing with experimental results.

Enhanced Light Outcoupling on Photo-luminescent Devices with Microcavity (Microcavity 적용 광자 발광 소자의 광 추출 향상 연구)

  • Lee, Han Byul;Lee, Eun Hye;Sung, Min Ho;Ryu, Si Hong;Lee, Seong Eui
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.26 no.5
    • /
    • pp.391-396
    • /
    • 2013
  • Recently, microcavity is studied to reduce the optical loss of BLU and OLED. In this paper, we suggest applying microcavity to photo-luminescent lamp with plasma discharge technology to meet the display applications for a BLU for LCD. The structure of photo-luminescent lamp consists of SUS foil and ITO glass with microcavity. The opto-electric characteristics of photo-luminescent lamp with microcavity was evaluated. The brightness of photo-luminescent device was increased over $111cd/m^2$ with the adaptation of patterned microcavity at $30{\mu}m$. The 3D optical simulation verified the enhanced light outcoupling when microcavity applied to the device.

Synthesis and Anaiysis of Photohnninescence Properties of $^5D_1$$^7F_1$ Transition in $LaGaO_3$:$Eu^{3+}$ Red Phosphor ($LaGaO_3$:$Eu^{3+}$형광체의 합성 및 발광 특성)

  • Kim, Kyoung Hwa;Choi, Yoon Young;Sohn, Kee Sun;Kim, Chang Hae;Park, Hee Dong;Choe, Se Young
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.5
    • /
    • pp.453-459
    • /
    • 2000
  • FED has deserved an intensive attentioD as a new flat panel display. The present investigationaims at undemtanding the photoluminescence and cathodoluminescent properties of hGaO$_3$: $Eu^{3+}$ phosphor bytaking into account the possibility that this phosphor could be applied for FED. In onler to investigate on.sucha detailed behavior; 8everM experimental skil18 Je conducted to the LaGaO$_3$:$Eu^{3+}$ phosphoL The excimtion srectrum artd emission spectmn were rnezsured in the UV range and then decay curve of $^5D_0$+$^7F_j$transitions\vas examined. The decay behavior of $^5D_0$ emission was anMyzed by a newly Iuoposed cross-relaxation mech-ani8In in asswiation with inteFwnter di1ffision (or migration). The cross-mlaxation from $^5D_0$ to CTB (Cha'geTransfer Band) wuld be a quite retsonable by considering the excitation spectrum. It could be also found thatthe quenching type was changed from ditfrsion controlled process to the direct quenching process -s inJeasing $Eu^{3+}$ oncntration.

  • PDF

Application of 3-D Scanner to Analysis of Functional Instability of the Ankle

  • Han, Cheng-Chun;Kubo, Masakazu;Matsusaka, Nobuou;Ishimatsu, Takakazu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1971-1975
    • /
    • 2003
  • This paper describes a technique, which analyzes the functional instability of the ankle using three-dimensional scanner. The technique is based on the structured light pattern projection method, which is performed by using one digital still camera and one LCD projector. This system can be easily realized with the low cost. The measuring result has high accuracy. The measuring error is about 0.2 mm or less. Using this technique the three-dimensional posture of the leg and foot of the target person are measured and analyzed.

  • PDF

Characterization of ZnO:Al(AZO) Transparent Conduction Film produced by DC Magnetron Sputtering Method

  • Koo, Hong-Mo;Kim, Se-Hyun;Moon, Yeon-Keon;Park, Jong-Wang;Jeong, Chang-Ho
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1546-1549
    • /
    • 2005
  • Al-doped ZnO (ZnO:Al) thin films were grown on corning 1737 glass substrates by dc magnetron sputtering. The structural, electrical and optical properties of the films were investigated as a function of various discharge power. The obtained films were polycrystalline with a hexagonal wurtzite structure and preferentially oriented in the (002) crystallographic direction. The lowest resistivity is $6.0{\times}10^{-4}$ Ocm with the carrier concentration of $2.694{\times}10^{20}$ $cm^{-3}$ and Hall mobility of $20.426cm^2/Vs$. The average transmittance in the visible range was above 90%.

  • PDF

Simulation for Electro-Optic Characteristics of the Fringe-Field Driven Reflective Hybrid Aligned Nematic Liquid Crystal Display with One Polarizer (1매의 편광판으로 구성된 Fringe-Field 구동형 반사형 Hybrid Aligned Nematic 액정디스플레이의 전기-광학 특성에 관한 시뮬레이션)

  • 박지혁;정태봉;이종문;김용배;이승희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.10
    • /
    • pp.908-913
    • /
    • 2003
  • We have performed computer simulation to obtain electro-optic characteristics of reflective hybrid aligned nematic liquid crystal displays (LCDs) driven by fringe field. The results show that the optimal retardation value (dΔn) of the cell is 0.289 ${\mu}$m, which allows for the cell to have a practical cell gap of larger than 3 ${\mu}$m when manufacturing. A reflectance of the dark state is only 0.114 % for an incident light 550 nm. At this condition, the light efficiency of white state reaches 92.7 %. The display with optimized cell parameters shows that the contrast ratio greater than 5 exists over 600 of polar angle in all directions and lower driving voltage than that of fringe-field driven homogeneously aligned reflective LCD.

IoT-based Smart Pillbox for Efficient Medication Management (효율적인 복약 관리를 위한 IoT 기반 스마트 약상자)

  • Park, Jae Hwan;Lee, Hyeon Jeong;Kwon, Nam Kyu
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2021.01a
    • /
    • pp.309-312
    • /
    • 2021
  • 본 연구에서는 약 관리를 효율적으로 할 수 있는 IoT 기반의 스마트 약상자를 개발하였다. 약을 정기적으로 먹어야 하는 사용자에 대해 약 복용 현황 및 남아 있는 약의 상황 등을 모니터링 하여 효과적으로 관리할 수 있다. 이를 위해 약을 보관할 수 있는 상자를 3D 프린터를 이용하여 제작하였으며, 사용자의 복약 현황을 나타내주는 LCD를 전면에 배치했다. 또한, 약상자 내부에 있는 서보모터를 활용하여 정해진 복용 시간에 정해진 양만큼의 약을 제공할 수 있도록 하였다. 제안하는 스마트 약상자를 이용하여 사용자의 복약을 효율적으로 관리할 수 있으며 복약 순응도를 높이고 약물의 오남용을 막는데 도움을 줄 수 있다.

  • PDF

Synthesis and Properties of New Phthaloperinone Dyes containing Anthraquinone Moiety (Anthraquinone을 포함하는 신규 Phthaloperinone 색소의 합성과 특성에 대한 연구)

  • Jun, Kun;Gwon, Seon Yeong;Kim, Yu Jin;Kim, Sung Hoon
    • Textile Coloration and Finishing
    • /
    • v.28 no.2
    • /
    • pp.57-62
    • /
    • 2016
  • We have synthesized five novel phthaloperinone dyes via a condensation reaction to be applied as yellow colorants for liquid crystal display(LCD) color filters. The reaction between 1,8-naphthalic anhydride(1a), 4-chloro-1,8-naphthalic anhydride(1b), 4-bromo-1,8-naphthalic anhydride(1c), 3-nitro-1,8-naphthalic anhydride(1d), 4-nitro-1,8-naphthalic anhydride(1e) and 1,2-diaminoanthraquinone(2) proceeded readily giving a product in 72-88% yields. The synthesized dyes were characterized by UV-Vis, mass spectrometry and elemental analysis. The spectral properties and thermal stability of the dyes were examined. The dyes absorb at around 400-450nm. All five dyes showed satisfactory thermal stability: the dyes retain 99-100% of its original weight at $300^{\circ}C$, 98-100% at $350^{\circ}C$, 92-98% at $400^{\circ}C$, and 84-92% at $450^{\circ}C$. We have quantitatively evaluated the reaction mechanism and reactivity of dye molecules by means of Pariser-Parr-Pople Molecular Orbital Method(PPP-MO).

Output Characteristics of a LGP for TFT-LCD with Pyramid Shaped Pattern (피라미드 패턴으로 제작된 TFT-LCD용 도광판의 출력 특성)

  • Kim, Young-Chul;Ahn, Seong-Joon;Ahn, Seung-Joon;Oh, Tae-Sik;Kim, Ho-Seob;Kim, Dae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.11
    • /
    • pp.3080-3086
    • /
    • 2009
  • We have analyzed the output characteristics of a LGP with pyramid shaped pattern by using a 3-D simulation tool. The influences on the LGP output of various parameters such as the pattern shape, pattern occupation ratio, pattern size, and etching angle were investigated. Comparing the pyramid shaped pattern with hemispherical patterns, little difference was observed. And, it was proved that the pattern occupation ratio and etching angle have relatively large effects on LGP output characteristics, while the pattern size has no effect. Therefore, we can improve the LGP characteristics by optimizing pattern structure and distribution.

A FSK Radio-telemetry System for Monitoring Vital Signs in UHF Band (UHF 대역 FSK에 의한 생체신호 무선 전송장치의 개발)

  • Park D.C.;Lee H.K.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.255-260
    • /
    • 2000
  • This paper presents a radio-telemetry patient monitor. which is used for intensive cal?e units. emergency and surgical operation rooms to monitor continuously patients' vital signs. The radio-telemetry patient monitor consists of a vital sign acquisition unit. wireless data transmission units and a vital sign-monitoring unit. The vital sign acquisition unit amplifies biological signals, performs analog signal to serial digital data conversion using the one chip micro-controller. The converted digital data is modulated FSK in UHF band using low output power and transmitted to a remote site in door. In comparison with analog modulation. FSK has major advantages to improve performance with respect to noise resistance with fower error and the potential ability to process and Improve quality of the received data. The vital sign-monitoring unit consists of the receiver to demodulate the modulated digital data, the LCD monitor to display vital signs continuously and the thermal head printer to record a signal.

  • PDF