• 제목/요약/키워드: 3D-CT

검색결과 1,110건 처리시간 0.025초

치골 부위의 CT 적층 영상을 활용한 3D 기하학적 곡면 모델로의 가공 (Construction of 3D Geometric Surface Model from Laminated CT Images for the Pubis)

  • 황호진;문두환;황진상
    • 한국CDE학회논문집
    • /
    • 제15권3호
    • /
    • pp.234-242
    • /
    • 2010
  • 3D CAD technology has been extended to a medical area including dental clinic beyond industrial design. The 2D images obtained by CT(Computerized Tomography) and MRI(Magnetic Resonance Imaging) are not intuitive, and thus the volume rendering technique, which transforms 2D data into 3D anatomic information, has been in practical use. This paper has focused on a method and its implementation for forming 3D geometric surface model from laminated CT images of the pubis. The implemented system could support a dental clinic to observe and examine the status of a patient's pubis before implant surgery. The supplement of 3D implant model would help dental surgeons settle operation plans more safely and confidently. It also would be utilized with teaching materials for a practice and training.

미세수술을 이용한 하지의 재건시 삼차원 컴퓨터 혈관조영술의 유용성 (Usefullness with 3D CT Angiography in Microsurgical Reconstruction)

  • 성용덕;김효헌
    • Archives of Plastic Surgery
    • /
    • 제33권2호
    • /
    • pp.175-180
    • /
    • 2006
  • Preoperative angiography is frequently used in the planning of microsurgical reconstruction for identification of vascular abnormality that influence the planning of operation. But, recently 3D CT angiography is considered as new technique that can provide detailed information about vascular anatomy as well as soft and bony tissue without the risks of invasive angiography. 3D CT angiograms were performed in 19 patients before microsurgical reconstruction for the lower extremity and hand between May of 2003 and Oct of 2004. Sixteen of the studies were of the donor site and all of 19 studies were of the recipient site. No complications were found from the 3D CT angiograms. In one case of the bone exposed open wound, the injury of anterior tibial artery was identified and the zone of injury was adequately demonstrated. With the improvement in quality of CT imaging, 3D CT angiograms may provide a favorable alternative to invasive angiography. It is capable of providing high-resolution, three dimensional vascular imaging without the need for arterial puncture and prolonged post-procedure observation. The relation among blood vessels, bones, and soft tissue is well demonstrated in 3D CT angiogram. Also The acquisition time and examination cost were considerably lower in comparison with invasive angiography. In conclusion, this study demonstrates that 3D CT angiography may provide accurate, safe, and cost-effective preoperative imaging. The 3D CT angiography with relatively low morbidity, low cost, ease of image acquisition can have an broader role in microsurgical reconstructive surgery.

PET/CT 팬텀의 3D 프린팅 소재 적용 가능성 평가 (Evaluation of the Applicability of PET/CT Phantom as a 3D Printing Material)

  • 이주영;김지현;박훈희
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권5호
    • /
    • pp.423-431
    • /
    • 2022
  • The purpose of this study is to present objective information in applying 3D printing technology for PET/CT (Positron Emission Tomography/Computed Tomography) performance evaluation and use it as a basic research that can be applied to various purposes in the future. Phantoms were manufactured with step wedge of ABS(Acrylonitrile Butadiene Styrene) and ACR(Acrylic acid) material. The counts for each ROI(Region of Interest) were analyzed through image acquisition in PET/CT. And the variation rate of counts and CNR(Contrast Noise Ratio) was evaluated. In the counts analysis, the effect of thickness occurred. In addition, in the variation rate analysis, the thickness setting of steps wedge 4 to 5 levels should be considered first. These results minimize quantitative and qualitative changes in the phantom manufactured based on 3D printing, and enable more stable PET/CT performance evaluation. Based on 3D printing in PET/CT, various phantoms are expected to be produced in the future. If the characteristics of each material are considered and applied through the basic research such as this research, the result of the phantom manufactured through 3D printing can be more meaningful and will be used in a wide range.

A comparative study between data obtained from conventional lateral cephalometry and reconstructed three-dimensional computed tomography images

  • Oh, Suseok;Kim, Ci-Young;Hong, Jongrak
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제40권3호
    • /
    • pp.123-129
    • /
    • 2014
  • Objectives: The aim of this study was to verify the concordance of the measurement values when the same cephalometric analysis method was used for two-dimensional (2D) cephalometric radiography and three-dimensional computed tomography (3D CT), and to identify which 3D Frankfort horizontal (FH) plane was the most concordant with FH plane used for cephalometric radiography. Materials and Methods: Reference horizontal plane was FH plane. Palatal angle and occlusal plane angle was evaluated with FH plane. Gonial angle (GA), palatal angle, upper occlusal plane angle (UOPA), mandibular plane angle (MPA), U1 to occlusal plane angle, U1 to FH plane angle, SNA and SNB were obtained on 2D cephalmetries and reconstructed 3D CT. The values measured eight angles in 2D lateral cephalometry and reconstructed 3D CT were evaluated by intraclass correlation coefficiency (ICC). It also was evaluated to identify 3D FH plane with high degree of concordance to 2D one by studying which one in four FH planes shows the highest degree of concordance with 2D FH plane. Results: ICCs of MPA (0.752), UOPA (0.745), SNA (0.798) and SNB (0.869) were high. On the other hand, ICCs of gonial angle (0.583), palatal angle (0.287), U1 to occlusal plane (0.404), U1 to FH plane (0.617) were low respectively. Additionally GA and MPA acquired from 2D were bigger than those on 3D in all 20 patients included in this study. Concordance between one UOPA from 2D and four UOPAs from 3D CT were evaluated by ICC values. Results showed no significant difference among four FH planes defined on 3D CT. Conclusion: FH plane that can be set on 3D CT does not have difference in concordance from FH plane on lateral cephalometry. However, it is desirable to define FH plane on 3D CT with two orbitales and one porion considering the reproduction of orbitale itself.

경부 종물 환자의 이해도 개선을 위한 3차원 재건 영상의 활용 (3D Reconstructed Image of Neck Mass to Improve Patient's Understanding)

  • 유영삼
    • 대한두경부종양학회지
    • /
    • 제26권2호
    • /
    • pp.193-197
    • /
    • 2010
  • Objectives : Patients with neck tumor and their family need every information about the disease. Especially, the size and location are confusing with verbal information. With the aid of CT, the problem had some answer, but it needs some medical education. We would like to know the usefullness of 3D reconstructed images in patient education about the disease. Material and Methods : Neck CT data were collected from 10 patients with various neck tumors and converted to 3D reconstructed images. Understanding of the patients about the size and location of tumors were rated from questionaires using axial CT images and 3D images. Results : Understanding score about 3D images were greater than that of CT images(p<0.006). Conclusion : 3D reconstructed images of CT could give the patients more real visual information about the disease.

3D 프린팅을 사용한 Infill 조절에 따른 Elbow 팬텀 제작 및 유용성 평가에 관한 연구 (A Study on Elbow Phantom Production and Usability Evaluation by Adjusting Infill Density using 3D Printing)

  • 김명인;지승호;위현섭;이대원;장희민;윤명성;한동균
    • 한국방사선학회논문지
    • /
    • 제17권6호
    • /
    • pp.929-937
    • /
    • 2023
  • 3D 프린터를 이용하여 제작되는 인체 등가 팬텀은 기존의 인체 팬텀에 비해 저렴하고 단시간에 제작이 가능하다. 다만, 3D 프린터 출력 설정 변수 중 하나인 내부채움(Infill Density)을 100 % 미만으로 하여 제작되는 팬텀이 다수이다. 따라서 본 연구는 3D 프린터를 이용하여 제작된 다섯 개의 Infill 비율을 달리한 Bone 팬텀의 CT number를 실제 인체 Bone의 CT number와 비교하였다. 또한, Infill 100 %의 팔굽 관절 팬텀을 제작하여 컴퓨터 단층촬영(CT)에서 각 조직 별 CT number 비교를 통해 Infill을 100 %로 설정하여 제작된 팬텀에 대한 유용성을 평가하였다. 그 결과 Infill 100 %로 출력한 Bone 팬텀이 실제 인체 Bone의 CT number 값과 가장 통계적으로 유의한 차이를 보이지 않았고, Infill 100 %로 제작된 팔굽 관절 팬텀 역시 각 조직의 CT number는 실제 인체 팔굽 관절의 각 조직의 CT number 값과 통계적으로 유의한 차이를 보이지 않았다.

두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정 (Effective Dose Determination From CT Head & Neck Region)

  • 윤재혁;이광원;조영기;최지원;이준일
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권2호
    • /
    • pp.105-116
    • /
    • 2011
  • 두경부(Head & Neck) CT(Computed Tomography)검사에서 환자가 받는 피폭선량 측정을 위하여 인체등가물질로 만든 Rando phantom과 유리선량계를 이용하여 두경부 검사에 따른 환자의 흡수선량의 변화를 실험을 통하여 연구하였다. 인체두부모형을 안와신경(optic nerve), 교뇌(pons), 소뇌(cerebellum), 갑상선(thyroid)으로 나누어, 두경부(Head & Neck) 부위의 검사를 단독검사(Brain, 3D Facial, Temporal, Brain Angiography, 3D Cervical Spine)와 복합검사(Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spin+Angiography)로 구분하여 유효선량의 변화를 실험한 후 결과를 측정하였다. 단순 Brain검사와 Brain Angio검사에는 optic nerve에 유효 선량이 높게 분석되었으며, 또한 Temporal검사에는 Pons에, 3D facial 검사와 3D Cervical Spin검사에는 thyroid의 유효선량 값이 높게 나타났다. 복합적으로 이루어는 검사 중 두경부의 Brain+Brain Angio의 검사는 cerebellum의 부위, Brain+3D facial 검사와 Brain+3D Cervical Spin의 복합검사는 thyroid의 부위, Brain+Temporal의 검사에는 pon's 부위 유효 선량 값이 높게 나타났다. Brain +3D facial +Temporal의 복합검사와 Brain+3D Cervical Spin+Angio의 복합검사는 thyroid의 부위에 유효 선량 값이 높게 분석 되었다. 본 연구 결과 Brain+3D Cervical Spin+Brain Angio 복합검사인 경우의 유효 선량은 2.51858 mSv로 일반인의 연간 유효선량한도 1 mSv의 피폭을 초과하는 결과가 나왔다. 또한, Brain 단순 검사 시 optic nerve는 0.31312 mSv의 유효선량으로 향후 방사선학 검사가 이루어질 경우, 두경부의 일반인의 연간 유효선량을 훨씬 초과할 것이라 사료된다. 따라서 진료의 필요성에 의해서 시행되는 CT검사일지라도 질환 병변의 특성에 맞게 CT촬영조건 변화를 주면서 환자의 피폭선량을 최소한으로 할 수 있는 다양한 검사방법의 연구가 필요하다고 사료된다.

마이크로 CT 이미지를 활용한 3D 프린팅 콘크리트의 공극 분포에 따른 인장파괴의 거동 예측 (Prediction of Mechanical Response of 3D Printed Concrete according to Pore Distribution using Micro CT Images)

  • 유찬호;김지수
    • 대한토목학회논문집
    • /
    • 제44권2호
    • /
    • pp.141-147
    • /
    • 2024
  • 본 연구에서는 마이크로 CT 이미지를 활용하여 3D 프린팅 콘크리트의 공극분포 특성에 따른 인장파괴 강도를 확인하였다. 3D 프린팅 기법으로 출력된 콘크리트 구조물은 일반적인 시편과는 다르게 적층방향 및 필라멘트 접촉면의 존재에 따라 공극의 방향성을 갖는다. 이에 따라 3D 프린팅 콘크리트 시편의 공극분포를 확률론적 방법으로 분석하고, 유한요소기법을 통해 방향별 인장강도를 분석하였다. 3D 프린팅된 시편 내부의 공극이 방향성을 갖는 것을 확인하였고, 출력에 의한 미세구조 특성-강도의 영향성을 평가하였다. 본 연구는 마이크로 CT 이미지 기반의 공극 분포 특성을 분석하고 시뮬레이션을 활용한 기계적 물성 평가를 수행하여 보다 향상된 성능의 적층 구조물 설계 및 재료 개발에 활용하고자 한다.

요추의 2차원 CT 영상을 이용한 3차원 형상모델링의 자동화 연구 (A Study on Automated 3-D Reconstruction Based on 2-D CT Image of Lumber Spine)

  • 김성민;김성재;서성영;탁계례
    • 대한의용생체공학회:의공학회지
    • /
    • 제20권5호
    • /
    • pp.581-586
    • /
    • 1999
  • 척추의 생체역학적 해석을 위한 유한요소기법을 이용한 컴퓨터 시뮬레이션은 척추의 손상에 대한 발생원인과 기전을 이해하고 치료의 효과를 예측하는 유용한 수단으로 기대되고 있다. 본 논문에서는 요추의 2차원 CT 영상을 이용하여 유한요소해석을 위한 척추의 3차원 모델링에 소비되는 많은 시간을 줄일 수 있도록 3차원 형상모델을 CT 형상 데이터와 형상변수를 이용, 각각 구현하는 과정을 자동화하여 이를 비교하였다.

  • PDF

3차원 전산화 단층촬영의 Nasion, Sella, Basion으로 구성된 정중 시상 평면과 정면 두부방사선 규격사진의 정중 시상 평면 비교 (Comparison of midsagittal reference plane in PA cephalogram and 3D CT)

  • 조진형;문지연
    • 대한치과교정학회지
    • /
    • 제40권1호
    • /
    • pp.6-15
    • /
    • 2010
  • 안면 비대칭의 평가에 있어 과거 정면 두부방사선 규격사진을 이용하던 것과는 다르게 현재는 점차 3D CT를 이용하여 평가하는 것으로 변하고 있다. 본 연구는 3D CT와의 비교를 이용하여 정면 두부방사선 규격사진 분석에서 쉽게 접근할 수 있는 시상 기준 평면을 찾고자 하였다. 임상적으로 안모 비대칭이 발견되지 않은 성인 환자들을 대상으로 3D CT와 정면 두부방사선 규격사진을 촬영하였고, 정면 두부방사선 규격사진 분석에서 이용되어 왔던 5가지 정중 시상 기준 평면을 선택하여 계측을 실시한 뒤 이 값을 3D CT의 Nasion (Na), Sella (S), Basion (Ba)으로 구성된 정중 시상 평면에 대한 계측값과 비교하였다. 그 결과 좌우측 latero-orbitale의 수직이등분선을 정중 시상 기준 평면으로 이용한 정면 두부방사선 규격사진 계측값이 3D CT의 Na, S, Ba으로 구성된 정중 시상 평면을 이용한 계측값과 가장 차이가 작았고 상관관계가 높은 것으로 나타났다. 안면 비대칭 평가 시 좌우측 latero-orbitale의 수직이등분선이 정면 두부방사선 규격사진 분석에서 도움이 되는 정중 시상 기준 평면으로 이용될 수 있을 것이다.