• Title/Summary/Keyword: 3D video

Search Result 1,155, Processing Time 0.034 seconds

The Kinematical Analysis of female 500m Sprint Start in 2005 World Short Track speed Skating Championship (2005 세계 쇼트트랙 스피드 여자 500m 스피드 스케이팅 출발구간에 대한 운동학적 분석)

  • Lee, Chong-Hoon;Back, Jin-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.169-179
    • /
    • 2005
  • In the 500m short track speed skating, the matter of who reaches the first corner first can important factor since each competitor races with all speed from the start to the first line. A filed study was attempted to kinematical estimation six female foreign skaters, who participated in the 500m female final round competition, and two Korea skates during the World Short track Skating Championship. The three dimensional motion analysis with DLT method was executed using four video cameras for analyzing the actual competition situation. In point of analyzing the actual competition situation, it is expected that skaters and coaches the effective informations, and the following conclusions are drawn; The elapsed time by phase in start motion of the foreign skaters appeared shorter those of Korea skaters, so the start training of Korea skaters should be strengthed. Also the displacement of C.G in the foreign skaters appeared shorter displacement than those of Korea skaters. Especially in the starting position, the foreign skaters are superior to Korea skaters in displacement of first(left) and next following stroke(right). The velocity of C.G and maximum velocity of skate blade of foreign skaters art faster than those of Korea skaters. And the foreign skaters show the superior early velocity change. Both of leaning body angle, and left and knee angle of the foreign skaters lead to positive point of having the propulsive force in the early starting position. Observing in the most prominent feature of foreign and Korea skaters in start phase, foreign skaters skate quickly the third stroke. These features of Korea skaters would appear disadvantage of location selection in entering the coner course.

Developed sound reaction based and top-down floating hologram device (사운드 반응 기반 상향식, 하향식 플로팅 홀로그램 디바이스 개발)

  • Park, Jang-won;Ha, Jong-soo;Hwang, Sang-hyeon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.97-100
    • /
    • 2018
  • The floating holograms currently being commercialized are one-way floating holograms. One-way floating holograms are used for performances and exhibitions, and the implementation method is to reflect the image contents into the reflecting glass at $45^{\circ}$ through a single presentation medium. This creates as inefficient a space as the remaining space of reflective glass tilted at $45^{\circ}$, and even more inefficient space if the video content is presented larger. Therefore, the installation space of a one-way floating hologram is restricted. This paper aims to improve users' satisfaction by developing an upper and lower floating hologram with efficient installation of a one-way floating hologram that is currently commercialized, integrating sound output systems and producing new types of speaker products.

  • PDF

DEVELOPMENT OF THE 5GHZ CONTINUUM RECEIVER SYSTEM (5GHZ대 연속 전파 수신 시스템의 개발)

  • Byeon, Do-Yeong;Choi, Han-Gyu;Lee, Jeong-Won;Gu, Bon-Cheol
    • Publications of The Korean Astronomical Society
    • /
    • v.11 no.1
    • /
    • pp.109-123
    • /
    • 1996
  • We have developed a 5GHz continuum receiver system. The receiver is a direct type receiver. In order to reduce the noise due to the fluctuation of the gain in the amplifiers, the system employs the Dicke switching method. We made the 5GHz low-noise amplifier and the bandpass filter. The low-noise amplifier gives ${\sim}35dB$ gain and has ${\sim}210K$ noise temperature. The bandpass filter has a passband between 4.3 and 5.4GHz. We also made switch driver, video amplifiers, phase detector, and integrator. Using a 1.8 meter offset parabolic antenna, we measured the efficiency of the system. Since the antenna does not have a driver to track objects, observations were performed with the antenna fixed. The measured noise temperature of the system is ${\sim}650K$. From the observation of the blank sky, noise level was measured. It was found that the systematic noise(${\sim}0.5K$: peak to peak value) is much larger than the thermal noise. The systematic noise is possibly related to the stability of the DC power supplied to the receiver system. Besides the noise of the system, it was found that the airplanes are the very serious noise sources. We measured the radio flux of the Sun using the developed system. The observed radio flux of the Sun is ${\sim}10^6Jy$, which is close to the known value of the quiet Sun. The test observation of the Sun shows that the angular beam size of the antenna is ${\sim}2.2^{\circ}$.

  • PDF

Experiences in Patient Safety Education of Patient Safety Officer Using Focus Group Interview (포커스 그룹 인터뷰를 이용한 환자안전전담자의 환자 및 보호자 대상 환자 안전 교육 경험 분석)

  • Kim, Yoon-Sook;Kim, Moon-Sook;Hwang, Jee-In;Kim, Hye-Ran;Kim, Hyun-Ah;Kim, Hyuo-Sun;Chun, Ja-Hae;Kwak, Mi-Jeong
    • Quality Improvement in Health Care
    • /
    • v.25 no.2
    • /
    • pp.2-15
    • /
    • 2019
  • Purpose: The purpose of this study is to provide basic data for the development of the most appropriate and effective educational materials for patients and their caregivers through the educational experiences of patient safety officer. Methods: This study is a qualitative analysis that involves using the focus group interview to understand the patient safety education experience of the patient safety officer. Results: The patient safety education experience of the patient safety officer is divided into four topics: (1) patient safety education content (2) patient safety education method (3) patient safety education status (4) activation and improvement of patient safety education. Additionally, the study incorporated twelve subtopics: (a) falls (b) speak up (c) patient safety campaign (d) patient safety rounding and a one on one training (e) education through medical staff (f) education using broadcast, video, post, among others (g) a lot of education in patient (h) patients not interested in patient safety education (i) patient safety education is less effective (j) human and medical expenses support (k) provision of standardized educational materials (l) patient safety culture for patient participation. Conclusions: This study indicate that education for patients and the caregivers should be inclusive and protective of stakeholders from the risks involved in patient safety events. The experience of patient safety officer is necessary for patient safety education for both patients and the caregivers since it is the source of basic data for the future development of patient safety education.

Technological trend of VR/AR maintenance training and API Implementation Example based on Unity Engine (VR/AR 정비교육의 기술동향과 유니티 엔진기반의 API 구현사례)

  • Lee, Jee Sung;Kim, Byung Min;Choi, Kyu Hwa;Nam, Tae Hyun;Lim, Chang Joo
    • Journal of the Korean Society for Computer Game
    • /
    • v.31 no.4
    • /
    • pp.111-119
    • /
    • 2018
  • National agencies and corporations are making a lot of efforts to educate mechanics from high school to university and enterprise training center to train as skilled mechanic. but the theoretical training using textbooks and the training using equipment not used in the field did not provide proper maintenance training. And education using special equipment or assuming dangerous situation was very dangerous, so we were carrying out education with video or photo. In recent, there have been a number of cases in which effective training simulations have been researched and developed in order to experience situations and solve problems safely through simulation from simple maintenance to special maintenance by combining VR and AR. This paper describes the comparative study of the existing APIs such as Danuri VR, DisTi Engine and Remote AR for general purpose AR/VR contents. We also proposed a AR/VR API based on Unity 3D Engine for AR/VR maintenance contents. The API can be used for maintenance contents developers efficiently.

Utilization of Supplemental Regional Anesthesia in Lobectomy for Lung Cancer in the United States: A Retrospective Study

  • Alwatari, Yahya;Vudatha, Vignesh;Scheese, Daniel;Rustom, Salem;Ayalew, Dawit;Sevdalis, Athanasios E.;Julliard, Walker;Shah, Rachit D.
    • Journal of Chest Surgery
    • /
    • v.55 no.3
    • /
    • pp.225-232
    • /
    • 2022
  • Background: Pulmonary lobectomy is the standard of care for the treatment of early-stage non-small cell lung cancer. This study investigated the rate of utilization of supplemental anesthesia in patients undergoing video-assisted thoracoscopic surgery (VATS) or open lobectomy using a national database and assessed the effect of regional block (RB) on postoperative outcomes. Methods: Patients who underwent lobectomy for lung cancer between 2014-2019 were identified in the American College of Surgeons National Surgical Quality Improvement Program. The patients' primary mode of anesthesia and supplemental anesthesia were recorded. Preoperative characteristics and postoperative outcomes were compared between 2 surgical groups: those who underwent general anesthesia (GA) alone versus GA with RB. Multivariable regression analyses were performed on the outcomes of interest. Results: In total, 13,578 patients met the study criteria, with 87% undergoing GA and the remaining 13% receiving GA and RB. The use of neuraxial anesthesia decreased over the years, while RB use increased up to 20% in 2019. Age, body mass index, and preoperative comorbidities were comparable between groups. Patients who underwent VATS were more likely to receive RB than those who underwent thoracotomy. RB was most often utilized by thoracic surgeons. An adjusted analysis showed that RB use was associated with shorter hospital stays and a reduced likelihood of prolonged length of stay, but a higher rate of surgical site infections (SSIs). Conclusion: In a large surgical database, there was underutilization of supplemental anesthesia in patients undergoing lobectomy for lung cancer. RB utilization was associated with a shorter length of hospital stay and an increase in SSI incidence.

An experimental study on triaxial failure mechanical behavior of jointed specimens with different JRC

  • Tian, Wen-Ling;Yang, Sheng-Qi;Dong, Jin-Peng;Cheng, Jian-Long;Lu, Jia-wei
    • Geomechanics and Engineering
    • /
    • v.28 no.2
    • /
    • pp.181-195
    • /
    • 2022
  • Roughness and joint inclination angle are the important factors that affect the strength and deformation characteristics of jointed rock mass. In this paper, 3D printer has been employed to make molds firstly, and casting the jointed specimens with different joint roughness coefficient (JRC), and different joint inclination angle (α). Conventional triaxial compression tests were carried out on the jointed specimens, and the influence of JRC on the strength and deformation parameters was analyzed. At the same time, acoustic emission (AE) testing system has been adopted to reveal the AE characteristic of the jointed specimens in the process of triaxial compression. Finally, the morphological of the joint surface was observed by digital three-dimensional video microscopy system, and the relationship between the peak strength and JRC under different confining pressures has been discussed. The results indicate that the existence of joint results in a significant reduction in the strength of the joint specimen, JRC also has great influence on the morphology, quantity and spatial distribution characteristics of cracks. With the increase of JRC, the triaxial compressive strength increase, and the specimen will change from brittle failure to ductile failure.

Implementation of AESA Radar Integration Analysis System by using Heterogeneous Media

  • Min-Jung Kang
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.3
    • /
    • pp.117-125
    • /
    • 2024
  • In this paper, implement and propose an Active Electronically Scanned Array (AESA) radar integration analysis system which specialized for radar development by using heterogeneous media. Most analysis systems are used to analyze and improve the cause of defects, so they help the test easier. However, previous log analysis systems that operate only based on text are not intuitive and difficult to find the information user want at once if there is a lot of log information. so when an equipment defect occurs, there are limitations in analyzing the cause of defect. Therefore, the analysis system in this paper utilizes heterogeneous media. The media defined in this paper refers to recording text-based data, displaying data as image or video and visualizing data. The proposed analysis system classifies and stores data that transmitted and received between radar devices, radar target detection and Tracking algorithm data, etc. also displays and visualizes radar operation results and equipment defect information in real time. With this analysis system, it can quickly provide information what user want and assistance in developing high quality radar.

Kinematical Analysis of Swing Motion with Golf Iron Clubs Used by Elite Golfers (우수 골퍼의 아이언 클럽 스윙동작에 대한 운동학적 분석)

  • Kim, Kab-Sun
    • Korean Journal of Applied Biomechanics
    • /
    • v.18 no.2
    • /
    • pp.85-94
    • /
    • 2008
  • The purpose of this study is to provide basic materials for amateur golf players or golf maniacs to learn desirable iron swing motions. This study compared and analyzed the swing motions of iron clubs(3, 6, 9) by using 3-D in three elite golf players. 1. There was no a great difference in the total of swing time by club and the time by phase was nearly similar. 2. There was no a difference in the change in a head location at address and impact by club. 3. The angle change in a right knee joint was similar by club except the difference according to the length of the club. 4. There was a subtle difference in hip rotation angle by club. 5. In each club, the same rotation angle of shoulder joint at address and impact motions contributed to accurate swing, and the maintenance of more than $90^{\circ}$ of shoulder rotation angle in top swing increased swing rotation. 6. Although subtle, the forward angle of upper body was increased with a shorter club. $30-36^{\circ}$ of forward angle of upper body was maintained at address, top swing, and impact motions.

An Analysis on the Sinking Resistance of Purse Seine - 2. In the Case of the Model Purse Seine with Different Netting Material and Sinkers - (旋網의 沈降 抵抗 解析 - 2. 網地材料와 沈子量 다른 模型網의 경우 -)

  • Kim, Suk-Jong
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.40 no.1
    • /
    • pp.29-36
    • /
    • 2004
  • This study deals with an analysis on the sinking resistance for the model purse seine, in the case of different netting material and sinkers. The experiment was carried out using rune simplified model seines of knotless nettings. Dimension of model seines 420cm for corkline and 85cm for seine depth, three groups of models rigged 25, 45 and 60g with the same weighted sinkers in water were used. These were named PP-25, PA-25, PES-25, PP-45, PA-45, PES-45, PP-60, PA-60 and PES-60 seine. The densitie($\rho$) of netting materials were 0.91g/cm$cm^3$, 1.14g/cm$cm^3$ and 1.38g/cm$m^3$. Experiments carried out in the observation channel in a flume tank under still water conditions. Sinking motion was recorded by the one set of TV-camera for VTR, and reading coordinate carried out by the video digitization system. Differential equations were derived from the conservation of momenta of the model purse seines and used to determine the sinking speeds of the depths of leadline and the other portions of the seines. An analysis carried out by simultaneous differential equations for numerical method by sub-routine Runge-Kutta-Gill The results obtained were as follows : 1. Average sinking speed of leadline for the model seines rigged 60g with the same weighted sinkers in water was fastest for 12.2cm/sec of PES seine, followed by 11.4cm/sec of PA and 10.7cm/sec of PP seines. 2. The coefficient of resistance for netting of seine was estimated to be $K_D=0.09(\frac{\rho}{\rho_w})^4$ 3. The coefficient of resistance for netting bundle of seine was estimated to be $C_R=0.91(\frac{\rho}{\rho_w})$ 4. In all seines, the calculated depths of leadline closely agreed with the measured ones, each 25g, 45g, 60g of weighted sinkers were put into formulas meas.=1.04cal., meas.=0.99cal. and meas.=0.98 cal.