• Title/Summary/Keyword: 3D ultrasound

Search Result 159, Processing Time 0.025 seconds

Emulation of Tri-Phasic Pulsatile Flow Using LVAD (좌심실 보조기를 이용한 3단계 박동성 혈류 모의)

  • Lee, D.H.;Choi, J.S.;Chung, H.W.;Chung, M.J.;Kim, J.H.;Park, J.H.;Han, M.C.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.77-81
    • /
    • 1996
  • To emulate tri-phasic pulsatile flow of human circulatary system, we have selected control parameters and examined the changing effect of each parameter by using Doppler ultrasound. In this experiment, it was shown that the distal complaince and the break time were the major factors to form tri-phasic flow.

  • PDF

A Randomized Comparative Study of Unani Formulations in Abnormal Uterine Bleeding due to Endometrial Hyperplasia

  • Abothu Suhasini;Wasia Naveed;Arshiya sultana;Shahzadi Sultana
    • CELLMED
    • /
    • v.13 no.14
    • /
    • pp.19.1-19.16
    • /
    • 2023
  • Objectives: To compare the efficacy of polyherbal Unani formulations in heavy menstrual bleeding due to endometrial hyperplasia. Methodology: A prospective, randomized comparative trial was conducted at Govt. Nizamia Tibbi College. Group A (n=20) received Itrifal Aftimoon 5g orally BID from menstruation day 3 to day 21 plus suprapubic Marham Dakhilyun application and per vaginally Marham Dakhilyun (5g) and Roghan Gul (10ml) application from menstruation day 5 to day 14. Group B (n=20) received Gulnar Farsi (2g), Phitakri Biryan (0.25g), Dammul Aqwain (0.25g), and Geru (2g), 2.5g powder orally BID, menstruation day 3 for 20 days plus Douche Bargh Sambhalu then Ḥamūl of Safuf Mazu (2g), Kalijiri (2g) and Roghan Gul (10ml) from menstruation day 3 to day 12 for 3 consecutive cycles. The primary outcome was pelvic ultrasound findings of endometrial thickness. The secondary outcome measures were improvement in haemoglobin percentage, change in menstrual flow and menstrual pattern. The level of significance was 5%. Results and conclusion: The intragroup comparison showed that the mean endometrial thickness at baseline and after treatment in groups A and B was extremely significantly different (P<0.0001). The intragroup comparison showed the mean haemoglobin percent at baseline and after treatment in group, A was significantly different (P<0.0001). After treatment, 50% and 60% of participants had normal duration and menstrual blood loss after treatment from baseline in Groups A and B respectively. However, further, phase II and III randomized standard controlled trials in larger samples are recommended to assess the efficacy of these group medicines.

The Study on Ultrasound Physical Characteristic and Synthesis of Tissue Mimicking Materials Used New Materials (신소재를 사용한 인체조직모사물질의 합성과 초음파 물리적 특성에 관한 연구)

  • Ma, Sang-Chull;Kim, Hwa-Sun;Ann, Young-Man
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.245-252
    • /
    • 2010
  • This study analyzed speed of sound, impedance, attenuation coefficient in accordance with acoustic characteristic standard of body soft tissue corresponding with Annex DD of IEC standard 60601-2-37(2007) which is about tissue mimicking materials (TMM) synthesized by polyurethane as a main material and new type of n-type scatter materials. This study reached the following conclusion after analyzing and evaluating image characteristic with SONOACE 9900 c PRIME (MEDESON Co.) and brightness, maximum penetration with convex probe (2.5~5.0 MHz). When n-type scatter materials are increasingly synthesised 0~8% with prepolymer as a main material and polyol mixture as a catalyst, 1. The more scatter materials are increased, the more sound speed of TMM becomes closely similar to soft tissue. 2. The more scatter materials are decreased, the more acoustic impedance becomes closely similar to soft tissue. 3. The more scatter materials are increased, the more attenuation coefficient is increased. 4. The more scatter materials are increased, the more average brightness of images is increased, but there is threshold. 5. The maximum penetration becomes closely similar to soft tissue at the 6% TMM as a scatter material.

Blood Flow Simulation in Bifurcated Geometry of Abdominal and Iliac Arteries Based on CT Images (CT영상에 기반한 복부대동맥과 장골동맥 분기관 모델의 혈류유동 해석)

  • Hong Y. S.;Kim M. C.;Kang H. M.;Lee C. S.;Kim C. J.;Lee J. M.;Kim D. S.;Lee K.
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • Numerical simulation of blood flow has been conducted based on real vessel geometries generated front DICOM medical images of abdominal and iliac bifurcated arteries of a healthy man. A program was developed to read cross sectional images of the three dimensional arteries and smoothly extract boundary coordinates of vessels. Commercial programs were employed for mesh generation and flow simulation. Pressures, velocities, and flow distributions were found to lie within normal physiological ranges. Peak velocity measured in the iliac artery by ultrasound was 20% smaller than that obtained by simulation. The trend of velocity variation in a cardiac cycle was fairly similar between the simulation and the ultrasonic measurements. Simulation based on real vessel geometry of individual patient provides information on pressure, velocity, and its distribution in the diseased arteries or arteries to be surgically treated. The results of simulation may help surgeons to better understand hemodynamic status and surgical need of the patient by revealing variation of the hemodynamic parameters. Futhermore, they may serve as basic data for surgical treatment of arteries. This research is expected to develop to a program in the future that early diagnose atherosclerosis by showing distribution of a hemodynamic index closely related to atherosclerosis in arteries.

The Study for Correlation Characteristics on Radial Artery and Floating/sinking Pulse with BMI (BMI에 따른 요골동맥의 혈관특성과 부/침맥과의 상관관계 연구)

  • Lee, Yu-Jung;Lee, Jeon;Lee, Hae-Jung;Kim, Jong-Yeol
    • Korean Journal of Oriental Medicine
    • /
    • v.14 no.3
    • /
    • pp.121-126
    • /
    • 2008
  • Pulse diagnosis refers to the process of diagnosing a patient by feeling an artery on the wrist based on the shape that the pulse take s while the hold-down pressure increase. The styloid process artery on the wrist is usually felt, and the pulse is taken on Chon, Gwan and Cheok using three fingers. This study is to examine the structural difference in the location of pulse diagnosis by measuring and analyzing blood diameter, blood depth, and blood flow velocity of the location of pulse diagnosis by using ultrasonic wave (VOLUSION730 PRO, GE Medical, U.S.A). This study also attempted to grasp whether the characteristics of blood vessels differ depending on Body Mass Index (BMI) and analyzed their correlation with Oriental medical pulse diagnosis. The male subjects without cardiovascular diseases were divided into the normal BMI group, the underweight group and the overweight group and 10 people of each group were measured, Blood depth, blood diameter and blood flow velocity at the location of pulse diagnosis (Chon, Gwan, Cheok) of the wrists of left and right hands were measured and the pulse wave was measured by using pulse diagnosis instrument (3-D Mac, DaeyoMedi, Korea).The results of this study showed that the characteristics of blood vessels differ depending on the degrees of obesity, and the characteristics of floating pulse and sinking pulse of Oriental medical pulses were related to the degrees of obesity. This shows that the characteristics of the blood vessels of subjects and BMI information are the major indicators for diagnosis and are the matters that must always be considered when developing the algorithm of pulse diagnosis.

  • PDF

Effect of a Baseline Ovarian Cyst on the Outcome of in Vitro Fertilization-embryo Transfer (과배란유도 전 기저 난소 낭종이 체외수정시술 결과에 미치는 영향)

  • Bai, S.W.;Lee, K.J.;Lee, B.S.;Park, K.H.;Cho, D.J.;Song, C.H.
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.26 no.2
    • /
    • pp.179-183
    • /
    • 1999
  • This study was performed to determine the significance of a baseline ovarian cyst on the response to controlled ovarian hyperstimulation and the outcome of IVF-ET. One hundred one patients who underwent IVF-ET were enrolled in this study. The outcome of 31 patients, who had an ovarian cyst of >10mm detected at ultrasound examination performed on day 3, was compared with that of 70 patients who underwent a similar protocol and did not have an ovarian cyst. E2 level on the day of hCG administration, the number of follicles, the number of oocytes retrieved, the number of embryo transferred and the pregnancy rate were evaulated. The E2 level on the day of hCG adminstration and the number of mature oocytes retrieved were lower in the group with a baseline cyst. The pregnancy rate also was significantly lower in the group with a cyst (21% versus 38%). Therefore a baseline ovarian cyst on cycle day 3 was associated with a poorer outcome after IVF-ET.

  • PDF

Human lactoferrin efficiently targeted into caprine beta-lactoglobulin locus with transcription activator-like effector nucleases

  • Yuan, Yu-Guo;Song, Shao-Zheng;Zhu, Meng-Ming;He, Zheng-Yi;Lu, Rui;Zhang, Ting;Mi, Fei;Wang, Jin-Yu;Cheng, Yong
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.8
    • /
    • pp.1175-1182
    • /
    • 2017
  • Objective: To create genetically modified goat as a biopharming source of recombinant human lacotoferrin (hLF) with transcription activator-like effector nucleases. Methods: TALENs and targeting vector were transferred into cultured fibroblasts to insert hLF cDNA in the goat beta-lactoglobulin (BLG) locus with homology-directed repair. The gene targeted efficiency was checked using sequencing and TE7I assay. The bi-allelic gene targeted colonies were isolated and confirmed with polymerase chain reaction, and used as donor cells for somatic cell nuclear transfer (SCNT). Results: The targeted efficiency for BLG gene was approximately 10%. Among 12 Bi-allelic gene targeted colonies, five were used in first round SCNT and 4 recipients (23%) were confirmed pregnant at 30 d. In second round SCNT, 7 (53%), 4 (31%), and 3 (23%) recipients were confirmed to be pregnant by ultrasound on 30 d, 60 d, and 90 d. Conclusion: This finding signifies the combined use of TALENs and SCNT can generate biallelic knock-in fibroblasts that can be cloned in a fetus. Therefore, it might lay the foundation for transgenic hLF goat generation and possible use of their mammary gland as a bioreactor for large-scale production of recombinant hLF.

Reproducibiity of setup error for prostate cancer by ultrasound image-guided radiation therapy (전립선암에 대한 초음파 영상유도 방사선치료의 Setup 오차 분석을 통한 재현성 평가)

  • Park, Sung Yong;Lim, Seung Kyu;Si, Myoung Geun;Lee, Ji Hae;Kim, Jong Yeol;Cho, Eun Joo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.75-81
    • /
    • 2017
  • Purpose: To evaluate the reproducibility of image-guided radiotherapy using ultrasonography which is non-invasive, without radiation exposure for prostate cancer patients. Materials and Methods: We analyzed the setup variation of 1,105 images for 26 prostate cancer patients and the mean, standard deviation and 3D-error in AP, RL and SI directions. Setup variations were classified 0-1 mm, 1-3 mm, 3-5 mm, 5 mm and more. Results: The mean and standard deviation of setup variation in AP, RL and SI directions was $1.87{\pm}1.36mm$, $1.73{\pm}1.22mm$ and $2.01{\pm}1.40mm$. The 3D-error in AP, RL and SI directions was $3.63{\pm}1.63mm$. The frequency of setup variation in AP direction was 29 % in the range from 0 mm to 1 mm, 50.2 % in the range from 1 mm to 3 mm, 19.6 % in the range from 3 mm to 5 mm and 1.3 % in the range of 5 mm or more. In RL direction, the frequency was 31.3 % in the range from 0 mm to 1 mm, 52.5 % in the range from 1 mm to 3 mm, 15.8 % in the range from 3 mm to 5 mm and 0.5 % in the range of 5 mm or more. SI direction, the frequency of errors in the range from 0 mm to 1 mm was 26.3 %, 50.2 % in the range from 1 mm to 3 mm, 22.4 % in the range from 3 mm to 5 mm, and 1.1 % in the range of 5 mm or more. Conclusion: The setup error was highest in the SI direction of $2.01{\pm}1.40mm$. The frequency in each direction was the highest in more than 50 % in the range from 1 mm to 3 mm. $Clarity^{TM}$ Auto scan is possible to monitoring the motion of the prostate during the treatment and to repositioning the patient. In conclusion real-time image-guided radiotherapy using ultrasonography will be increase the reproducibility of radiation therapy.

  • PDF

2D Backtracking Method of Ultrasonic Signal (초음파 신호의 2차원 역추적 방법에 관한 연구)

  • Kyu-Joung Lee;Choong Ho Lee
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.24 no.3
    • /
    • pp.172-177
    • /
    • 2023
  • In this paper, 2-dimensional backtracking method for ultrasonic signals. Ultrasonic sensors are a common technology used in industrial fields as many studies have been conducted on distance measurement and indoor location tracking using transmission and reception devices in pairs. A method for tracking a signal of an arbitrary ultrasonic transmission device on a 2D plane using only a receiver of an ultrasonic signal is proposed. In order to track the ultrasonic signal, the receiver receives the signal by making at least three. The three receivers may calculate a direction and a distance using a time difference in which the ultrasound reception sound is reached. The existing method of tracking signal sources using ultrasonic waves has a problem of time synchronization of devices because the transceivers must be paired or installed independently for each sensor. In order to solve this problem, the distance of the ultrasonic receiver is minimized, and it is configured as one device. The sensor installed as one device may be processed by one operator, thereby solving the time synchronization problem. To increase time difference accuracy, high-speed 32-bit timers with high time resolution can be used to quickly calculate and track distances and directions.

The Study on Nutritional Status, Bone Mineral Density and Plasma Mineral Concentrations of Smoking Male Adults (남자성인의 흡연여부에 따른 영양섭취상태, 골밀도, 혈장 무기질 농도에 관한 연구)

  • Sung Chung-Ja;Bae Yun-Jung
    • Korean Journal of Community Nutrition
    • /
    • v.10 no.1
    • /
    • pp.91-100
    • /
    • 2005
  • This study was conducted to investigate the effects of smoking on nutrition intake, bone mineral density and blood mineral status. The subjects were composed of two groups: 100 smokers and 100 non-smokers was used along with a questionnaire. Anthropometric measurements, dietary intakes using 24-hours recall method were compared. At twenty subjects from each group were selected, bone mineral density were measured by quantitative ultrasound and plasma mineral levels were analyzed by ICP spectrometer. The average ages of smokers and non-smokers were 23.9 and 22.8 years old, respectively. The height, weight and BMI of the smokers were no significant difference. The average numbers of smoked cigarettes were 11.8/d and the average packyear was 3.1 in the smokers. About $97\%$ of the smokers drank alcoholic beverages, while $85\%$ of the non-smokers did. The smokers tended to eat less meals and dinner meal, but drink coffee more often compared to the non-smokers. The mean daily energy intake and CPF energy intake ratio were 2184. 9 kcal and 57.2 : 13.7 : 26.4 in the smokers and 2262.6 kcal and 55.8 : 13.1 : 28.6 in the non-smokers. The smokers consumed significantly lower intake of $\beta$-carotene. There were no significant differences in bone mineral density of BUA, SOS and QUI. There were no significant differences in plasma levels of Ca, Mg, Fe and Zn. However, plasma Cu level of the smokers was significantly higher than that of the non-smokers. In conclusion, the smokers of this study showed a more undesirable dietary intake in the light of their low ,B -carotene and high alcoholic beverages, and coffee. The plasma Cu level of the smokers was higher than that of the non-smokers, showing that Cu is involved in smoking. Therefore, it could be suggested that more systematic research be conducted with respect to Cu and smoking and that increased nutrition education and guidelines for smokers are required.