• Title/Summary/Keyword: 3D ultrasound

Search Result 159, Processing Time 0.026 seconds

Correlation between Results of Preoperative Impingement Test and Clinical Outcomes after Arthroscopic Rotator Cuff Repair

  • Park, Sung Bae;Seo, Joong Bae;Ryu, Jee Won;Shin, Yong Eun
    • Clinics in Shoulder and Elbow
    • /
    • v.20 no.3
    • /
    • pp.126-132
    • /
    • 2017
  • Background: The aim of the present study was to determine the correlation between the amount of pain reduction after local anesthetic injection into the subacromial space preoperatively and clinical outcome after arthroscopic rotator cuff repair. Methods: A total of 127 patients who underwent arthroscopic rotator cuff repair and followed up at least 1 year were analyzed retrospectively. Preoperatively, a visual analogue scale (VAS) for pain was measured in all patients before and after the ultrasound guided impingement test. The participants were divied into four groups according to pain reduntion ater impingement test (Group A: >75%, Group B: 50%-75%, Group C: 25%-50%, Group D: <25%). VAS for pain, shoulder range of motion, shoulder isometric strength, ASES score were evaluated preoperatively and at 3, 6, 9, and 12 months postoperatively. Results: After surgery, the amount of pain reduction shows significantly at 3, 6 months in Groups A, B as compared to Groups C, D (p<0.05). Among the range of motion of shoulder joint, forward flexion was significantly improved in Group A at 3 months (p<0.05). The ASES score significantly improved at 3, 6 months in Groups A, B as compared to Group C, D (p<0.05). Conclusions: Preoperative degree of pain reduction after impingement test correlates with the improvement of pain after arthroscopic rotator cuff repair, especially in the early phase. Therefore, the impingement test could be effectively used.

Adductor canal block versus intra-articular steroid and lidocaine injection for knee osteoarthritis: a randomized controlled study

  • Ming, Lee Hwee;Chin, Chan Soo;Yang, Chung Tze;Suhaimi, Anwar
    • The Korean Journal of Pain
    • /
    • v.35 no.2
    • /
    • pp.191-201
    • /
    • 2022
  • Background: This study aimed to assess the efficacy of the adductor canal block (ACB) in comparison to intra-articular steroid-lidocaine injection (IASLI) to control chronic knee osteoarthritis (KOA) pain. Methods: A randomized, single-blinded trial in an outpatient rehabilitation clinic recruiting chronic KOA with pain ≥ 6 months over one year. Following randomization, subjects received either a single ACB or IASLI under ultrasound guidance. Numerical rating scale (NRS) scores for pain, and Knee Injury and Osteoarthritis Outcome Scores (KOOS) were recorded at baseline, 1 hour, 1 month, and 3 months postinjection. Results: Sixty-six knees were recruited; 2 were lost to follow-up. Age was normally distributed (P = 0.463), with more female subjects in both arms (P = 0.564). NRS scores improved significantly for both arms at 1 hour, with better pain scores for the IASLI arm (P = 0.416) at 1st month and ACB arm at 3rd month (P = 0.077) with larger effect size (Cohen's d = 1.085). Lower limb function improved significantly in the IASLI arm at 1 month; the ACB subjects showed greater functional improvement at 3 months (Cohen's d = 0.3, P = 0.346). Quality of life (QoL) improvement mirrored the functional scores whereby the IASLI group fared better at the 1st month (P = 0.071) but at the 3rd month the ACB group scored better (Cohen's d = 0.08, P = 0.710). Conclusions: ACB provides longer lasting analgesia which improves function and QoL in chronic KOA patients up to 3 months without any significant side effects.

Evaluation of Liver Function and Blood Exam including hs-CRP in Adults with Nonalcoholic Fatty Liver Findings (비알코올성 지방간 소견을 보이는 성인에 대한 간 기능 및 hs-CRP 혈액 검사 항목 평가)

  • Jeong-Mi, Park;Young-Hyun, Seo;Jong-Nam ,Song
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.943-952
    • /
    • 2022
  • As a test for diagnosing fatty liver, recently, ultrasound and blood exam are being performed simultaneously. In particular, in the case of high-sensitivity C-reactive protein in blood exam, it is used as an index indicating the level of inflammation in various parts of the body as well as cardiovascular diseases. Thus, this study was conducted to analyze the association between metabolic syndrome components, liver function, and high-sensitivity C-reactive protein levels according to the degree of nonalcoholic fatty liver, and use it as a clinical indicator for fatty liver diagnosis. Metabolic syndrome components, liver function and high-sensitivity C-reactive protein blood test values analyzed from 1,139 men and women over 20 years of age with nonalcoholic fatty liver in abdominal ultrasonography from March 2021 to August 2021 at the Korea Association of Health Promotion, Gwangju-Jeonnam Branch. Analyzed for all men and women, the blood test values for subjects with mild fatty liver were AST 30 U/L, ALT 32.1 U/L, γ-GTP 41.2 IU/L, and hs-CRP 0.14 mg/dL. These values were lower than the blood test values of subjects with moderate fatty liver (AST 38 U/L, ALT 47.6 U/L, γ-GTP 54.9 IU/L, hs-CRP 0.22 mg/dL) and was statistically significant (p<0.001). In this case of high-sensitivity C-reactive protein test, it is statistically significant, showing higher values in Subjects with moderate fatty liver than Subjects with mild fatty liver. thus, it is considered that hs-CRP can be used as clinical data for the prevention and management of fatty liver.

The Study on the Factors for Detection of Renal Stone on Ultrasound (초음파 검사에서 신장 결석의 검출 요인에 관한 연구)

  • Sim, Hyun-Sun;Jung, Hong-Ryang;Lim, Cheong-Hwan
    • Journal of radiological science and technology
    • /
    • v.29 no.1
    • /
    • pp.1-6
    • /
    • 2006
  • Purpose: Renal stones are common and typically arise within the collecting system. The renal sinus are contains the collection system, the renal vessels, lymphatcs, fat, and fibrous tissue. Because of the compression of all the large echoes in signal processing, the echo from the renal stone generally cannot be distinguished from large echoes emanating from normal structures of the renal sinus. Use of ultrasonography has been difficult for detecting small renal stone without posterior shadowing and chemical composition of stone. The aim of study was measuring for posterior acoustic shadowing to a stone for various scan parameter and it examines a help in renal stone diagnosis. Material & Methods: The stone was place on sponge examined in a water bath with a 3.5MHz or 7.5MHz transducer(LOGIQ 400, USA). First, tested a variety of gain. Second, tested a variety of dynamic range. Third, tested a variety of focal zone. Fourth, measuring of the echo level for low and high frequency for depth. Results: 1) Average echo level was 98 for low total gain(10 dB) and was 142 for high total gain(40 dB). Posterior acoustic shadowing of renal stone was clear for low gain. 2) Average echo level was 129 for low dynamic range(42 dB) and was 101 for high dynamic range(72 dB). Posterior acoustic shadowing of renal stone was clear for high dynamic range. 3) When stone is in focal zone of transducer, definite posterior acoustic shadow is identified. 4) Stone was clear appeared for high frequency(7.5 MHz) than low frequency(3.5 MHz) and it is not distorted. Conclusion: The demonstration of an posterior acoustic shadow of renal stone dependents on several technical factors such as gain, dynamic range, focus, and frequency. This various factors are a help in renal stone diagnosis.

  • PDF

Bladder Volume Variations in Patients Receiving Conformal Radiotherapy to Prostate (전립선암 환자의 방사선 치료 시 방광 체적 변화)

  • Lee, Re-Na;Lee, Ji-Hye;Lee, Kyung-Ja;Ji, Young-Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.61-65
    • /
    • 2008
  • Objective: To reduce urinary side effects in prostate cancer patients receiving radiation, patients were asked to drink certain amount of water to maintain bladder volume constant and the bladder volumes were measured weekly using ultrasound scanner. Materials and Methods: Twenty-six patients with prostate cancer who received radiation between December 2002 and August 2007 were enrolled in this study. Thirteen patients were enrolled in experimental group. These patients were asked to drink 450 cc of water, one hour prior to simulation, CT scan, and treatment. The other thirteen patients were given no information about bladder filing. Bladder, prostate, and rectum were contoured on CT and volumes were calculated. 3D conformal treatment planning was performed and effective volumes of bladder were calculated when a prescription dose of 70.2 Gy was delivered. For the patients in experimental group, bladder volumes were measured weekly using ultrasound scanner for 6-8 weeks and the bladder volume variations were analyzed. Results: Average bladder volumes and standard deviations obtained at CT scanning were $283.5{\pm}114.0\;cc$ (40%) and $181.2{\pm}120.1\;cc$ (66%) in experimental and control groups, respectively. Although it was not statistically significant, there was correlation between the bladder volumes measured from CT and ultrasound. The volumes measured using ultrasound scanner were 62% lower than the volumes using CT images on average. There was significant variations in volumes measured weekly for 6-8 weeks. It ranged between 33 - 75 %. Conclusion: Our results showed that it is possible to obtain larger bladder volume if they are asked to drink certain amount of water prior to CT scan. However, patients were unable to maintain constant bladder volumes over the 6-8 weeks of treatment period although they were asked to drink constant amount of water.

첨단기술 기반기업(NTBF)의 성장 요인 분석 - 역동적 기업 역량(DFC)의 시각에서 -

  • Son, Chan;Chung, Jae-Yong
    • Proceedings of the Korea Technology Innovation Society Conference
    • /
    • 2003.05a
    • /
    • pp.369-388
    • /
    • 2003
  • This research has been focused upon and analyzing Medison, once a leading New Technology-Based Firm (NTBF) in Korea with exceptionally advanced technology in 3D ultrasound diagnostic imaging devices (UDIDs) (armored with 23 subsidiaries at its peak expansion), from the perspective if Dynamic Firm Capability(DFC). The underlying hypothesis is that the various problems from its pointless pursuit of the business styles or precedents of the existing large firms might be traced to its specific characteristics as an NTBF, which should have more preferably been based upon the distinctive competences such as differentiated technologies, institutional linkages, organizational routines, and complementary assets, etc. In conclusion, for the NTBFs with different DFC domains from those of the large firms, the optimal external linkages and comprehensive integration efforts (Process) under their specific organizational characteristics and constraints (Path) are highly recommended for the continuous accumulation of their core capabilities based upon the technological assets (Position).

  • PDF

Generation of Thermoelastic Waves by Irradiating a Metal Slab with a Line-Focused Laser Pulse

  • Yoo, Jae-Gwon;Baik, S.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.3
    • /
    • pp.181-189
    • /
    • 2006
  • A 2D finite-element numerical simulation has been developed to investigate the generation of ultrasonic waves in a homogeneous isotropic elastic slab under a line-focused laser irradiation. Discussing the physical processes involved in the thermoelastic phenomena, we describe a model for the pulsed laser generation of ultrasound in a metal slab. Addressing an analytic method, on the basis of an integral transform technique, for obtaining the solutions of the elastodynamic equation, we outline a finite element method for a numerical simulation of an ultrasonic wave propagation. We present the numerical results for the displacements and the stresses generated by a line-focused laser pulse on the surface of a stainless steel slab.

Impeding on NTBF′s Sustainable Growth: The Case of Medison (첨단기술 기반기업(NTBF)의 지속적 성장을 저해하는 주요 요인 분석 -역동적 기업 역량(DFC)의 시각에서-)

  • Son, Chan;Chung, Jae-Yong
    • Journal of Korea Technology Innovation Society
    • /
    • v.6 no.2
    • /
    • pp.228-252
    • /
    • 2003
  • This research has been focused upon and analyzing Medison, once a leading New Technology-Based Finn (N1BF) in Korea with exceptionally advanced technology in 3D ultrasound diagnostic imaging devices (UDIDs) (armored with 23 subsidiaries at its peak expansion), from the perspective of Dynamic Finn Capability(DFC). The underlying hypothesis is that the various problems from its pointless pursuit of the business styles or precedents of the existing large firms might be traced to its specific characteristics as an NTBF, which should have more preferably been based upon the distinctive competences such as differentiated technologies, institutional linkages, organizational routines, and complementary assets, etc. In conclusion, for the NTBFs with different DFC domains from those of the large firms, the optimal external linkages and comprehensive integration efforts (Process) under their specific organizational characteristics and constraints (path) are highly recommended for the continuous accumulation of their core capabilities based upon the technological assets (Position).

  • PDF

Requirements for Future Digital Radiology System

  • Kim, Y.M.;Park, H.W.;Haynor, D.R.
    • Progress in Medical Physics
    • /
    • v.2 no.1
    • /
    • pp.3-16
    • /
    • 1991
  • Abstract. An area of particularly rapid technological growth in the last 15 years has been medical imaging (conventional X-ray, ultrasound, X-ray computed tomography (CT), magnetic resonance imaging (MRI). As the number and complexity of imaging studies rises, it becomes ever more important to distribute these images and the associated diagnoses in a timely and cost-effective fashion. The purpose of this paper is to describe the requirements for a future digital radiology system which will efficiently handle the large volume of images that generated, add new functionality to improve productivity of physicians, technologists, and other health care providers, and provide enough flexibility to allow the system to grow as medical image technology grows.

  • PDF

New insights into pathways of the accessory nerve and transverse cervical artery for distal selective accessory nerve blockade

  • Heo, Yanguk;Cho, Namju;Cho, Hyunho;Won, Hyung-Sun;Yang, Miyoung;Kim, Yeon-Dong
    • The Korean Journal of Pain
    • /
    • v.33 no.1
    • /
    • pp.48-53
    • /
    • 2020
  • Background: The aim of this study was to clarify the topographical relationship between the accessory nerve (AN) and transverse cervical artery (TCA) to provide safe and convenient injection points for AN blockade. Methods: This study included 21 and 30 shoulders of 14 embalmed Korean adult cadavers and 15 patients, respectively, for dissection and ultrasound (US) examination. Results: The courses of the TCA and AN in the scapular region were classified into four types based on their positional relationships. Type A indicated the nerve that was medial to the artery and ran parallel without changing its location (38%). In type B (38%), the nerve was lateral to the artery and ran parallel without changing its location. In type C (19%), the nerve or artery traversed each other only once during the whole course. In type D (5%), the nerve or artery traversed each other more than twice forming a twist. At the levels of lines I-IV, the nerve was relatively close to the artery (approximately 10 mm). TCAs were observed in all specimens around the superior angle of the scapula at the level of line II, whereas they were not found below line VI. In US images of the patients, the TCA was commonly observed at the level of line II (93.3%) where all ANs and TCAs were observed in cadaveric dissection. Conclusions: The results expand the current knowledge of the relation between the AN and TCA, and provide helpful information for selective diagnostic nerve blocks in the scapular region.