• Title/Summary/Keyword: 3D shapes

Search Result 945, Processing Time 0.03 seconds

On-line Image Guided Radiation Therapy using Cone-Beam CT (CBCT) (콘빔CT (CBCT)를 이용한 온라인 영상유도방사선치료 (On-line Image Guided Radiation Therapy))

  • Bak, Jin-O;Jeong, Kyoung-Keun;Keum, Ki-Chang;Park, Suk-Won
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.294-299
    • /
    • 2006
  • $\underline{Purpose}$: Using cone beam CT, we can compare the position of the patients at the simulation and the treatment. In on-line image guided radiation therapy, one can utilize this compared data and correct the patient position before treatments. Using cone beam CT, we investigated the errors induced by setting up the patients when use only the markings on the patients' skin. $\underline{Materials\;and\;Methods}$: We obtained the data of three patients that received radiation therapy at the Department of Radiation Oncology in Chung-Ang University during August 2006 and October 2006. Just as normal radiation therapy, patients were aligned on the treatment couch after the simulation and treatment planning. Patients were aligned with lasers according to the marking on the skin that were marked at the simulation time and then cone beam CTs were obtained. Cone beam CTs were fused and compared with simulation CTs and the displacement vectors were calculated. Treatment couches were adjusted according to the displacement vector before treatments. After the treatment, positions were verified with kV X-ray (OBI system). $\underline{Results}$: In the case of head and neck patients, the average sizes of the setup error vectors, given by the cone beam CT, were 0.19 cm for the patient A and 0.18 cm for the patient B. The standard deviations were 0.15 cm and 0.21 cm, each. On the other hand, in the case of the pelvis patient, the average and the standard deviation were 0.37 cm and 0.1 cm. $\underline{Conclusion}$: Through the on-line IGRT using cone beam CT, we could correct the setup errors that could occur in the conventional radiotherapy. The importance of the on-line IGRT should be emphasized in the case of 3D conformal therapy and intensity-modulated radiotherapy, which have complex target shapes and steep dose gradients.

Analysis for the Idiopathic Facial Palsy Inpatients According to Distribution of Sasang Constitution, Hyungsang Classification and Assessment Tools (특발성 안면신경마비 환자에 대한 사상체질.형상별 분포 및 평가도구에 따른 분석)

  • Lee, Seung Hwon;Lee, Eun Sol;Seo, Dong Kyun;Lee, Kyeong A;Kim, Jung Hee;Hong, Chang Ho;Jang, Sun Hee;Youn, Hyoun Min;Jang, Kyung Jeon;Song, Choon Ho;Kim, Cheol Hong
    • Journal of Acupuncture Research
    • /
    • v.30 no.4
    • /
    • pp.55-68
    • /
    • 2013
  • Objectives : The purpose of this study is to analyze the distribution, relationship, prognosis and improvement score of idiopathic facial palsy inpatients according to constitutional differentiation ; Sasang constition, Hyungsang classification, Sasang constition combined with Hyungsang classification. Methods : A study was done on 102 patients who were diagnosed and treated as idiopathic facial palsy from April 2012 to Nomember 2012 at the Department of Acupuncture and Moxibution Medicine, Dong-eui Oriental University Hospital. Medical records of inpatinets who underwent facial ENoG, NET test were analyzed. Changes of HBGS grade and Yanagihara's score were also evaluated. We classified inpaients acording to Sasang constitution by consulting to Department of Sasang constitutinal medicine, and to Hyungsang classification(Dam-body, Bangkwang-body) by measuring under medical system of 3D facial shapes(RS-400FL). The constitutional differentiation and general characteristics were initially analyzed, and valuse on ENoG, NET were correlated with constitutinal differentiation. Results of HBGS and Yanagihara's score were also correlated with constitutinal differentiation. Results : 1. Each 39.2 percent of idiopathic facial palsy inpatients were the Taeeumin and Soyangin, 21.6 percent were the Soeumin. 2. 75.5 percent of idiopathic facial palsy inpatients were the Bangkwang-body, 24.5 percent were the Dam-body. 3. 34.3 percent of idiopathic facial palsy inpatinets were the Taeeum-Bangkwang, 21.6 percent were the Soyang-Bangkwang, 19.6 percent were the Soeum-Bangkwang, 17.6 percent were the Soyang-Dam, 4.9 percent were the Taeem-Dam, 2 percent were the Soeum-Dam. 4. By sex, the each ratio of Taeeumin, Soeumin, Bangkwang-body, Taeeum-Bangkwang, Soeum-Bangkwang, Soyang-Bangkwang was higher in female, that of Dam-body, Taeeum-Dam, Soyang-Dam was higher in male. 5. By relations between Sasang constitution and Hyungsang classification, the each ratio of Taeeumin and Soeumin was higher in Bangkwang-body. 6. By values on ENoG and NET, evaluations of HBGS's grade and Yanagihara's score, there were no significant difference. Conclusions : In idiopathic facial palsy inpatients, the proportion of Taeeum and Soyang among the Sasang constitution was higher, that of Dam among the Hyungsang classification was higher, that of Taeeum-Bangkwang among the Sasang combined with Hyungsang was the highest. It would seem that Bangkwang-body, female were closely related to Taeeumin, Soeumin. Also, Dam-body were closely related to male. But when comparing groups, there was no statistically significant difference in prognosis and improvement.

Development of Independent Target Approximation by Auto-computation of 3-D Distribution Units for Stereotactic Radiosurgery (정위적 방사선 수술시 3차원적 공간상 단위분포들의 자동계산법에 의한 간접적 병소 근사화 방법의 개발)

  • Choi Kyoung Sik;Oh Seung Jong;Lee Jeong Woo;Kim Jeung Kee;Suh Tae Suk;Choe Bo Young;Kim Moon Chan;Chung Hyun-Tai
    • Progress in Medical Physics
    • /
    • v.16 no.1
    • /
    • pp.24-31
    • /
    • 2005
  • The stereotactic radiosurgery (SRS) describes a method of delivering a high dose of radiation to a small tar-get volume in the brain, generally in a single fraction, while the dose delivered to the surrounding normal tissue should be minimized. To perform automatic plan of the SRS, a new method of multi-isocenter/shot linear accelerator (linac) and gamma knife (GK) radiosurgery treatment plan was developed, based on a physical lattice structure in target. The optimal radiosurgical plan had been constructed by many beam parameters in a linear accelerator or gamma knife-based radiation therapy. In this work, an isocenter/shot was modeled as a sphere, which is equal to the circular collimator/helmet hole size because the dimension of the 50% isodose level in the dose profile is similar to its size. In a computer-aided system, it accomplished first an automatic arrangement of multi-isocenter/shot considering two parameters such as positions and collimator/helmet sizes for each isocenter/shot. Simultaneously, an irregularly shaped target was approximated by cubic structures through computation of voxel units. The treatment planning method by the technique was evaluated as a dose distribution by dose volume histograms, dose conformity, and dose homogeneity to targets. For irregularly shaped targets, the new method performed optimal multi-isocenter packing, and it only took a few seconds in a computer-aided system. The targets were included in a more than 50% isodose curve. The dose conformity was ordinarily acceptable levels and the dose homogeneity was always less than 2.0, satisfying for various targets referred to Radiation Therapy Oncology Group (RTOG) SRS criteria. In conclusion, this approach by physical lattice structure could be a useful radiosurgical plan without restrictions in the various tumor shapes and the different modality techniques such as linac and GK for SRS.

  • PDF

An Experimental Study on Evaluation of Axially Compressive Buckling Strength of Corroded Temporary Steel (부식 손상된 가시설 강재의 축압축 좌굴강도 추정에 관한 실험적 연구)

  • Kim, In Tae;Lee, Myoung Jin;Shin, Chang Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.15 no.6
    • /
    • pp.135-146
    • /
    • 2011
  • Steel structures have been generally painted to prevent corrosion damage. However, the painted film is deteriorated with increase in service life, and then corrosion damage resulting in cross sectional area occurs on steel surface. As a result, the buckling strength of steel structures can be decreased due to the corrosion damages. The evaluation method of the axial buckling strength of columns about a variety of section shapes and supporting conditions have been presented, but evaluation method of buckling strength about irregular nonprismatic columns is not established. In this study, the axial buckling strength of corroded steels was evaluated based on the buckling test results of corroded steel specimens that were cut off at a temporary steel structure. The corroded specimens were picked up total 10 specimens according to various slenderness ratio from the web of a temporary structure's main beam. The length of specimens is 200, 300, 400, 500 and 600mm respectively. The rust productions were removed by the chemical treatment. Then, the surface geometry was measured at intervals of $1{\times}1mm$ by using the optical 3D digitizing system, and the residual thickness of the specimens was calculated. The axial buckling test was performed on 10 corroded specimens and 12 non-corroded specimens under the fixed-fixed support condition. From the test results, the effect of corrosion damages on axial buckling load was investigated. Regardless of corrosion damage degree, the axial buckling strength of corroded specimens and non-corroded specimens was evaluated identically by using minimum average residual thickness or average residual thickness to minus its standard deviation. Reasonable measuring intervals of residual thickness was proposed by using the results to apply for practical works.

A Study on the Palsapum (八賜品, Eight-Bestowed Things), Treasure No. 440, in Tong-Yong Shrine to the Loyal Dead in Korea (보물 제440호 통영 충렬사 팔사품(八賜品) 연구)

  • Jang, Kyung-hee
    • Journal of Korean Historical Folklife
    • /
    • no.46
    • /
    • pp.195-237
    • /
    • 2014
  • Palsapum are ornaments to reveal the purpose of commander of three naval forces as well as symbols to remember the greatness of admiral Yi, Sun-Shin. In 1966, ther were designated as a treasure No. 440 based on their value; however, they have not received attention from academia because they are relics from China. This study compares and analyzes the document, paintings, and relevant references from Korea and China focusing on Palsapum, understands their formal characteristics, and examines their historical value such as years and location of creation. As a result, the study determines five of them are original, but three of them were newly created by the later generations. The five, Dodogin (都督印, Commander's seal)·Yeongpae (令牌, Commander's tablet)·Gwido (鬼刀, Replica of the devil sword)·Chamdo (斬刀, Replica of the decapitation swor d)·and Gognapal (bugle) were created by Ming Dynasty before 1598, and delivered by the hands of General Chen Lin. The other three, Dokjeongi (督戰 旗, Battle flag)·Hongsoryeonggi (紅小令旗, Commander's flag)·and Namsoryeonggi (藍小令旗, Commander's flag), were created in 19th century by Joseon Dynasty. After analysis on the former relics, the study determines that they are not official relics with the dignity of Ming Dynasty but personal relics with regional characteristics; in other words, Palsamun are not the royal gifts from Emperor Shenzong to Admiral Yi, Sun-Shin. but personal momentoes left by General Chen Lin in the Tongjeyoung to celebrate the admiral. The names, variety, numbers, and appurtenances of Palsapum have been changed with time as follows. First, the scholars of Jeseon in 17the century only focused on Dodogin. It was certainly created in Ming Dynasty; however, it was a personal stamp, so considered to be not from the emperor but from General Chen Lin. Second, Palsapum was called Palsamul and consisted of 14 pieces of 8 kinds in 18the century, ; it is confirmed on the 「Dosul(圖說, stories with pictures of」 『Yi Chungmugong Literary Collection』 The sizes of five relics including Dodogin are similar to the records, but their patterns and shapes are exotic, or cannot be found in Joseon. Thus, they reflect the regional characteristics of Guangdong province. Third, they were called Palsapum, and consisted on 15 pieces of 8 kinds in 19th century; it is confirmed on , a sixteen-fold folding screen drawn by Shin, Gwan-Ho in 1861. The stamp box, tablet bag, and three flags were newly created to engrave Joseon style letters and patterns on damageable materials such as leather and cloth. The relics easy to be destroyed have been renewed even after 19th century. Last, there are many misunderstandings about Palsapum by governmental indifference and improper management of records even though they were designated as a treasure in very early times. Thus, authorities should be concerned with Palsapum to provide the measures for stable maintenance of the relics; this will let people remember not only the history of cooperation between Korea and China to stop the Japanese ambition, but also Admiral Yi, Sun-Shin and General Chen Lin to bring victory in Japanese invasions of Korea.