• Title/Summary/Keyword: 3D profile measurement

Search Result 121, Processing Time 0.036 seconds

The Efficient Measurement Method of Buried Heritage by 3D Image Acquisition (3차원 영상취득에 의한 매장문화재의 효율적 측정기법)

  • Lee, Kye-Dong;Lee, Jae-Kee;Jung, Sung-Heuk
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.25 no.2
    • /
    • pp.157-163
    • /
    • 2007
  • Recently, industrialization of a country is accelerated and request of society infrastructure is raised so national land development is activity view. Accordingly, the search for a wide-ranging buried heritage do acted in large construction region. Because the buried heritage get buried in land that it is necessary to the precision search and research for a record and a preservation. Until now, Surveying techniques of a historic site have made status map, profile and cross section map through leveling survey, total-station survey and sketch of specialist. So, to solve problems existing relic survey or drawing making method have using digital camera these researches rapidly and economically obtain stereo image of object and present a technique that constructs 3D image model for digital photogrammetry method. Also, these researches construct 3D image model for record and preservation of a historic site through site test and in 3D and graphical express a historic site and support works that produce other maps if we need it. offer base data of GIS (Geographic Information System) to collect and analyze overall, information of a historic site.

Characteristics Analysis of Disk-type Single Phase SRM (Disk형 단상 스위치드 리럭턴스 전동기의 특성 해석)

  • Lee, Chung-Won;Lee, Eun-Woong;Lee, Jong-Han;Oh, Young-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.988-990
    • /
    • 2003
  • Disk type Single Phase SRM(Switched Reluctance Motor) can be used axial and radial direction magnetic flux. Therefore, the energy density per unit of volume is high and the axis can be shorter than that of any other motor. In this paper, the flux-linkage was measured according as rotor positions of disk type single phase SRM, which is designed and fabricated in previous studies. From the measured data, we got the magnetization curves, inductance profile, co-energy and torque. Also, we compared the value of the measurement with the value of analysis through 3D FEM simulation.

  • PDF

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Catenary Measurement System for Real-Time Automated Diahnosis (실시간 자동화 진단을 위한 전차선 검측시스템)

  • Kim, Jeong-Yeon;Park, Jong-Gook;Lee, Byeong-Gon;Hong, Hyun-Pyo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.1020-1026
    • /
    • 2011
  • In this paper, we propose a method that measures the height and stagger of an catenary using the laser profile images. One line laser and area scanner CCD cameras are used. To quickly and accurately extract, from a photographed image, the area of the overhead line on which the line laser is shone, we consider the established fact that the catenary is the lowest among the electric wires. Here we are solving the the distance to the catenary if we know the distance the camera is from the ground and the angle of the catenary in the field of view. The angle will be related to the number of pixels in the image. This pixels per degree is a constant for the camera. Also, because of the different pixel resolution of the camera according to the overhead line position, we compensate the measurement result through camera calibration.

  • PDF

Surface Characteristics of Concrete According to Types of Formworks (거푸집 종류에 따른 콘크리트 표면 특성)

  • Park, Se-Eon;Choi, Jeong-Il;Lee, Bong-Kee;Lee, Bang Yeon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.4
    • /
    • pp.499-505
    • /
    • 2021
  • The purpose of this study is to investigate experimentally the physical/chemical properties of concrete surface according to types of formworks. Plywood formwork and coated plywood formwork were prepared. In addition, plywood formwork with sand paper was prepared to simulate deterioration of concrete or rough surface of concrete. Normal concrete was used in this study. The properties of concrete surface were investigated by visual inspection, scanning electron microscopy and energy-dispersive X-ray spectroscopy techniques, elemental mapping, 2D and 3D surface profile measurement, and zeta potential measurement. Test results showed that concrete in a coated formwork had smooth surface and concrete in the formwork with sand paper had rough surface. It was observed that properties of concrete surface depended on types of formworks. Furthermore, differences in surface roughness were significantly higher than those in chemical compositions and zeta potential.

Heart Rate Variability and Lipid Profile in Patients with Major Depressive Disorder (주요우울장애 환자에서의 심박변이도와 혈중 지질 농도와의 연관성)

  • Ahn, Eun-Jung;Choi, Jin-Sook;Jang, Yong-Lee;Lee, Hae-Woo;Sim, Hyun-Bo
    • Sleep Medicine and Psychophysiology
    • /
    • v.19 no.1
    • /
    • pp.27-34
    • /
    • 2012
  • Objectives: The analysis of heart rate variability (HRV) is a useful non-invasive tool to investigate the autonomic nerve function. Previous studies on the relationship between HRV and depression have been reported controversial results. Similarly, the correlation between the serum lipids and depression is debatable. The purpose of this study is to examine the relationship between heart rate variability, lipid profile and depression. Methods: A total of 42 patients with major depressive disorder (MDD) and 32 age and sex-matched normal subjects who had no previous history of major medical and mental illnesses were recruited for this study. A structured-interview was used to assess the general characteristics and psychiatric illness. HRV measures were assessed by time-domain and frequency-domain analyses. Psychological symptoms were measured using the Hamilton rating scale for anxiety (HAM-A), Hamilton rating scale for depression (HAM-D). In addition, the evaluation for lipid profile was performed by blood test. Results: In serum lipid profile test, MDD group showed higher cholesterol ($197.68{\pm}42.94$ mg/dL vs. $176.85{\pm}34.68$ mg/dL, p=0.044), TG ($139.45{\pm}92.54$ mg/dL vs. $91.4{\pm}65.68$ mg/dL, p=0.018), LDL ($130.03{\pm}33.18$ vs. $106.62{\pm}27.08$, p=0.004) level than normal control group. In HRV time domain analyses, the standard deviation of the NN interval (SDNN) was decreased in MDD group than normal control group, but was not significant ($32.82{\pm}14.33$ ms vs. $40.36{\pm}21.40$ms, p=0.078). ApEn (Approximate Entrophy) was significantly increased in MDD group than normal control group ($1.13{\pm}0.11$ vs. $0.91{\pm}0.18$, p<0.001). ApEn was correlated with LDL level (r=0.277, p=0.028), HAM-D scores (r=0.534, p<0.001) and HAM-A scores (r=0.470, p<0.001). Conclusions: MDD patients showed increased ApEn, one of the HRV measurement. And this ApEn was correlated with LDL, HAM-D and HAM-A scores. In this study, the analysis of ApEn would be a useful test of MDD.

미세금형 가공을 위한 전기화학식각공정의 유한요소 해석 및 실험 결과 비교

  • Ryu, Heon-Yeol;Im, Hyeon-Seung;Jo, Si-Hyeong;Hwang, Byeong-Jun;Lee, Seong-Ho;Park, Jin-Gu
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2012.05a
    • /
    • pp.81.2-81.2
    • /
    • 2012
  • To fabricate a metal mold for injection molding, hot-embossing and imprinting process, mechanical machining, electro discharge machining (EDM), electrochemical machining (ECM), laser process and wet etching ($FeCl_3$ process) have been widely used. However it is hard to get precise structure with these processes. Electrochemical etching has been also employed to fabricate a micro structure in metal mold. A through mask electrochemical micro machining (TMEMM) is one of the electrochemical etching processes which can obtain finely precise structure. In this process, many parameters such as current density, process time, temperature of electrolyte and distance between electrodes should be controlled. Therefore, it is difficult to predict the result because it has low reliability and reproducibility. To improve it, we investigated this process numerically and experimentally. To search the relation between processing parameters and the results, we used finite element simulation and the commercial finite element method (FEM) software ANSYS was used to analyze the electric field. In this study, it was supposed that the anodic dissolution process is predicted depending on the current density which is one of major parameters with finite element method. In experiment, we used stainless steel (SS304) substrate with various sized square and circular array patterns as an anode and copper (Cu) plate as a cathode. A mixture of $H_2SO_4$, $H_3PO_4$ and DIW was used as an electrolyte. After electrochemical etching process, we compared the results of experiment and simulation. As a result, we got the current distribution in the electrolyte and line profile of current density of the patterns from simulation. And etching profile and surface morphologies were characterized by 3D-profiler(${\mu}$-surf, Nanofocus, Germany) and FE-SEM(S-4800, Hitachi, Japan) measurement. From comparison of these data, it was confirmed that current distribution and line profile of the patterns from simulation are similar to surface morphology and etching profile of the sample from the process, respectively. Then we concluded that current density is more concentrated at the edge of pattern and the depth of etched area is proportional to current density.

  • PDF

Optimization of Analytical Condition for Reliable and Accurate Measurement of Carbon Concentration in Carburized Steel by EPMA (EPMA를 이용한 침탄강의 정확하고 신뢰성 있는 탄소농도 측정을 위한 분석조건 최적화)

  • Gi-Hoon Kwon;Hyunjun Park;Byoungho Choi;Young-Kook Lee;Kyoungil Moon
    • Korean Journal of Materials Research
    • /
    • v.33 no.3
    • /
    • pp.106-114
    • /
    • 2023
  • The carbon concentration in the carburized steels was measured by electron probe microanalysis (EPMA) for a range of soluted carbon content in austenite from 0.1 to 1.2 wt%. This study demonstrates the problems in carbon quantitative analysis using the existing calibration curve derived from pure iron (0.008 wt%C) and graphite (99.98 wt%C) as standard specimens. In order to derive an improved calibration curve, carbon homogenization treatment was performed to produce a uniform Kα intensity in selected standard samples (AISI 8620, AISI 4140, AISI 1065, AISI 52100 steel). The trend of detection intensity was identified according to the analysis condition, such as accelerating voltage (10, 15, 30 keV), and beam current (20, 50 nA). The appropriate analysis conditions (15 keV, 20 nA) were derived. When the carbon concentration depth profile of the carburized specimen was measured for a short carburizing time using the improved calibration curve, it proved to be a more reliable and accurate analysis method compared to the conventional analysis method.

High glucose diets shorten lifespan of Caenorhabditis elegans via ectopic apoptosis induction

  • Choi, Shin-Sik
    • Nutrition Research and Practice
    • /
    • v.5 no.3
    • /
    • pp.214-218
    • /
    • 2011
  • Diets based on carbohydrates increase rapidly the blood glucose level due to the fast conversion of carbohydrates to glucose. High glucose diets have been known to induce many lifestyle diseases. Here, we demonstrated that high glucose diet shortened the lifespan of Caenorhabditis elegans through apoptosis induction. Control adult groups without glucose diet lived for 30 days, whereas animals fed 10 mg/L of D-glucose lived only for 20 days. The reduction of lifespan by glucose diet showed a dose-dependent profile in the concentration range of glucose from 1 to 20 mg/L. Aging effect of high glucose diet was examined by measurement of response time for locomotion after stimulating movement of the animals by touching. Glucose diet decreased the locomotion capacity of the animals during mid-adulthood. High glucose diets also induced ectopic apoptosis in the body of C. elegans, which is a potent mechanism that can explain the shortened lifespan and aging. Apoptotic cell corpses stained with SYTO 12 were found in the worms fed 10 mg/L of glucose. Mutation of core apoptotic regulatory genes, CED-3 and CED-4, inhibited the reduction of viability induced by high glucose diet, which indicates that these regulators were required for glucose-induced apoptosis or lifespan shortening. Thus, we conclude that high glucose diets have potential for inducing ectopic apoptosis in the body, resulting in a shortened lifespan accompanied with loss of locomotion capacity.

Development of Indentation Training System for Pulse Diagnosis (맥진 가압 트레이닝 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Woo, Young-Jae;Kim, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.117-122
    • /
    • 2008
  • Although the pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors, there is no proper communication tool between experts and trainees. In this paper, we have developed a indentation training system which consists of a hardware measuring indent pressure on artificial arm quantitatively and a software providing a indentation training program. The hardware for measurement of indent pressure profile includes 3 load cells embedded in the artificial arm, signal amplification part and digitization part, NI-USB 6009 with 200Hz sampling rate. For setting up a relationship table between weights and output voltages, 8 standard weights were used. To evaluate this hardware, 3 oriental medical specialists were involved and their indent pressure profile were recorded three times respectively. From these, it was found that pulse diagnosis process could be divided into 3 periods and the maximum load were $500g{\cdot}f$ approximately while doctors perform a pulse diagnosis. The indentation training program was implemented with LabView and designed to monitor the differences between the pressure profile of a expert and that of a trainee so to offer some visual feedback to the trainee. Also, this program could provide the trends of training performances. With this developed system, the education of pulse diagnosis is expected to be more quantitative and effective.