• Title/Summary/Keyword: 3D profile measurement

Search Result 121, Processing Time 0.027 seconds

Tunnel Reverse Engineering Using Terrestrial LiDAR (지상LiDAR를 이용한 터널의 Reverse Engineering)

  • Cho, Hyung Sig;Sohn, Hong Gyoo;Kim, Jong Suk;Lee, Suk Kun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.931-936
    • /
    • 2008
  • Surveying by using terrestrial LiDAR(Light Detection And Ranging) is more rapid than by using total station which enables tunnel section profile surveying to be done in suitable time and minimize centerline error, occurrence of overcut and undercut. Therefore, utilization of terrestrial LiDAR has increased more and more in section profile survey and measurement field Moreover, studies of terrestrial LiDAR for accurate and efficient utilization is now ongoing vigorously. Average end area formula, which was generally used to calculate overcut and undercut, was compared with existing methods such as total station survey and photogrammetry. However, there are no criteria of spacing distance for calculating overcut and undercut through terrestrial LiDAR surveying which can acquire 3D information of whole tunnel. This research performed reverse engineering to decide optimal spacing distance when surveying tunnel section profile by comparing whole tunnel volume and tunnel volume in difference spacing distance. This result was utilized to produce CAD drawing for the test tunnel site where there is no design drawings. In addition to this, efficiency of LiDAR and accuracy of CAD drawing was compared with targetless total station surveying of tunnel section profile. Finally, error analysis of target coordinate's accuracy and incidence angle was done in order to verify the accuracy of terrestrial LiDAR technology.

A Study on the Accurate 3D Terrain Model Using GPS and EDM (GPS와 EDM을 이용한 정밀 3차원 지형구축)

  • 곽영주;장용구;김상석;강인준
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.11a
    • /
    • pp.99-104
    • /
    • 2004
  • Recently, the old surveying method for acquiring surveying-geo information results had a low economic efficiency and a low dependence of precision because it took much times and high costs. So, we acquired law data by execution of control surveying through Static positioning of DGPS(Ashtech). It is computed plainmetric(X, Y) positioning through postprocessing by Prism S/W. And we computed height(Z) through control surveying by ring-closed leveling surveying. After control surveying execution, we built DEM(Digital Elevation Model) using LDT S/W and accuracy 3D detail surveying by EDM(Electronic Distance Measurement) surveying. The purpose of this study was to yield automated digital mapping and the automated amount of materials using ahead data. The conclusions were as follows; First, we built the automated amount of materials system and got high efficiency about personnel, times and precision. Second, when, people precisely positioned on railroads of a high-speed railroad and used GPS surveying, the result was permitted. Finally, it was possible to draw automated profile and cross-section using the 3D terrain model build with the DEM technique.

  • PDF

The Performance Improvement of a Linear CCD Sensor Using an Automatic Threshold Control Algorithm for Displacement Measurement

  • Shin, Myung-Kwan;Choi, Kyo-Soon;Park, Kyi-Hwan
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1417-1422
    • /
    • 2005
  • Among the sensors mainly used for displacement measurement, there are a linear CCD(Charge Coupled Device) and a PSD(Position Sensitive Detector) as a non-contact type. Their structures are different very much, which means that the signal processing of both sensors should be applied in the different ways. Most of the displacement measurement systems to get the 3-D shape profile of an object using a linear CCD are a computer-based system. It means that all of algorithms and mathematical operations are performed through a computer program to measure the displacement. However, in this paper, the developed system has microprocessor and other digital components that make the system measure the displacement of an object without a computer. The thing different from the previous system is that AVR microprocessor and FPGA(Field Programmable Gate Array) technology, and a comparator is used to play the role of an A/D(Analog to Digital) converter. Furthermore, an ATC(Automatic Threshold Control) algorithm is applied to find the highest pixel data that has the real displacement information. According to the size of the light circle incident on the surface of the CCD, the threshold value to remove the noise and useless data is changed by the operation of AVR microprocessor. The total system consists of FPGA, AVR microprocessor, and the comparator. The developed system has the improvement and shows the better performance than the system not using the ATC algorithm for displacement measurement.

  • PDF

3-Dimensional Numerical Analysis of Deep Depletion Buried Channel MOSFETs and CCDs

  • Kim Man-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.3
    • /
    • pp.396-405
    • /
    • 2006
  • The visual analysis of buried channel (Be) devices such as buried channel MOSFETs and CCDs (Charge Coupled Devices) is investigated to give better understanding and insight for their electrical behaviours using a 3-dimensional (3-D) numerical simulation. This paper clearly demonstrates the capability of the numerical simulation of 'EVEREST' for characterising the analysis of a depletion mode MOSFET and BC CCD, which is a simulation software package of the semiconductor device. The inverse threshold and punch-through voltages obtained from the simulations showed an excellent agreement with those from the measurement involving errors of within approximately 1.8% and 6%, respectively, leading to the channel implanted doping profile of only approximately $4{\sim}5%$ error. For simulation of a buried channel CCD an advanced adaptive discretising technique was used to provide more accurate analysis for the potential barrier height between two channels and depletion depth of a deep depletion CCD, thereby reducing the CPU running time and computer storage requirements. The simulated result for the depletion depth also showed good agreement with the measurement. Thus, the results obtained from this simulation can be employed as the input data of a circuit simulator.

Design of 3-Fingers Type Internal Antenna for GPS/PCS Handsets (GPS/PCS 단말기용 3-Finger형 내장형 안테나 설계)

  • Bang Sang-Won;Jung Byung-Woon;Lee Hak-Yong;Park Myun-Joo;Lee Byungje
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.1 s.92
    • /
    • pp.1-8
    • /
    • 2005
  • This paper proposes a new type of a dual-band internal antenna for GPS/PCS handsets. The antenna has three monopoles in different lengths, and this structure is referred as a 3-fingers type antenna in this paper. The antenna with low-profile structure is designed to use internal space of handset maximally. The fabrication and the measurement are accomplished by attaching the 3-finger type antenna to the inside of a commercial handset. We obtain gain of 1.97 dBi$\~$0.66 dBi in the GPS band, and -0.92 dBi$\~$1.02 dBi in the PCS band and almost omni-directional patterns at all bands.

Design Study of Engine Inlet Duct for Measurement Improvement of the Flow Properties on AIP (AIP면 유동측정 정확도 향상을 위한 가스터빈엔진 입구덕트 설계 연구)

  • Im, Ju Hyun;Kim, Sung Don;Kim, Yong Ryeon
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.3
    • /
    • pp.49-55
    • /
    • 2017
  • In this study, gas turbine engine inlet duct was designed to satisfy uniform flow at aerodynamic interface plane (AIP). Haack-series was selected as nose cone profile and duct outer radius($r_o$) was designed to satisfy to match with area change rate between the nose cone and outer duct wall by the 1-D sizing. The design object of the inlet duct wall profile which has the gradual area change rate was uniform Mach number in the core flow region and minimum boundary later thickness at the both inner nose wall and outer duct wall. The flow characteristics inside the inlet duct was evaluated using CFD. The static pressure distribution at the AIP showed uniform pattern within 0.16%. Based on Mach number profile, the boundary layer thickness was 2% of channel height. Kiel temperature rake location was decided less than 100 mm in front of nose cone where the Mach number is less than 0.1 in order to maximize the temperature probe recovery rate.

Assessment of Yield Characteristics of Gas Pipeline Materials by Observing Surface-Local Deformation (미소 표면변형 관찰을 통한 가스배관 부재의 항복특성 평가)

  • Lee, Yun-Hee;Baek, Un-Bong;Cheong, In-Hyeon;Nahm, Seung-Hoon;Lee, Sang-Houck
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.92-98
    • /
    • 2008
  • A combination of the instrumented indentation and 3D morphology measurement has been tried in order to perform a real-time property measurement of degraded materials in gas pipelines; three-dimensional indent morphologies were recorded using a reflective laser scanner after a series of insturmented indentations on three metallic specimens. Dimensions of the permanent deformation zone and contact boundary were analyzed from the cross-sectional profile over an remnant indent and used for estimating yield strength and hardness, respectively. Estimated yield strength was comparable with that from uniaxial tensile test and actual hardness implying material pile-up effects was lower than the calculated value from indentation curve by $20{\sim}30%$. It means that this 3D image analysis can explain the material pile-up effects on the contact properties. Additionally, a combined system of indentation and laser sensor was newly designed by modifying a shape of the indentation loading fixture.

  • PDF

Effects of dietary onion (Allium cepa) extract supplementation on performance, apparent total tract retention of nutrients, blood profile and meat quality of broiler chicks

  • Aditya, Siska;Ahammed, Musabbir;Jang, Seong Hun;Ohh, Sang Jip
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.2
    • /
    • pp.229-235
    • /
    • 2017
  • Objective: This study was conducted to investigate the effect of dietary onion (Allium cepa) extract (OE) supplementation on growth performance, apparent total tract retention (ATTR), blood profile, carcass characteristics and meat quality in broilers. Methods: Four hundred male broiler chicks (Ross 308, 3-d old) were randomly allocated to four dietary treatments for 28 d feeding trial. Each treatment has five replications with 20 birds each. Four dietary treatments were designated according to the OE supplementation levels (0 as control, 5, 7.5, and 10 g of OE per kg of basal diet respectively). On d 28, a total of 20 birds from each treatment were subjected for ATTR, serum biochemical assay, carcass characteristic and organ weight measurement. Results: Overall weight gain of OE 7.5 g/kg group was higher (p = 0.04) than control group. The ATTRs of dietary energy (p<0.01) and ether extract (p = 0.04) linearly increased with increasing levels of dietary OE. However, no difference in ATTR of dry matter and crude protein was evident. Furthermore, serum IgG concentration increased linearly (p<0.01) and quadratically (p = 0.03) with increasing OE supplementation. No differences in carcass dressing weight and amount of abdominal fat by treatments were observed. Also, the weight of organ including immune organ was not different among the treatments. The TBARS values of 10 d stored breast meat decreased linearly (p<0.01) and quadratically (p<0.01) with increasing dietary OE levels. The meat color was also affected, with lower (p<0.01) redness score in meats from OE supplemented groups. This study showed that dietary OE improved broiler weight gain presumably by increasing feed intake and ATTR of both energy and ether extract. The dietary OE increased serum IgG level and meat anti-oxidation capacity. Conclusion: This study implies that the recommended level of dietary OE supplementation could be beneficial for improving broiler performance and meat quality.

Three-dimensional morphometric analysis of mandibule in coronal plane after bimaxillary rotational surgery

  • Lee, Sung-Tak;Choi, Na-Rae;Song, Jae-Min;Shin, Sang-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.38
    • /
    • pp.49.1-49.9
    • /
    • 2016
  • Background: The aim of this report is to present a new reference for aesthetic mandible surgery using three-dimensional cone-beam computed tomography-based treatment planning for orthognathic surgery which can be implemented in surgical planning and perioperative procedure. Methods: To make an objective standard for evaluating aesthetic mandibular outline, we make an aesthetic scoring criteria with consideration of asymmetry, broad mandibular border line, and prominent mandibular angle. Two maxillofacial surgeons and two orthodontists rated their aesthetical evaluation from 1 to 5. Experimental group consisting of 47 female and 38 male patients who had rotational orthognathic two-jaw surgery from 2010 to 2011 were chosen according to aesthetic scoring done by two maxillofacial surgeons and two orthodontists. A high aesthetic score (${\geq}16$) means the facial contour is symmetric, with no broad and narrow aesthetic mandible frontal profiles. Control A group consisted of ten female and ten male patients who had no orthognathic surgery experience and low aesthetic score (${\geq}10$). Control B group consisted of ten female and ten male patients who had no orthognathic surgery experience and had anaesthetic mandibular frontal profile and a high aesthetic score (${\geq}16$). The three-dimensional image of the patient was taken from dental cone-beam CT (DCT) scanning (experimental group and control A group: 6 months DCT after surgery, control B group: 1st visit DCT). Each DCT was reformatted to reorient the 3D image using 3D analyzing program (OnDemand3D, cybermed Inc, CA, USA). After selection of 12 landmarks and the construction of reoriented horizontal, vertical, and coronal reference lines, 15 measurements were taken in 3D analysis of frontal mandibular morphology. Afterwards, horizontal and vertical linear measurements and angular measurements, linear ratio were obtained. Results: Mean $Go^{\prime}_{Rt}-Me^{\prime}-Go^{\prime}_{Lt}$ angular measurement was $100.74{\pm}2.14$ in female patients and $105.37{\pm}3.62$ in male patients. These showed significant difference with control A group in both genders. Ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}-Me^{\prime}$ length to some linear measurements (ratio of $Me^{\prime}-Cd^{\prime}_{Rt}Cd^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Me^{\prime}-Go^{\prime}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$, ratio of $Go^{\prime}_{Rt}-Go^{\prime}_{Lt}$ to $Me^{\prime}-Go^{\prime}_{Rt}Go^{\prime}_{Lt}$) showed significant difference with control A group in both genders. Conclusion: This study was intended to find some standard measurement of mandible frontal view in 3D analysis of aesthetic patient. So, these potential measurement value may be helpful for orthognathic treatment planning to have more aesthetic and perspective outcomes.

Feasibility of Fabricating Variable Density Phantoms Using 3D Printing for Quality Assurance (QA) in Radiotherapy

  • Oh, Se An;Kim, Min Jeong;Kang, Ji Su;Hwang, Hyeon Seok;Kim, Young Jin;Kim, Seong Hoon;Park, Jae Won;Yea, Ji Woon;Kim, Sung Kyu
    • Progress in Medical Physics
    • /
    • v.28 no.3
    • /
    • pp.106-110
    • /
    • 2017
  • The variable density phantom fabricated with varying the infill values of 3D printer to provide more accurate dose verification of radiation treatments. A total of 20 samples of rectangular shape were fabricated by using the $Finebot^{TM}$ (AnyWorks; Korea) Z420 model ($width{\times}length{\times}height=50mm{\times}50mm{\times}10mm$) varying the infill value from 5% to 100%. The samples were scanned with 1-mm thickness using a Philips Big Bore Brilliance CT Scanner (Philips Medical, Eindhoven, Netherlands). The average Hounsfield Unit (HU) measured by the region of interest (ROI) on the transversal CT images. The average HU and the infill values of the 3D printer measured through the 2D area profile measurement method exhibited a strong linear relationship (adjusted R-square=0.99563) in which the average HU changed from -926.8 to 36.7, while the infill values varied from 5% to 100%. This study showed the feasibility fabricating variable density phantoms using the 3D printer with FDM (Fused Deposition Modeling)-type and PLA (Poly Lactic Acid) materials.