• 제목/요약/키워드: 3D probe

검색결과 408건 처리시간 0.029초

A Triple-Probe Channel NO2S2-Macrocycle: Synthesis, Sensing Characteristics and Crystal Structure of Mercury(II) Nitrate Complex

  • Lee, Ji-Eun;Choi, Kyu-Seong;Seo, Moo-Lyong;Lee, Shim-Sung
    • Bulletin of the Korean Chemical Society
    • /
    • 제31권7호
    • /
    • pp.2031-2035
    • /
    • 2010
  • A triple-probe channel type chemosensor based on an $NO_2S_2$-macrocycle functionalized with phenyltricyanovinyl group was synthesized and its sensing characteristics were examined. The pink-red solution of L changed selectively to pale yellow upon addition of $Hg^{2+}$. The selective fluorometric response of L to all the tested metal ions was studied. The results showed that a large enhancement of the fluorescence of L was observed only in the case of $Hg^{2+}$. In addition, L showed large anodic shift (~ 0.3 V) for the addition of excess $Hg^{2+}$. Through above three observed results by the different techniques, we confirmed that the proposed chemosensor acts as the multiple-probe channel sensing material. The crystal structure of mercury(II) nitrate complexs of L which shows a 1-D polymer network with a formula $[Hg_2(L)_2(NO_3)_2({\mu}-NO_3)_2]_n$ was also reported.

자기 베어링으로 지지 되는 직선운동 테이블의 초정밀 위치제어에 관한 연구 (Micropositioning of a Linear Motion Table with Magnetic Bearing Suspension)

  • 김의석;안형준;장인배;한동철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1995년도 추계학술대회 논문집
    • /
    • pp.466-469
    • /
    • 1995
  • This paper presents a design and performance of the 6 D.O.F linear motion table with a magnetic bearing suspension. The linear positioning of the table with a 150mm stroke is driven by a brushless DC Linear motor and the other attitudes of the stage are controlled by the analog PD controller with magnetic bearing actuators. Each magnetic bearing unit which consists of 3 electromagnets, 3 capacitance probes and 3 backup bearings affords controlled forces by detecting the air gap between the probes and guideways. An integral type capacitance probe amplifier is equipped on the upper plate of the table so that the probe line to the probe amplifier can be shorter therefore the problems due to the stray capacitance and noise can be reduced. Form the pitch-yaw errormeasured by the autocollimator, the vertical and horizont straightness errors of the table are derived that they are maintained below 1.mu. m over 100mm stroke. The positioning accuracy of the linear motion is maintained below 2 .mu. m and the repeatability error is below 1 .mu. m

  • PDF

전자기 수치 해석을 이용한 Combo 표준 보정 시험편의 MRPC Probe 와전류 신호 모사 및 평가 (Simulation and Evaluation of ECT Signals From MRPC Probe in Combo Calibration Standard Tube Using Electromagnetic Numerical Analysis)

  • 유주영;송성진;정희준;공영배
    • 비파괴검사학회지
    • /
    • 제26권2호
    • /
    • pp.90-98
    • /
    • 2006
  • 원전 증기 발생기 세관의 MRPC probe 신호를 검사하고 평가하기 위해서는 일반적으로 Combo 표준 보정 시험편 신호가 신호 보정을 위해 사용된다 이렇듯 Combo 표준 보정 시험편 신호는 신호 평가에 중요한 영향을 미치지만, probe 상태나 관 주위의 여러 요소에 의해 쉽게 영향을 받기 때문에 결함 평가 요소인 신호의 크기 값과 위상각을 왜곡시킬 수 있다. 따라서 본 연구는 이런 문제점을 극복하기 위해 Combo 표준 보정 시험편의 실제 신호를 모사 신호로 대체하는 가능성을 알아보기 위해 실험을 해 보았다 이를 위해 MRPC probe와 Combo 표준 보정 시험편의 특성을 조사하였으며 계산 수행을 위해 체적 적분 방법으로 계산되는 상용 전자기 해석 프로그램인 VIC-3D를 사용하였고 모사 신호를 생성한 후 실험 신호와 비교를 통해 신호의 정확성을 확인하였다. 마지막으로, 모사 신호를 이용한 결함 평가를 위하여 실제 결함과 가공 결함에 대해 위상각과 크기 값의 항목으로 평가하여 실제 결함 평가자에 의한 결과와 비교하였다.

수직형 MEMS 프로브 팁의 신뢰성 설계 및 전기적 특성평가 (Reliable design and electrical characteristics of vertical MEMS probe tip)

  • 이승훈;추성일;김진혁;한동철;문성욱
    • 한국신뢰성학회지:신뢰성응용연구
    • /
    • 제7권1호
    • /
    • pp.23-29
    • /
    • 2007
  • Probe card is a test component which is to classify the known good die with electrical contact before the packaging in the ATE (automatic testing equipment). Conventional probe tip was mostly needle type, it has been difficult to meet with conventional type, because of decreasing chip size, pad to pad pitch and pads size increasingly. For that reason, probe cards using MEMS (micro electro mechanical system) technology have been developed for various semiconductor chips. In this paper, Area Array type MEMS Probe tip was designed,, fabricated, and characterized its mechanical and electrical properties. The authors found that good electrical characteristics under $1{\Omega}$ were acquired with gold (Au) and aluminium (Al) pad contact test over 0.5gf and 4gf respectively. And, contact resistance variation under $0.1{\Omega}$ were achieved with 100,000 times of repetition test. And, insertion loss (IS) for high frequency operation was ascertained over 300MHz at -3dB loss.

  • PDF

증기발생기 전열관의 비파괴 탐상용 차등형 와전류 탐촉자 개발 (Development of Differential Type Eddy Current Probe for NDT Evaluation of the Steam Generator Tube)

  • 정선영;손대락;유권상;박덕근
    • 한국자기학회지
    • /
    • 제15권5호
    • /
    • pp.292-297
    • /
    • 2005
  • 원자력 발전소 증기발생기의 전열관은 전열면으로서의 역할과 방사능 차단벽의 역할로서 중요하며, 증기발생기 튜브의 폭발은 원자력 발전소 사고에 관계된다. 증기발생기 전열관 재료로는 Incone1600이 사용되고 있으며, 이 재료가 금속이면서 비자성이기 때문에 와전류 탐상법으로 전열관의 결함을 탐지하고 있다. 본 연구에서는 탐상 감도를 향상시키기 위하여 차등형 와전류 탐촉자를 개발하였으며, 개발된 차등형 와전류 탐촉자의 성능검사를 위해 Inconel600과 자기적 성질이 비슷하고 구하기 쉬운 SUS304로 가로 100mm, 세로 100mm, 그리고 두께 10mm인 평판에 선형결함과 원형결함을 가공하여 기준시편으로 제작하였다. 제작된 차등형 와전류 탐촉자를 사용하여, 자화주파수 50kHz, lift-off 0.4mm에서 직경이 0.25mm이고, 깊이가 0.2mm 크기의 결함까지 측정이 가능하였다.

Plasma Uniformity Analysis of Inductively Coupled Plasma Assisted Magnetron Sputtering by a 2D Voltage Probe Array

  • Joo, Junghoon
    • Applied Science and Convergence Technology
    • /
    • 제23권4호
    • /
    • pp.161-168
    • /
    • 2014
  • A real-time monitoring of immersed antenna type inductively coupled plasma (ICP) was done with a homemade 2 dimensional voltage probe array to check the uniformity of the plasma. Measured voltage values with a high impedance voltmeter are close to the floating potential of the plasma. As the substrate carrier was moving into a magnetron sputtering plasma diffusive from a $125mm{\times}625mm$ size cathode, measured results showed reliably separation of plasma into the upper and lower empty space over the carrier. Infra red thermal imaging camera was used to observe the cross corner effect in situ without eroding a target to the end of the usage. 3 dimensional particle trace model was used to analyze the magnetron discharge's behavior.

개방형 원심회전차의 내부유동장에 관한 실험적 연구(1)-무충돌 유입조건에서- (Experimental Study on Flows within an Unshrouded Centrifugal Impeller Passage(I)-At the Shockless Condition-)

  • 김성원;조강래
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2261-2270
    • /
    • 1995
  • Flow patterns were measured in an unshrouded centrifugal impeller. The flow rate in measurements was fixed at the value corresponding to a nearly zero incidence at the blade inlet. By using a single slanted hot-wire probe and a Kiel probe mounted on the impeller hub disk, the 3-D relative velocities and the rotary stagnation pressures were measured in seven circumferential planes from the inlet to the outlet of the impeller rotating at 700rpm, which diameter is 0.39 meter, and the static pressures and the slip factor at the impeller outlet were calculated from the measured values. From the measured data, the primary/secondary flows, the leakage flows, the wake-jet flows, static pressure distribution on blade surfaces and the wake production mechanism in the impeller passage were investigated.

실내 마이크로파 배전용 완전 정합형 전력 분배 스위치의 설계 (Matching-type Power Dividing Switch for Low Reflection in Indoor Microwave Power Distribution)

  • 최영규
    • 전기학회논문지
    • /
    • 제62권6호
    • /
    • pp.792-797
    • /
    • 2013
  • In a indoor microwave power distribution system, matching-type power dividing switch is proposed and designed with a various power dividing ratio. A matching coaxial cable probe is used behind the output probe for the reflecting power absorption. Reflecting characteristics of the matching coaxial cable probe are calculated by analyzing the S-parameter of this structure. Newly proposed matching-type switch shows a very low return loss less than -30dB at the operating frequency of 2.45GHz with a dividing power ratio of 50.2%. The simulated results by use of 3-stage power divider shows a good agreement with the theoretical estimation for the various combination of the different switching ratio.

순간 열플럭스 측정용 프루브 개발 및 유한요소법에 의한 피스톤 열응력 계산 (The Development of Instantaneous Heat Flux Measurement Probe and Calculation of Thermal Stress of Piston by Finite Element Method)

  • 이재순;우종헌;이응래;정인곤;이현구
    • 한국자동차공학회논문집
    • /
    • 제6권6호
    • /
    • pp.267-275
    • /
    • 1998
  • In this study, the instantaneous heat flux measurement probe and the linkage system for the measurement of the instantaneous temperature and heat flux of the DI mono cylinder diesel engine were developed, and these were proved to have a good reliability and sensibility. A 3-D FEM model which consist of full piston to accommodate the eccentric bowl in the piston head, was applied for the analysis of the thermal stress and the temperature distribution. The mean heat flux on the piston head was used as boundary condition for the analysis of piston. The analysis showed that thermal stress concentrate on the bowl and inner surface of pin hall.

  • PDF

결함인자를 고려한 원전 SG세관에서의 RPC 프로브의 신호 해석 (Analysis of RPC Probe Signal for S/G Tube in Nuclear Power Plant Considering Defect Factor)

  • 김지호;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.53-55
    • /
    • 2005
  • The signals of the eddy current testing(ECT) for the examination of the steam generator(SG) tubes in the nuclear power plant(NPP) determine the existence, size, and kind of defects using the variation of impedance signals when a testing coil, driven by alternating current, passes through the SG tube contains defects. The aim of this paper is building a database of the RPC probe signals on the basis of the sizes variation of defects and frequency variation of probe. In this paper 3-D numerical analysis of the ECT signals using the finite element method is performed. Through this study, it is shown variation of magnitude and phase of impedance according to variation of defect size and frequency. From the result of this paper, we can obtain the information which is useful in defect discrimination of SG tube in nuclear power plant.

  • PDF