• Title/Summary/Keyword: 3D probe

Search Result 407, Processing Time 0.03 seconds

Partial Discharge Measurement by a Capacitive Voltage Probe in a Gas Insulated Switch (가스절연개폐기에서 용량성 전압프로브를 이용한 부분방전 측정)

  • Choi, Su-Yeon;Park, Chan-Yong;Park, Dae-Won;Kim, Il-Kwon;Kil, Gyung-Suk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.476-477
    • /
    • 2007
  • This paper described the partial discharge (PD) measurement techniques for diagnosing gas-insulated switches in overhead power distribution system. A capacitive voltage probe to detect PD pulse was designed and fixed on the surface of a bushing. We also designed a coupling network to attenuate AC voltage by 270 dB, and a low-noise amplifier having the gain of 40 dB and 500 kHz~20 MHz 3 dB. From the calibration, it was calculated that the sensitivity of the measurement system was 0.94mV/pC. In the application experiment, we could measure a PD pulse of 45 pC.

  • PDF

BCI Probe Emulator Using a Microstrip Coupler (마이크로스트립 커플러 구조를 이용한 BCI 프로브 Emulator)

  • Jung, Wonjoo;Kim, SoYoung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.11
    • /
    • pp.1164-1171
    • /
    • 2014
  • Bulk Current Injection(BCI) test is a method of injecting current into Integrated Circuit(IC) using a current injection probe to qualify the standards of Electromagnetic Compatibility(EMC). This paper, we propose a microstrip coupler structure that can replace the BCI current injection probe that is used to inject a RF noise in standard IEC 62132-part 3 documented by International Electrotechnical Commission. Conventional high cost BCI probe has mostly been used in testing automotive ICs that use high supply voltage. We propose a compact microstrip coupler which is suitable for immunity testing of low power ICs. We tested its validity to replace the BCI injection probe from 100 MHz to 1,000 MHz. We compared the power[dBm] that is needed to generate the same level of noise between current injection probe and microstrip coupler by sweeping the frequency. Results show that microstrip coupler can inject the same level of noise into ICs for immunity test with less power.

A Travel Time Estimation Algorithm using Transit GPS Probe Data (Transit GPS Data를 이용한 링크통행시간 추정 알고리즘 개발)

  • Choi, Keechoo;Hong, Won-Pyo;Choi, Yoon-Hyuk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.5D
    • /
    • pp.739-746
    • /
    • 2006
  • The bus probe-based link travel times were more readily available due to bus' fixed route schedule and it was different from that of taxi-based one in its value for the same link. At the same time, the bus-based one showed less accurate information than the taxi-based link travel time, in terms of reliability expressed by 1-RMSE(%) measure. The purpose of this thesis is to develop a heuristic algorithm for mixing both sources-based link travel times. The algorithm used both real-time and historical profile travel times. Real-time source used 4 consecutive periods' average and historical source used average value of link travel time for various congestion levels. The algorithm was evaluated for Seoul urban arterial network 3 corridors and 20 links. The results based on the developed algorithm were superior than the mere fusion based link travel times and the reliability amounted up to 71.45%. Some limitation and future research agenda have also been discussed.

Wide Band Microstrip line-to-Rectangular Waveguide Transition Using a Radial Probe for Millimeter-wave Applications (밀리미터파 응용을 위해 Radial 프로브 마이크로 스트립-웨이브 가이드 광대역 천이기)

  • Lee, Young Chul
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.43-47
    • /
    • 2015
  • In this work, a broadband microstrip (MSL) - to - waveguide (WR12) transition has been presented for millimeter-wave module applications. For improvement of a bandwidth, the radial MSL electrical-probe is designed on the low-loss organic dielectric substrate. The designed and tested characteristics of the proposed transition are characterized in terms of an insertion and return loss. Considering the loss contribution of the cable adapter and waveguide transition for the measurement, the proposed transition loss can be analyzed as -1.88 and -2.01 dB per a transition at 70 and 80 GHz, respectively. The bandwidth of the proposed transition for reflection at -10 dB is 26 GHz at all test frequencies from 67 to 95 GHz. Compared to the state-of-the-art results, improvement of 8.3 % is achieved for the operation bandwidth.

Genomic DNA probe and purification of Theileria sergenti merozoites in Korean cattle (한우에 감염된 Theileria sergenti merozoite의 순수분리와 genomic DNA probe에 관한 연구)

  • Chae, Joon-seok;Lee, Joo-mook;Kwon, Oh-deog;Chae, Keon-sang
    • Korean Journal of Veterinary Research
    • /
    • v.34 no.2
    • /
    • pp.387-394
    • /
    • 1994
  • To make the genomic DNA probe of Theileria sergenti, the merozoites were purified from bovine erythrocytes. The infected erythrocytes were lysed by Aeromonas hydrophila(Ah-1) hemolysin, and the parasites were isolated by ultracentrifugation on a Percoll discontinuous density gradient. For construction of a T sergenti genomic DNA library, T sergenti DNA was digested with Pstl and the fragments were ligated into the PstI site of pUC19 before transformation of Escherichia coli JM83. Out of thousands of transformants obtained by transformation of E coli JM83 with the genomic library, three plasmids were chosen. The sizes of the inserted DNAs were 2.9kb(2.4kb and 0.5kb) in pKTS1, 4.3kb in pKTS2 and 1.5kb in pKTS3, respectively. The DNA fragments used as probe KTS1(2.4kb), KTS2(4.3kb) and KTS3(1.5kb) were labeled digoxigenin-11-dUTP for the Southern hybridization. In Southern hybridization, all of the probes(KTS1, KTS2 and KTS3) reacted specifically to T sergenti DNA, but not to bovine leucocyte DNA. In order to find out the sensitivities of the digoxigenin-11-dUTP-labeled KTS1 and KTS3 as the probes, purified merozoite DNA and bovine DNA (control) were checked by dot blot hybridization with the probes. Both of the probes, KTS1 and KTS3, detected as minimum amount of 975pg of the T sergenti DNA, but not bovine DNA even to 500ng.

  • PDF

THREE DIMENSIONAL ATOM PROBE STUDY OF NI-BASE ALLOY/LOW ALLOY STEEL DISSIMILAR METAL WELD INTERFACES

  • Choi, Kyoung-Joon;Shin, Sang-Hun;Kim, Jong-Jin;Jung, Ju-Ang;Kim, Ji-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.44 no.6
    • /
    • pp.673-682
    • /
    • 2012
  • Three dimensional atom probe tomography (3D APT) is applied to characterize the dissimilar metal joint which was welded between the Ni-based alloy, Alloy 690 and the low alloy steel, A533 Gr. B, with Alloy 152 filler metal. While there is some difficulty in preparing the specimen for the analysis, the 3D APT has a truly quantitative analytical capability to characterize nanometer scale particles in metallic materials, thus its application to the microstructural analysis in multi-component metallic materials provides critical information on the mechanism of nanoscale microstructural evolution. In this study, the procedure for 3D APT specimen preparation was established, and those for dissimilar metal weld interface were prepared near the fusion boundary by a focused ion beam. The result of the analysis in this study showed the precipitation of chromium carbides near the fusion boundary between A533 Gr. B and Alloy 152.

2-D & 3-D Observations on the microstructures of Super Bainitie TRIP Steels using Total Analysis System (TAS (Total Analysis System)를 이용한 SB-TRIP강에서의 2-D & 3-D 미세구조 분석 연구)

  • Seol, J.B.;Lim, Y.R.;Park, C.G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.209-212
    • /
    • 2009
  • It has been widely reported that carbide-free bainitic steels or super-bainite WP (SB-TRIP) steels for the automotive industry are a new family of steels offering a unique combination of high strength and ductility. Hence, it is important to exactly evaluate the volume fraction of RA and to identify the 3-D morphology of constituent phases, because it plays a crucial role in mechanical properties. Recently, as electron back-scattered diffraction (EBSD) equipped with focused ion beam (FIB) has been developed, 3-D EBSD technique for materials science are used to these steels. Moreover, newly developed atom probe tomography (APT) technique can provide the exact distribution and chemical concentration of alloying elements in a sub-nm scale. The APT analysis results indicate exactly the distribution and composition of alloying elements in the austenite and bainite phases of SB-TRIP steels with the atomic-scale resolution. And thus, no partitioning of aluminum and manganese atoms was showed between the austenite containing $7.73{\pm}0.39$ at% C and the bainitic ferrite associated with $0.22{\pm}0.06$ at% C in the SB-TRIP steel.

  • PDF

2-D & 3-D Observations on the Microstructure of Super Bainite TRIP Steels using Total Analysis System (TAS(Total Analysis System)을 이용한 SB-TRIP강에서의 2-D & 3-D 미세구조 분석 연구)

  • Seol, J.B.;Lee, B.H.;Park, C.G.
    • Transactions of Materials Processing
    • /
    • v.19 no.1
    • /
    • pp.44-49
    • /
    • 2010
  • It has been widely reported that carbide-free bainitic steels or super-bainite TRIP (SB-TRIP) steels for the automotive industry are a new family of steels offering a unique combination of high strength and ductility. Hence, it is important to exactly evaluate the volume fraction of RA and to identify the 3-D morphology of constituent phases, because it plays a crucial role in mechanical properties. Recently, as electron back-scattered diffraction (EBSD) equipped with focused ion beam (FIB) has been developed, 3-D EBSD technique for materials science are used to these steels. Moreover, newly developed atom probe tomography (APT) technique can provide the exact distribution and chemical concentration of alloying elements in a sub-nm scale. The APT analysis results indicate exactly the distribution and composition of alloying elements in the austenite and bainite phases of SB-TRIP steels with the atomic-scale resolution. And thus, no partitioning of aluminum and manganese atoms was showed between the austenite containing $7.73{\pm}0.39$ at% C and the bainitic ferrite associated with $0.22{\pm}0.06$ at% C in SB-TRIP steel.

Optical and Mechanical Characteristics of NF System and NF Gap Control (근접장 광학계의 광학적 및 기계적 특성 분석과 근접장 간격제어)

  • Oh, Hyeong-Ryeol;Lee, Jun-Hee;Gweon, Dae-Gab;Kim, Soo-Kyung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1528-1532
    • /
    • 2000
  • The conventional optics and near field optics are compared numerically in the view points of the spot size and propagation characteristics. The decaying characteristics of near field light require the optics to access the object within several tens of nanometers. Therefore the gap control is one of the main issues in the near field optics area. In this paper the gap control is done by using the shear force of the NF(Near Field) probe and the characteristics are examined. The probe is modeled as a 2'nd order mass-spring-damper system driven by a harmonic force. The primary cause of the decrease in vibration amplitude is due to the damping force - shear force - between the surface and the probe. Using the model, damping constant and resonance frequency of the probe is calculated as a function of probe-sample distance. Detecting the amplitude and phase shift of the NF probe attached to the high Q-factor piezoelectric tuning fork, we can control the position of the NF probe about 0 to 50nm above the sample. The feedback signal to regulate the probe-sample distance can be used independently for surface topography imaging. 3-D view of the shear force image of a testing sample with the period of $1{\mu}m$ will be shown.

  • PDF

Characterization of Two-Dimensional Transition Metal Dichalcogenides in the Scanning Electron Microscope Using Energy Dispersive X-ray Spectrometry, Electron Backscatter Diffraction, and Atomic Force Microscopy

  • Lang, Christian;Hiscock, Matthew;Larsen, Kim;Moffat, Jonathan;Sundaram, Ravi
    • Applied Microscopy
    • /
    • v.45 no.3
    • /
    • pp.131-134
    • /
    • 2015
  • Here we show how by processing energy dispersive X-ray spectrometry (EDS) data obtained using highly sensitive, new generation EDS detectors in the AZtec LayerProbe software we can obtain data of sufficiently high quality to non-destructively measure the number of layers in two-dimensional (2D) $MoS_2$ and $MoS_2/WSe_2$ and thereby enable the characterization of working devices based on 2D materials. We compare the thickness measurements with EDS to results from atomic force microscopy measurements. We also show how we can use electron backscatter diffraction (EBSD) to address fabrication challenges of 2D materials. Results from EBSD analysis of individual flakes of exfoliated $MoS_2$ obtained using the Nordlys Nano detector are shown to aid a better understanding of the exfoliation process which is still widely used to produce 2D materials for research purposes.