• 제목/요약/키워드: 3D motion analysis system

검색결과 296건 처리시간 0.03초

하이힐 보행이 비만여성의 슬관절에 미치는 영향 (Influence of Walking With High-Heeled Shoes on the Knee Joint of Obese Women)

  • 장윤희;이완희
    • 한국전문물리치료학회지
    • /
    • 제14권3호
    • /
    • pp.23-31
    • /
    • 2007
  • The purpose of this study was to determine the influence of high-heeled shoes on walking of obese women as it was already proven an extrinsic factor of knee osteoarthritis in women with normal weight. In this study the aimed therefore in particular was to utilize high-heeled shoes in proving it's causal influence on knee osteoarthritis by measuring the angle and torque of the knee joint. Fifteen obese women (BMI>25 $kg/m^2$) were measured in their twenties. Each angle and torque of their knee joints during walking on 6.5 cm high-heeled shoes and with a bare feet, were compared with each other and analyzed with a 3D motion analysis system. There was no significant difference in walking speed, cadence and stride length between the two conditions. However, there was a significant increase in a double limb support time and the stance phase when walking on high-heeled shoes as when walking with bare feet. The peak knee flexion angle and peak knee varus torque was higher when walking on high-heeled shoes than with bare feet. On the contrary, the peak knee flexion angle in the swing phase was not statistically different. The prolongation of peak knee varus torque was also proven. There was a significant increase in peak knee varus torque in the initial and last stance phases during walking on high-heeled shoes as compared to walking on bare feet. Through the above results, it was proven that when obese women walked on high-heeled shoes, rather than with bare feet, peak knee flexor and varus torque increased along with the changes of the in knee joint angle. Therefore, the influence of high-heeled shoes might be a significant intrinsic factor in knee osteoarthritis of obese women.

  • PDF

Spring rod를 사용한 척추경 나사못과 동반 시술된 Flexible cage의 생체역학적 효과 (Biomechanical Efficacy of a Combined Flexible Cage with Pedicle Screws with Spring rods: A Finite Element Analysis)

  • 김영현;박은영;김원현;황성필;박경우;이성재
    • 대한의용생체공학회:의공학회지
    • /
    • 제38권1호
    • /
    • pp.9-15
    • /
    • 2017
  • Recently, flexible cages have been introduced in an attempt to absorb and reduce the abnormal load transfer along the anterior parts of the spine. They are designed to be used with the pedicle screw systems to allow some mobility at the index level while containing ROM at the adjacent level. In this study, a finite element (FE) study was performed to assess biomechanical efficacies of the flexible cage when combined with pedicle screws with flexible rods. The post-operated models were constructed by modifying the L4-5 of a previously-validated 3-D FE model of the intact lumbar spine (L2-S1): (1) Type 1, flexible cage only; (2) Type 2, pedicle screws with flexible rods; (3) Type 3, interbody fusion cage plus pedicle screws with rigid rods; (4) Type 4, interbody fusion cage plus Type 2; (5) Type 5, Type 1 plus Type 2. Flexion/extension of 10 Nm with a compressive follower load of 400N was applied. As compared to the Type 3 (62~65%) and Type 4 (59~62%), Type 5 (53~55%) was able to limit the motion at the operated level effectively, despite moderate reduction at the adjacent level. It was also able to shift the load back to the anterior portions of the spine thus relieving excessively high posterior load transfer and to reduce stress on the endplate by absorbing the load with its flexible shape design features. The likelihood of component failure of flexble cage remained less than 30% regardless of loading conditions when combined with pedicle screws with flexible rods. Our study demonstrated that flexible cages when combined with posterior dynamic system may help reduce subsidence of cage and degeneration process at the adjacent levels while effectively providing stability at the operated level.

보행속도변화와 동시 인지과제가 보행 가변성에 미치는 영향 (Effects of Walking Speeds and Cognitive Task on Gait Variability)

  • 최진승;강동원;탁계래
    • 한국운동역학회지
    • /
    • 제18권2호
    • /
    • pp.49-58
    • /
    • 2008
  • 본 연구의 목적은 트레드밀 보행 시, gait dynamics 측면에서 보행의 속도 변화와 인지과제 수행 시 보행 변인의 가변성(variability)을 알아보고자 하는 것이다. 실험은 인지과제의 동시수행 유/무에 따른 5가지 속도(선호속도의 80%, 90%, 100%, 110% and 120%)에 의한 보행 실험으로 구성되었다. 인지과제의 종류는 학습기능이 없는 인지과제(2-back task)를 수행하였다. 인지과제는 피험자의 트레드밀 보행 시, 3m 앞에 놓여진 스크린에 주어지고 무선마우스를 통해 응답하는 형태로 구성되었다. 실험의 모든 과정은 3차원 동작분석기를 통해 동작데이터를 획득하였다. 이를 통해, 5가지 보행 시간 변인과 3가지 공간 변인을 추출하였다. gait dynamics 측면의 분석을 위해, 가변성의 크기를 살펴볼 수 있는 방법인 분산계수(coefficient of variance)와 변동량의 구조적 자기 유사성을 추론할 수 있는 detrended fluctuation analysis (DFA)를 사용하였다. 그 결과 보행 속도 변화에 따라 보행 변인의 평균값과 분산계수에서 통계적 유의한 차이가 발생하였고, 인지과제의 수행 유/무에 따라서는 DFA에서 통계적인 차이가 발생하였다. 이는 인지과제의 수행에 의해 보행의 발생과 조절 능력에 영향을 끼쳤다고 추론할 수 있다. 본 연구 결과를 명백히 하기 위해 더 많은 수의 피험자 실험과 추가 실험이 필요할 것이다.

뇌 자기공명영상에서 Quiet-T2 기법을 이용한 소음감소의 유용성 (Usefulness of Acoustic Noise Reduction in Brain MRI Using Quiet-T2)

  • 이세지;김영근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제39권1호
    • /
    • pp.51-57
    • /
    • 2016
  • 뇌 자기공명영상(Magnetic Resornance Imaging; MRI)에서 검사 중 발생되는 소음을 줄이기 위한 기법으로 경사 파형을 변경한 Quiet $T_2$-weighted Turbo Spin-Echo(이하 Q-$T_2$)와 일반적으로 사용되는 $T_2$-weighted Turbo Spin-Echo(이하 $T_2$) 영상의 소음수준 및 영상의 질을 비교하여 그 유용성을 알아보고자 하였다. 3.0T MR 기기로 뇌 MR 검사를 받은 60명(남자 29명, 여자 31명, 평균 연령 60.1세)의 환자를 대상으로 하였다. Q-$T_2$$T_2$ 각각의 영상에서 소음 및 심박동수를 측정하였다. 정량적 분석은 Q-$T_2$$T_2$의 SNR, CNR, SIR 값을 측정한 뒤 독립표본 T검정을 이용하여 통계적 분석을 하였다. 정성적 분석은 Q-$T_2$$T_2$의 전체적인 영상의 질에 대하여 육안으로 평가하였다. 평가는 5점 척도로서 우수(excellent) 5점, 양호(good) 4점, 보통(fair) 3점, 불량(poor) 2점, 평가불가(unacceptable) 1점으로 평가하였다. Q-$T_2$$T_2$ 검사 중 평균소음과 peak소음은 Q-$T_2$가 기존 $T_2$에 비해 각각 $15dB_A$, $10dB_A$ 감소하였다. 또한 각각의 검사 중 120초 동안 심박동수의 평균값은 Q-$T_2$에서 더 낮은 값으로 나타났지만 통계적인 유의성은 없었다. 정량적 분석의 결과 CNR과 SIR은 유의한 차이가 없었으며, SNR은 Q-$T_2$가 더 낮은 평균값을 보임으로서 유의한 차이를 보였다(p<0.05). 정성적 분석은 59개의 Q-$T_2$$T_2$ 영상의 질이 동일하게 우수(excellent) 5점으로 평가되었으며, 1개의 영상에서 모션 아티팩트로 인해 양호(good) 4점으로 평가되었다. Q-$T_2$는 기존의 $T_2$와 같이 검사시간 및 진단의 정확도는 동일하지만 소음을 효과적으로 감소시킬 수 있으며, 이로인하여 환자 편의를 향상시킬 수 있을 것으로 사료된다.

Kinematic Effects of Newly Designed Knee-Ankle-Foot Orthosis With Oil Damper Unit on Gait in People With Hemiparesis

  • Park, Hyung-Ki;Kim, Tack-Hoon;Choi, Houng-Sik;Roh, Jung-Suk;Cynn, Heon-Seock;Kim, Jong-Man
    • 한국전문물리치료학회지
    • /
    • 제20권1호
    • /
    • pp.64-73
    • /
    • 2013
  • The purposes of this study were to develop a new orthosis controlling ankle and knee joint motion during the gait cycle and to identify the effects of the newly designed orthosis on gait kinematics and tempospatial parameters, including coordination of the extremities in stroke patients. Fifteen individuals who had sustained a stroke, onset was 16 months, participated in this study. Before application of the measurement equipment the subjects were accustomed to walking on the ankle-foot orthosis (AFO) or stance control knee with knee flexion assisted-oil damper ankle-foot orthosis (SCKAFO) for 5 minutes. Fifteen patients were investigated for 45 days with a 3-day interval between sessions. Measurements were walking in fifteen stroke with hemiparesis on the 3D motion analysis system. Comparison of AFO and SCKAFO are gait pattern. The difference between the AFO and SCKAFO conditions was significant in the gait velocity, step length of the right affected side, stance time of both legs, step-length asymmetry ratio, single-support-time asymmetry ratio, ${\phi}$-thigh angle and ${\phi}$-shank angle in the mid swing (p<.001). Using a SCKAFO in stroke patients has shown similar to normal walking speeds can be attained for walking efficiency and is therefore desirable. In this study, the support time of the affected leg with the SCKAFO was longer than with the AFO and the asymmetry ratio of single support time decreased by more than with the AFO. This indicates that the SCKAFO was effective for improving gait symmetry, single-support-time symmetry. This may be due to the decrease of gait asymmetry. Thus, the newly designed SCKAFO may be useful for promoting gait performance by improving the coordination of the extremity and decreasing gait asymmetry in chronic stroke patients.

정상인의 내림 경사로 보행 시 경사각에 따른 하지 관절의 삼차원적 동작 분석 (The 3-D Motion Analysis of Kinematic Variety on Lower Extremities During Ramp Descent at Different Inclinations)

  • 한진태;김식현;배성수
    • 한국전문물리치료학회지
    • /
    • 제13권2호
    • /
    • pp.16-25
    • /
    • 2006
  • The aim of this study was to investigate the kinematics of young adults during descent ramp climbing at different inclinations. Twenty-three subjects descended four steps at four different inclinations (level, $-8^{\circ}$, $-16^{\circ}$, $-24^{\circ}$). The 3-D kinematics were measured by a camera-based Falcon System. The data were analyzed using one-way ANOVA and the Student-Newman-Keuls test. The kinematics of descent ramp walking could be clearly distinguished from the kinematics of level walking. On a sagittal plane, the ankle joint was more plantar flexed at initial contact with $-16^{\circ}/-24^{\circ}$ inclination, was decreased in the toe off position with all inclinations (p<.001),and was decreased at maximum plantar flexion during the swing phase (p<.001). The knee joint was more flexed at initial contact with the $-24^{\circ}$ inclination (p<.001), was more flexed in the toe off position with all inclinations (p<.001), and was more flexed at minimum flexion during stance phase and at maximum flexion during swing phase with $-16^{\circ}$, $-24^{\circ}$ inclination (p<.001). The hip joint was more flexed in the toe off position with $-16^{\circ}$, $-24^{\circ}$ inclination and was deceased at maximum extension during stance phase with $-16^{\circ}$, $-24^{\circ}$ inclination (p<.05). In the frontal plane, the ankle joint was more everted at maximum eversion during stance phase with $-16^{\circ}/-24^{\circ}$ inclination (p<.01) and was decreased at maximum inversion during swing phase with $-16^{\circ}$, $-24^{\circ}$ inclination (p<.01). The knee joint was more increased at maximum varus during stance phase with $-16^{\circ}/-24^{\circ}$ inclination (p<.001). The hip joint was deceased at maximum adduction during stance phase with $-24^{\circ}$ inclination (p<.05). In a horizontal plane, only the knee joint was increased at maximum internal rotation during stance phase with $-24^{\circ}$ inclination (p<.05). In descent ramp walking, the different gait patterns occurred at an inclination of over $16^{\circ}$ on the descending ramp in the sagittal and frontal planes. These results suggest that there is a certain inclination angle or angular range where subjects do switch between level walking and descent ramp walking gait patterns.

  • PDF

정상인의 오름 경사로 보행 시 경사각에 따른 하지 관절의 삼차원적 동작 분석 (The 3-D Motion Analysis of Kinematic Variety on Lower Extremity during Ramp Ascent at Different Inclinations)

  • 한진태;이종대;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제17권4호
    • /
    • pp.633-650
    • /
    • 2005
  • The aim of this study was to investigate the kinematics of young adults during ascent ramp climbing at different inclinations. Twenty-three subjects ascended a four step at four different inclinations(level, $8^{\circ},\;16^{\circ},\;24^{\circ}$). The 3-D kinematics was analysed by a camera-based falcon system. Groups difference was tested with one -way ANOVA and SNK test. The different kinematic patterns of ramp ascent were analysed and compared to level walking patterns. The kinematics of ramp walking could be clearly distinguished from the kinematics of level walking. In sagittal plane, Ankle joint was more dorsiflexed at initial contact and Max. dorsiflex. during stance phase with $16^{\circ},\;24^{\circ}$ inclination and more plantarflexed at toe off and Max. plantarflex. during swing phase with $24^{\circ}$(p<.001). Knee joint was more flexed at initial contact with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was more flexed at initial contact and Max. flex. during swing phase with $16^{\circ},\;24^{\circ}$ inclination and at toe off with $24^{\circ}$(p<.001) and was more extended at Max. ext. during stance phase with $24^{\circ}$(p<.05). In frontal plane, ankle joint was more everted at Max. eversion. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Knee joint was more increased at Max. varus. during stance phase with $16^{\circ},\;24^{\circ}$ inclination(p<.001). Hip joint was not differentiated with different inclinations. In horizontal plane, all joints were not differentiated with different inclinations. Conclusionally, In ascent ramp walking, the different gait pattern generally occurred at over $16^{\circ}$ on the ascending ramp in sagittal and frontal plane. These results suggest that there is a certain inclination angle or angular range where subjects do switch between a level walking and a ascent ramp walking gait pattern. This shows their motor control strategy between level and ascent ramp walking. Further studies are necessary to confirm and detect the ascent ramp gait patterns.

  • PDF

뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성 (Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay)

  • 변재후;박명환;이진완
    • 대한디지털의료영상학회논문지
    • /
    • 제16권1호
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

旋網의 沈降 抵抗 解析 - 2. 網地材料와 沈子量 다른 模型網의 경우 - (An Analysis on the Sinking Resistance of Purse Seine - 2. In the Case of the Model Purse Seine with Different Netting Material and Sinkers -)

  • 김석종
    • 수산해양기술연구
    • /
    • 제40권1호
    • /
    • pp.29-36
    • /
    • 2004
  • 선망의 침강 저항 특성을 해명하기 위한 기초 연구로서, 망지의 재료가 다르고 침자량이 동일한 선망 모형의 침강특성을 해석하였다. 실험에 사용한 선망은, 그물실의 직경 및 발의 길이가 같은 폴리프로피렌系 (밀도 0.91g/cm$cm^3$), 폴리아미드系 (밀도 1.14g/cm$cm^3$) 및 폴리에스터系 (밀도 1.38g/cm$cm^3$)의 매듭 없는 망지를 사용하여, 뜸줄의 길이 420cm, 그물의 폭 86cm가 되도록 제작하였다. 이 그물들의 발줄에 침자를 25g, 45g, 60g 의 3 단계로 바꾸어 9종류의 모형그물을 만들고, 각각 PP-25, PA-25, PES-25, PP-45, PA-45, PES-45, PP-60, PA-60 및 PES-60그물이라고 이름을 붙였다. 회류수조의 수로 위에 투망장치를 설치해서 정지 상태의 수중에 투망하고, 관측부 전면에 설치한 비디오 카메라를 이용하여 촬영 녹화하였다. 그리고, 그물에 표시한 측정점의 좌표를 화상해석장치로 읽고 실험치를 구하였다. 여기서, 선망의 수직방향의 침강운동을 나타낸 이론식을 이용하여 수치해석을 행하였는데, 그 결과는 다음과 같다. 1. 침자량이 60g일 때, 아랫자락의 평균 침강속도는 PES그물 12.2 cm/sec로 가장 빠르고, PA그물 11.4 cm/sec, PP 그물 10.7cm/sec 순으로 늦게 나타났다. 2. 망지의 저항계수 $K_D$는, 계산결과 $K_D=0.09(\frac{\rho}{\rho_w})^4$의 관계식으로 나타낼 수 있었다. 3. 그물다발의 저항계수 $C_R$은, 계산결과 $C_R=0.91(\frac{\rho}{\rho_w})$의 관계식으로 나타낼 수 있었다. 4. 선망 투망후 경과시간에 따른 그물 아랫자락의 도달수심에 대한 실험치와 계산치의 관계는 상관성이 매우 높아, 침자량이 25g일 때 meas.=1.04 cal., 45g일 때 meas.=0.99cal.였으며, 60g일 때 meas.=0.98cal.의 관계를 나타냈다.

기계경비시스템의 기술 변화추세와 개발전망 (Trend and future prospect on the development of technology for electronic security system)

  • 정태황;서승영
    • 시큐리티연구
    • /
    • 제19호
    • /
    • pp.225-244
    • /
    • 2009
  • 기계경비시스템은 대부분 전자 정보 통신 기기로 구성되어 있기 때문에 정보통신환경의 변화는 기계경비시스템의 기술, 운영체계, 운영방법 등에 영향을 미치게 된다. 본 연구는 기계경비시스템의 기술개발 동향 및 실태를 분석하고 기술개발 전망을 제시하는데 있다. 본 연구는 문헌연구와 기계경비시스템을 사용하는 수요자와 공급자와의 면담을 통한 분석과, 기술개발업자와 시스템 설치 기술자를 대상으로 한 설문조사를 통해 분석결과에 대한 검증을 실시하였다. 국제적으로 경쟁력이 있는 DVR 기술은 본래의 기능인 영상녹화 기능을 위주로 Motion Detection 기능과 상황변화 인식 기능, 목표물 추적 기능 등과 같은 다양한 기능을 수행할 수 있는 하이브리드 DVR 기술개발 쪽으로 진행될 것이며, 상황변화를 인식할 수 있는 기술은 현장에 설치된 많은 카메라를 소수의 인원이 효과적으로 감시할 수 있게 하여 기존의 CCTV시스템의 기능을 보다 향상시킬 수 있을 것이다. 그리고 영상전송기능을 수행하는 인터넷 서버기술과 영상인식 소프트웨어가 카메라에 내장된 'Embedded IP카메라' 기술개발은 CCTV시스템의 구성체계를 보다 간소화 시킬 수 있을 것이다. 생체인식 중 지문인식기술과 얼굴인식기술은 국제적인 경쟁력을 가지고 기술개발이 진행되지만 얼굴인식기술은 인식기술에 있어서는 선진국과 비슷한 수준인 것으로 평가되고 있으나 인식거리를 확보하는 기술과 감시 기능, 3D인식 기술부분에 있어 다소 신뢰성이 떨어져 이를 보완하기 위한 지속적인 개발이 이루어질 것이다. RFID의 무선인식과 추적기능은 사람 또는 차량의 출입통제나 물품의 반입 반출의 감시 통제 등을 위해 유용하게 적용될 것으로 평가되고 있어 RFID의 하드웨어와 소프트웨어 기술개발이 활발하게 진행될 것으로 전망되지만 시장여건과 새로운 제품 도입을 꺼리고 수입 의존도가 높은 현상을 개선하기 위하여 개발된 제품을 사용할 수 있는 여건 조성 등 기술개발을 촉진하기 위한 적극적인 지원이 필요한 것으로 분석된다. 행동패턴을 인식하여 침입상황을 감지하는 센서기술은 기존의 오작동이 많은 공간감지 센서를 대신하여 경보신호의 신뢰도를 향상시켜 자신있는 현장대응을 가능하게 해줄 수 있는 기술로 적극적으로 개발이 이루어질 것으로 전망된다. 행동패턴인식기술과 영상변화를 탐지하고 분석하는 영상인식기술은 유사한 기술로 서로 연계될 수 있으며, 경보신호전송 기술, 영상추적기술, RFID의 무선인식 및 추적 기술, 그리고 이를 관리하기 위한 미들웨어 기술을 통합하여 이상상황에 보다 효과적으로 대응할 수 있는 통합관제시스템을 구축할 수 있을 것이다.

  • PDF