• Title/Summary/Keyword: 3D motion

Search Result 2,047, Processing Time 0.035 seconds

A Study of 100 tonf Tensile Load for SMART Mooring Line Monitoring System Considering Polymer Fiber Creep Characteristics

  • Chung, Joseph Chul;Lee, Michael Myung-Sub;Kang, Sung Ho
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.4
    • /
    • pp.266-272
    • /
    • 2021
  • Mooring systems are among the most important elements employed to control the motion of floating offshore structures on the sea. Considering the use of polymer material, a new method is proposed to address the creep characteristics rather than the method of using a tension load cell for measuring the tension of the mooring line. This study uses a synthetic mooring rope made from a polymer material, which usually consists of three parts: center, eye, and splice, and which makes a joint for two successive ropes. We integrate the optical sensor into the synthetic mooring ropes to measure the rope tension. The different structure of the mooring line in the longitudinal direction can be used to measure the loads with the entire mooring configuration in series, which can be defined as SMART (Smart Mooring and Riser Truncation) mooring. To determine the characteristics of the basic SMART mooring, a SMART mooring with a diameter of 3 mm made of three different polymer materials is observed to change the wavelength that responds as the length changes. By performing the longitudinal tension experiment using three different SMART moorings, it was confirmed that there were linear wavelength changes in the response characteristics of the 3-mm-diameter SMART moorings. A 54-mm-diameter SMART mooring is produced to measure the response of longitudinal tension on the center, eye, and splice of the mooring, and a longitudinal tension of 100 t in step-by-step applied for the Maintained Test and Fatigue Cycle Test is conducted. By performing a longitudinal tension experiment, wavelength changes were detected in the center, eye, and splice position of the SMART moorings. The results obtained from each part of the installed sensors indicated a different strain measurement depending on the position of the SMART moorings. The variation of the strain measurement with the position was more than twice the result of the difference measurement, while the applied external load increased step-by-step. It appears that there is a correlation with an externally generated longitudinal tensional force depending on the cross-sectional area of each part of the SMART mooring.

Effect of Surface Environment on Front Squat of Crossfit Athletes (지면환경이 크로스핏 선수의 프론트 스쿼트에 미치는 영향)

  • Jang, Yootae;Yoon, Sukhoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.32 no.2
    • /
    • pp.49-55
    • /
    • 2022
  • Objective: This study aims to verify the front squat motions using by two different surfaces, thereby elucidating the grounds for effective training environment that can minimize the risk of injury. Method: Total of 10 healthy male crossfit athletes were recruited for this study (age: 32.30 ± 3.05 yrs., height: 173.70 ± 5.12 cm, body mass: 82.40 ± 6.31 kg, 1RM: 160 ± 13.80 kg). All participants are those who know how to do front squats well with more than five years of crossfit athlete experience. All participants have sufficient experience in front squats on two types of surface which are soft surface (SS) and hard surface (HS). In each surface, participant perform 10reps of the front squat with 80% of the pre-measured 1RM. A 3-dimensional motion analysis with 8 infrared cameras and 2 channels of EMG was performed in this study. Paired sample t-test was used for statistical verification between two surfaces. The significant level was set at α=.05. Results: The significantly decreased rectus femoris muscle activation was found in SS compared with that of HS on phase 1 (p<.05). Also, ROM of ankle joint was significantly increased in the SS compare with that of HS on phase 1 (p<.05). The muscle activity ratio of gluteus maximus/rectus femoris showed a significant difference only in SS compared with that of HS on phase 1 (p<.05). Conclusion: In conclusion, Korean crossfit boxes should consider the use of hard surface, which has a relatively less risk of injury than soft surface, in selecting flooring materials. For the Crossfit athletes, they are also considered appropriate to train on a relatively hard surface.

A simplified directly determination of natural frequencies of CNT: Via aspect ratio

  • Banoqitah, Essam Mohammed;Hussain, Muzamal;Khadimallah, Mohamed A.;Ghandourah, Emad;Yahya, Ahmad;Basha, Muhammad;Alshoaibi, Adil
    • Advances in nano research
    • /
    • v.13 no.3
    • /
    • pp.207-216
    • /
    • 2022
  • In this paper, a novel model is developed for frequency behavior of single walled carbon nanotubes. The governing equation of motion is constructed method based on the Sander theory using Rayleigh-Ritz's method The frequencies enhances on increasing the power law index using simply supported, clamped and clamped free end conditions. The frequency curve for C-F is less than other conditions. It is due to the physical constraints which are applied on the edge of the CNT. It is observed that the C-F boundary condition have less frequencies from the other two conditions. The frequency phenomena for zigzag are insignificant throughout the aspect ratio. Moreover when index of power law is increased then frequencies increases for all boundary conditions. The natural frequency mechanism for the armchair (10, 10) for various values of power law index with different boundary conditions is investigated. Here frequencies decrease on increases the aspect ratio for all boundary conditions. The frequency curves of SS-SS edge condition is composed between the C-C and C-F conditions. The curves of frequency are less significant from small aspect ratio (L/d = 4.86 ~ 8.47) and decreases fast for greater ratios. It is found that the frequencies via aspect ratios, armchair (10, 10) have higher values from zigzag (10, 0). It is due to the material structure which is made by the carbon nanotubes. The power law index have momentous effect on the vibration of single walled carbon nanotubes. The present frequency result is also compared numerically experimentally with Raman Spectroscopy.

Radiologic and clinical outcomes of an arthroscopic bridging graft for irreparable rotator cuff tears with a modified Mason-Allen stitch using a plantaris tendon autograft: a case series with minimum 2-year outcomes

  • Hyun-Gyu Seok;Sam-Guk Park
    • Clinics in Shoulder and Elbow
    • /
    • v.26 no.4
    • /
    • pp.406-415
    • /
    • 2023
  • Background: Surgical management of a massive rotator cuff tear (RCT) is always challenging. This study describes the clinical and radiological outcomes of patients who underwent bridging grafts using a plantaris tendon for an irreparable RCT. Methods: Thirteen patients with a massive RCT were treated with arthroscopic interposition of a folded plantaris tendon autograft between June 2017 and January 2020. For clinical evaluation, a visual analog scale (VAS), American Shoulder and Elbow Surgeons (ASES) score, Disabilities of the Arm, Shoulder, and Hand (DASH) score, Constant-Murley score, and range of motion values were collected. For radiographic evaluation, standardized magnetic resonance imaging and ultrasonography were performed to check the integrity of the interposed tendon. Results: A statistically significant improvement at the final follow-up was evident in scores for the VAS (-3.0, P=0.003), ASES (24.9, P=0.002), D ASH (-20.6, P=0.001), and Constant-Murley values (14.2, P=0.010). In addition, significant improvement was shown in postoperative flexion (17.3°, P=0.026) and external rotation (27.7°, P<0.001). In postoperative radiologic evaluations, the interposed tendons were intact at the last examination in 12 of the 13 patients. No complications related to donor sites were reported. Conclusions: An arthroscopic bridging graft for irreparable RCTs using a modified Mason-Allen stitch and a plantaris autograft resulted in improved short-term radiological and clinical outcomes. Graft integrity was maintained for up to 2 years in most patients. Level of evidence: IV.

Ablative Mechanism of SiC Coated Carbon/carbon Composites with Ratio of Oxygen to Fuel at Combusion Test (연소시험에서 산소와 연료 비에 따른 탄화규소로 코팅된 탄소/ 탄소 복합재의 삭마 메커니즘)

  • Zhang, Eun-Hee;Kim, Zeong-Baek;Joo, Hyeok-Jong
    • Applied Chemistry for Engineering
    • /
    • v.18 no.3
    • /
    • pp.227-233
    • /
    • 2007
  • Carbon/carbon (C/C) composites as unique materials possess exceptional thermal resistance with light weight, high stiffness, and strength even at high temperature. However, one serious obstacle for application of the C/C composites is their poor oxidation resistance in high temperature oxidizing environments. SiC coating has been employed to protect the composites from oxidation. This study explored combustion characteristics of 4-directional (4D) carbon/carbon composites using liquid fuel rocket engine to investigate ablative motion of the materials. C/C composites were made of coal tar pitch as a matrix precursor, and heat-treated at $2300^{\circ}C$. Throughout repeated densification process, the density of the material reached $1.903g/cm^3$. After machining 4D C/C composites, the nozzle surface was coated by a SiC layer by pack-cementation method to improve oxidation resistance. Erosion characteristics of SiC-coated C/C composites were measured as function of the ratio of oxygen to fuel. The morphological change of the composites after combustion test was investigated using SEM and erosion mechanism also was discussed.

Patients with brain metastases the usefulness of contrast-enhanced FLAIR images after delay (뇌전이 환자의 조영 증강 후 지연 FLAIR 영상의 유용성)

  • Byun, Jae-Hu;Park, Myung-Hwan;Lee, Jin-Wan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.1
    • /
    • pp.13-19
    • /
    • 2014
  • Purpose: FLAIR image is beneficial for the diagnosis of various bran diseases including ischemic CVS, brain tumors and infections. However the border between the legion of brain metastasis and surrounding edema may not be clear. Therefore, this study aims to investigate the practical benefits of delayed imaging by comparing the image from a patient with brain metastasis before a contrast enhancement and the image 10 minutes after a contrast enhancement. Materials and methods: Of the 92 people who underwent MRI brain metastases in suspected patients 13 people in three patients there is no video to target the 37 people confirmed cases, and motion artifacts brain metastases in our hospital June-December 2013, 18 people measurement position except for the three incorrect patient (male: 11 people, female: 7 people, average age: 60 years) in the target, test equipment, 3.0T MR System (ACHIEVA Release, Philips, I was 8ChannelSENSE Head Coil use Best, and the Netherlands). TR 11000 ms, TE 125 ms, TI2800 ms, Slice Thickness 5 mm, gap 5 mm, is a Slice number 21, the parameters of the 3D FFE, T2 FLAIR variable that was used to test, TR 8.1 ms, TE 3.7 ms, Slice number 240 I set to. The experiment was conducted by acquiring the FLAIR prior to contrast enhancement (heretofore referred to as Pre FLAIR), and acquiring the 3D FFE CE five minutes after the contrast enhancement, and recomposing the images in an axial plane of S/T 3mm, G 0mm (heretofore referred to as MPR TRA CE). Using the FLAIR 10 minutes after the contrast enhancement (heretofore referred to as Post FLAIR) and Pi-View, a retrospective study was conducted. Using MRIcro on the image of a patient confirmed for his diagnosis, the images before and after the contrast media, as well as the CNR and SNR of the MPR TRA CE images of the lesion and the site absent of lesion were compared and analyzed using a one-way analysis of variance. Results: CNR for Pre FLAIR and Post FLAIR were 34.35 and 60.13, respectively, with MPR TRA CE at 23.77 showing no significant difference (p<0.050). Post-experiment analysis shows a difference between Pre FLAIR and Post FLAIR in terms of CNR (p<0.050), but no difference in CNR between Post FLAIR and MPR TRA CE (p>0.050), indicating that the contrast media had an effect only on Pre FLAIR and Post FLAIR. The SNR for the normal site Pre FLAIR was 106.43, and for the lesion site 140.79. Post FLAIR for the normal site was 107.79, and for the lesion site 167.91. MPR TRA CE for the normal site was 140.23 and for the lesion site 183.19, showing significant difference (p<0.050), and post-experiment analysis shows that there was a difference in SNR only on the lesion sites for Pre FLAIR and Post FLAIR (p<0.050). There was no difference in SNR between the normal site and lesion site for Post FLAIR and MPR TRA CE, indicating no effect from the contrast media (p>0.050). Conclusions: This experiment shows that Post FLAIR has a higher contrast than Pre FLAIR, and a higher SNR for lesions, It was not not statistically significant and MPR TRA CE but CNR came out high. Inspection of post-contrast which is used in a high magnetic field is frequently used images of 3D T1 but, since the signal of the contrast medium and the blood flow is included, this method can be diagnostic accuracy is reduced, it is believed that when used in combination with Post FLAIR, and that can provide video information added to the diagnosis of brain metastases.

  • PDF

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

The new explore of the animated content using OculusVR - Focusing on the VR platform and killer content - (오큘러스 VR (Oculus VR)를 이용한 애니메이션 콘텐츠의 새로운 모색 - VR 플랫폼과 킬러콘텐츠를 중심으로 -)

  • Lee, Jong-Han
    • Cartoon and Animation Studies
    • /
    • s.45
    • /
    • pp.197-214
    • /
    • 2016
  • Augmented Reality, virtual reality in recently attracted attention throughout the world. and Mix them mixed reality etc., it has had a significant impact on the overall pop culture beyond the scope of science and technology. The world's leading IT company : Google, Apple, Samsung, Microsoft, Sony, LG is focusing on development of AR, VR technology for the public. The many large and small companies developed VR hardware, VR software, VR content. It does not look that makes a human a human operation in the cognitive experience of certain places or situations or invisible through Specific platforms or program is Encompass a common technique that a realization of the virtual space. In particular, out of the three-dimensional image reveals the limitations of the conventional two-dimensional structure - 180, 360 degree images provided by the subjective and objective symptoms such as vision and sense of time and got participants to select it. VR technology that can significantly induce the commitment and participation is Industry as well as to the general public which leads to the attention of colostrum. It was introduced more than 10 related VR works Year 2015 Sundance Film Festival New Frontier program. The appearance VR content : medical, architecture, shopping, movies, animations. Also, 360 individuals can be produced by the camera / video sharing VR is becoming an interactive tunnel between two possible users. Nevertheless, This confusion of values, moral degeneration and the realization of a virtual space that has been pointed out that the inherent. 4K or HUD, location tracking, motion sensors, processing power, and superior 3D graphics, touch, smell, 4D technology, 3D audio technology - It developed more than ever and possible approaches to reality. Thereafter, This is because the moral degeneration, identity, generational conflict, and escapism concerns. Animation is also seeking costs in this category Reality. Despite the similarities rather it has that image, and may be the reason that the animation is pushed back to the VR content creation. However, it is focused on the game and VR technology and the platform that is entertaining, but also seek new points within the animation staying in the flat Given that eventually consist of visual images is clear that VR sought. Finally, What is the reality created in the virtual space using VR technology could be applied to the animation? So it can be seen that the common interest is research on what methods and means applied.

Angular Differences between the Lower Extremity and the Ground that Express Maximum Core Muscle Activation According to Core-strengthening Exercises

  • Son, Nam Jeong;Jun, Hyun Jeong;Yi, Kyung Ock
    • Korean Journal of Applied Biomechanics
    • /
    • v.27 no.4
    • /
    • pp.247-255
    • /
    • 2017
  • Objective: The purpose of this study was to investigate the maximum core muscle activation angle according to core-strengthening exercises. Method: Twenty-six young female football players (age: $17.84{\pm}0.80years$, height: $163.08{\pm}5.25cm$, weight: $54.96{\pm}7.41kg$) registered in the Korea Football Association from D High School located in Seoul were the subjects of this research. An electromyogram (Noraxon, USA) was used for monitoring the maximum core muscle contraction activity. Results: The angle for the maximum core muscle strength per core exercise and muscle was the smallest for the upper rectus abdominis in the windshield wiper exercise. The angle of the vastus medialis was significantly the largest. The range of angles at which the maximum strength was observed for each core exercise were as follows: 1) abdominal flutter kicks ($11{\sim}40^{\circ}$), 2) leg raises ($21{\sim}34^{\circ}$), 3) scissors ($45{\sim}66^{\circ}$), 4) knee to elbow sit-ups ($42{\sim}64^{\circ}$), 5) reverse crunches ($9{\sim}40^{\circ}$), 6) butt-ups ($24{\sim}32^{\circ}$), 7) V sit-ups ($5{\sim}24^{\circ}$), 8) windshield wipers ($11{\sim}20^{\circ}$), 9) bird dog ($11{\sim}18^{\circ}$), and 10) raised leg plank ($38{\sim}50^{\circ}$). Conclusion: Four kinds of motion could be classified according to the range of angles at which the core muscles were maximally activated. The first group involves the range of motion that gives the maximum muscle strength when the lower extremity and ground angle was between $5^{\circ}$ and $24^{\circ}$, such as the V sit-ups, windshield wipers, and bird dog. The second group comprised the flutter kicks and reverse crunches at an angle between $9^{\circ}$ and $40^{\circ}$. The third group comprised the leg raise and butt-up exercises at an angle between $21^{\circ}$ and $34^{\circ}$. The fourth group included the scissors, knee to elbow sit-ups, and raised leg plank at an angle between $38^{\circ}$ and $66^{\circ}$. These results may be useful as basic data for core movement and core muscle training according to the purpose of exercise.

The Effect of Barrel Vibration Intensity to the Plating Thickness Distribution

  • Lee, Jun-Ho;Roselle D. Llido
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 1999.10a
    • /
    • pp.15-15
    • /
    • 1999
  • In chip plating, several parameters must be taken into consideration. Current density, solution concentration, pH, solution temperature, components volume, chip and media ratio, barrel geometrical shape were most likely found to have an effect to the process yields. The 3 types of barrels utilized in chip plating industry are the conventional rotating barrel. vibrational barrel (vibarrel), and the centrifugal type. Conventional rotating barrel is a close type and is commonly used. The components inside the barrel are circulated by the barrel's rotation at a horizontal axis. Process yield has known to have higher thickness deviation. The vibrational barrel is an open type which offers a wide exposure to electrolyte resulting to a stable thickness deviation. It rotates in a vertical axis coupled with multi-vibration action to facilitate mixed up and easy transportation of components, The centrifugal barrel has its plated work centrifugally compacted against the cathode ring for superior electrical contact with simultaneous rotary motion. This experiment has determined the effect of barrel vibration intensity to the plating thickness distribution. The procedures carried out in the experiment involved the overall plating process., cleaning, rinse, Nickel plating, Tin-Lead plating. Plating time was adjusted to meet the required specification. All other parameters were maintained constant. Two trials were performed to confirm the consistency of the result. The thickness data of the experiment conducted showed that the average mean value obtained from higher vibrational intensity is nearer to the standard mean. The distribution curve shown has a narrower specification limits and it has a reduced variation around the target value, Generally, intensity control in vi-barrel facilitates mixed up and easy transportation of components, However, it is desirable to maintain an optimum vibration intensity to prevent solution intrusion into the chips' internal electrode. A cathodic reaction can occur in the interface of the external and internal electrode. $2HD{\;}+{\;}e{\;}{\rightarrow}20H{\;}+{\;}H_2$ Hydrogen can penetrate into the body and create pressure which can cause cracks. At high intensity, the chip's motion becomes stronger, its contact between each other is delayed and so plating action is being controlled. However, the strong impact created by its collision can damage the external electrode's structure thereby resulting to bad plating condition. 1 lot of chip was divided into two equal partion. Each portion was loaded to the same barrel one after the other. Nickel plating and tin-lead plating was performed in the same station. Portion A maintained the normal barrel vibration intensity and portion B vibration intensity was increased two steps higher. All other parameters, current, solution condition were maintained constant. Generally, plating method find procedures were carried out in a best way to maintained the best plating condition. After plating, samples were taken out from each portion. molded and polished. Plating thickness was investigated for both. To check consistency of results. 2nd trial was done now using different lot of another characteristics.

  • PDF