• Title/Summary/Keyword: 3D dose evaluation

Search Result 242, Processing Time 0.029 seconds

Evaluation of Every Other Day - Cone Beam Computed Tomography in Image Guided Radiation Therapy for Prostate Cancer (전립선암의 영상유도방사선치료 시 격일 콘빔 CT 적용의 유용성 평가)

  • Park, Byoung Suk;Ahn, Jong Ho;Kim, Jong Sik;Song, Ki Won
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.2
    • /
    • pp.289-295
    • /
    • 2014
  • Purpose : Cone Beam Computed Tomography(CBCT) in Image Guided Radiation Therapy(IGRT), Set-up error can be reduced but exposure dose of the patient due to CBCT will increase. Through this study, we are to evaluate by making a scenario with the implementation period of CBCT as every other day. Materials and Methods : Of prostate cancer patients, 9 patients who got a Intensity Modulated Radiation Therapy(IMRT) with CBCT in IGRT were analyzed. Based on values corrected by analyzing set-up error by using CBCT every day during actual treatment, we created a scenario that conducts CBCT every other day. After applying set-up error values of the day not performing CBCT in the scenario to the treatment planning system(Pinnacle 9.2, Philips, USA) by moving them from the treatment iso-center during actual treatment, we established re-treatment plan under the same conditions as actual treatment. Based on this, the dose distribution of normal organs and Planning Target Volume(PTV) was compared and analyzed. Results : In the scenario that performs CBCT every other day based on set-up error values when conducting CBCT every day, average X-axis : $0.2{\pm}0.73mm$, Y-axis : $0.1{\pm}0.58mm$, Z-axis : $-1.3{\pm}1.17mm$ difference was shown. This was applied to the treatment planning to establish re-treatment plan and dose distribution was evaluated and as a result, Dmean : -0.17 Gy, D99% : -0.71 Gy of PTV difference was shown in comparison with the result obtained when carrying out CBCT every day. As for normal organs, V66 : 1.55% of rectal wall, V66 : -0.76% of bladder difference was shown. Conclusion : In case of a CBCT perform every other day could reduce exposure dose and additional treatment time. And it is thought to be able to consider the application depending on the condition of the patient because the difference in the dose distribution of normal organs, PTV is not large.

Application of Gamma Irradiation for the Microbiological Safety of Fried-Frozen Cheese Ball (냉동치즈볼의 미생물학적 안전성 확보를 위한 감마선 조사기술의 이용)

  • Lee, Ju-Woon;Kim, Jae-Hun;Kim, Jang-Ho;Oh, Sang-Hee;Seo, Ji-Hyun;Kim, Cheon-Jei;Cheong, Sung-Hee;Byun, Myung-Woo
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.5
    • /
    • pp.729-733
    • /
    • 2005
  • This study was conducted to sanitize fried-frozen cheese ball by gamma irradiation. Total aerobic bacteria and yeasts and molds counts were 4.4 and 2.8 log CFU/g in non-irradiated sample, respectively. Microorganisms were decreased with increase of irradiation dose $(D_{10}=1.25\;kGy)$, and were not detected in samples irradiated at 3 kGy or more $(<10^2\;CFU/g)$. $D_{10}$ value for Escherichia coli (KCTC 1682) was 0.25 kGy. TBA (2-thiobarbituric acid) values were increased as irradiation dose was increased, but there was no significant difference between non-irradiated and irradiated samples at 3 kGy or less (p<0.05). The results of sensory evaluation showed that there was no significant difference between non-irradiated and irradiated samples at 3 kGy or less, the sensory scores were decreased with irradiation at 5 kGy or more (p<0.05). These results indicated that gamma irradiation at 3 kGy was considered to be an effective treatment to ensure the microbiological safety of fried-frozen cheese balls without any sensorial change, even though further studies should be investigated to reduce detrimental effects induced by irradiation.

Toxicity Evaluation of Effluent Gases from a Residental Fire by Rats (연립 주택 화재시 유독가스 방출 특성과 Rats를 이용한 독성평가)

  • Kim, Hong;Kang, Young-Goo;Kim, Dong-Hyun;Jung, Ki-Chang;Lee, Chang-Seop;Kim, Woon-Hyung
    • Fire Science and Engineering
    • /
    • v.16 no.3
    • /
    • pp.12-15
    • /
    • 2002
  • It has long been recognized that exposure to fire-induced toxic gases is a fatal hazard confront-ing people in fires. In this study, an indoor fire experiment was conducted in an unoccupied residential building located in An-san city, Kyoung-gi province, and the composition of effluent gases, which include CO, $CO_2$, $O_2$, $SO_2$, NO and $NO_2$, were measured by a gas analyzer. A group of lab rats were exposed to the toxic gases released from fire, and the blood samples of the rats were gathered every 2 minutes. A toxicity evaluation was conducted by analyzing the concentrations of Glucose, AST(GOT), ALT(GPT), CBC Count and CO(carboxy)-Hb in the blood samples. Shown from the analysis is the does-response relationship between the CO concentration that rats were exposed to and the CO-Hb concentration in rat blood.

Evaluation of 3-week Repeated Dose Oral Toxicity on Amomum tsao-ko Extract in Balb/c Mice (Balb/c 마우스에서 초과 추출물의 3주간 반복 경구투여 독성평가)

  • Park, Ju-Hyeong;Cho, Young-Rak;Ko, Hye-Jin;Jeong, Wonsik;Ahn, Eun-Kyung;Oh, Junho;Oh, Joa Sub
    • Journal of Applied Biological Chemistry
    • /
    • v.58 no.2
    • /
    • pp.139-143
    • /
    • 2015
  • In the present study, we investigated the oral toxicity of Amomum tsao-ko Crevost et Lemaire, (Zingiberaceae) extract in Balb/c mice (BALB, n=60) for 3 weeks. Balb/c mice (10 mice/group, 6 group, $20{\pm}2g$, 6 weeks) were orally administered for 21 days, with dosage of 250, 500, 1000, 2000 mg/kg/day. Ethanol extract of A. tsao-ko did not affect any significant change of mortality, clinical signs, organs and body weights. Also, there were not significantly difference from the naive group (control) in hematological and serum biochemical examination. Consequently, these findings indicate that 3-week treatment with the ethanol extract of A. tsao-ko was not any toxic effects in Balb/c mice and the no-observed adverse effect level (NOAEL) for oral toxicity was determined to be 2000 mg/kg/day under our experimental conditions.

Antioxidant, antinociceptive activity and general toxicity study of Dendrophthoe falcata and isolation of quercitrin as the major component

  • Hasan, Md Shihab;Ahmed, Md Iqbal;Mondal, Sukla;Masud, Mohammad Methedi;Sadhu, Samir Kumar;Ishibashi, Masami;Uddin, Shaikh Jamal
    • Advances in Traditional Medicine
    • /
    • v.6 no.4
    • /
    • pp.355-360
    • /
    • 2006
  • Plants have been used in traditional medicinal system for centuries. Bangladeshi medicinal plants have received considerable attention from the researchers for evaluation of their bioactivity. As a part of our ongoing research of screening the Bangladeshi medicinal plants, the ethanolic extract of Dendrophthoe falcata have been chosen for the present study. The ethanolic extract of the leaves of the plant have been assessed for their antioxidant, antinociceptive, and general toxicity. The extract showed potent antioxidant activity ($IC_{50}5.1{\mu}g/ml$) using DPPH radical scavenging assay, which is comparable to the standard ascorbic acid ($IC_{50}4.6{\mu}g/ml$). The extract significantly and dose dependently inhibited the acetic acid induced writhing in mice (71.2%, P < 0.001 and 28.0%, P < 0.05 for 500 and 250 mg/kg body weight, respectively). A general toxicity was assessed by a simple and low cost assay using brine shrimp lethality as an indicator. The extract showed low level of toxicity ($LC_{50}100{\mu}g/ml$). Using different chromatographic techniques, quercitrin (quercetin 3-O-${\alpha}$-rhamnoside) was separated as the major component from the extract. The structure was elucidated by detailed 1D and 2D NMR and mass spectral analysis.

Verification of Dose Evaluation of Human Phantom using Geant4 Code (Geant4 코드를 사용한 인체팬텀 선량평가 검증)

  • Jang, Eun-Sung;Choi, Ji-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.529-535
    • /
    • 2020
  • Geant4 is compatible with the Windows operating system in C++ language use, enabling interface functions that link DICOM or software. It was simulated to address the basic structure of the simulation using Geant4/Gate code and to specifically verify the density composition and lung cancer process in the human phantom. It was visualized using the Gate Graphic System, i.e. openGL, Ray Tracer: Ray Tracing by Geant4 Tracing, and using Geant4/Gate code, lung cancer is modeled in the human phantom area in 3D, 4D to verify the simulation progress. Therefore, as a large number of new functions are added to the Gate Code, it is easy to implement accurate human structure and moving organs.

Development of the Monte Carlo Simulation Radiation Dose Assessment Procedure for NORM added Consumer Adhere·Non-Adhere Product based on ICRP 103 (ICRP 103 권고기반의 밀착형·비밀착형 가공제품 사용으로 인한 몬테칼로 전산모사 피폭선량 평가체계 개발)

  • Go, Ho-Jung;Noh, Siwan;Lee, Jae-Ho;Yeom, Yeon-Soo;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.124-131
    • /
    • 2015
  • Radiation exposure to humans can be caused by the gamma rays emitted from natural radioactive elements(such as uranium, thorium and potassium and any of their decay products) of Naturally Occurring Radioactive Materials(NORM) or Technologically Enhanced Naturally Occurring Radioactive Materials(TENORM) added consumer products. In this study, assume that activity of radioactive elements is $^{238}U$, $^{235}U$, $^{232}Th$ $1Bq{\cdot}g^{-1}$, $^{40}K$ $10Bq{\cdot}g^{-1}$ and the gamma rays emitted from these natural radioactive elements radioactive equilibrium state. In this study, reflected End-User circumstances and evaluated annual exposure dose for products based on ICRP reference voxel phantoms and ICRP Recommendation 103 using the Monte Carlo Method. The consumer products classified according to the adhere to the skin(bracelet, necklace, belt-wrist, belt-ankle, belt-knee, moxa stone) or not(gypsum board, anion wallpaper, anion paint), and Geometric Modeling was reflected in Republic of Korea "Residential Living Trend-distributions and Design Guidelines For Common Types of Household.", was designed the Room model($3m{\times}4m{\times}2.8m$, a closed room, conservatively) and the ICRP reference phantom's 3D segmentation and modeling. The end-user's usage time assume that "Development and Application of Korean Exposure Factors." or conservatively 24 hours; in case of unknown. In this study, the results of the effective dose were 0.00003 ~ 0.47636 mSv per year and were confirmed the meaning of necessary for geometric modeling to ICRP reference phantoms through the equivalent dose rate of belt products.

Synthesis and Evaluation of F-18 Labeled 2'-Deoxy-2'-fluoro-5-methyl-1-β-L-arabinofuranosyluracil (L-[18F]FMAU)

  • Jo, Nam-Hyun;Moon, Byung-Seok;Hong, Su-Hee;An, Gwang-Il;Choi, Tae-Hyun;Cheon, Gi-Jeong;Cho, Jung-Hyuck;Yoo, Kyung-Ho;Lee, Kyo-Chul;Oh, Chang-Hyun
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.12
    • /
    • pp.2449-2453
    • /
    • 2007
  • L-[18F]FMAU ([18F]1b) was prepared from the precursor 2-O-[(trifluoromethyl)-sulfonyl]-1,3,5-tri-Obenzoyl- α-L-ribofuranose, by coupling the radioactive fluoro-sugar with the corresponding silylated thymine in 4 steps. The final products, including the α and β anomers, were purified using reverse phase HPLC with an appropriate solvent (5% CH3CN/H2O) at a flow rate of 3.0 mL/min. The total elapsed time of synthesis was about 180-200 min from EOB. The α/β anomeric ratio of the compounds was about 1:9, and the radiochemical purity of the product (β-form) was >98% with decay-corrected yields of 25-35%. All radioactive samples were confirmed using co-injection with pure non-radioactive analogues in every step. In the cellular uptake in vitro test of herpes simplex virus-thymidine kinase (HSV1-TK) gene expressed cells, the percent uptake of injected dose (%ID) of L- and D-FMAU was 37.28 and 65.86, respectively after 240 min incubation. However, the relative uptake (MCA-TK/MCA cellular uptake ratio) of L-FMAU was higher than that of D-FMAU (%ID of L-FMAU, 0.36 and D-FMAU, 0.93 after 240 min incubation in MCA cells). This means that L-FMAU will show better specific HSV1-TK gene expressed cell uptake for selective HSV1-TK gene imaging.

Evaluation of the Usefulness of the Transmittance of Metal Filaments Fabricated by 3D Printers in Radiation Therapy (방사선 치료에서 3D 프린터로 제작된 금속 필라멘트의 투과율에 관한 유용성 평가)

  • Kwon, Kyung-Tae;Jang, Hui-Min;Yoon, Myeong-Seong
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.965-973
    • /
    • 2021
  • Since radiation therapy is irradiated with high-energy X-rays in a variety of at least 20 Gy to 80 Gy, a high dose is administered to the local area where the tumor is located, and various side effects of some normal tissues are expected. Currently, in clinical practice, lead, a representative material, is used as an effort to shield normal tissues, but lead is classified as a heavy metal harmful to the human body, and a large amount of skin contact can cause poisoning. Therefore, this study intends to manufacture a measurement sheet that can compensate for the limitations of lead using the materials Tungsten, Brass, and Copper of the 3D printer of the FDM (Fused Deposition Modeling) method and to investigate the penetration performance. Tungsten mixed filament transmission measurement sheet size was 70 × 70 mm and thickness 1, 2, 4 mm using a 3D printer, and a linear accelerator (TrueBeam STx, S/N: 1187) was measured by irradiating 100 MU at SSD 100 cm and 5 cm in water using a water phantom, an ion chamber (FC-65G), and an elcetrometer (PTW UNIDOSE), and the permeability was evaluated. As a result of increasing the measurement sheet of each material by 1 mm, in the case of Tungsten sheet at 3.8 to 3.9 cm in 6 MV, the thickness of the lead shielding body was thinner than 6.5 cm, and in case of Tungsten sheet at 4.5 to 4.6 cm in 15 MV. The sheet was thinner than the existing lead shielding body thickness of 7 cm, and equivalent performance was confirmed. Through this study, the transmittance measurement sheet produced using Tungsten alloy filaments confirmed the possibility of transmission shielding in the high energy region. It has been confirmed that the usability as a substitute is also excellent. It is thought that it can be provided as basic data for the production of shielding agents with 3D printing technology in the future.

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.