• 제목/요약/키워드: 3D distribution imaging

검색결과 89건 처리시간 0.024초

Comparisons of Object Recognition Performance with 3D Photon Counting & Gray Scale Images

  • Lee, Chung-Ghiu;Moon, In-Kyu
    • Journal of the Optical Society of Korea
    • /
    • 제14권4호
    • /
    • pp.388-394
    • /
    • 2010
  • In this paper the object recognition performance of a photon counting integral imaging system is quantitatively compared with that of a conventional gray scale imaging system. For 3D imaging of objects with a small number of photons, the elemental image set of a 3D scene is obtained using the integral imaging set up. We assume that the elemental image detection follows a Poisson distribution. Computational geometrical ray back propagation algorithm and parametric maximum likelihood estimator are applied to the photon counting elemental image set in order to reconstruct the original 3D scene. To evaluate the photon counting object recognition performance, the normalized correlation peaks between the reconstructed 3D scenes are calculated for the varied and fixed total number of photons in the reconstructed sectional image changing the total number of image channels in the integral imaging system. It is quantitatively illustrated that the recognition performance of the photon counting integral imaging system can be similar to that of a conventional gray scale imaging system as the number of image viewing channels in the photon counting integral imaging (PCII) system is increased up to the threshold point. Also, we present experiments to find the threshold point on the total number of image channels in the PCII system which can guarantee a comparable recognition performance with a gray scale imaging system. To the best of our knowledge, this is the first report on comparisons of object recognition performance with 3D photon counting & gray scale images.

Analytic simulator and image generator of multiple-scattering Compton camera for prompt gamma ray imaging

  • Kim, Soo Mee
    • Biomedical Engineering Letters
    • /
    • 제8권4호
    • /
    • pp.383-392
    • /
    • 2018
  • For prompt gamma ray imaging for biomedical applications and environmental radiation monitoring, we propose herein a multiple-scattering Compton camera (MSCC). MSCC consists of three or more semiconductor layers with good energy resolution, and has potential for simultaneous detection and differentiation of multiple radio-isotopes based on the measured energies, as well as three-dimensional (3D) imaging of the radio-isotope distribution. In this study, we developed an analytic simulator and a 3D image generator for a MSCC, including the physical models of the radiation source emission and detection processes that can be utilized for geometry and performance prediction prior to the construction of a real system. The analytic simulator for a MSCC records coincidence detections of successive interactions in multiple detector layers. In the successive interaction processes, the emission direction of the incident gamma ray, the scattering angle, and the changed traveling path after the Compton scattering interaction in each detector, were determined by a conical surface uniform random number generator (RNG), and by a Klein-Nishina RNG. The 3D image generator has two functions: the recovery of the initial source energy spectrum and the 3D spatial distribution of the source. We evaluated the analytic simulator and image generator with two different energetic point radiation sources (Cs-137 and Co-60) and with an MSCC comprising three detector layers. The recovered initial energies of the incident radiations were well differentiated from the generated MSCC events. Correspondingly, we could obtain a multi-tracer image that combined the two differentiated images. The developed analytic simulator in this study emulated the randomness of the detection process of a multiple-scattering Compton camera, including the inherent degradation factors of the detectors, such as the limited spatial and energy resolutions. The Doppler-broadening effect owing to the momentum distribution of electrons in Compton scattering was not considered in the detection process because most interested isotopes for biomedical and environmental applications have high energies that are less sensitive to Doppler broadening. The analytic simulator and image generator for MSCC can be utilized to determine the optimal geometrical parameters, such as the distances between detectors and detector size, thus affecting the imaging performance of the Compton camera prior to the development of a real system.

Convolutional Neural Network Based Multi-feature Fusion for Non-rigid 3D Model Retrieval

  • Zeng, Hui;Liu, Yanrong;Li, Siqi;Che, JianYong;Wang, Xiuqing
    • Journal of Information Processing Systems
    • /
    • 제14권1호
    • /
    • pp.176-190
    • /
    • 2018
  • This paper presents a novel convolutional neural network based multi-feature fusion learning method for non-rigid 3D model retrieval, which can investigate the useful discriminative information of the heat kernel signature (HKS) descriptor and the wave kernel signature (WKS) descriptor. At first, we compute the 2D shape distributions of the two kinds of descriptors to represent the 3D model and use them as the input to the networks. Then we construct two convolutional neural networks for the HKS distribution and the WKS distribution separately, and use the multi-feature fusion layer to connect them. The fusion layer not only can exploit more discriminative characteristics of the two descriptors, but also can complement the correlated information between the two kinds of descriptors. Furthermore, to further improve the performance of the description ability, the cross-connected layer is built to combine the low-level features with high-level features. Extensive experiments have validated the effectiveness of the designed multi-feature fusion learning method.

Imaging Plate에 기록된 전자회절자료의 해석 (Accurate Interpretation of Electron Diffraction Data Acquired by Imaging Plates)

  • 김영민;김윤중
    • Applied Microscopy
    • /
    • 제33권3호
    • /
    • pp.195-204
    • /
    • 2003
  • Imaging plate에 기록된 전자회절 자료의 면간 거리 분석과 상동정시 나타나는 오차 요인들을 고찰하고 실험적인 보정방법을 도출하였다. 각각의 회절방향에 대한 radial intensity distribution plot과 실험적으로 도출된 면간 거리 보정식에 의해 전자회절 자료의 디지털 이미지에서 면간 거리 측정오차는 약 0.5%로 낮아짐을 알 수 있었다. Al 표준시료를 이용하여 imaging plate에 기록된 전자회절 자료의 면간 거리 편차 경향을 분석한 후 [001] gibbsite 시편에 동일한 실험적 보정을 수행하여 120분간의 전자빔 조사로부터 형성된 여러 전이 상들에 대한 면간 거리 측정 및 상 동정을 보다 정밀히 수행할 수 있었다. 그 결과, gibbsite로부터 형성된 주요 전이상들은 ${\chi}$-알루미나, ${\gamma}$-알루미나, ${\sigma}$-알루미나로 구성됨을 명확하게 동정할 수 있었다.

Automated 3D scoring of fluorescence in situ hybridization (FISH) using a confocal whole slide imaging scanner

  • Ziv Frankenstein;Naohiro Uraoka;Umut Aypar;Ruth Aryeequaye;Mamta Rao;Meera Hameed;Yanming Zhang;Yukako Yagi
    • Applied Microscopy
    • /
    • 제51권
    • /
    • pp.4.1-4.12
    • /
    • 2021
  • Fluorescence in situ hybridization (FISH) is a technique to visualize specific DNA/RNA sequences within the cell nuclei and provide the presence, location and structural integrity of genes on chromosomes. A confocal Whole Slide Imaging (WSI) scanner technology has superior depth resolution compared to wide-field fluorescence imaging. Confocal WSI has the ability to perform serial optical sections with specimen imaging, which is critical for 3D tissue reconstruction for volumetric spatial analysis. The standard clinical manual scoring for FISH is labor-intensive, time-consuming and subjective. Application of multi-gene FISH analysis alongside 3D imaging, significantly increase the level of complexity required for an accurate 3D analysis. Therefore, the purpose of this study is to establish automated 3D FISH scoring for z-stack images from confocal WSI scanner. The algorithm and the application we developed, SHIMARIS PAFQ, successfully employs 3D calculations for clear individual cell nuclei segmentation, gene signals detection and distribution of break-apart probes signal patterns, including standard break-apart, and variant patterns due to truncation, and deletion, etc. The analysis was accurate and precise when compared with ground truth clinical manual counting and scoring reported in ten lymphoma and solid tumors cases. The algorithm and the application we developed, SHIMARIS PAFQ, is objective and more efficient than the conventional procedure. It enables the automated counting of more nuclei, precisely detecting additional abnormal signal variations in nuclei patterns and analyzes gigabyte multi-layer stacking imaging data of tissue samples from patients. Currently, we are developing a deep learning algorithm for automated tumor area detection to be integrated with SHIMARIS PAFQ.

평면 이미지 기법을 이용한 분무 특성 해석 (The Spray Characterization Using Planar Imaging Technique)

  • 이경진;정기훈;윤영빈;정경석;정인석
    • 대한기계학회논문집B
    • /
    • 제24권1호
    • /
    • pp.93-101
    • /
    • 2000
  • The characteristics of spray nozzle have been quantified with the measurement of fluorescence and Mie scattering images. To correct the attenuation of the incident light sheet, a sequential double-pass light sheet system and the geometrical averaging of two images was implemented. Quantitative mass flux distribution of spray was obtained from fluorescence image. 3-D image is reconstructed using 2-D radial images. Sauter mean diameter (SMD) distribution was determined using the ratio of fluorescence signal intensity and Mie scattering signal intensity and the values were quantified with PDP A data. The measurement of mass flux and SMD using planar imaging technique agee with PDP A data fairly well in the low density region. However, in dense region, there are significant errors caused by secondary scattering. It was found that the planar imaging technique provides many advantages over the point measurement technique, such as PDP A, and can be implemented for quantitative measurement, especially in low density region.

Crosstalk evaluation in multiview autostereoscopic three-dimensional displays with an optimized diaphragm applied

  • Peng, Yi-Fan;Li, Hai-Feng;Zheng, Zhen-Rong;Xia, Xin-Xing;Yao, Zhi;Liu, Xu
    • Journal of Information Display
    • /
    • 제13권2호
    • /
    • pp.83-89
    • /
    • 2012
  • The crosstalk evaluation of multiview autostereoscopic three-dimensional (3D) displays is discussed, with both the human and technical factors investigated via image quality assessment. In the imaging performance measurements and analysis for a multiview autostereoscopic display prototype equipment, it was inferred that crosstalk would have both a positive and a negative effect on the imaging performance of the equipment. The importance of the attached diaphragm in the crosstalk evaluation was proposed and then experimentally verified, using the developed prototype equipment. The luminance distribution and crosstalk situation were given, with two different diaphragm arrays applied. The analysis results showed that the imaging performance of this 3D display system can be improved with minimum changes to the system structure.

평면 이미지 기법에서 감쇠로 인한 측정 오차에 대한 연구 (Study on Measurement Errors due to Attenuation in Plannar Image technique)

  • 전재영;김동준;고현석;윤영빈
    • 한국분무공학회지
    • /
    • 제7권3호
    • /
    • pp.24-30
    • /
    • 2002
  • In the analysis of the mass distribution and SMD(Sauter Mean Diameter), planar laser imaging technique is a convenient and useful one when compared to the mechanical pattemator or PDPA (Phase Doppler Particle Analyzer). But recorded signals at cameras and intensity of laser are distorted by attenuation. Using experimental datum and assumptions, we study measurement errors due to attenuation in plannar image technique.

  • PDF

광자 계수 집적 영상 현미경을 사용한 마이크로 물체의 3차원 시각화와 인식 (Three-Dimensional Visualization and Recognition of Micro-objects using Photon Counting Integral Imaging Microscopy)

  • 조명진;조기옥;신동학
    • 한국정보통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.1207-1212
    • /
    • 2015
  • 본 논문에서는 광자 계수 집적 영상 현미경을 사용하여 광자가 희박한 조건에서 마이크로 물체의 3차원 시각화와 인식에 대한 기술을 제안한다. 제안하는 방법에서는 고해상도의 서로 다른 원근감을 가지는 2차원 영상을 획득하기 위해 합성조리개 집적 영상을 사용한다. 그리고 영상으로부터 광자를 추출하기 위해 광자계수 영상 시스템의 수학적 모델인 포아송 분포를 사용하며 통계적 추정법으로 부터 3차원 영상을 추정한다. 따라서, 광자가 희박한 조건에서 마이크로 물체가 손상되지 않으면서 그에 대한 3차원 영상을 획득하고 시각화할 수 있다. 추가적으로, 비선형 상관 필터를 사용하여 3차원 물체의 인식도 가능하다. 본 기술의 유용성을 증명하기 위해, 광학적 실험을 수행하였다.

방사능 측정장치 운영 기술 및 측정정보 통합관리 시스템 개발 (Development of Operational Technology and Integrated Measurement Information Management System for the Radioactivity Measurement Device)

  • 진동식;김경령;이재근
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권3호
    • /
    • pp.183-195
    • /
    • 2024
  • Additional functional upgrades to the large-area compton camera (LACC) measurement device that can provide characteristics evaluation information (nuclear species and radioactivity) and two-dimensional or three-dimensional distribution imaging information of radioactive materials existing in surface or internal of concrete structures are required in terms of work stability and efficiency in order to apply to actual decommissioning sites such as nuclear power plants or medical cyclotron facilities by using this measurement device. To this purpose, the technology that allows radiation workers to intuitively and visually check the distribution of radioactive materials in advance by matching the two-dimensional distribution imaging information of radioactive materials obtained through the LACC measurement device and visual imaging of the measurement zone (10 m × 5 m) was developed. In addition, the separate system that can automatically adjust the position (height) in units of the measurement area size (0.7 m × 0.3 m × 0.8 m) of the LACC measurement device was developed and the integrated management system for characteristics evaluation information and two-dimensional or three-dimensional distribution imaging information obtained per unit of measurement for radioactive materials was developed. These functional upgrades related to LACC measurement device can improve work efficiency and safety when measuring radioactivity of concrete structures and enable the establishment of appropriate decommissioning strategies using radioactivity measurement information for decommissioning nuclear power plants or medical cyclotron facilities.