• 제목/요약/키워드: 3D body scanner

검색결과 100건 처리시간 0.022초

인체측정용 3차원 스캐너 제작 (Development of Three Dimensional Scanner for Anthropometric Measurement)

  • 김민효;남윤자
    • 대한인간공학회지
    • /
    • 제20권3호
    • /
    • pp.77-88
    • /
    • 2001
  • A three dimensional body scanner for anthropomentric measurement has been developed. In this study, the slit laser beam projection method followed by digital image processing was used to provide accurate spatial data with the typical optical triangulation method to overcome the many difficulties in traditional in accurate and time-consuming tactic measurement method using rulers and gauges. Compared with other commercialized scanners. this system can obtain a relatively wide range of data at a much lower cost by the specially designed scanning process such as the simultaneous acquisition of vertical and horizontal body cross-section profiles.

  • PDF

Changes in Back Body Surface Measurements for Dynamic Postures in the Form of Baseball Batting Motion with a 3D body Scanning

  • Shin, Saemi;Chun, Jongsuk
    • International Journal of Human Ecology
    • /
    • 제14권1호
    • /
    • pp.41-55
    • /
    • 2013
  • The purpose of this study was to analyze human upper body surface changes at the shoulder and back area. The body surface data were analyzed in terms of muscle and bone displacement in dynamic postures. Body surface data were collected with a 3D body scanner. The body surface was scanned at the static and four baseball batting postures. The body surface dimensions over the deltoids, scapulae and trapezius were measured. The results show that the vertical measurements of the deltoids increased by 20%. The horizontal measurements of the axilla of the back increased. The surface of the trapezius was elongated by over 10%, and the lower back musculature was elongated by about 50%. The results of this study showed that changes in back body surface caused by upper arm movements. It was influenced by the deltoid articulated with the humeri and the scapulae and trapezius. These body surface changes caused by muscle activities and ranges of motion can be used to design functional clothing.

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations

  • Bi, Chuang;Wang, Xingyu;Tian, Fangfang;Qu, Zhe;Zhao, Jiaming
    • The Journal of Advanced Prosthodontics
    • /
    • 제14권4호
    • /
    • pp.236-249
    • /
    • 2022
  • PURPOSE. The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS. The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS. Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION. For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.

중국 성인여성의 직접계측과 3D Body scanning 치수 비교 연구 (Comparison of Size between direct-measurement and 3D body scanning)

  • 차수정
    • 패션비즈니스
    • /
    • 제16권1호
    • /
    • pp.150-159
    • /
    • 2012
  • This study intend to analyze differences between 3D body scanning sizes and direct measurement sizes of same subjects. The subjects of study are female students of university in China. 3D data analyze as a 3D Body Measurement Soft System. The conclusion found is as below: In case of circumferences, error between direct-measurement size and 3D body scanning size is from 4.9mm to 62.2mm. The neck circumference size of directmeasurement is bigger than 3D body scanning size. The height error range is from 0.6mm to 51mm. Height of underbust, waist and hip are that direct-measurement sizes are higher than 3D body scanning sizes. Gap of width is from 3.8mm to 21.9mm. The gap range is too narrow relatively to others. Only direct-measurement size of neck width is wider than 3D body scanning size. Error range of length is from 0.3mm to 41.8mm. 3D body scanning sizes of lateral neck to waistline, upperarm length, arm length, neck shoulder point to breast point, shoulder center point to breast point, lateral shoulder to breast point are longer than direct-measurement sizes. They have a negative margin of error. I intend to set up same measurement point between direct-measurement and 3D body scanning but they have some errors because direct-measurement point is applied by a person. 3D body scanning measurement point is settled by automatic system. A measurement point of direct-measurement and 3D body scanning isn't unite. So we need to make a standard of setting up measurement points.

클라우드 기반 인체측정 데이터 모니터링 시스템 (Cloud-based anthropometric data monitoring system)

  • 전성우;한혜동;김정은;정회경
    • 한국정보통신학회논문지
    • /
    • 제24권9호
    • /
    • pp.1209-1214
    • /
    • 2020
  • 최근 고령화 시대가 되면서 사람들의 건강한 삶에 관한 관심이 높아지고 있다. 사람들은 잘못된 생활, 식습관, 신체활동 저하 등으로 인하여 성인병을 유발하거나 비만 인구수가 증가하고 있다. 이에 정보통신 분야에서 의료분야 정보를 활용하여 피부 미용 연구가 진행되고 있다. 기존의 시스템들은 다양한 관련 측정 항목들에 대해 결합하여 표현되지 않아서 원활한 정보를 제공받지 못하였다. 본 논문에서 제안하는 시스템은 3D 스캐너와 피부미용기기를 사용하여 사용자의 체형을 스캔하고, 3D 이미지 데이터를 사용하여 BMI(Body Mass Index) 지수를 계산하고 수집된 데이터를 한눈에 볼 수 있는 웹 서비스 시스템을 제공한다. 이는 지속적인 신체 변화 데이터를 비교하여 제공하므로 관리되는 내용을 사용자에게 제공하게 될 것이다. 이는 다양한 U-헬스 및 미용분야에서 널리 활용될 것으로 사료된다.

노년 여성 체형의 표준화된 3차원 측정 데이터 추출을 위한 기초 연구 (A Basic Study Contributes to Extract the Standardized 3D Body Data for Women Aged 60 and Older)

  • 이정임;주소령
    • 한국의류학회지
    • /
    • 제28권2호
    • /
    • pp.344-353
    • /
    • 2004
  • The purpose of this study was to offer the basis contributes to extract the standardized body data from 3D body measuring for women aged 60 and older. The WB4 of Cyberware was used, and the measuring program of 3D scanning data was 3DM. This study was focused to verify the reliability of 3D data and to offer the effective utilization of 3D measuring on the research for elderly women■s body. Subjects were 19 women aged 60 and older. And three women in late twenties and three dressforms for women were comparing subjects to analyze the signiscant difference by age or human body variable making error. First, 3D scanning was executed twice on each subject, but any significant difference was not appear between two scanning data. So we certifed we could get the consistent and reliable data from the 3D scanner used in this study. Second, the reliability of 3D measuring data was analyzed, and the error range which meant the difference between 3D data and traditional measuring data was analyzed. In elderly women, the significant difference between two data was appeared in 19 body parts. The 7 of 19 were concerned with armpit point. In young women, three significant difference were appeared, and in dressforms, any significant difference was not certified. From these results, we could certify that age or human body variable produced the difference between two data. Third, the data of elderly women from three measuring methods, 3D measuring, traditional measuring, and measuring on 2D photographs were compared. From the result, we found that the 3D measuring data was quite reliable for most body parts excluding some width parts. But in elderly women, there were some limitation to extract reliable data because of their unique body characteristics. In order to be a role of the effective measuring method, the 3D measuring protocol reflected the body characteristics of each age or gender had to be prepared.

3차원 스캐너를 이용한 20대 남성의 하반신 신축량 분석 (A study of the variations by motion of the Lower body Using 3D Body Surface Scan Data of a man in his early twenties)

  • 손부현;홍경희
    • 한국생활과학회지
    • /
    • 제18권3호
    • /
    • pp.729-740
    • /
    • 2009
  • This study is to research on the rate of expansion or contraction according to movement of the lower body of the man their twenties using Rapid Form software. And aim of this study is to get information of ease allowance in developing slacks pattern using 3D body surface scan data through comparison with existing slacks patterns. Considering on the contraction and expansion according to movement, it need to set the more ease allowance in hip circumference than waist circumference, and the more ease allowance in back hip width than front hip width in slacks. In crotch length, the length of front crotch is revealed contraction but the length of back crotch is revealed expansion. It is desirable lowering front waist line and raising back waist line to possess ease allowance in back crotch area. The length of side seam is revealed a little expansion but the length of inseam is showed a great expansion. To develop slacks pattern of scientific approach using 3D body surface scan data, it need to analysis the rate of expansion and contraction of the lower body based on the movement, shear deformation, slip in fabrics and skin, or in fabrics and fabrics, and slip down from waist line.

3차원 자동체형계측기 정밀도 검사 (An Accuracy Analysis of the 3D Automatic Body Measuring Machine)

  • 전수형;권석동;박세정;김정양;송정훈;김현진;김종원
    • 사상체질의학회지
    • /
    • 제20권1호
    • /
    • pp.42-47
    • /
    • 2008
  • 1. Objectives The Body Shape and Feature is one of the important standard for classification of Sasang Constitutions. In order to evaluate one's Body Shape and Feature objectively we have been developing the Body Measuring Machine. Now we develop the 3D Automatic Body Measuring Machine(3D-ABMM). So we make an analysis of the 3D-ABMM's Accuracy. 2. Methods By using the 3D-ABMM and Vivid 9i(3D laser scanner, Konica Minolta) we have a surface scan of the three objects which are the upper body of the female and male Manikin and a male model. We overlap each scan data using the RapidForm2006 (3D scan data solution, INUS Technology) and calculate the average distance and standard deviation between the same point of each scan data. 3. Results and Conclusions In the female Manikin, the average distance is 0.84mm and the standard deviation is 1.16mm and the maximum distance is 10.68mm. In the male Manikin, the average distance is 1.12mm and the standard deviation is 1.19mm and the maximum distance is 12.00mm. In the male model, the average distance is 3.26mm and the standard deviation is 2.59mm and the maximum distance is 12.75mm. From the results, 3D-ABMM has good accuracy for scanning body and will be a usable hardware of the 3D Automatic Body Analysis Machine.

  • PDF

팔 동작에 따른 소매유무별 블라우스 착의형상의 3차원적 파악 (A Study on the Dressed Shapes of the Blouse with Short Sleeves and Sleeveless according to Arm Movement Using 3-D Scanner)

  • 이명희
    • 한국의류산업학회지
    • /
    • 제8권2호
    • /
    • pp.209-213
    • /
    • 2006
  • The 3-D information is useful as basic data which has been utilized in the development of simulating technology as fit-simulation. The experiment is designed to take some useful data on the variant shapes which contribute in simulating the adaptability of the clothes. The general figure of the clothes are made after the figure of the basic standing posture of the human body. The shape of the clothes fits with kinetic characteristic of the human body as the form of the clothes gets twisted, the ease of the clothes changes, and the clothes itself expands. We studied the dressed shapes of blouse according to two types of the arm movement(basic posture and reach forward) and three types of clothes(foundation, blouse with short sleeves and sleeveless) in the sit-down-posture. We accomplished some experimental data on three-dimensional measurement of the dressing shapes using TDS-3100 3-D scanner made in Japan PULSTECH. It is considered that the variant of shapes and distribution of gaps in the dressed shapes of blouse are determined by the adaptability of clothes made in arm movement.