• Title/Summary/Keyword: 3D beam

Search Result 1,681, Processing Time 0.028 seconds

3-D Beam Steering Antenna for Intelligent Beam-reconfigurable System (지능형 빔 재구성 시스템을 위한 3-D 빔 조향 안테나)

  • Lee, Chang Yong;Kim, Yong-Jin;Jung, Chang Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.10
    • /
    • pp.4773-4779
    • /
    • 2012
  • In this paper we propose two types of reconfigurable 3-D beam steering antenna for intelligent or smart antenna system. Proposed antennas are composed of triangular(structure1.) or circuler(structure2.) loop structure and bended dipole antenna structure. This antenna can steer beam pattern of 6 direction at xy-plane state (0, 1, 2) and xz-plane state (3, 4, 5) by 4 switch motion with one antenna element. Antenna structure1. is symmetric equilibrium structures based on feeding point. There is no grounding point. As a result, designed antenna's gain is similar to dipole antenna. Also, As unbalanced structure by using CPWG in the form of a semicircular, structure2. is enhanced directivity. The operation frequency of antenna are 2.5 GHz(Structure1.) and 2.55 GHz(Structure2.), maximum gain is 1.04 ~ 2.06 dBi(Structure1. : Omni-directional beam), 1.6 ~ 4 dBi(structure2. : Directional beam). The overall HPBW is about over $160^{\circ}$ in the both of the xy-plane and xz-plane at structure1. and over $125^{\circ}$ at structure2.

Evaluation of DVH and NTCP in Hepatoma for 3D Conformal Radiation Therapy (3차원 입체조형치료에 대한 간암의 선량분포와 정상조직손상확률의 평가)

  • Chung, Kap-Soo;Yang, Han-Joon;Ko, Shin-Gwan
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.79-82
    • /
    • 1997
  • Image-based three dimensional radiation treatment planning(3D RTP) has a potential of generating superior treatment plans. Advances in computer technology and software developments quickly make 3D RTP a feasible choice for routine clinical use. However, it has become clear that an evaluation of a 3D plan is more difficult than a 2D plan. A number of tools have been developed to facilitate the evaluation of 3D RTP both qualitatively and quantitatively. For example, beam's eye view(BEV) is one of the most powerful and time-saving method as a qualitative tools. Dose-volume histogram(DVH) has been proven to be one of the most valuable methods for a quantitative tools. But it has a limitation to evaluate several different plans for biological effects of the tissue and critical organ. Therefore, there is a strong interest in developing quantitative models which would predict the likely biological response of irradiated organs and tissues, such as tumor control probability(TCP) and normal tissue complication probability(NTCP). DVH and NTCP of hepatoma were evaluated for three dimensional conformal radiotherapy(3D CRT). Also, 3D RTP was analysed as a dose optimization based on beam arrangement and beam modulation.

  • PDF

Method for Supplementing Single-View Resolution of Multiview Autostereoscopic Three-Dimensional Display Using Plate Beam Splitter

  • Kim, Hyun-Woo;Cho, Myungjin;Lee, Min-Chul
    • Journal of information and communication convergence engineering
    • /
    • v.19 no.2
    • /
    • pp.108-113
    • /
    • 2021
  • Multiview autostereoscopic three-dimensional (MA3D) displays have the disadvantage that the single-view resolution decreases as the number of views increases. Furthermore, the resolution of MA3D displays is relatively degraded, even though the resolution of two-dimensional displays has increased recently. Therefore, it is unattractive to consumers, and the single-view resolution enhancement of MA3D displays is required. In this study, we developed a method for supplementing the single-view resolution of MA3D displays using a plate beam splitter that can show two MA3D displays simultaneously. By applying our proposed method, the resolution of a single view can increase, and the visual obstruction by the optical plate, which is a problem for MA3D displays, can be solved. In addition, an MA3D display was optically designed and fabricated using a parallax barrier. Finally, the experimental optical results obtained using the proposed method and the only MA3D display were compared.

Transient response of 2D functionally graded beam structure

  • Eltaher, Mohamed A.;Akbas, Seref D.
    • Structural Engineering and Mechanics
    • /
    • v.75 no.3
    • /
    • pp.357-367
    • /
    • 2020
  • The objective of this article is investigation of dynamic response of thick multilayer functionally graded (FG) beam under generalized dynamic forces. The plane stress problem is exploited to describe the constitutive equation of thick FG beam to get realistic and accurate response. Applied dynamic forces are assumed to be sinusoidal harmonic, sinusoidal pulse or triangle in time domain and point load. Equations of motion of deep FG beam are derived based on the Hamilton principle from kinematic relations and constitutive equations of plane stress problem. The numerical finite element procedure is adopted to discretize the space domain of structure and transform partial differential equations of motion to ordinary differential equations in time domain. Numerical time integration method is used to solve the system of equations in time domain and find the time responses. Numerical parametric studies are performed to illustrate effects of force type, graduation parameter, geometrical and stacking sequence of layers on the time response of deep multilayer FG beams.

One-Dimensional Beam Modeling of a Composite Rotor Blade (복합재 블레이드의 1차원 보 모델링)

  • Lee, Min-Woo;Bae, Jae-Sung;Lee, Soo-Yong;Lee, Seok-Joon;Jeon, Boo-Il
    • Journal of Aerospace System Engineering
    • /
    • v.2 no.1
    • /
    • pp.7-12
    • /
    • 2008
  • The three-dimensional finite element modeling of a composite rotor blade is very hard and requires much computation effort. The efficient method to model a composite beam is necessary for the dynamic and aeroelastic analyses of rotor blades. In this study, the beam modeling method of a composite rotor blade is studied using VABS. The computer program, VABS (Variational Asymptotic Beam Section Analysis), uses the variational asymptotic method to split a 3-D nonlinear elasticity problem into 2-D cross-sectional analysis and 1-D nonlinear beam problem. The VABS can produce the sectional stiffness coefficients of composite rotor blades with various cross section and initial twist/curvatures, and recover the original 3-D distribution of displacement/strain/stress fields. The results of various cross section beams show that VABS gives us the accurate results comparared to commercial codes and does not need much computation effort. It can be concluded that VABS provides the efficient method to establish the FE model of a composite rotor blade.

  • PDF

Study on terrestrial LIDAR transmitter designed to improve accuracy (측량용 레이저 스캐너의 정밀도 개선을 위한 송신부설계)

  • Yoo, Hyun-Kuk;Jeong, Jung-Yeon;Oh, Dong-Geun;Kim, Jae-Soon
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2009.04a
    • /
    • pp.41-48
    • /
    • 2009
  • Laser diode is used as a crucial part for minimization of terrestrial 3D Laser Scanner. But it has certain limitations such as oval beam shape and inevitable astigmatism. In order to realize a parallel light with beam divergence below 1 mrad, These problems of laser diode can be solved through beam shaping by Pinhole and Aperture. Finally, this study could materialize a collimated beam with 0.3 mrad beam divergence angle and 3mm diameter, that performance and checked by using real manufacture.

  • PDF

A Study on the Structural Analysis of Curved Portions of Pipe Loops Used in Ships (선박용 파이프 루프 곡선부의 구조해석에 관한 연구)

  • Park, Chi-Mo;Bae, Byoung-Il
    • Journal of Ocean Engineering and Technology
    • /
    • v.24 no.5
    • /
    • pp.88-93
    • /
    • 2010
  • Many pipes that are arranged longitudinally in ships have loops at intervals to prevent the failure of the pipes as they absorb large portions of the axial load caused by the bending of the hull girder and/or thermal loads when the pipes are carrying very hot fluids. Since the loops are curved at corners, an efficient method for conducting the structural analyses of these curved portions is required. In this paper, a pipe loop was analyzed by an analytical method and by the finite-element method in four different ways, i.e., based on straight-beam elements, curved-beam elements, 2-D shell elements, and 3-D solid elements. The results of the five analyses were compared to check the validity of the current curved-beam theory. The paper includes some suggestions on how to analyze the pipe loops efficiently.

Global hydroelastic analysis of ultra large container ships by improved beam structural model

  • Senjanovic, Ivo;Vladimir, Nikola;Tomic, Marko;Hadzic, Neven;Malenica, Sime
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.6 no.4
    • /
    • pp.1041-1063
    • /
    • 2014
  • Some results on the hydroelasticity of ultra large container ships related to the beam structural model and restoring stiffness achieved within EU FP7 Project TULCS are summarized. An advanced thin-walled girder theory based on the modified Timoshenko beam theory for flexural vibrations with analogical extension to the torsional problem, is used for formulation of the beam finite element for analysis of coupled horizontal and torsional ship hull vibrations. Special attention is paid to the contribution of transverse bulkheads to the open hull stiffness, as well as to the reduced stiffness of the relatively short engine room structure. In addition two definitions of the restoring stiffness are considered: consistent one, which includes hydrostatic and gravity properties, and unified one with geometric stiffness as structural contribution via calm water stress field. Both formulations are worked out by employing the finite element concept. Complete hydroelastic response of a ULCS is performed by coupling 1D structural model and 3D hydrodynamic model as well as for 3D structural and 3D hydrodynamic model. Also, fatigue of structural elements exposed to high stress concentration is considered.

Development of 3D Woven Preform π-beam based on T-beam Made of Laminated Composites (적층복합재료 T-빔 기반의 3차원 직조 프리폼 π-빔 개발)

  • Park, Geon-Tae;Lee, Dong-Woo;Byun, Joon-hyung;Song, Jung-il
    • Composites Research
    • /
    • v.33 no.3
    • /
    • pp.115-124
    • /
    • 2020
  • Laminate composites, especially Carbon fiber-reinforced composites are wide used in various industry such as aerospace and automotive industry due to their high specific strength and specific stiffness. However, the laminate composites has a big disadvantage that delamination occurs because the arrangement of the fibers is all arranged in the in-plane direction, which limits the field of application of the laminate composites. In this study, we first developed a laminate composites T-beam in which π-beam and flat plate were combined and optimized the design parameters through structural analysis and mechanical tests. Afterwards, 3D weave preform T-beam was developed by applying the same design parameters of laminate composites T-beams, and improved mechanical strength was achieved compared to laminated structures. These findings are expected to be applicable to existing laminated composite structures that require increased strength.

The accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing (골결손부 치유과정에서 cone beam형 전산화단층영상의 정확도)

  • Kang, Ho-Duk;Kim, Gyu-Tae;Choi, Yong-Suk;Hwang, Eui-Hwan
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.69-77
    • /
    • 2007
  • Purpose: To evaluate the accuracy of the imaging reformation of cone beam computed tomography for the assessment of bone defect healing in rat model. Materials and Methods: Sprague-Dawley strain rats weighing about 350 gms were selected. Then critical size bone defects were done at parietal bone with implantation of collagen sponge. The rats were divided into seven groups of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 6 weeks, and 8 weeks. The healing of surgical defect was assessed by multi planar reconstruction (MPR) images and three-dimensional (3-D) images of cone beam computed tomography, compared with soft X-ray radiograph and histopathologic examination. Results: MPR images and 3-D images showed similar reformation of the healing amount at 3 days, 1 week, 2 weeks, and 8 weeks, however, lower reformation at 3 weeks, 4 weeks, and 6 weeks. According to imaging-based methodologies, MPR image revealed similar reformation of the healing amount than 3-D images compare with soft X-ray image. Among the four threshold values for 3-D images, 400-500 HU revealed similar reformation of the healing amount. Histopathologic examination confirmed the newly formed trabeculation correspond with imaging-based methologies. Conclusion: MPR images revealed higher accuracy of the imaging reformation of cone beam computed tomography and cone beam computed tomography is a clinically useful diagnostic tool for the assessment of bone defect healing.

  • PDF