• Title/Summary/Keyword: 3D X-ray CT

Search Result 150, Processing Time 0.027 seconds

Relationship between trabecular strength and three-dimensional architecture in the pig mandible using microcomputed tomography (돼지 하악골의 micro-CT영상에서 추출한 3차원 골미세구조와 골강도 사이의 상관관계)

  • Huh Kyung-Hoe;Park Moo-Soon;Yi Won-Jin;Heo Min-Suk;Lee Sam-Sun;Choi Soon-Chul
    • Imaging Science in Dentistry
    • /
    • v.35 no.3
    • /
    • pp.167-173
    • /
    • 2005
  • Purpose : To investigate the relationship between three-dimensional (3D) bone imaging parameters and trabecular strength in the mandible. Materials and Methods : Bone specimens were obtained from the mandibles of five male pigs weighing around 110 kg each. Of those, 43 samples were selected for 3D analysis and measured by micro-computed tomography. The five morphometric parameters were trabecular thickness (Tb.Th), bone specific surface (BS/BV), percent bone volume (BV/TV), structure model index (SMI) and degree of anisotropy (DA). Through destructive mechanical testing, strength parameters were obtained. Results : BV/TV, SMI, BS/BV, and Tb.Th showed significant correlations with strength parameters. DA did not show any correlation with the other parameters. In multiple linear regression analysis, BV/TV alone explained $43\%$ of the variance in Young's modulus. By stepwise inclusion of SMI, the variance in the Young's modulus was better explained up to $52\%$. Conclusions : Predicting trabecular strength in the mandible through architectural analysis would be possible. Further study is needed to establish the tendency and variety of trabecular architecture and strength according to the locations within the mandible.

  • PDF

Evaluation of Micro-defects and Air Tightness of Al Die-casting by Impregnation of Organic Solvent (유기용제 함침법을 통한 알루미늄 다이캐스팅의 미세결함 및 기밀성 평가)

  • Lee, Jin-Wook;Cho, Chang-hyun;Kim, Sung-Gye;Ko, Young-Gun;Kim, Dong-Ju
    • Journal of Korea Foundry Society
    • /
    • v.42 no.4
    • /
    • pp.218-225
    • /
    • 2022
  • For hydrogen-vehicle applications (air pressure control valve housing, APCVH), an investigation was conducted to determine how micro-defects in a high- pressure die-casted Al alloy (industrial code: ALDC12) could be controlled by means of a post-treatment using an organic-based impregnation solution in order to improve the air- tightness of the die-casted Al sample. Two different impregnation solutions were proposed and its test results were compared to a imported product from Japan with respect to the processing variables used. A structural investigation of the components under study was conducted by means of computer tomography and 3D X-ray micro-CT. These observations revealed that the use of the impregnation treatment to seal micro-defects led to highly significant and beneficial changes which were attributed mainly to interconnections among inherent micro-pores. A leak test after impregnation revealed that the performance improvement rate of the die-casted Al sample was ~70% for INNO-01. Therefore, the developed impregnation solutions offer an effective strategy to control the micro-defects found in various vehicle parts via die-casting.

Improved shape-based interpolation for three-dimensional reconstruction in gray-scale images (3차원 그레이-스케일 영상 재구성을 위한 개선된 형태-기반 보간)

  • Kim Hong, Helen;Park, Joo-Young;Kim, Myoung-Hee
    • Journal of the Korea Computer Graphics Society
    • /
    • v.2 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Using a series of medical tomograms, we can reconstruct internal organs or other objects of interest and generate 3-D images. It is generally accepted that the axial resolution determined by two sequential image slices is lower than the planar resolution in one image slices. Therefore, various methods of interpolation were developed for an accurate display of reconstructed images. In this paper, a new algorithm for 3-D reconstruction of the medical images such as MRI and X-ray CT is suggested. The algorithm is shape-based and utilizes parts of the gray-level information. We extend the conventional shape-based interpolation of the binary images to the gray-scale images using the shortest distance map. Using this new algorithm, We could reduce the execution time for interpolation while keeping similar high quality of the reconstructed images with reduced execution time and is applicable to the various medical tomograms.

  • PDF

Measurement of facial soft tissues thickness using 3D computed tomographic images (3차원 전산화단층찰영 영상을 이용한 얼굴 연조직 두께 계측)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Shin Dong-Won;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.1
    • /
    • pp.49-54
    • /
    • 2006
  • Purpose : To evaluate accuracy and reliability of program to measure facial soft tissue thickness using 3D computed tomographic images by comparing with direct measurement. Materials and Methods : One cadaver was scanned with a Helical CT with 3 mm slice thickness and 3 mm/sec table speed. The acquired data was reconstructed with 1.5 mm reconstruction interval and the images were transferred to a personal computer. The facial soft tissue thickness were measured using a program developed newly in 3D image. For direct measurement, the cadaver was cut with a bone cutter and then a ruler was placed above the cut side. The procedure was followed by taking pictures of the facial soft tissues with a high-resolution digital camera. Then the measurements were done in the photographic images and repeated for ten times. A repeated measure analysis of variance was adopted to compare and analyze the measurements resulting from the two different methods. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant differences between the direct measurements and those using the 3D images (p>0.05). There were statistical differences in the measurements on 17 points but all the points except 2 points showed a mean difference of 0.5 mm or less. Conclusion : The developed software program to measure the facial soft tissue thickness using 3D images was so accurate that it allows to measure facial soft tissues thickness more easily in forensic science and anthropology.

  • PDF

Clinical usefulness of facial soft tissues thickness measurement using 3D computed tomographic images (3차원 전산화단층촬영 영상을 이용한 안면 연조직 두께 계측의 임상적 유용성)

  • Jeong Ho-Gul;Kim Kee-Deog;Han Seung-Ho;Hu Kyung-Seok;Lee Jae-Bum;Park Hyok;Choi Seong-Ho;Kim Chong-Kwan;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.36 no.2
    • /
    • pp.89-94
    • /
    • 2006
  • Purpose : To evaluate clinical usefulness of facial soft tissue thickness measurement using 3D computed tomographic images. Materials and Methods : One cadaver that had sound facial soft tissues was chosen for the study. The cadaver was scanned with a Helical CT under following scanning protocols about slice thickness and table speed; 3 mm and 3 mm/sec, 5 mm and 5 mm/sec, 7 mm and 7 mm/sec. The acquired data were reconstructed 1.5, 2.5, 3.5 mm reconstruction interval respectively and the images were transferred to a personal computer. Using a program developed to measure facial soft tissue thickness in 3D image, the facial soft tissue thickness was measured. After the ten-time repeation of the measurement for ten times, repeated measure analysis of variance (ANOVA) was adopted to compare and analyze the measurements using the three scanning protocols. Comparison according to the areas was analyzed by Mann-Whitney test. Results : There were no statistically significant intraobserver differences in the measurements of the facial soft tissue thickness using the three scanning protocols (p>0.05). There were no statistically significant differences between measurements in the 3 mm slice thickness and those in the 5 mm, 7 mm slice thickness (p>0.05). There were statistical differences in the 14 of the total 30 measured points in the 5 mm slice thickness and 22 in the 7 mm slice thickness. Conclusion : The facial soft tissue thickness measurement using 3D images of 7 mm slice thickness is acceptable clinically, but those of 5 mm slice thickness is recommended for the more accurate measurement.

  • PDF

The relationship between dental implant stability and trabecular bone structure using cone-beam computed tomography

  • Kang, Se-Ryong;Bok, Sung-Chul;Choi, Soon-Chul;Lee, Sam-Sun;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.46 no.2
    • /
    • pp.116-127
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the relationships between primary implant stability as measured by impact response frequency and the structural parameters of trabecular bone using cone-beam computed tomography(CBCT), excluding the effect of cortical bone thickness. Methods: We measured the impact response of a dental implant placed into swine bone specimens composed of only trabecular bone without the cortical bone layer using an inductive sensor. The peak frequency of the impact response spectrum was determined as an implant stability criterion (SPF). The 3D microstructural parameters were calculated from CT images of the bone specimens obtained using both micro-CT and CBCT. Results: SPF had significant positive correlations with trabecular bone structural parameters (BV/TV, BV, BS, BSD, Tb.Th, Tb.N, FD, and BS/BV) (P<0.01) while SPF demonstrated significant negative correlations with other microstructural parameters (Tb.Sp, Tb.Pf, and SMI) using micro-CT and CBCT (P<0.01). Conclusions: There was an increase in implant stability prediction by combining BV/TV and SMI in the stepwise forward regression analysis. Bone with high volume density and low surface density shows high implant stability. Well-connected thick bone with small marrow spaces also shows high implant stability. The combination of bone density and architectural parameters measured using CBCT can predict the implant stability more accurately than the density alone in clinical diagnoses.

The electronic structure of the ion-beam-mixed Pt-Cu alloys by XPS and XANES

  • Lim, K.Y.;Lee, Y.S.;Chung, Y.D.;Lee, K.M.;Jeon, Y.;Whang, C.N.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 1998.02a
    • /
    • pp.133-133
    • /
    • 1998
  • In the thin film alloy formation of the transition metals ion-beam-mixing technique forms a metastable structure which cannot be found in the arc-melted metal alloys. Sppecifically it is well known that the studies about the electronic structure of ion-beam-mixed alloys pprovide the useful information in understanding the metastable structures in the metal alloy. We studied the electronic change in the ion-beam-mixed ppt-Ct alloys by XppS and XANES. These analysis tools pprovide us information about the charge transfer in the valence band of intermetallic bonding. The multi-layered films were depposited on the SiO2 substrate by the sequential electron beam evapporation at a ppressure of less than 5$\times$10-7 Torr. These compprise of 4 ppairs of ppt and Cu layers where thicknesses of each layer were varied in order to change the alloy compposition. Ion-beam-mixing pprocess was carried out with 80 keV Ae+ ions with a dose of $1.5\times$ 1016 Ar+/cm2 at room tempperature. The core and valence level energy shift in these system were investigated by x-ray pphotoelectron sppectroscoppy(XppS) pphotoelectrons were excited by monochromatized Al K a(1486.6 eV) The ppass energy of the hemisppherical analyzer was 23.5 eV. Core-level binding energies were calibrated with the Fermi level edge. ppt L3-edge and Cu K-edge XANES sppectra were measured with the flourescence mode detector at the 3C1 beam line of the ppLS (ppohang light source). By using the change of White line(WL) area of the each metal sites and the core level shift we can obtain the information about the electrons pparticippating in the intermetallic bonding of the ion-beam-mixed alloys.

  • PDF

A Case Report of Treatment of Heterotrophic Calcification in Pseudohypoparathyroidism (가성 부갑상선 기능저하증의 이형 석회화 치험례)

  • Yoon, Sung-Won;Song, Jea-Yong;Kim, Chung-Hun
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.281-284
    • /
    • 2010
  • Purpose: Pseudohypoparathyroidism is a hereditary disorder characterized by symptoms and signs of hypoparathyroidism, typically in association with distinctive skeletal and developmental defects. Hypoparathyroidism is caused by a insufficient end-organ response to PTH (parathyroid hormone). Hypoparathyroidism consists of four types in which the most common form, pseudohypoparathyroidism-Ia, accompany with Albright's hereditary osteodystrophy. We experienced a case of a woman who had been suffering from calcified mass on left foot, diagnosed Albright's hereditary osteodystrophy. Methods: We present a case of a 24-year-old Korean female who visited plastic surgery department with a painful mass on dorsum of the left foot. On the physical exam, bony hard and painful mass, fixed to dermis, was noted. Plain X-ray films demonstrate suspicious calcification on subcutaneous tissue of dorsum of the left foot. The patient was diagnosed pseudohypoparathyroidism 2 years ago at the plastic surgery department. At the visiting time, the laboratory results were within normal range even though the patient actually had a disease. The reason is because the patient has been treated with Vit.D, calcium replacement therapy and thyroid hormone therapy. Moreover, the patient has been treated with anticonvulsant agents due to epilepsy. On the brain computer tomography (CT), calcification was noted on the basal ganglia and dentate nucleus. So we decided the total excision of entire mass from the left foot. Results: We excised main mass with numerous pinhead sized masses which were scattered around the main mass. The $6.0{\times}4.0{\times}0.5\;cm$ sized main mass was bony hard, and its surface was flat and margin was irregular. The permanent biopsy was confirmed that the main mass and all the scattered tiny masses were heterotopic calcification. The patient did not suffer from the pain after the mass excision. The wound has been healed without any problem. Conclusions: Heterotrophic calcification is often accompanied with pseudohypoparathyroidism, but such a huge one is uncommon. We report a case of pseudohypoparathyroidism with heterotrophic calcification developed in dorsum of left foot who was diagnosed by excisional biopsy.

Production and Assessing Usefulness of the Moving Phantom for Respiration Gated Radiotherapy (호흡동조 방사선치료용 팬텀의 제작 및 유용성 평가)

  • Lee, Yang-Hoon;Lee, Jae-Hee;Yoo, Suk-Hyun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.22 no.2
    • /
    • pp.135-144
    • /
    • 2010
  • Purpose: The purpose of this study is that through production of phantom for respiration gated radiotherapy, assessing appropriacy of exposure dose for the therapy using RPM (Real-time Position Management). Materials and Methods: We located measurement object on the phantom for respiration gated radiotherapy made of 2 linear actuator, acrylic panel, stanchion, iron plate ets. to drive (up, down, front, back). Using 4D CT scan, we analyzed patient's respiration and reproduced the movement by computer. On the phantom, we located a 2D-Array (PTW) and an White water phantom (4.5 cm) and used DMLC (interval 2 cm) in the field size $10{\times}10\;cm$, then exposed 21EX X-ray 100 MU, in the case of phantom was (1) static (2) moving (3) gated using RPM respectively gantry $0^{\circ}$ and $90^{\circ}$ We measured with a 0.125 CC ionization chamber (PTW) on the phantom (7.5 cm) in the same condition. Results: Ionization chamber: There were within 0.3% of error with gating respiration and approximately 2% of error without gating in the same condition. 2D-Array: Gantry $90^{\circ}$, field size $10{\times}10\;cm$, using DMLC. There were within 3% of error with gating respiration and approximately 16% of error without gating. Conclusion: The phantom for respiration gated radiotherapy makes plans considering patient's movement, quantitative analysis of exposure dose and proper assessment therapy for IMRT patients using RPM possible.

  • PDF

A Study of Dose Stability at Low Monitor Unit Setting for Multiple Irradiated Field (다중 조사면 치료 시 기계적 입력치(MU)에 따른 선량적 안정성에 대한 연구)

  • Kim Joo-Ho;Lee Sang-Gyu;Shin Hyun-Kyung;Lee Suk;Na Soo-Kyung;Cho Jung-Hee;Kim Dong-Wook
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.155-160
    • /
    • 2005
  • Purpose : Many authors have been introduced field in field technique and 3-D conformal radiotherapy that increased the tumor dose as well as decreased the dose of abutting critical organ. These technique have multiple beam direction and small beam segments even below 10 MU(monitor unit)for each field. we have confirmed the influence of low MU on dose output and beam stability. Materials and Methods : To study the dose output, the dose for each field was always 90MU, but it divided into different segment size: 1, 2, 3, 5, 10, 15 segments, 90, 45, 30, 18, 9, 6 MU the measurements were carried out for X-ray energy 4 MV, 6 MV, 10 MV of three LINAC(Varian 600C, 2100C, 2100C, 2100C/D), in addition each measurement was randomly repeated three times for each energy. To study the field symmetry and flatness, X-omat V films were irradiated. After being developed, films were scanned and analyzed using densitometer. Results : Influence of low MU on dose is slightly more increase output about $1.2{\sim}2.9%$ in cGy/mu than 90MU, but may not changed beam quality(flatness or symmetry), Output stability depends on dose rate(PRF)rather than beam energy, field size. Conclusion : Presented result are under the limits(out put<3%, flatness<${\pm}3%$, symmetry<2%). The 3 accelerators are safe to use and to perform conformal radiotherapy treatments in small segments, small MU around 10MU. but Even if the result presented here under the limits, continuous adjustments and periodic QA should be done for use of small MU

  • PDF