• Title/Summary/Keyword: 3D Volumes

Search Result 229, Processing Time 0.035 seconds

The Study for Estimating Traffic Volumes on Urban Roads Using Spatial Statistic and Navigation Data (공간통계기법과 내비게이션 자료를 활용한 도시부 도로 교통량 추정연구)

  • HONG, Dahee;KIM, Jinho;JANG, Doogik;LEE, Taewoo
    • Journal of Korean Society of Transportation
    • /
    • v.35 no.3
    • /
    • pp.220-233
    • /
    • 2017
  • Traffic volumes are fundamental data widely used in various traffic analysis, such as origin-and-destination establishment, total traveled kilometer distance calculation, congestion evaluation, and so on. The low number of links collecting the traffic-volume data in a large urban highway network has weakened the quality of the analyses in practice. This study proposes a method to estimate the traffic volume data on a highway link where no collection device is available by introducing a spatial statistic technique with (1) the traffic-volume data from TOPIS, and National Transport Information Center in the Ministry of Land, Infrastructure, and (2) the navigation data from private navigation. Two different component models were prepared for the interrupted and the uninterrupted flows respectively, due to their different traffic-flow characteristics: the piecewise constant function and the regression kriging. The comparison of the traffic volumes estimated by the proposed method against the ones counted in the field showed that the level of error includes 6.26% in MAPE and 5,410 in RMSE, and thus the prediction error is 20.3% in MAPE.

Pressure Effects on the Aquation of $cis-[Co(en)(NH_3)_2Cl_2]Cl$ in Acetone-Water Mixtures (아세톤-물 혼합용매에서 $cis-[Co(en)(NH_3)_2Cl_2]Cl$의 수화반응에 미치는 압력의 영향)

  • Jong-Jae Chung;Byung-Hwan Lee
    • Journal of the Korean Chemical Society
    • /
    • v.29 no.5
    • /
    • pp.472-477
    • /
    • 1985
  • The rates for the aquation of $cis-[Co(en)(NH_3)_2Cl_2]Cl in acetone-water mixtures have been measured at various pressures and temperatures by the electric conductivity method. The rate constant measured at 25$^{\circ}$C in pure water solvent is 3.47 ${\times}10^{-4}$/sec. Rate constants are increased with increasing temperature, and decreased with increasing pressure and mole fraction of acetone. Activation volumes and other activation parameters are calculated from these rate constants. The activation volumes are all positive and lie in the limited range +2.82~+$8.2cm^3$/mole. The rate constants in aqueous acetone solution are analyzed with the solvent compositions. Plots of log $k_{obs}$ vs. Grunwald-Winstein Y values show that log $k_{obs}$ varies linearly and the gradients are about 0.25. The applications of a free energy cycle relating the process initial state ${\to}$ transition state in water to that in acetone-water mixture show that the changes in solvation of the transition state have a dominant effect on the rate. From these results the aquation of this complex would be discussed in terms of dissociative mechanism ($I_d$).

  • PDF

Structure-From-Motion Approach to the Reconstruction of Surfaces for Earthwork Planning

  • Nassar, Khaled;Jung, Young-Han
    • Journal of Construction Engineering and Project Management
    • /
    • v.2 no.3
    • /
    • pp.1-7
    • /
    • 2012
  • The reconstruction of surfaces from unorganized point clouds can provide very useful information for construction managers. Although point clouds are generally created using 3D scanners, they can also be generated via the structure-from-motion technique using a sequence of images. Here we report a novel surface reconstruction technique for modeling and quantifying earthworks that can be used for preliminary planning, project updates and estimating of earthwork quantities, as well as embedded planning systems in construction equipment. The application of structure-from-motion techniques in earth works is examined and its advantages and limitations identified. Data from 23 earthwork excavation construction sites were collected and analyzed. 3D surface reconstructions during the construction phase were compared to the original land form. Similar experiments were conducted with piles of earth and the results analyzed to determine appropriate ranges of use for structure-from-motion surface reconstructions in earthwork applications. The technique was found to be most suited to pile of materials with volumes less than 2000 m3. Piles up to 10 m in height and with base areas up to $300m^2$ were also successfully reconstructed. These results should be of interest to contractors seeking to utilize new technology to optimize operational efficiency.

Effective Application of Digital Photogrammetry using Local Terrain Model (국부지형모형을 이용한 수치사진측량의 효율적 적용)

  • 박운용;김정희;문두열;정공운
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.10a
    • /
    • pp.199-204
    • /
    • 2003
  • Digital high resolution cameras are widely available, and are increasingly use in digital close-range photogrammetry. And photogrammetry instruments are developing rapidly and the precision is improving continuously, The building of 3D terrains of high precision are possible and the calculation of the areas or the earthwork volumes have high precision due to the development of the technique of the spatial information system using computer, In this study, using the digital camera which has capacity of keeping numerical value by itself and easy carrying, we analyze the positioning error according to various change of photographing condition. Also we t]v to find a effective method of acquiring basis data for 3D monitoring of high-accuracy in pixel degree through digital close-range photogrammetry with bundle adjustment for local terrain model generation and earthwork volume.

  • PDF

A Post Smoothing Algorithm for Vessel Segmentation

  • Li, Jiangtao;Lee, Hyo Jong
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.11a
    • /
    • pp.345-346
    • /
    • 2009
  • The segmentation of vessel including portal vein, hepatic vein and artery, from Computed Tomography (CT) images plays an important role in the therapeutic strategies for hepatic diseases. Representing segmented vessels in three dimensional spaces is extremely useful for doctors to plan liver surgery. In this paper, proposed method is focused on smoothing technique of segmented 3D liver vessels, which derived from 3D region growing approach. A pixel expand algorithm has been developed first to avoid vessel lose and disconnection cased by the next smoothing technique. And then a binary volume filtering technique has been implemented and applied to make the segmented binary vessel volume qualitatively smoother. This strategy uses an iterative relaxation process to extract isosurfaces from binary volumes while retaining anatomical structure and important features in the volume. Hard and irregular place in volume image has been eliminated as shown in the result part, which also demonstrated that proposed method is a suitable smoothing solution for post processing of fine vessel segmentation.

Small Bowel Sparing Effect of Small Bowel Displacement System in 3D-CRT and IMRT for Cervix Cancer (자궁경부암의 3D-CRT와 IMRT시 소장전위장치의 소장 선량에 대한 영향)

  • Kang, Min-Kyu;Huh, Seung-Jae;Han, Young-Yih;Park, Won;Ju, Sang-Gyu;Kim, Kyoung-Ju;Lee, Jeung-Eun;Park, Young-Je;Nam, Hee-Rim;Lim, Do-Hoon;Ahn, Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.22 no.2
    • /
    • pp.130-137
    • /
    • 2004
  • Purpose : In radiotherapy for cervix cancer, both 3-dimensioal radiotherapy (3D-CRT) and intensity-modulated radiation therapy (IMRT) could reduce the dose to the small bowel (SB), while the small bowel displacement system (SBDS) could reduce the SB volume in the pelvic cavity. To evaluate the effect of the SBDS on the dose to the SB in 3D-CRT and IMRT plans, 3D-CRT and IMRT plans, with or without SBDS, were compared. Materials and Methods : Ten consecutive uterine cervix cancer patients, receiving curative radiotherapy, were accrued. Ten pairs of computerized tomography (CT) scans were obtained in the prone position, with or without SBDS, which consisted of a Styrofoam compression device and an individualized custom-made abdominal immobilization device. Both 3D-CRT, using the 4-field box technique, and IMRT plans, with 7 portals of 15 MV X-ray, were generated for each CT image, and proscribed 50 Gy (25 fractions) to the isocenter. For the SB, the volume change due to the SBDS and the DVHs of the four different plans were analyzed using palled t-tests. Results : The SBDS significantly reduced the mean SB volume from 522 to 262 cm$^{3}$ (49.8$\%$ reduction). The SB volumes that received a dose of 10$\~$50 Gy were significantly reduced in 3D-CRT (65$\~$80$\%$ reduction) and IMRT plans (54$\~$67$\%$ reduction) using the SBDS. When the SB volumes that received 20$\~$50 Gy were compared between the 3D-CRT and IMRT plans, those of the IMRT without the SBDS were significantly less, by 6$\~$7$\%$, than those for the 3D-CRT without the SBDS, but the volume difference was less than 1$\%$ when using the SBDS. Conclusion : The SBDS reduced the radiation dose to the SB in both the 3D-CRT and IMRT plans, so could reduce the radiation injury of the SB.

An Indoor Space Management System using a Spatial DBMS (공간 DBMS를 이용한 실내 공간관리시스템)

  • Yi, Hyun-Jin;Kim, Hye-Young;Jun, Chul-Min
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.17 no.4
    • /
    • pp.31-38
    • /
    • 2009
  • Most 3D models found in the literature focus on theoretical topology for exterior 3D volumes. Although there are a few indoor models such as CityGML or IFC, implementing a full topology for the indoor spaces is either less practical due to the complexity or not even necessary in some application domains. Moreover, current spatial DBMSs do not support functionalities explicitly for 3D topological relations. In this study, an alternative method to build a 3D indoor model with less complexity ernativespatial DBMS is suggested. Focusnation the fact that semantic attributes can be storedion the floor surface, we suggestivemulti-layered 3D model for indoor spaces. We show the process to build the proposed model in the PostGIS, a spatial DBMS. And, then, as an example application, we illustrate the process to build and run a campus building information system.

  • PDF

Virtual lymph node analysis to evaluate axillary lymph node coverage provided by tangential breast irradiation

  • Park, Shin-Hyung;Kim, Jae-Chul;Lee, Jeong Eun;Park, In-Kyu
    • Radiation Oncology Journal
    • /
    • v.33 no.1
    • /
    • pp.50-56
    • /
    • 2015
  • Purpose: To investigate the coverage of axillary lymph node with tangential breast irradiation fields by using virtual lymph node (LN) analysis. Materials and Methods: Forty-eight women who were treated with whole breast irradiation after breast-conserving surgery were analyzed. The axillary and breast volumes were delineated according to the Radiation Therapy Oncology Group (RTOG) contouring atlas. To generate virtual LN contours, preoperative fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) scans with identifiable LN were fused with the CT scans, and the virtual LN contour were delineated on the CT. Results: The median level I and II axillary volume coverage percentages at the $V_{D95%}$ line were 33.5% (range, 5.3% to 90.4%) and 0.6% (range, 0.0% to 14.6%), respectively. Thirty-one LNs in 18 patients were delineated (26 in level I and 5 in level II). In the level I axilla, 84.6% of virtual LNs were encompassed by the 95% isodose line. In the level II axilla, by contrast, none of the virtual LNs were encompassed by the 95% isodose volumes. There was a substantial discrepancy between the RTOG contouring atlas-based axillary volume analysis and the virtual LN analysis, especially for the level I axillary coverage. The axillary volume coverage was associated with the body mass index (BMI) and breast volume. Conclusion: The tangential breast irradiation did not deliver adequate therapeutic doses to the axillary region, particularly those in the level II axilla. Patients with small breast volumes or lower BMI showed reduced axillary coverage from the tangential breast fields. For axillary LN irradiation, individualized anatomy-based radiation fields for patients would be necessary.

Design and Implementation of a Framework for Collaboration Systems in the Shipbuilding and Marine Industry (조선해양 설계분야에서 협업시스템을 위한 프레임워크의 설계 및 구현)

  • Yun, Moon-Kyeong;Kim, Hyun-Ju;Park, Min-Gil;Han, Myeong-Ki;Kim, Wan-Kyoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.270-273
    • /
    • 2015
  • In shipbuilding and marine industry, engineering and design software solutions have upgraded from the original 2D schematic data based CAD system to a modern 3D drawing-based system. Due to the fact that the massive amount of data usage in real time and data volumes of various engineering models including graphic data have increased, several problems such as lack of server resources and improper handling of 3D drawings have been raised. Besides, increasing the number of session connections per server can cause deterioration of server performance. Recently, increasing the yard's sophisticated design capabilities highlighted the need to develop engineering and design system which would not only overcome the network performance issues, but would provide efficient collaborative design environment. This paper presents an overview of the framework for collaborative engineering design system based on the virtual application (Citrix XenApp 6.5)and acceleration hardware technology of 3D graphics (NVIDIA GRID K2 solution).

  • PDF

Accuracy of virtual models in the assessment of maxillary defects

  • Kamburoglu, Kivanc;Kursun, Sebnem;Kilic, Cenk;Ozen, Tuncer
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • Purpose: This study aimed to assess the reliability of measurements performed on three-dimensional (3D) virtual models of maxillary defects obtained using cone-beam computed tomography (CBCT) and 3D optical scanning. Materials and Methods: Mechanical cavities simulating maxillary defects were prepared on the hard palate of nine cadavers. Images were obtained using a CBCT unit at three different fields-of-views (FOVs) and voxel sizes: 1) $60{\times}60mm$ FOV, $0.125mm^3$ ($FOV_{60}$); 2) $80{\times}80mm$ FOV, $0.160mm^3$ ($FOV_{80}$); and 3) $100{\times}100mm$ FOV, $0.250mm^3$ ($FOV_{100}$). Superimposition of the images was performed using software called VRMesh Design. Automated volume measurements were conducted, and differences between surfaces were demonstrated. Silicon impressions obtained from the defects were also scanned with a 3D optical scanner. Virtual models obtained using VRMesh Design were compared with impressions obtained by scanning silicon models. Gold standard volumes of the impression models were then compared with CBCT and 3D scanner measurements. Further, the general linear model was used, and the significance was set to p=0.05. Results: A comparison of the results obtained by the observers and methods revealed the p values to be smaller than 0.05, suggesting that the measurement variations were caused by both methods and observers along with the different cadaver specimens used. Further, the 3D scanner measurements were closer to the gold standard measurements when compared to the CBCT measurements. Conclusion: In the assessment of artificially created maxillary defects, the 3D scanner measurements were more accurate than the CBCT measurements.