• Title/Summary/Keyword: 3D Space

Search Result 3,629, Processing Time 0.042 seconds

An Atlas Generation Method with Tiny Blocks Removal for Efficient 3DoF+ Video Coding (효율적인 3DoF+ 비디오 부호화를 위한 작은 블록 제거를 통한 아틀라스 생성 기법)

  • Lim, Sung-Gyun;Kim, Hyun-Ho;Kim, Jae-Gon
    • Journal of Broadcast Engineering
    • /
    • v.25 no.5
    • /
    • pp.665-671
    • /
    • 2020
  • MPEG-I is actively working on standardization on the coding of immersive video which provides up to 6 degree of freedom (6DoF) in terms of viewpoint. 3DoF+ video, which provides motion parallax to omnidirectional view of 360 video, renders a view at any desired viewpoint using multiple view videos acquisitioned in a limited 3D space covered with upper body motion at a fixed position. The MPEG-I visual group is developing a test model called TMIV (Test Model for Immersive Video) in the process of development of the standard for 3DoF+ video coding. In the TMIV, the redundancy between a set of input view videos is removed, and several atlases are generated by packing patches including the remaining texture and depth regions into frames as compact as possible, and coded. This paper presents an atlas generation method that removes small-sized blocks in the atlas for more efficient 3DoF+ video coding. The proposed method shows a performance improvement of BD-rate bit savings of 0.7% and 1.4%, respectively, in natural and graphic sequences compared to TMIV.

Legal Issue in Case of Death or Injury of an International Crew While on Board (국제항공운송 승무원이 항공기내에서 사상(死傷)을 당한 경우 법률관계 - 국내외 판례의 분석을 중심으로 -)

  • Kim, Sun-Ah
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.35 no.2
    • /
    • pp.137-168
    • /
    • 2020
  • Air passengers may be compensated for damages based on the above agreement when the passenger suffers an accident to the extent that they are recognized as an accident under Article 17 of the Montreal Convention in 1999. If a flight or cabin crew and passengers both undergo an accident, passengers are subjected to compensation under the Montreal Convention however flight cabin crews will be compensated by the Labor Law, which is the governing law in the labor contract with the airline. The flight or cabin crew boarding the aircraft work is on a work contract, not a passenger transport contract. Therefore, if the flight or cabin crew on the aircraft is injured due to an accident, and the air carrier is liable for default due to a labor contract, the Labor Law, workers or survivors claim damages due to illegal acts against the employer. In which case, civil law will apply. In this regard, if a Chinese cabin crew working for a Chinese airline dies due to an accident in the Republic of Korea, whether the family of the deceased claims damages against the Chinese airline or not has international court jurisdiction in the Republic of Korea, which is the place of tort. We examined whether it is the law of the Republic of Korea or whether it's the Chinese law, the law applicable to the work contract, is applied. Also, Seoul District Court 1995.5.18. The sentence 94A 14144 was found that if the injured crew during the flight work was not satisfied with the insurance compensation under the Labor Standards Act and the Industrial Accident Compensation Insurance Act, he could claime to damage under the civil law against an air carrier or third parties responsible for the accident. This law case shows that you can claim a civil damage as a cause. In case of death due to an existing illness while on the way to work, the Korea Workers'Compensation and Welfare Service did not recognize the death of the deceased as an occupational accident, and the trial was canceled by the parents of the deceased for the survivor's benefit and funeral expenses. (Seoul Administrative Court 2017.8. 31. Although the sentence was judged as an occupational disaster in 2016, the 2016 8816 Decision), it was defeated in the appeals court (Seoul High Court 2018.7.19.Sentence 2017 No. 74186) and I criticized the judgment of the appeal by analyzing the deceased's disease and related the cause of it to workload. Sometimes, a flight or cabin crew is on board not for the flight duty such as transferring to another flight or returning to the home base or lay-over place after their scheduled flight, this is called "Deadheading". If the crew who is not considered the same as a passenger, but is not on duty, is injured in an accident, does the crew claim compensation for damages under the labor contract or whether the Montreal Convention is applied to the passenger. In conjunction with the discussion, there was a similar case, In re Mexico City Aircrash of October 31, 1979, 708 F.2d 400 (9th Cir. 1983), Demanes v. United Airlines, 348 F.Supp. 13 (C.D.Cal. 1972), Sulewski v. Federal Express Corp., 749 F.Supp. 506 (S.D.N.Y. 1990) and reviewed by the European Court of Justice (CJEU) at Wucher Helicopter GmbH and Euro-Aviation Versicherungs AG v. After examining several acts in several countries it's undeniably crucial to clearly understand the definition of "passenger" as stated in the Fridolin Santer case.

Crystal Structures of Dehydrated Partially $Sr^{2+}$-Exchanged Zeolite X, $Sr_{31}K_{30}Si_{100}A1_{92}O_{384}\;and\;Sr_{8.5}TI_{75}Si_{100}AI_{92}O_{384}$ (부분적으로 스트론튬이온으로 교환되고 탈수된, 제올라이트 X의 결정구조)

  • Kim Mi Jung;Kim Yang;Seff Karl
    • Korean Journal of Crystallography
    • /
    • v.8 no.1
    • /
    • pp.6-14
    • /
    • 1997
  • The crystal structures of $Sr_{31}K_{30}-X\;(Sr_{31}K_{30}Si_{100}A1_{92}O_{384};\;a=25.169(5) {\AA}$) and $Sr_{8.5}Tl_{75}-X (Sr_{8.5}Tl_{75}Si_{100}A1_{92}O_{384};\;a=25.041(5) {\AA}$) have been determined by single-crystal X-ray diffraction techniques in the cubic space group $\=F{d3}\;at\;21(1)^{\circ}C$. Each crystal was prepared by ion exchange in a flowing stream of aqueous $Sr(ClO_4)_2\;and\;(K\;or\;T1)NO_3$ whose mole ratio was 1 : 5 for five days. Vacuum dehydration was done at $360^{\circ}C$ for 2d. Their structures were refined to the final error indices $R_1=0.072\;and\;R_w=0.057$ with 293 reflections, and $R_1= 0.058\;and\;R_w=0.044$ with 351 reflections, for which $I>2{\sigma}(I)$, respectively. In dehydrated $Sr_{31}K_{30}-X,\;all\;Sr^{2+}$ ions and $K^+$ ions are located at five different crystallographic sites. Six-teen $Sr^{2+}$ ions per unit cell are at the centers of the double six-rings (site I), filling that position. The remaining 15 $Sr^{2+}$ ions and 17 $K^+$ ions fill site II in the supercage. These $Sr^{2+}$ and $K^+$ ions are recessed ca $0.45{\AA}\;and\;1.06{\AA}$ into the supercage, respectively, from the plane of three oxygens to which each is bound. ($Sr-O=2.45(1){\AA}\;and\;K-O=2.64(1){\AA}$) Eight $K^+$ ons occupy site III'($K-O=3.09(7){\AA}\;and\;3.11(10){\AA}$) and the remaining five $K^+$ ions occupy another site III'($K-O=2.88(7){\AA}\;and\;2.76(7){\AA}$). In $Sr_{8.5}Tl_{75}-X,\;Sr^{2+}\;and\;Tl^+$ ions also occupy five different crystallographic sites. About 8.5 $Sr^{2+}$ ions are at site I. Fifteen $Tl^+$ ions are at site I' in the sodalite cavities on threefold axes opposite double six-rings: each is $1.68{\AA}$ from the plane of its three oxygens ($T1-O=2.70(2){\AA}$). Together these fill the double six-rings. Another 32 $Tl^+$ ions fill site II opposite single six-rings in the supercage, each being $1.48{\AA}$ from the plane of three oxygens ($T1-O=2.70(1){\AA}$). About 18 $Tl^+$ ions occupy site III in the supercage ($T1-O=2.86(2){\AA}$), and the remaining 10 are found at site III' in the supercage ($T1-O=2.96(4){\AA}$).

  • PDF

Synthesis and Crystal Structure of Ag4Br4 Nanoclusters in the Sodalite Cavities of Fully K+-Exchanged Zeolite A (LTA)

  • Lim, Woo-Taik;Choi, Sik-Young;Kim, Bok-Jo;Kim, Chang-Min;Lee, In-Su;Kim, Seok-Han;Heo, Nam-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.7
    • /
    • pp.1090-1096
    • /
    • 2005
  • $Ag_4Br_4$ nanoclusters have been synthesized in about 75% of the sodalite cavities of fully $K^+$-exchanged zeolite A (LTA). An additional KBr molecule is retained in each large cavity as part of a near square-planar $K_4Br^{3+}$ cation. A single crystal of $Ag_{12}$-A, prepared by the dynamic ion-exchange of $Na_{12}$-A with aqueous 0.05 M $AgNO_3$ and washed with $CH_3OH$, was placed in a stream of flowing 0.05 M KBr in $CH_3OH$ for two days. The crystal structure of the product ($K_9(K_4Br)Si_{12}Al_{12}O_{48}{\cdot}0.75Ag_4Br_4$, a = 12.186(1) $\AA$) was determined at 294 K by single-crystal X-ray diffraction in the space group Pm m. It was refined with all measured reflections to the final error index $R_1$ = 0.080 for the 99 reflections for which $F_o\;{\gt}\;4_{\sigma}\;(F_o)$. The thirteen $K^+$ ions per unit cell are found at three crystallographically distinct positions: eight $K^+$ ions in the large cavity fill the six-ring site, three $K^+$ ions fill the eight-rings, and two $K^+$ ions are opposite four-rings in the large cavity. One bromide ion per unit cell lies opposite a four-ring in the large cavity, held there by two eight-ring and two six-ring $K^+$ ions ($K_4Br^{3+}$). Three $Ag^+$ and three $Br^-$ions per unit cell are found on 3-fold axes in the sodalite unit, indicating the formation of nano-sized $Ag_4Br_4$ clusters (interpenetrating tetrahedra; symmetry $T_d$; diameter ca. 7.9 $\AA$) in 75% of the sodalite units. Each cluster (Ag-Br = 2.93(3) $\AA$) is held in place by the coordination of its four $Ag^+$ ions to the zeolite framework (each $Ag^+$ cation is 2.52(3) $\AA$ from three six-ring oxygens) and by the coordination of its four $Br^-$ ions to $K^+$ ions through six-rings (Br-K = 3.00(4) $\AA$).

Detection of Forest Fire Damage from Sentinel-1 SAR Data through the Synergistic Use of Principal Component Analysis and K-means Clustering (Sentinel-1 SAR 영상을 이용한 주성분분석 및 K-means Clustering 기반 산불 탐지)

  • Lee, Jaese;Kim, Woohyeok;Im, Jungho;Kwon, Chunguen;Kim, Sungyong
    • Korean Journal of Remote Sensing
    • /
    • v.37 no.5_3
    • /
    • pp.1373-1387
    • /
    • 2021
  • Forest fire poses a significant threat to the environment and society, affecting carbon cycle and surface energy balance, and resulting in socioeconomic losses. Widely used multi-spectral satellite image-based approaches for burned area detection have a problem in that they do not work under cloudy conditions. Therefore, in this study, Sentinel-1 Synthetic Aperture Radar (SAR) data from Europe Space Agency, which can be collected in all weather conditions, were used to identify forest fire damaged area based on a series of processes including Principal Component Analysis (PCA) and K-means clustering. Four forest fire cases, which occurred in Gangneung·Donghae and Goseong·Sokcho in Gangwon-do of South Korea and two areas in North Korea on April 4, 2019, were examined. The estimated burned areas were evaluated using fire reference data provided by the National Institute of Forest Science (NIFOS) for two forest fire cases in South Korea, and differenced normalized burn ratio (dNBR) for all four cases. The average accuracy using the NIFOS reference data was 86% for the Gangneung·Donghae and Goseong·Sokcho fires. Evaluation using dNBR showed an average accuracy of 84% for all four forest fire cases. It was also confirmed that the stronger the burned intensity, the higher detection the accuracy, and vice versa. Given the advantage of SAR remote sensing, the proposed statistical processing and K-means clustering-based approach can be used to quickly identify forest fire damaged area across the Korean Peninsula, where a cloud cover rate is high and small-scale forest fires frequently occur.

The Survey of Cold Storage Temperature and Determine of Appropriate Statistics Probability Distribution Model (국내 식품냉장창고 온도분포 분석 및 적정 확률분포모델 설정)

  • Kim, Hyong-Tae;Kim, Sang-Kyu;Behk, Ok-Jin;Bahk, Gyung-Jin
    • Journal of Food Hygiene and Safety
    • /
    • v.27 no.3
    • /
    • pp.312-316
    • /
    • 2012
  • This study was to present the proper probability distribution models that based on the data for surveys of food cold storage temperatures as the input variables to the further MRA (Microbial risk assessment). The temperature was measured by directly visiting 7 food plants. The overall mean temperature for food cold storages in the survey was $2.55{\pm}3.55^{\circ}C$, with 2.5% of above $10^{\circ}C$, $-3.2^{\circ}C$ and $14.9^{\circ}C$ as a minimum and maximum. Temperature distributions by space-locations was $0.80{\pm}1.69^{\circ}C$, $0.59{\pm}1.68^{\circ}C$, and $0.65{\pm}1.46^{\circ}C$ as an upper (2.4~4 m), middle (1.5~2.4 m), and lower (0.7~1.5 m), respectively. Probability distributions were also created using @RISK program based on the measured temperature data. Statistical ranking was determined by the goodness of fit (GOF) to determine the proper probability distribution model. This result showed that the LogLogistic (-4.189, 5.9098, 3.2565) distribution models was found to be the most appropriate for relative MRA conduction.

The Crystal Structure of Bis(1,2-diaminopropane)palladium(Ⅱ) Bis(oxalato)palladate(Ⅱ) (Bis(1,2-diaminopropane)palladium(Ⅱ) Bis(oxalato)palladate(Ⅱ)의 결정구조)

  • Kim Sei Hwan;NagGung Hae;Jeon, Ho Jung
    • Journal of the Korean Chemical Society
    • /
    • v.37 no.6
    • /
    • pp.599-603
    • /
    • 1993
  • Crystal structure of bis(1,2-diaminopropane)palladium(II) bis(oxalato)palladate(II) has been determined by X-ray crystallography. Crystal data: $Pd_2C_{10}H_{10}N_{4}O_{8}$, $M_W$ = 573.09, orthorhombic, space group $P_{ccn}$ (No = 56), a = 16.178(5), b = 16.381(6), c = 6.685(2)$\{AA}$, V = 1771.6 $\{AA}^3$, $M_W$W = 573.09, $D_c$ = 2.014 g${\cdot}c\;m^{-3}$, Z = 4, T = 294K, F(000) = 1056.0 and $\mu$ = 20.466 c$m^{-1}$. The intensity data were collected with $Mo-K\alpha$ radiation (${\lambda}$ = 0.7107 $\AA)$ on an automatic four-circle diffractometer with a graphite monochromater. The structure was solved by Patterson method and refined by full matrix least-squares methods using Pivot weights. The final R and S values were R = 0.065, $R_W = 0.059, R_{all}$ = 0.065 and S = 4.315 for 605 observed reflections. Both cation and anion complexes are essentially planar and have dihedral angle of $18(l)^{\circ}$ between thier planes. In the crystal structure, they do not have the Magnus's salt type mixed stacks; instead, the complex anions form regular stacks along the c-axis with the M-M bond length of $3.343(5)\AA$ and their stacks are surrounded by the complex cations through hydrogen bonds with the nitrogen-oxygen distances of 2.94(3) and $3.31(4)\AA.$

  • PDF

$Ca^{++}$ Polls in Isolated Rabbit and Turtle Heart (적출된 토끼와 자라심장에서의 $Ca^{++}$ Pool)

  • Kim, In-Kyo;Lee, Joong-Woo;Kang, Doo-Hee
    • The Korean Journal of Physiology
    • /
    • v.9 no.1
    • /
    • pp.13-22
    • /
    • 1975
  • From the study of movements of $Ca^{++}$ in frog cardiac muscle, Niedergerke (1963) postulated that $Ca^{++}$ necessary for the cardiac contraction is stored in a specific pool. Langer et al (1967) and DeCaro (1967) also found a close relationship between the change of $Ca^{++}$ flux kinetics and the change of contractile force. According to the studies of several investigators, Ca II (Bailey and Dressel 1968) or phase I and II (Langer 1965, Langer et al 1967, 1971) in the $Ca^{++}$ washout curve was associated with cardiac contractility. This investigation was aimed to elucidate the anatomical region of the contractile active $Ca^{++}$ pool. At the same time, it was assumed in this study that $Ca^{++}$ in the sarcoplasmic reticulumn represents one of the major intracellular $Ca^{++}$ pool and cardiac contractility was also dependent on the intracellular $Ca^{++}$ concentration. Consequently, this experiment was performed at different temperatures to activate to activate inhibit the deactivating process of activated $Ca^{++}$ in the intracellular space to see if changes in the contractility decay curve existed at different temperatures. The isolated hearts of rabbits and turtles (Amyda maackii) were attached to the perfusion apparatus according to the method employed by Bailey and Dressel (1968). The isolated hearts were initally perfused with a full Ringer solution containing 2 mg/ml of inulin for 1 hr, and then $Ca^{++}$ and inulin-free Ringer solution was perfused while the isometric tension was recorded and a serial sample of perfusion fluid dripping from the cardiac apex was collected for 10 sec throughout experimental period. The above procedure was performed at $23^{\circ}C$, $30^{\circ}C$ and $38^{\circ}C$ on the rabbit heart and $10{\sim}13^{\circ}C$, $10^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$ and $35^{\circ}C$ on the turtle heart. After determination of $Ca^{++}$ and inulin concentration of the samples, the $Ca^{++}$, inulin washout curve and the contractile tensin decay curve were analysed according to the method of Riggs (1963). The results were summarized as follows; 1. In the rabbit heart, there are 2 inulin compartments, 3 $Ca^{++}$ compartments and sing1e exponential decay of contractile tension. In the turtle heart, there are $1{\sim}2$ inulin compartments, $1{\sim}2$ $Ca^{++}$ compartments and $1{\sim}2$ phases of contractile tension decay. The fact that the inulin space was divided into 3 compartments in the washout curve in these hearts indicates the presence of heterogeneity in cardiac perfusion, i.e., overfused and underperfused area. 2. Ca I a9d Ca II in these hearts were found to have $Ca^{++}$ in the ECF compartments because their half times in the washout curves were far smaller than those of the inulin washout curves in the rabbit heart and similar to those of the inulin washout curves in the turtle heart. Ca III in the rabbit heart may have originated from the intracellular $Ca^{++}$ store. But no Ca III in the turtle heart was found. This may be due to the fact that the iutracellular $Ca^{++}$ pool in the turtle heart was too small to detect using this experimental procedure since sarcoplasmic reticulumn in the turtle heart is poorly developed. 3. In the rabbit heart, there were no chages in the half time of Ca I, Ca II, inulin I and inulin II at different temperatures, but the half time of Ca III was significantly prolonged at lower temperatures, and the half time of the contractile tension decay tended to be prolonged at lower temperatures but this was not significant. In the turtle heart, there were no changes in the half time of Ca I, Ca II, inulin 1, inulin II and phase I of the contractile tension decay at different temperatures, but the half time of phase II of the contractile tension decay was significantly prolonged at lower temperatures. This finding indicates that intracellu!ar $Ca^{++}$ in these hearts was also responsible particulary for maintaining the cardiac contractility at the lower temperatures. 4. The half times of contractile tension decay were shorter than those of Ca II in the $Ca^{++}$ washout curves in both animal hearts. According to the above results it was shown that $Ca^{++}$ in ECF is primarily and $Ca^{++}$ in the intracellular space is partially associated with the cardic contractility.

  • PDF

A Development and Application of the Landscape Evaluation Model Based on the Biotope Classification (비오톱 유형분류를 기반으로 한 경관평가 모형개발 및 적용)

  • Park, Cheon-Jin;Ra, Jung-Hwa;Cho, Hyun-Ju;Kim, Jin-Hyo;Kwon, Oh-Sung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.4
    • /
    • pp.114-126
    • /
    • 2012
  • The purpose of this study is to find ways of the view evaluation of biotope classification before development by selecting an area, which is as large as about $10.0km^2$ around Non Gong Up, Auk Po Myun, Dalsung Gun, Daugu where the large project has been planned, as a subject of this study. The results of this study are as follows. Because of the classification of biotope, there are 23 kinds of types that are subdivided into 140 types. Three surveys for selecting the assessment indicators were performed. The first survey analyzed the importance of 22 selected assessment indicators based on the evaluation of an existing literature review and on the spot research. The second survey performed factor analysis and reclassified the value indicators. The third survey computed additive values of the selected assessment indicators. It used a method of standardizing the average importance of indicators by making their sum equal by 10. Theses additive values were then multiplied by each grade of indicators in order to make a final evaluation. The number of assessment indicators finally selected through the survey of asking specialist is vitality elements, visual obstructs elements etc 19. According to the result of evaluation of 1st, 1 grade spaces which especially valuable is analyzed that 7 spaces, 2 grade spaces for 4, 3 grade spaces for 5, 4 grade space for 2, 5 grade space for 5. Because of the evaluation of 2st, 1 grade spaces which especially valuable(1a, 1b) is analyzed that 15 spaces, 2 grade spaces which valuable is analyzed that 28 space. As the evaluation of site suitability model of this study couldn't have high applicability to other similar area because of having only one site as a subject, it is needed to do synthesize and standardization of various examples to have higher objectivity later.

The Infrared Medium-deep Survey. VIII. Quasar Luminosity Function at z ~ 5

  • Kim, Yongjung;Im, Myungshin;Jeon, Yiseul;Kim, Minjin;Pak, Soojong;Hyun, Minhee;Taak, Yoon Chan;Shin, Suhyun;Lim, Gu;Paek, Gregory S.H.;Paek, Insu;Jiang, Linhua;Choi, Changsu;Hong, Jueun;Ji, Tae-Geun;Jun, Hyunsung D.;Karouzos, Marios;Kim, Dohyeong;Kim, Duho;Kim, Jae-Woo;Kim, Ji Hoon;Lee, Hye-In;Lee, Seong-Kook;Park, Won-Kee;Yoon, Yongmin;Byeon, Seoyeon;Hwang, Sungyong;Kim, Joonho;Kim, Sophia;Park, Woojin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.45 no.1
    • /
    • pp.34.3-34.3
    • /
    • 2020
  • Faint z ~ 5 quasars with M1450 ~ -23 mag are known to be the potentially important contributors to the ultraviolet ionizing background in the post-reionization era. However, their number density has not been well determined, making it difficult to assess their role in the early ionization of the intergalactic medium (IGM). In this work, we present the updated results of our z ~ 5 quasar survey using the Infrared Medium-deep Survey (IMS), a near-infrared imaging survey covering an area of 85 square degrees. From our spectroscopic observations with the Gemini Multi-Object Spectrograph (GMOS) on the Gemini-South 8 m Telescope, we discovered eight new quasars at z ~ 5 with -26.1 ≤ M1450 ≤ -23.3. Combining our IMS faint quasars with the brighter Sloan Digital Sky Survey (SDSS) quasars, we derive, for the first time, the z ~ 5 quasar luminosity function (QLF) without any fixed parameters down to the magnitude limit of M1450 = -23 mag. We find that the faint-end slope of the QLF is very flat (-1.2) with a characteristic luminosity of -25.7 mag. The number density of z ~ 5 quasars from the QLF gives lower ionizing emissivity and ionizing photon density than those in previous works. These results imply that quasars are responsible for only 10-20% of the photons required to completely ionize the IGM at z ~ 5, disfavoring the idea that quasars alone could have ionized the IGM at z ~ 5.

  • PDF