• Title/Summary/Keyword: 3D Sensitivity Curve

Search Result 56, Processing Time 0.024 seconds

Change of Characteristic Curves using Light Emission Spectrum of the Intensifying Screens (증감지의 발광스펙트럼에 따른 특성곡선의 변화)

  • Yoon, Chul-Ho;Kang, Hong-Seok;Lee, In-Ja;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.13 no.2
    • /
    • pp.21-25
    • /
    • 1990
  • This report is study about difference of H-D curve in regular film and ortho type film, and obtained results as follows : 1. In the blue-color emission intensifying screen, ortho type films and in the green-color emission intensifying screens, regular type are decreased in their gradient. 2. When joint use of regular type film and ortho type film, the gradient difference not seen in blue color screen. 3. The gradient difference seen clearly in G4, KM screens(green color emission intensifying). Especially, in part of high film density, the gradient difference are great. So we have to right use of screen and film because not matched used of theare the sensitivity and gradient are decrease.

  • PDF

Interpretation of Receiver Operating Characteristics (ROC) (ROC(receiver operating characteristics) 해석)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.30 no.3
    • /
    • pp.155-158
    • /
    • 2000
  • The purpose of this paper is to explain the making procedure and the usage of receiver operating characteristic (ROC) curve for interpretation of radiographic images. The conventional radiograms obtained after the creation of the lesions in the acrylic plates and were enhanced in color. The observer were informed of which tooth to examine, the 'a priori' probability of a lesion present and the approximate diameter of the lesions. The two groups of films were interpreted separately by the same observer using the same rating scale. The following rating scale was used: A; definitely no lesion, B; probably no lesion, C; not sure, D; probably a lesion, and E; definitely a lesion. In analysis, for each observer the diagnostic results in terms of true positive (TP) and false positive (FP) decisions were plotted on a graph. The lowest point on the graph represents the TP and FP when only decisions designated as E according to the rating scale are included. The next point shows the TP and FP values when diagnoses designated as D are added and so forth. By connecting such plot points, a receiver operating characteristic (ROC) curves is obtained. The area under the curve represents the diagnostic accuracy resulting from a diagnostic performance at pure chance level and a value of 1.0 at perfect performance. This method has been known as an useful method to detect the minute difference for each radiographic technic, each observer and for the different lesion depths.

  • PDF

Diagnostic Value of Ceruloplasmin in the Diagnosis of Pediatric Wilson's Disease

  • Kim, Jung Ah;Kim, Hyun Jin;Cho, Jin Min;Oh, Seak Hee;Lee, Beom Hee;Kim, Gu-Hwan;Choi, Jin-Ho;Kim, Kyung Mo;Yoo, Han-Wook
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.18 no.3
    • /
    • pp.187-192
    • /
    • 2015
  • Purpose: Measurement of serum ceruloplasmin level is the first step in screening for Wilson's disease (WD). Despite the rarity of WD in the general population, ceruloplasmin levels are routinely measured through hepatitis screening in both adults and children. Herein, we evaluated the diagnostic value of ceruloplasmin for the diagnosis of WD among children with hepatitis. Methods: We retrospectively reviewed data on serum ceruloplasmin levels measured as a serologic marker for patients with hepatitis at Asan Medical Center (Seoul, Korea) between from January 2004 to November 2013. The diagnosis of WD was confirmed by the identification of pathogenic variants in the ATP7B gene. To determine the diagnostic accuracy of ceruloplasmin, receiver operation characteristic (ROC) curves were constructed and the area under curve (AUC) were calculated. Results: Measurements of serum ceruloplasmin were performed in 2,834 children who had hepatitis. Among these, 181 (6.4%) children were diagnosed with WD. The sensitivity, specificity, and accuracy of a ceruloplasmin level of <20 mg/dL in the discrimination of WD were 93.4%, 84.2%, and 84.8%, respectively. In this study, 418 (14.7%) false-positive cases and 12 (0.4%) false-negative cases were noted. Using a ROC curve, a ceruloplasmin level of ${\leq}16.6mg/dL$ showed the highest AUC value (0.956) with a sensitivity of 91.2%, a specificity of 94.9%, and an accuracy of 94.7%. Conclusion: The measurement of serum ceruloplasmin was frequently used for the screening of WD in children, despite a low positive rate. The diagnostic value of ceruloplasmin may be strengthened by adopting a new lower cut-off level.

Increased Wall Enhancement Extent Representing Higher Rupture Risk of Unruptured Intracranial Aneurysms

  • Jiang, Yeqing;Xu, Feng;Huang, Lei;Lu, Gang;Ge, Liang;Wan, Hailin;Geng, Daoying;Zhang, Xiaolong
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.189-197
    • /
    • 2021
  • Objective : This study aims to investigate the relationship between aneurysm wall enhancement and clinical rupture risks based on the magnetic resonance vessel wall imaging (MR-VWI) quantitative methods. Methods : One hundred and eight patients with 127 unruptured aneurysms were prospectively enrolled from Feburary 2016 to October 2017. Aneurysms were divided into high risk (≥10) and intermediate-low risk group (<10) according to the PHASES (Population, Hypertension, Age, Size of aneurysm, Earlier SAH history from another aneurysm, Site of aneurysm) scores. Clinical risk factors, aneurysm morphology, and wall enhancement index (WEI) calculated using 3D MR-VWI were analyzed and compared. Results : In comparison of high-risk and intermediated-low risk groups, univariate analysis showed that neck width (4.5±3.3 mm vs. 3.4±1.7 mm, p=0.002), the presence of wall enhancement (100.0% vs. 62.9%, p<0.001), and WEI (1.6±0.6 vs. 0.8±0.8, p<0.001) were significantly associated with high rupture risk. Multivariate regression analysis revealed that WEI was the most important factor in predicting high rupture risk (odds ratio, 2.6; 95% confidence interval, 1.4-4.9; p=0.002). The receiver operating characteristic (ROC) curve analysis can efficiently differentiate higher risk aneurysms (area under the curve, 0.780; p<0.001) which have a reliable WEI cutoff value (1.04; sensitivity, 0.833; specificity, 0.67) predictive of high rupture risk. Conclusion : Aneurysms with higher rupture risk based on PHASES score demonstrate increased neck width, wall enhancement, and the enhancement intensity. Higher WEI in unruptured aneurysms has a predictive value for increased rupture risk.

S100ß, Matrix Metalloproteinase-9, D-dimer, and Heat Shock Protein 70 Are Serologic Biomarkers of Acute Cerebral Infarction in a Mouse Model of Transient MCA Occlusion

  • Choi, Jong-Il;Ha, Sung-Kon;Lim, Dong-Jun;Kim, Sang-Dae;Kim, Se-Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.5
    • /
    • pp.548-558
    • /
    • 2018
  • Objective : Diagnosing acute cerebral infarction is crucial in determining prognosis of stroke patients. Although many serologic tests for prompt diagnosis are available, the clinical application of serologic tests is currently limited. We investigated whether $S100{\beta}$, matrix metalloproteinase-9 (MMP-9), D-dimer, and heat shock protein 70 (HSP70) can be used as biomarkers for acute cerebral infarction. Methods : Focal cerebral ischemia was induced using the modified intraluminal filament technique. Mice were randomly assigned to 30-minute occlusion (n=10), 60-minute occlusion (n=10), or sham (n=5) groups. Four hours later, neurological deficits were evaluated and blood samples were obtained. Infarction volumes were calculated and plasma $S100{\beta}$, MMP-9, D-dimer, and HSP70 levels were measured using enzyme-linked immunosorbent assay. Results : The average infarction volume was $12.32{\pm}2.31mm^3$ and $46.9{\pm}7.43mm^3$ in the 30- and 60-minute groups, respectively. The mean neurological score in the two ischemic groups was $1.6{\pm}0.55$ and $3.2{\pm}0.70$, respectively. $S100{\beta}$, MMP-9, and HSP70 expressions significantly increased after 4 hours of ischemia (p=0.001). Furthermore, $S100{\beta}$ and MMP-9 expressions correlated with infarction volumes (p<0.001) and neurological deficits (p<0.001). There was no significant difference in D-dimer expression between groups (p=0.843). The area under the receiver operating characteristic curve (AUC) showed high sensitivity and specificity for MMP-9, HSP70 (AUC=1), and $S100{\beta}$ (AUC=0.98). Conclusion : $S100{\beta}$, MMP-9, and HSP70 can complement current diagnostic tools to assess cerebral infarction, suggesting their use as potential biomarkers for acute cerebral infarction.

The relation between serum levels of epidermal growth factor and necrotizing enterocolitis in preterm neonates

  • Ahmed, Heba Mostafa;Kamel, Nsreen Mostafa
    • Clinical and Experimental Pediatrics
    • /
    • v.62 no.8
    • /
    • pp.307-311
    • /
    • 2019
  • Purpose: Necrotizing enterocolitis (NEC) is one of the most serious complications of prematurity. Many risk factors can contribute to the development of NEC. The epidermal growth factor (EGF) plays a major role in intestinal barrier function, increases intestinal enzyme activity, and improves nutrient transport. The aim of this study was to assess the role of epidermal growth factor in the development of NEC in preterm neonates. Methods: In this study, 130 preterm neonates were included and divided into 3 groups, as follows: group 1, 40 preterm neonates with NEC; group 2, 50 preterm neonates with sepsis; and group 3, 40 healthy preterm neonates as controls. The NEC group was then subdivided into medical and surgical NEC subgroups. The serum EGF level was measured using enzyme-linked immunosorbent assay. Results: Serum EGF levels (pg/dL) were significantly lower in the NEC group (median [interquartile range, IQR], 9.6 [2-14]) than in the sepsis (10.1 [8-14]) and control groups (11.2 [8-14], P<0.001), with no significant difference between the sepsis and control groups, and were positively correlated with gestational age (r=0.7, P<0.001). A binary logistic regression test revealed that low EGF levels and gestational ages could significantly predict the development of NEC. The receiver-operating characteristic curve for EGF showed an optimal cutoff value of 8 pg/mL, with 73.3% sensitivity, 98% specificity, and an area under the curve of 0.92. Conclusion: The patients with NEC in this study had significantly lower serum EGF levels (P<0.001), which indicated that EGF could be a reliable marker of NEC in preterm neonates.

Probabilistic Three-Dimensional Slope Stability Analysis on Logarithmic Spiral Failure (대수누선파양에 대한 확률론적 3차원 사면안정해석)

  • 서인석;김영수
    • Geotechnical Engineering
    • /
    • v.10 no.2
    • /
    • pp.121-140
    • /
    • 1994
  • This paper presents the probabilistic model to evaluate the three-dimensional stability of layered deposits and c-0 soil slopes. Rotational slides are assumed with a cylindroid control part terminated with plane ends. And the potential failure surfaces in this study are assumed with the logarithmic spiral curve refracted at boundary of layers. This model takes into consideration the spatial variabilities of soil properties and the uncertainties stemming from insufficient number of samples and the discrepancies between laboratory measured and in -situ values of shear strength parameters. From the probabilistic approxi mate method (FOSM and SOSM method), the mean and variance of safety factor are calculated, respectively. And the programs based on above models is developed and a case study is analysed in detail to study the sensitivity of results to variations in different parameters by using the programs developed in this study. On the basis of thin study the following conclusions could be stated : (1) The sensitivity analysis shown that the probability of failure is more sensitive to the uncertainty of the angle of internal friction than that of the cohesion, (2) The total 3-D proability of failure and the critical width of failure are significantly affected by total width of slope. It is found that the total 3-D probability of failure and the critical width of failure increase with increasing the slope width when seismic forces do not exist and the total 3-D probability of failure increases with increasing the slope width and the critical width of failure decreases when seismic intensity is relatively large, (3) A decrease in the safety factor (due to effect such as a rise in the mean ground water level, lower shear strength parameters, lower values for the correction factors, etc.) would result in reduction in the critical width of failure.

  • PDF

Median Filtering Detection of Digital Images Using Pixel Gradients

  • RHEE, Kang Hyeon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.4
    • /
    • pp.195-201
    • /
    • 2015
  • For median filtering (MF) detection in altered digital images, this paper presents a new feature vector that is formed from autoregressive (AR) coefficients via an AR model of the gradients between the neighboring row and column lines in an image. Subsequently, the defined 10-D feature vector is trained in a support vector machine (SVM) for MF detection among forged images. The MF classification is compared to the median filter residual (MFR) scheme that had the same 10-D feature vector. In the experiment, three kinds of test items are area under receiver operating characteristic (ROC) curve (AUC), classification ratio, and minimal average decision error. The performance is excellent for unaltered (ORI) or once-altered images, such as $3{\times}3$ average filtering (AVE3), QF=90 JPEG (JPG90), 90% down, and 110% up to scale (DN0.9 and Up1.1) images, versus $3{\times}3$ and $5{\times}5$ median filtering (MF3 and MF5, respectively) and MF3 and MF5 composite images (MF35). When the forged image was post-altered with AVE3, DN0.9, UP1.1 and JPG70 after MF3, MF5 and MF35, the performance of the proposed scheme is lower than the MFR scheme. In particular, the feature vector in this paper has a superior classification ratio compared to AVE3. However, in the measured performances with unaltered, once-altered and post-altered images versus MF3, MF5 and MF35, the resultant AUC by 'sensitivity' (TP: true positive rate) and '1-specificity' (FN: false negative rate) is achieved closer to 1. Thus, it is confirmed that the grade evaluation of the proposed scheme can be rated as 'Excellent (A)'.

A Survival Prediction Model of Rats in Uncontrolled Acute Hemorrhagic Shock Using the Random Forest Classifier (랜덤 포리스트를 이용한 비제어 급성 출혈성 쇼크의 흰쥐에서의 생존 예측)

  • Choi, J.Y.;Kim, S.K.;Koo, J.M.;Kim, D.W.
    • Journal of Biomedical Engineering Research
    • /
    • v.33 no.3
    • /
    • pp.148-154
    • /
    • 2012
  • Hemorrhagic shock is a primary cause of deaths resulting from injury in the world. Although many studies have tried to diagnose accurately hemorrhagic shock in the early stage, such attempts were not successful due to compensatory mechanisms of humans. The objective of this study was to construct a survival prediction model of rats in acute hemorrhagic shock using a random forest (RF) model. Heart rate (HR), mean arterial pressure (MAP), respiration rate (RR), lactate concentration (LC), and peripheral perfusion (PP) measured in rats were used as input variables for the RF model and its performance was compared with that of a logistic regression (LR) model. Before constructing the models, we performed 5-fold cross validation for RF variable selection, and forward stepwise variable selection for the LR model to examine which variables were important for the models. For the LR model, sensitivity, specificity, accuracy, and area under the receiver operating characteristic curve (ROC-AUC) were 0.83, 0.95, 0.88, and 0.96, respectively. For the RF models, sensitivity, specificity, accuracy, and AUC were 0.97, 0.95, 0.96, and 0.99, respectively. In conclusion, the RF model was superior to the LR model for survival prediction in the rat model.

A Study on the Circadian Rhythm of Opiate Receptor in Rat Brain (백서 뇌내 Opiate 수용체의 일주기 변동에 대한 연구)

  • Lee, Moo-Suck;Kim, Ki-Won;Cho, Kyu-Park
    • The Korean Journal of Pharmacology
    • /
    • v.20 no.2
    • /
    • pp.23-34
    • /
    • 1984
  • To investigate diurnal variations of opiate receptor binding and its modification by experimental condition or treatment of various centrally-acting drugs, the amount of maximum $^3H-morphine$ binding in rat midbrain homogenates was measured at 4 hour intervals for 24 hours. Animals were conditioned under the controlled L : D, 12 : 12 cycle or D: D, 12 : 12 cycle, for 3 weeks and treated with 0.5 ml of physiological saline or drugs for 2 weeks. A highly significant diurnal rhythm with peak at 22 hour of early dark phase with an amplitude$(0.68{\pm}0.06\;pmole/mg\;protein)$ of +51.1% and nadir $(0.33{\pm}0.03\;mole/mg\;prtein)$ at 18 hour of late light phase with an amplitude of -26.6% was found in control group. 24 tour mean of $^3H-morphine$ binding was $0.45{\pm}0.03\;pmole/mg$ protein respectively. Constant dark adaptation or treatment of reserpine, pargyline, imipramine, amphetamine and chlorpromazine modified the diurnal rhythm in the time of peak and nadir binding shape, phase, amplitude of the diurnal curve and 24 hour mean of $^3H-morphine$ binding. However, Kd values were not changed in all experimental groups : Statistical analysis at times of least and great binding indicates that the differences in $^3H-morphine$ binding were due to changes not in the affinity, but in the number of binding sites. The results are interpreted with regard to the diurnal rhythm of opiate receptor finding. The modes of action of psychoactive drugs are closely related to postulated changes of receptor sensitivity in neuropharmacological aspects.

  • PDF